| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | ₹1.4 Cr | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹1.5 Cr+₹5.1 L (3.55%)Rejected-Finance | ₹1.5 Cr+₹5.1 L (3.55%) | L2 | Rejected-Finance BEING NOT LOWEST TENDER |
| 3 | L3₹1.5 Cr+₹5.3 L (3.70%)Rejected-Finance | ₹1.5 Cr+₹5.3 L (3.70%) | L3 | Rejected-Finance BEING NOT LOWEST TENDER |
| 4 | L4₹1.5 Cr+₹6.2 L (4.31%)Rejected-Finance THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | ₹1.5 Cr+₹6.2 L (4.31%) | L4 | Rejected-Finance BEING NOT LOWEST TENDER |
| 5 | L5₹1.5 Cr+₹6.4 L (4.47%)Rejected-Finance | ₹1.5 Cr+₹6.4 L (4.47%) | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
₹1.5 Cr
EMD Value
₹2.3 L
Closing Date
13 Sept 2021, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
COMPREHENSIVE MAINT OF SEWAGE TREATMENT PLANT OF CAPACITY 1 MLD, ATTENDING DAY TO DAY WATER OVERFLOW, LEAKAGE RELATED COMPLAINTS, REPAIR/ MAINT OF WATER SUPPLY DISTRIBUTION SYSTEM, STARTER, SWT, DUG SHALLOW WELL AND OTHER MISC WORKS AT AFS SULUR
2021_MES_468872_1
8440/E8
Open Tender
Miscellaneous Works
Item Rate
334 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Yes
GE AF SULUR
₹2.3 L
Yes
18 Sept 2021
17 Aug 2021
14 Sept 2021
17 Aug 2021
13 Sept 2021
7 Sept 2021
17 Aug 2021 - 6 Sept 2021
Amount
SCHEDULE A BOQ
Comprehensive maintenance/repair of sewage treatment plant of capacity of 1 MLD, the plant comprising of the following assets :- Main collection tank of 2,00,000 ltr capacity, submersible sewage cutter pump of capacity 7.5HP 3 phase 415V-02 No, Air compressor 15HP 3 phase 415V-03 No, treated water monoblock pump set 15HP 3 phase 415V-02 No, treated water submersible type motor 7.5HP 3 phase 415V-02 No, clarifier motor and gear 02HP 3 phase 415V-01 No, Activated carbon filter tank with assembly-01 No, sand filter unit-01 No, settling tank-01 No, Aeration tank-02 No, treated water sump of 5000 ltr capacity-01 No, chlorine tank of 20000 ltr capacity -01 No, secondary clarifier-01 No, sludge drying bed divided into 04 No compartment-01 No, PLC based fully automatic SCADA panel-01 No, motorised valve 100 mm-04 No, LT panel with motor controller-01 No, Recycling pump 5HP,3phase, 415 volts-02 Nos and other civil structures/ chambers, connected equipments, control panel board and cables etc.
(I) The parameters of input and output shall be maintained as under :-
(a) Inlet parameters :- (i) BOD - 250 - 275 mg/ltr (ii) COD - 400 - 550 mg/ltr (iii) TSS - 400 mg/ltr (iv) PH - 7 to 7.5 (v) Fecal Coliform - < 230
(b) Parameters for treated sewage effluent required are as :- (i) BOD - Less than or equal to 10 mg/ ltr (ii) COD - Less than or equal to 150 mg/ ltr (iii) TSS - < 30 mg/ltr (iv) PH - 7 to 8 (v) E coli - Less than or equal to 100 counts/ 100 ml (vi) Residual chlorine - > 0.5mg/ ltr (iv) DO (Dissolved oxygen level - 2 to 4 mg/ ltr in biological system to be maintained)
(II) The following daily maintenance to be carried out :- (a) Bar screen chamber should be cleaned every day to ensure that it’s not choked. (b) Cleaning of Oil & Grease trap. (c) Once in every two hours pumps should be changed between working and standby i.e, Sewage feed pump, blower and Filter feed pump. (d) Maintain disinfection liquid in chlorine dozing tank. (e) MGF and ACF back wash & rinse – Once in every 8 hours simultaneously. (f) Settling tank – Sludge should be disposed from settling tank to sludge drying bed. Once every 8 hours based on MLSS growth. (g) Monitoring and maintenance of log books periodically. (h) Treated water tank – chlorine content should be analysed to ensure that chlorine residual is below 0.2 ppm. (j) MLSS growth – to be checked in aeration tank and equalization tank for proper growth
(III) The following weekly maintenance to be carried out :- STP system is inspected weekly and the following points attended to :- i) Inspect Equalisation Tank/ Entry to system for blockages, plastics etc and remove. ii) Inspect Aerator and note biomass growth, recirculation flow and if any malodour,it is to be treated. iii) Inspect Secondary clarifier (Humus, Tank) and note visual appearance of final effluent and absence (or otherwise) of sludge build up. iv) Check the outlet of the system for blockage etc. v) Check water level in grease trap and if required top up with clean cold water. vi) Grease the bearings (vii) Grease all chain couplings through casing nipples. (viii) Drain out and replace gearbox oil of superior quality (ix) Check holding plate bolts. (x) Check shaft for wear and alignment. (xi) Check bearings for wear and tear and check holding down bolts for tightness. (xii) Check chain coupling and check bolts for tightness.
(IV) The following monthly maintenance to be carried out :- Aerator MUST BE SWITECHED OFF during monthly maintenance procedures. i) Check motor for overheating (by touch) and remove dust etc. from air fins. ii) Grease all bearings through nipples. iii) Grease all chain couplings through casing nipples. iv) Check oil level in gearbox and top up if necessary. v) Check sludge return system from Humus Tank for function. vi) Apply light lubricating oil in small quantities to locks and hinges. vii) Empty and clean out grease trap and fill with clean cold water. viii) Preparing and submitting monthly report on performance of the plant. ix) Sludge disposal outside the MD land atleast once in a month. x) Check and calibrate the instruments including on line monitor and submit report. xi) Check dozing pump and repair/service if necessary.
(V) The following items for routine maintenance shall be provided in plant :- (a) Liquid chlorine with suitable % of chlorine concentration as recommended by manufacturer - 350 ltrs per month (b) Urea - 250 kg per month (c) DAB - 200 kg per month (d) Bio culture - 60 kg per month (e) Cow dung - 500 kg per month (f) Deforming chemical - 30 ltr per month (g) INDI foam 3000 - 60 ltr per month (h) Sercon 203 - 45 ltr per month
(VI) The following items shall be replaced as and when required or as directed by the Engr-in-Charge :- (a) Gaskets, Gland Packing. (b) O rings. (c) Drive belts for air blower and clarifier. (d) Minor electrical accessories viz Indication lamps, fuses etc. (e) Blades (f) Pasting materials (g) Consumables like gloves, safety jackets, helmets, respirators etc (h) Cleaning Chemicals, reagents, Lubricants etc. (j) Contractor shall ensure the filter media particles are upto the level in ACF and MGF. If the quantity level reduces due to loss during filtration and back wash, the same should be toped up during routine maintenance.
(VII) The following tests shall be carried out and maintain the record of treated sewage as per frequency mentioned below :- Ser No Description of parameters Periodicity 1. PH ON line/ real time 24 hrs 2. TSS ON line/ real time 24 hrs 3. BOD ON line/ real time 24 hrs 4. COD ON line/ real time 24 hrs 5. Coliform Daily 6. Residual chlorine Daily 7. Dissolved oxygen Daily
Note for item No 2 :- The unit quoted rate shall be deemed to be inclusive of the following :- (a) The contractor shall visit the site/ plant before quoting the tender. The existing STP plant is MBBR and Original Equipment Manufacture is M/s ION Exchange.
(b) To provide technical support for comprehensive maintenance of STP, the contractor shall enter MOU with the OEMs. No additional payment on this account shall be made to the contractor by the department.
(c) Irrespective of the fact that MOU is signed by contractor with an OEM, contractor will be fully responsible for overall performance and quality of treated water coming out after treatment.
(d) The comprehensive maintenance of STP plant of MBBR will be carried out through authorised rep of the OEM's only under the supervision of contractor and the Engineer-in-Charge. The authorised service agency of OEM shall be responsible to provide all technical support for comprehensive maintenance and shall also be responsible for performance of the plant in terms of outlet parameters mentioned here-in-before.
(e) OEM or their authorised service centre shall employ round the clock minimum one technician having sound knowledge in STP Plant to operate the plant, carryout water analysis checks through approved Laboratory and monitor the performance of the plant on a regular basis, interpret the results and suggest remedial measures in case of major deviations and one person for daily maintenance and cleaning of the plant.
(f) Arrangement for On line/Real time monitoring of COD, BOD, TSS, Disolved Oxygen, PH values shall be done by the contractor for performance monitoring of parameters on a regular basis.
(g) Service Engineer of OEM shall visit at least once in every month and during break down or when urgently required for the Inspection, servicing repair, rectification of problem and submission of report.
(h) The contractor shall be fully responsible for maintaining the STP in operational condition in consultation with the Engineer-in-Charge.
(j) The cost of supply and replacement of worn out/ defective equipments, each and every type of repair, renewals, regular servicing for efficient and smooth functioning of STP and connected equipment/ items shall be deemed to be included in the unit quoted rates of BOQ.
(k) Repair/ replacement of any equipment/ machinery or part thereof provided under this contract shall be got done only from the manufacturer's authorised dealer/ OEM and record there of shall be maintained.
(l) The contractor has to provide all consumable spares, oil & lubricants for greasing of various equipments, chemicals, consumables for electrical and mechanical plant & machinery.
(m) One month's consumables and required spares shall always be kept at site in advance.
(n) Major repairs/ overhauling etc. shall be notified to the GE immediately on occurrence. The cost of each part/ equipment replaced shall be deemed to be included in the unit rates quoted by the contractor. The unit quoted rate shall be deemed to be included for all materials and labour reqd for comprehensive maintenance including repair/ replacement of any defective component/ equipment to keep the STP in operational condition at all the time.
(o) The entire treated water will be reutilised for arboriculture purpose/ flushing system of toilets. The quantity of treated water shall meet all the criteria given here in before.
(p) The contractor shall carry out various tests on treated sewage and record the same in registers duly signed by contractor's rep, JE and Engineer-in-Charge. The tests shall be carried out from Govt approved laboratories. Contractor shall also be at liberty to establish his own laboratories at site for same after prior approval of GE, however, GE can ask the contractor to get independent tests from Govt lab/ Govt Engineering colleges. The cost of above shall be deemed included in the rates quoted by contractor in BOQ.
(q) The Installation shall be frequently visited by the MES/ Air Force officers. It shall be contractor responsibility for proper upkeep of the area in a presentable state all the time. Surrounding area upto the fencing/ boundary of STP shall be kept clean and cleared of bushes/ shrubs and grass all the time to give a neat and clean appearance of the area.
(r) Registers of record of periodical maintenance carried out date wise for each equipment separately and the same shall be signed by both parties i.e authorise rep of contractor, JE and Engineer-in-Charge.
(s) Repair to system in case of break down (due to normal wear & tear) shall be rectified by the contractor within 24 hrs. In case of failure noticed more than 24 hrs, recovery shall be effected @ Rs. 500/- per hour beyond 24 hrs.
(t) All sludge at suitable frequency (atleast once in a month) shall be disposed off outside the defence land. It will be the responsibility of the Contractor to identify the area suitable for disposal of sludge. The cost of same deemed to be included in the unit quoted rate.
M&L for repair/maint of Sand Filter of 1 MLD Sewage Treatment Plant, including replacing of sand & silex by opening top cover of sand filter tank and removing used sand and silex from Sand Filter Tank and washing/ cleaning the tank neatly & properly, and re- filling with new Fine Sand (400 Kgs), Coarse Sand(1500Kgs), Fine Silex(400kg) and Coarse Silex( 400 Kgs) in proper layers as per requirment and closing top cover of the Sand Filter Tank properly and check all connections complete all as directed by Engineer-in-Charge.
Supply only MBBR Media in the Bio culture tank of STP Plant. Make : ION Exchange Cat No. MB1622 or its equivant as approved by GE complete all as specified and directed
M&L for repair/maint of Activated Carbon filter of 1 MLD Sewage Treatment Plant, including replacing of Carbon by opening top cover of Carbon filter tank and removing used old Carbon from Carbon filter tank and washing/ cleaning the tank neatly & properly ,and re- filling with new Activated Carbon 900 IV (625 Kg) as per requirment and closing top cover of the Carbon filter tank properly and check all connections complete all as directed by Engineer-in-Charge
Construction of sewage water pre filter collection chamber/ sludge recirculation pre filter collection chamber of 1200mm x 2000mm x 1500mm internal size suitable for Sluice Valve, with 150 mm thick PCC 1:4:8, Type D2, using 40mm graded aggregate for foundation, 200 mm thick Brickwork with Fly Ash Bricks in Cement Mortar 1:6, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as specified.
Disconnecting electric connection and taking out submersible sewage cutter pump set of capacity 7.5 HP, 3 Phase, 415 volt from sewage well, transport to the workshop and back for making the serviceable/ repair, dismantle the motor/pump, taking out burnt winding of stator, removal of burnt insulation material from the slot, cleaning the stator slots and M&L for rewinding the stator using super enamelled, submersible grade copper winding wire of same gauge and turns, cleaning and overhauling the pump, tightening impeller complete including replacing the following unserviceable spares, reinstall the pump in original position and testing at full load capacity all as specified and directed by Engineer-in-Charge. Make : Kirlosker Location : Gulmohar Collection Sump Note: The replacement of spares will be measured and paid separately as supply only.However, cost of labour for replacement is deemed to be included in the unit rate quoted.
Supply only Coil wound set with class "F" insulation
Supply only Ball Bearing Set
Supply only "O" Ring & gasket set
Supply only Mechanical seal lower
Supply only Mechanical seal upper
Supply only Fastner Set
Supply only Rotor rework with S.P Sleeve with balancing
Supply only Impeller balancing work.
Rectification of leakage of GI pipe diameter 80 to 100mm in trench after carry out excavation upto volume of 2 cum, replacement of unserviceable pipe fittings like collar, bend, Tee, Reducer, etc, including threading of existing pipe, applying all necessary engineer effort to check the water leakage, carryout necessary earth works to closs the trench and remove surplus soil upto 50 mtr distance all as directed
Cleaning of valve pit chamber for sluice/gate valve of 50/80/100/150/200/ size by removing mud/ grass/ sludge/ other waste materials from the chamber and from surroundings upto 1mtr distance, carryout petty cement repairs with cement mortar 1:4, apply one coat of white wash on cemented surfaces and one coat of synthetic paint on steel surfaces complete to make an operator friendly valve chamber complete as specified and directed. Note :- Periodicity and locations of valve chambers will be given as per requirement by the Engineer-in-Charge.
Opening of existing sluice valve of 200mm bore by dismantling from existing water line and opening of gland cover taking out with spindle with check nut of stainless steel & refixing the same after servicing, greasing including replacement of rubber packing, nuts & bolts, glands etc and to refixing on the same line complete all as specified and directed Note: Any new parts like stainless steel Spindle with check nuts,Gland plate of required size shall be measured and paid separately under respective items
Opening of existing sluice valve of 150mm bore by dismantling from existing water line and opening of gland cover taking out with spindle with check nut of stainless steel & refixing the same after servicing, greasing including replacement of rubber packing, nuts & bolts, glands etc and to refixing on the same line complete all as specified and directed Note: Any new parts like stainless steel Spindle with check nuts,Gland plate of required size shall be measured and paid separately under respective items
Supply only 200 mm bore stainless steel spindle with check nut, gland plate complete all as specified and directed.
Supply only 150 mm bore stainless steel spindle with check nut, gland plate complete all as specified and directed.
Supply and fix CI foot valve 150mm dia to suction line of exisiting pumping set with bolts, nuts, rubber packings, etc including taking out old unserviceable one by dismantling suction pipe from pump set all as specified and directed.
S&F in repairs DI fittings Bend,(any type ,radius and angle) tapers any type (straight, bend,increasing,decreasing or double socket etc), Tee pieces, connection pieces, collers, caps and plugs complete all as specified and directed
S&F Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class "K-7" for 150mm bore with Socket and Spigot ends conforming to IS - 8329 in standard lengths suitable for Push-On Rubber Gasket Jointing with inside Cement Mortar Lining and Black Bitumen external coating including taking down any description and any size of pipe complete all as specified and as directed. Note : Excavation earth work and DI special shall be measured separately.
Attending day to day water supply service related complaints like choking of rising main pipes of buildings, blockage in control valves/ float valves/ pipe fittings, etc, applying necessary engineering efforts like dismantle of pipes and fittings to clean and remove blocking objects, descaling of pipes, re-fixing of pipes on wall, etc to restore the proper flow of water to service tanks all as specified and directed by Engineer-in-Charge.
Note for item No 53 :- (a) The contractor has to attend above mentioned job in any location of entire domestic and tech area of Air Force Stn Sulur.
(b) The service tanks are positioned on roof top of multi storied buildings upto four storey. Contractor is responsible to ensure that the labour employed should be equipped with safety items like industrial helmet, safety belt, extensible ladder of 40 feet length, plumbing and cuttings tools, etc.
(c) The cost of rethreading of GI pipes of 25mm dia and adding of new GI nipple of suitable length after rethreading is deemed to be included in the quoted rate.
(d) Due to shortage of water in the station, the repair work and testing required under this item need to be carried out during water supply distribution hours i.e. 5:30 AM to 7:30 AM. Nothing extra shall be permitted in this regard.
(e) The cost of repair to the damages of cemented surfaces/ external finishes/ metal clamps of rising pipes are also deemed to be included in the quoted rate.
(f) In case of any delay in attending the complaint more than 6 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(g) If the delay is more then 06 hrs period and GE is not satisfied with the reason for delay then penalty at the rate of Rs 100/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
(j) The decision of the Accepting Officer in this regard shall be final and binding.
S&F Gun Metal gate or globe valve with iron wheel head screwed both ends for iron pipes and of 50mm dia bore including fixing accessories and taking down unserviceable Gun Metal gate valve from existing places complete all as specified and directed.
S&F PVC water storage tank cover suitable for 500 to 1000 ltrs capacity tank with locking arrangement complete including taking down of existing one all as specified and directed
S&F PVC water storage tank Nipple of 25mm bore with suitable check nut for inlet/outlet connection including taking down of existing one all as directed.
S&F Rotational moulded polythene water storage tank of 500 Ltrs capacity (three layer white colour) cylinderical vertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I including taking down of old unserviceable tank complete all as specified and directed.
S&F Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and pipe and fixed for 20 mm dia bore and including taking out unserviceable ball valves complete all as specified and directed.
S&F 3-layer PP-R (Polypropylene random copolymer) pipes of 32 mm outer dia of pipes, concealed SDR 7.4 (PN-16 @ 20°C) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, including taking down existing pipe of any description and bore of pipe complete to walls, ceilings or in floors or in trenches etc. of following size all as specified and directed. Make : SFMC, Prince, KPT
Supply and fixing PP-R Gate Valves (Brass insert) 32 mm outer dia with iron wheel head screwed both ends for iron pipes and including taking out unserviceable Gate valves complete all as specified and directed.
Cleaning of UG open static Water Tank (SWT) of the following capacities by involving of the followings 07 (Seven) stage of cleaning process complete all as specified and directed (i) De-watering by high pressure submersible pump all complete (ii) Removal of sludge/mud/slit/sand from sump and disposal out side MD land (iii) Cleaning of walls, floors, ceiling etc by high pressure jet pump 80-180 bar pressure all complete (iv) Removing dirt and sludge by vacuum pump (v) Applying one coat of white wash internal surfaces. (vi) Replacenylon net for vent pipes & man hole cover (vii) Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etc Note : The contractor shall arrange mobile generator for operation of dewatering by high pressure submersible pump (or) Diesel driven high pressure pump and the unit quoted rate is inclusive of rent/hiring charges complete.
15000 Gallons capacity, Approximatly Inner diameter 19 Feets to 20 Feets and outer dia 22 Feet to 23 feet
10000 Gallons capacity, Approximatly Inner diameter 16 Feets to 17 Feets and outer dia 18 Feet to 19 feet
Note for Item No 69 to 71 :- (a) Dewatering pump of suitable capacity shall be arranged by the contractor. (b) Material removed from the UG sumps/OHT's shall be deposited off at a distance of 50 mtrs away from. (c) UG sumps/OHT's shall be made available for cleaning for a period of 08 hours only. (d) Contractor has to arrange sufficient labour/T&P to complete the job with in the given period only
Supply of calcium based high strength chlorination chemical for water in granular form chlorine concentration level having 65%-70% Chlorine content packed in 45 Kg capacity in factory sealed HDPE Container superior quality suitable for treatment of drinking water complete all as specified and directed Make : Declibac /Potter and watts/Purichlor/ Sree Rayalseema Hi strength Hypo Ltd or any other E-in-C's approved make.
Note for item No 73 :- (i) Approval of chemical (Calcium hypochlorine) will be given after verification of test certifiate of chemical of various manufacture and other factor like chemical and safety and health hazard aspect of usage of chlororonation. (ii) The branch/make of the chlorination of chemical must be sealed in production and certified by Govt laboratory confirming compliance of specification suitable for dring water with a declaration from the laboratory that from the technical strength, stability, health safety and operation point of view this product is used for drinking water applications for consumption by humans and the brand.make of calcium hypochorite is suitable for drinking water chlorination and its sample has been tested by Govt Laboratory.
Removing of acumulated earth of any width and depth up to 30 cm. cleaning/cutting the grass and removing the grass waste to outside MD land. Note :- The unit rate is deemed to be included for the following :- (a) Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked. (b) Cutting the grass/falling of trees shall include digging out roots up to 60 cm below the ground level or 14 cm below the formation level, whichever is lower. All holes and hollows formed in the ground digging out of roots shalll be carefully filled up with moorum/red bajri well rammed and levelled.
Taking down defective centrifugal pump set 60 HP to 83 HP capacity by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. (Supply of spare parts shall be measured and paid for separately under respective items here-in-after). Make of Pump : Kirloskar Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 1000 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 60 HP to 83 HP capacity motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling bolt with nuts suitable for 60 HP to 83 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 60 HP to 83 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 60 HP to 83 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 60 HP to 83 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 60 HP to 83 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Remetalling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 60 HP to 83 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 60 HP to 83 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 60 HP to 83 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
S&F Power contactors 3 pole, AC 3 phase 40 Amps,with aux contacts 2 NO+2NC complete including taking down existing one all as specified and directed. MAKE : SCHNEIDER/ LEGRAND/ L&T
S&F MPCB, TP 100 Amps with suitable wiring for stater control panel including taking out unserviceable worn out MPCB complete all as specified and directed. MAKE : Larsen & Toubro, Schneider , ABB
S&F Single phase preventer with suitable wiring for stater control panel including taking out unserviceable worn out single phase preventer complete all as specified and directed.
M&L Excavation in trenches not exc 1.5m wide and not exc 1.5 mtr depth for laying cable, pipes etc and not exc 10 sqm on plan and getting out in hard/ dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil complete all as specified and directed.
Removing of excavated material exc 1.5 KM but n exc 5 KM and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Cutting existing road/PCC/Drain for laying of DI/GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate complete all as specified and directed.
Note for item No 92 :- The tenderer shall take into consideration for following points while quoting his rate for this item and the unite rate is deemed be included for :-
(i) Earth work excavation in any type of soil
(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.
(iii) Removing excavated material to out side MD land
(iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately
(v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces.
S&F 110 mm outer dia of pipe of 3 Layer PP-R Polyproplyne random copolymer concealed SDR 11 (PN 10) UV stabilized and antimicrobial fusion welded havIng thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropyelene random fittings fixing complete to walls, floors, ceilings, under trenches including taking down of existing GI/CI unserviceable pipes complete all as specified and directed. Make : SFMC, Supreme, KPT.
Note for item No 99 :- (a) The unit rate shall be included for taking down existing GI pipe and connections and all fittings as directed.
(b) The unit rate shall include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
(c ) Wall thickness of pipes shall be all as per IS : 15801
S&F PP-R Gate Valves (Brass insert) 110 mm outer dia with iron wheel head screwed both ends for iron pipes and including taking out unserviceable Gate valves complete all as specified and directed.
Supply only 110 mm outer diameter of pipes in cutting road portion 3 Layer PP-R Polyproplyne random copolymer concealed SDR 7.4 (PN 16 @ 20°C) UV stabilized and antimicrobial fusion welded havIng thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropyelene random fittings complete Note : The unit rate is included for supply only and cutting existing road , excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 as in road will be measured and paid separately
Construction of Valve Chamber of size 1000 X 1000 X 1000 mm internal size suitable for Sluice Valve, with PCC 1:4:8, Type D2, using 40mm graded aggregate for foundation, 230 mm thick Brickwork with old size Fly Ash Bricks in Cement Mortar 1:6, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as specified.
S&F Sluice Valve, Cast Iron body, Stainless Steel Spindle, Gun Metal Rings including Wheel for operation, Flanged and Drilled, suitable for 150 mm dia pipes, confirming to IS - 14846, Class PN -1.6, Long Body type including all Joints with Rubber Gasket and Jointing Materials, Bolts, Nuts, Washer complete including taking down existing UNSV sluice Valve all as specified and as directed.
S&F Butterfly valves of 150mm bore including joints with rubber gasket and jointing materials bolts, nuts, washers, including taking out existing unserviceable butterfly valve complete all as specified and directed
Opening of existing sluice valve of 100mm bore by dismantling from existing water line and opening of gland cover taking out with spindle with check nut of stainless steel & refixing the same after servicing, greasing including replacement of rubber packing, nuts & bolts, glands etc and to refixing on the same line complete all as specified and directed Note: Any new parts like stainless steel Spindle with check nuts,Gland plate of required size shall be measured and paid separately under respective items
Supply only 