Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹22.5 L+₹2.3 L (11.3%)Rejected-Finance MOHALLA KAMA KHAN WARD NO 07 HOUSE NO 88 DISTT POONCH J K | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
9 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 881 EWS
GE 881 EWS C/o 56 APO
CLEANING AND REPAIR OF SEWAGE LINES, SEPTIC TANKS, SOAKAGE WELLS AND ALLIED WORKS AND REPAIR/ REPLACEMENT OF EXTERNAL SECURITY LIGHTS/ FIXTURES AND CONNECTED WORKS UNDER AOR OF STN HQ KG UNDER GE 881 EWS
2021_MES_477266_2
GE/PNH-40/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹38,000
Yes
3 Jan 2022
27 Oct 2021
10 Nov 2021
27 Oct 2021
9 Nov 2021
28 Oct 2021
60 days
Amount
B&R PORTION:- Cleaning/clearing and maintenance of sewage lines any bore, manholes including CI stacks gully traps under ground lines any depth by removing any type of blockage from drain 100/150mm dia by roding from manholes to manholes and flushing after cleaning including manholes sludge/sludge water to be disposed off outside the periphery of defence land including taking off manhole covers and refixing the same after cleaning sewage lines, sewage lines cleared/cleaned under this item are to be maintained and kept fully functional by removing any type of blockage. The cost of this operation/provision shall be deemed to be included in unit rate quoted by the contractor complete all as specified and directed. Note :- Unit rate quoted by tenderer shall include taking out sludge from line and manholes(liquid/semi liquid/solid) excavtion of borrow pits for dumping sludge, removing including loading/unloading and transportation etc
Opening of cover(of any description and size) of septic tanks and soakage wells/pits, desludging/dewatering of septic tanks and soakage wells/pits of any size and depth by mechanical pumping (truct mounted(Mechanically)/Manually making it functional to the entire satisfaction of Engr-in -Charge and removing sludge outside the periphery of defence land at bis own arrangement where sanitary hazards do not take place as per directions/instructions of civil authority and burried in excavated pits and covering the same including refixing covers after cleaning complete all as specified and directed. Note:- Unit rate quoted by tenderer shall include taking out sludge from line and manholes(liquid/semi liquid/solid) excavtion of borrow pits for dumping sludge, removing including loading/unloading and transportation etc
Cleaning of blocked WC seats upto first manhole and making the drain pipe of any dia fully functional by flusing with water including disposal of sludge etc away from residential area and burring in borrow pits (excavation and earth work shall be deemed to be included in the unit rate) complete all as specified and directed.
Demolition of cement concrete (un reinforced) in ground floors and paving n exc. 15 cm. thickness, below or above ground level complete all as specified and directed. .
Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches pillars etc, complete all as specified and directed.
Demolition of reinforced cement concrete and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of cement concrete (un-reinforeced) of any description and in any position (drain bed and channels) not otherwise specifically provided for complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
Excavation in trenches n.exc 1.5m deep and 1.5m wide and not exc 10 sqm on plan and getting out soft/loose soil complete all as specified and directed.
Excavation in trenches n.exc 1.5m deep and 1.5m wide and not exc 10 sqm on plan and getting out hard/dense soil complete all as specified and directed.
M&L for PCC 1: 4:8 type D2 (using 40mm graded stone agg) as in foundation filling and mass concrete complete all as specified and directed.
M & L for 25mm thick PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in sub base and flooring, etc. complete all as specified and directed.
M&L for chequered cement concrete tiles with mixture of white and grey cement in equal proportion and no pigments of size 30cmx30cmx25 mm thick,set, jointed and pointed in neat cement surry in floors including 20 mm thick screed bed in CM 1:6 for laying floor tiles complete all as specified and diected.
M&L for PCC 1:4:8 (using 40 mmgraded stone agg) type D2 as in foundation and sub base etc complete all as specified and directed.
M&L machine pressed precast concrete inter locking paver block with grey cement and pigment(Reflective type) in any shape and size confirming to IS-15658-2006 of 80 mm thickness M-40 grade complete all as specified and directed.
M&L for stone dust layed in floors or paving etc spread, levelled and rammed including watering complete all as specified and directed.
Returning filling including spreading levelling watering and well ramming in layers n.exc 25cm in soil complete all as specified and directed.
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M & L for Brick work with sub class 'B' bricks straight or curved on plan exc 6m in mean radius, built in cement mortar 1:4 complete all as specified and directed.
M & L for Walling of random rubble, Brought upto course, built in CM 1:6 complete all as specified and directed.
All as per item No. 20 above but except stone complete all as specified and directed.
Extra over stone walling for hammer dressing to face stones and dressing or face beds and joints with max depression 20 mm as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed.
M & L for Plain cement concrete 1:2:4 type B-1, (using 20 mm graded stone aggregate) as in bed blocks, coping, benching and similar work including necessary form work complete all as specified and directed.
M&L for Rendering 15 mm thick in cement mortar 1: 4 on fair faces of brick work or concrete surfaces, chajja and suspended work finished even and smooth without using extra cement, complete all as specified and directed.
M&L for Rendering 15 mm thick in cement mortar 1: 6 on other than fair faces of brick work or concrete surfaces, finished even and smooth with out using extra cement, complete all as specified and directed.
M&L for PCC 1:3:6 Type C-1 using 20 mm graded stone aggregate in surface channels and drains/benching complete all as specified and directed.
Demolition and breaking up 150mm dia in bore drain pipes (salt glazed ware, AC or Reinforced concrete) set in cement mortar, complete all as specified and directed.
M&L for 150mm dia in bore SGSW drain pipes laid in trenches and jointed complete all as specified and directed.
M&L for concrete bed to drain pipes including packing under and haunching against the sides of pipe they are laid with PCC 1:4:8 type D-2 for pipe of 150mm dia in bore, complete all as specified and directed.
Taking up/down AC soil ,waste and vent pipe 100/110mm bore size set in CM from walls/trenches complete all as specified and directed.
All as per Item No 30 above but 75mm bore complete all as specified and directed.
S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid/fixed in trenches/walls or in floors of bore 110mm complete all as specified and directed.
S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid/fixed in trenches/walls or in floors of bore 75mm complete all as specified and directed.
S&F in repair PVC(SWR) 110mm pipes single socketed in any length with rubber rings joints laid and fixed to walls including clamps of the following bore complete all as specified and directed.
S&F in repair PVC(SWR) 75mm pipes single socketed in any length with rubber rings joints laid and fixed to walls including clamps of the following bore complete all as specified and directed.
S&F PVC (SWR) 110 mm bore bends (any radius) fixed with cement joint complete all as specified and directed.
S&F PVC (SWR) 110 mm bore branch piece (Tee) fixed to walls with cement joint with or w/o oval access door complete all as specified and directed.
S&F PVC (SWR) 75 mm bore bends (any radius) fixed with cement joint complete all as specified and directed.
S&F PVC (SWR) 75 mm bore branch piece (Tee) fixed to walls with cement joint with or w/o ovel access door complete all as specified and directed.
Cutting into existing manholes for removing existing branch drain, making good to pipe and rendering cutting out branch channel, and making good benchings complete all as specified and directed.
M&L for Pre- cast reinforced cement concrete M-15 (1:2:4 nominal mix ) type B-I, (Using 20mm grade stone agg) set in cement mortar 1:4 as in manhole cover complete all as specified and directed.
S & F 6 to 8mm dia mild steel bars cut to length bent to shape required, including cranking hooking ends & binding with and including mild steel wire ( annealed) not less than 0.90mm dia complete all as specified and directed.
M&L for 10mm dia and over TMT bars cut to length, bend to shape reqd, including cranking, bending and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S & F Vitreous china Orissa pan of pattern, long pan size 580x440mm , with ‘P’ or ‘S’ trap, front or back inlet and integral foot rest complete fixed in repairs including lime concrete bedding and connection to drain or outgoing pipe and to flushing pipe, and anti siphon pipe. complete all as specified and directed.
S&F in repairs PVC low level flushing cistern of 10 Litres with all internal fittings incl flush pipe and fixing to supply pipe complete all as specified and directed.
S & F in repair PVC connection 45 cm long fitted with PTMT nut and washer on both ends, fixed to 15 mm bore iron pipes complete all as specified and directed.
S&F in repair vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) all as specified and directed.
S&F in repair Gratings, 125 mm dia with waste hole of PTMT complete all as specified and directed.
Dismantling of cast iron or reinforced concrete drain pipes 100mm/75mm dia, jointed in cement mortar and taking out of trenches, if required complete including all fittings complete all as specified and directed.
S&F 100 mm bore CI (sand cast) soil, waste and vent pipe, in any length, without ears, with cement joint, laid in floors or in trenches etc. complete all as specified and directed.
S&F 75 mm bore CI (sand cast) soil, waste and vent pipe, in any length, without ears, with cement joint, laid in floors or in trenches/wall etc complete all as specified and directed.
S & F in repair CI Cowl suitable for bore of pipe 75mm complete all as specified and directed
Filling of soakage pits as specified with fresh broken bricks of guage 40 to 80 mm size complete all as specified and directed.
E&M PORTION Taking down old unsv street light fittings any type from pile/ wall/ other similar situation and refixing, re-connecting the same in existing position after carrying out necessary repair/ replacement of unsv accessories to make the fittings functional, complete all as speecified and directed. Note:-Accessories required to make the fittings functional shall be measured & paid seperately as supply only under relevent items.
Supply only the following accessories to be incorporated for repair of street light fittings taken out under item No-54 above are as under:-
LED driver for street light fittings of 25/30 watt capacity complete all as specified and directed.
LED driver for street light fittings of 40/45 watt capacity complete all as specified and directed.
LED driver for street light fittings of 60/70 watt capacity complete all as specified and directed.
LED driver for street light fittings of 90/120 watt capacity complete all as specified and directed.
Glass cover for street light fittings upto 120 watt capacity complete all as specified and directed.
S&F Thermo plastic street light weather proof out door type junction box of size 200mmx 160mm x 98mm complete with 4 way connector-01 No, 6 Amps SP MCB-01 No easy openable and having locking arrangement including incoming and out going cable holes with fixing MS clamp and water tight polymide cable gland for each connection with & including taking down old unsv junction box, complete all as specified and directed. Make:-Sintex / HENSEL / National.
Supply and laying in trenches or passing through pipe 1100 volts grade armoured, heavy duty XLPE electric cable with aluminium conductor of sizes 25 Sqmm 3.5 core including taking down old/ unsv cable any type complete all as specified and directed.
All as per Item No 57 above but 16 Sqmm 2 core complete all as specified and directed.
All as per Item No 57 above but 10 Sqmm 2 core complete all as specified and directed.
Supply and laying sand river for cushioning with layers of sand 8 cm before laying of cable and 15 cm after laying of cable (total 23 cm) in trenches, duly punning to a thickness of 18 cm complete all as specified & directed. ( Note: Thickness after punning shall be measured for payment )
Supply and laying burnt best quality locally available bricks laid in trenches perpendicular to UG cable for cable protection complete all as specified and as directed.
S&F in repair 40mm bore galvanised steel water tubing, light grade including all fittings laid in trenches/ fixed to pole/ along wall/ floor etc for protection of cable/ strip including fixing to pole with M.S. clamp, nuts, bolts etc complete all as specified and as directed.
Supply & fix PVC insulated, 1100 volts grad, stranded aluminium conductor cable 2.5 Sqmm, twin core, connecting from Street light junction box to light fittings including taking down old/ unsv cable any type complete all as specified and directed.
S&F in repair PVC conduit/pipes 15 mm dia and fixed with the pole by clamping / saddling for protection of connecting wires, connection from junction box to light fittings, including taking down old pipe any type complete all as specified and as directed.
S&F Energy efficient LED street light fittings, 60 Watt,230 volt AC out door type with high pressure die-cast aluminium housing and heat resistent complete with dirver, lamp bracket with impact and corrosion resistant including thermal management in multiple optic complete with IP66 protection, with inbuilt surge protection device including taking down old us light fittings any type complete all as specified and as directed. Make: Havells Cat Part No. ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent Cat part of Make as specified in PS.
S&F in repair Energy efficient LED light fittings, 70 Watt, die-cast aluminium body flood light, with power LED and dirver complete all as specified and as directed.
S&F street light bracket made out of GI tubing 40mm bore, medium grade, 1.5 metre long bent to shape as directed, including suitable MS clamp of MS Flat with MS bolts, nuts and washer fixed to steel tubular pole/PCC pole duly painted with two coats of aluminium paint including taking down u/s bracket any type all as specified and as directed.
Supply and fixing 1100 Volts grade heavy duty cable PVC insulated aluminum conductor, served with inner sheathing of PVC tape and overall PVC sheathed twin core cable flat or circular of size of aluminum conductor 6 sq mm stranded conductor including taking down old UNSV cable complete all as specified and directed. Make : Havells/Polycab/Finolex.
S&F conecting and commissioning of street light fittings 30 watt LED, IP-66 prootection, single piece pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device upto 5KV prewired including 1.6 mtr long 40mm bore light grade GI pipe mounting bracket made to shape with and including MS clamp of F1 40mmx6mm with bolts, nuts and washers and conductor to fitting with 3 core 1.5 sqmm PVC insulated cable complete all as specified and directed. Make: Havells cat part No ENDURAPEARLSL30WLED757SASYTOPCMP or equivalent in Philips/ Bajaj/ CG/ C&S Electric
S&F Building security light fittings, made of pressure die cast aluminium housing with power LED 30 watt having IP protection IP-66 including suitable bracket and fising material complete all as specified and directed.
Supply and fixing1100 Volts grade heavy duty cable PVC insulated aluminum conductor, served with inner sheathing of PVC tape and overall PVC sheathed twin core cable flat or circular of size of aluminum conductor 10 sq mm stranded conductor including taking down old UNSV cable complete all as specified and directed. Make : Havells/Polycab/Finolex.
Supply and Replacement in repair of Earthing for poles and other machinery/eqpt using GI strip as earth lead and MS galvanized steel earth plate electrode 600x600x 6.3mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron strips 32x6mm with GI pipe, nuts, bolts and washers complete upto and PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame, charcoal, common salt15cm at round the earth plate watering pipe 20mm med grade/galvanized and 40mm dia GI pipe light grade for GI strip protected steel with funnel complete all as specified and directed as shown in electrical plate No 3 of SSR Part-I 2009.
S&F in repair of aluminium strip 25 x 3.15mm with saddles and fixing screws, insulators rawal plugs etc for conductor for roof and fixed on wall upto test point complete all as specified and directed.
S&F in repair of copper strip 20 x 3.15mm with saddles and fixing screws, insulators rawal plugs etc for conductor for roof and fixed on wall upto test point complete all as specified and directed.
S&F in repair of galvanized iron strip 32 x 6mm fixed with saddles & fixing screws, PVC dash fastners, insulators fixed from test point to earth on walls or burried in ground / drawn into hume pipe complete all as specified and directed.
S&F in repair of single pointed air termination Aluminium rod 12mm dia, 300 mm long complete all as specified and directed.
S&F in repair of Test point terminal block made of gun metal or phosphorous bronge 75 x 75 x 25mm of 6mm thickness drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to wall for protection of test point complete all as specified and directed.
S&F Energy efficient LED street light fittings, 90 Watt, die-cast aluminium body with power LED and dirver, IP66 protection, with inbuilt surge protection device including taking down old us light fittings any type complete all as specified and directed. Make: HAVELLS Cat Part No: ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO or equivalent Cat part of Make as specified in PS.
JAMWAL CONSTRUCTION CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .