Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹22.6 L+₹1.4 L (6.85%)Rejected-Finance 10 2 NARAYAN BAG INDORE M P | L2 | Rejected-Finance Rates are high | |
| 3 | L3₹23.2 L+₹2.0 L (9.47%)Rejected-Finance | L3 | Rejected-Finance Rates are high | |
| 4 | L4₹27.6 L+₹6.5 L (30.5%)Rejected-Finance | L4 | Rejected-Finance Rates are high | |
| 5 | L5₹28.9 L+₹7.7 L (36.6%)Rejected-Finance | L5 | Rejected-Finance Rates are high |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
10 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (MIS) MHOW
GE (Maint) Inf school 75 mall road Mhow
REPAIR REPLACEMENT IMPROVEMENT OF LT ELECTRIC DISTRIBUTION SYSTEM OF INF SCHOOL AREA AT MHOW UNDER GE MIS MHOW
2021_MES_450953_1
GE MIS MHOW/21 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (MIS) MHOW
Please refer tender doucments
8 documents required · 8 mandatory
₹500
GE (MIS) MHOW
₹50,000
Yes
18 Sept 2021
12 Jun 2021
12 Jul 2021
19 Jun 2021
10 Jul 2021
26 Jun 2021
60 days
Amount
M&L for dismantaling of old cracked /unserviceable PCC poles /MS pole struts any type and size. Complete all as specified and directed.
Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil Complete all as specified and directed.
All as per item No 2 above but for each additional 1.5 m or part thereof in depth beyond the first 1.5 mtr Complete all as specified and directed.
M&L for plain Cement concrete (1:2:4) type B 2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed.
M&L for plain Cement concrete (1:4:8) type D 2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed.
M&L for palin Cement concrete (1:3:6) type C 1 (using 20 mm graded stone aggregate) as in roof kerbs or pole coupling of size (300x300) mm or chamfered on edges Complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each Complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point Complete all as specified and directed.
Sand cushioning with fine dry unwashed sand in trenches for protection of cables Complete all as specified and directed.
Supplying and laying reinforced precast concrete cable cover,Class LV, Type I, flat, size (250mm x 150mm x 40mm) Complete all as specified and directed.
Old size sub class ‘B’ bricks, laid in trenches as cable covers Complete all as specified and directed.
Supply and fixing of Steel tubes, galvanised, light grade, ISI marked 40mm bore for protection of cable under floor, road and on wall Complete all as specified and directed.
Supply and fixing of Steel tubes, galvanised, light grade, ISI marked 80 mm bore for protection of cable under floor, road and on wall Complete all as specified and directed.
S&F of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 ,9.0 metres long Complete all as specified and directed.
Supply and fixing in replacement of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection Complete all as specified and directed.
Supply and fixing in replacement of LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection Complete all as specified and directed.
Painting of transformer of capacity up to 300 KVA, 11/.433 KV with two coats synthetic enamelled spray painting after preparation of transformer surface complete all as specified and directed.
All as item 17 above but capacity 315 to 750 KVA 11/0.433 V Complete all as specified and directed.
Tracing out fault up to 11KV underground cable any size with the help of fault tracing machine and rectifying the same with joints as specified and directed to restore the supply Complete all as specified and directed. Note: (i). Joint kit shall be measured and paid separately. (ii) Earth work shall be measured and paid separately. However, width of trenches shall be allowed for payment as per authorized width given in SSR for each size of cable. (iii) All other necessary arrangements suitable for locating the faults deemed to be included in the unit rate quoted. (iv) T&P required for the entire job shall be provided by the contractor at his own end and nothing extra shall be admissible on this account. (v) Cable required, if any shall be measured and paid for separately.
Trimming/pruning of tree branches touching to the LT over head line or near to the LT over head line as per direction of AGE E/M /JE in charge complete including removing the tree branches from site complete all as specified and directed . NOTE - (a) written shut down shall be obtained from concerned JE / AGE E/M before taking the trimming work in hand by contractor (b) span from one pole to next pole (30 to 50 m) will be considered as a job. (c) T & P such as lader , rope, cutter , axes and other related material will be provided by the contractor
Supplying and fixing of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm Complete all as specified and directed.
S & F in replacement of XLPE insulated and PVC armoured heavy duty electric cables with aluminum conductor, 1100 volt grade of size 3.5 core 25 sqmm in trenches/through pipes/ducts or on poles/walls jointing to O/H conductor, LT panels, main switch with suitable size aluminum lugs and testing complete all as specified & directed for the following sizes:- Note : (a) Excavation shall be measured and paid seperately under respective items of Sch 'A' (b) All redq lugs of suitable sizes according to laying of cable is deemed to be included in the rate coated.
All as per item no. 22 above but 35 sqmm 3.5 core.
All as per item no. 22 above but 50 sqmm 3.5 core.
All as per item no. 22 above but 70 sqmm 3.5 core.
All as per item no. 22 above but 95 sqmm 3.5 core.
All as per item no. 22 above but 120 sqmm 3.5 core.
All as per item no. 22 above but 185 sqmm 3.5 core.
All as per item no. 22 above but 300 sqmm 3.5 core.
M & L for replacement MCCB 3 pole, 415 volts, fixed type 25-100 amps with breaking capacity 16 KA Complete all as specified and directed.
All as item no 30 above but 125 amps.
M & L for replacement MCCB 3 pole, 415 volts, adjustable type 160 amps with breaking capacity 36 KA Complete all as specified and directed.
All as per item no 32 above but 200 amps.
All as per item no 32 above but 250 amps.
All as per item no 32 above but 350 amps.
All as per item no 32 above but 400 amps.
M & L for replacement MCCB 4 pole, 415 volts, adjustable type 250 amps with breaking capacity 36 KA Complete all as specified and directed.
All as per item no 37 above but 350 amps.
All as per item no 32 above but 400 amps.
M & L for replacement pin type porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade Complete all as specified and directed.
All as per item no 40 above but 150mm height, 150mm dia for 11000 volts grade.
M & L for replacement shackle type porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, of height 75 mm and max dia 90 mm suitable for working pressure 1100 volts grade Complete all as specified and directed.
All as per item no. 42 above but 150mm height, 150mm dia for 11000 volts grade.
M & L for replacement disc insulator, porcelain, vitreous 145 mm high and 255,, dia ball and socket type, white, brown or green suitable for single disc asst for tension with tension clamps for conductors, working pressure 11000 volts grade Complete all as specified and directed. .Make : Jaipuria, Souhern insulators.
M & L for disconnecting from over head conductor, cutting worn out portion of LT u/g service cables of any type and size, repair including take out of cable from under ground loop and rejoint the same to restore elect sup Complete all as specified and directed.
All as per item no 44 above but from switch gears/main switch board of any type and size including suitable size of aluminium cable lugs as directed.
M&L for replacement of broken over head conductor of any type and length as required at site including removing of foreign objects if any from the over head line Complete all as specified and directed. (ACSR conductor used for replacement will be measured and paid under respective item)
Supply only aluminium conductor steel re inforced, any sizes as directed for using as jumper Complete all as specified and directed.
Restringing of loose over head conductor/GI earth wire of any size and type after untyeing binding wire from insulators/cross arms to achieve permissible sag limit of over head line including new binding wire of proper size and pruning of tree branches of concerned spans and jointing of jumpers properly complete all as specified and directed at site. Note:- (i) One job consist one span of 3-phase, 4-wire over head line. (ii) The distance of one span is approx 30 to 50 meter.
M &L for repalcement straight through joint ( Epoxy joint) for following size PVC insulated and sheathed aluminium cable Complete all as specified and directed for following sizes :-
2 core 16 sqmm to 25 sqmm or 4 core 10 to 16 Sqmm
3.5 core 25 to 35 sqmm
3.5 core 50 sq mm
3.5 core but 70 sqmm
3.5 core but 95 sqmm
3.5 core but 120 sqmm to 150 sqmm
3.5 core but 185 sqmm
All as per item No 50 above but for 11 KV (E) straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cabe of size 50 to 95 sq mm Complete all as specified and directed.
All as per item no 51 as above but outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE aromoured aluminium conductor cable of size 50 sq mm to 95 sq mm Complete all as specified and directed.
All as per item no 52 but for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE aromoured aluminium conductor cable of size 50 sq mm to 95 sq mm Complete all as specified and directed.
Material and labour in welding and painting (both weldind and painting whenever required) of old exiting lt panel of any size. NOTE- repairs to LT panel boards complete with necessary welding works to door , replacement of unserviceable hings and all drop bolt , complete and painting with one coat of synthetic enamel paint of approved colour internally and externally complete all as specified and directed
Maintenance of indoor sub stations, including cleaning of premises and surroundings upto 5m from outer face of wall, checking of oil level of transformers, cleaning and dusting out of transformers, panel boards, cleaning of earth pits to keep free from vegetation etcComplete all as specified and directed.
All as per item No 56 herein before but for out door sub stns including levelling of loose filled aggregate around s/s.
Supply and fixing in repairs of mild steel galvanised stay assembly set complete comprising of 20mm dia, 400mm long stay bow, 1800 mm long stay rod 20mm dia, (300mm x 300mm x 6mm) stay plate, thimble, GI stay wire of 7/8 SWG upto required length including loop type insulator of vitreous porcelain, small size with overall dimensions (90x140)mm, clearance of hole 25.5mm, all as shown in electrical plate No.1 of MES Schedule part-I 2009 Complete all as specified and directed.
M&L for replacement of blown out DO fuse, 33/ 11 KV grade of any capacity consisting of 20 pieces Complete all as specified and directed.
Material and Labour for in replacement Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, (20x15)cm size for HT,(25X20)cm size Complete all as specified and directed. by Engineer-in-charge.
Cleaning and preparation of old painted surface of LT PCC street light pole up to 1.50 mtr height from top of PCC foundation block, making alternative black and white strips on pole with Radiant paint (each strip 30cm high) and writing pole nos. including applying one coat of cement base paint on exposed surface of PCC coping and foundation blocks complete all as specified and as directrd by Engineer-in-charge.
Supply, installation, testing and commissioning out door type LT panel board ,made out of 3.15mm thick CRCA sheet , factory made, cubical type,with slanting top at leaset 10 Cm projection all around, fedder pillar type,fabricated with (50x50x6)mm angle iron frame work with independent door for each feeder,busbar chamber cable tray on both side fully compartmentlized design, double door type & commen openable hinged door from rear side, floor mounting type, busbars made of aluminium duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours.Bus bar shell be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for connecting suitable earth strips,painting with one coat of anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), Confirming to IP 54 protection and confirming relavent IS, comprising the adequate arrangement to supply & fix the following accessories,including connecting cable glands and cable lugs,fixing of earth lead to earth terminal of panel including necessary excavation & PCC foundation complete all as specified & Directed by Engr-in-Charge.( Note:- Cost of all accessories are deemed to be included in the rate quoted) .
Incoming (a) Aluminium bus bar - 600 Amps rating - 03 Nos. for phases and 150 Amp rating - 01 No. for neutral
(b) MCCB 4 pole 400 Amps, 415 volt, 36 KA - 01 No ( incoming)
(e) ON/OFF LED type indication lamp with toggle switch - Set of 03
Out going:- (a) MCCB 3 pole 250Amp, 415 volt, 36 KA - 02 No
(C) MCCB 3 pole 100 Amp, 415 volt, 36 KA - 03 Nos
M&L for Earthing complete with galvanised steel earth plate electrode (60×60cm).× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion Complete all as specified and directed.
S.S. Engineers
AGARWAL BUILDERS
Vinayak Trading House
ENVIRO TECH SERVICES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .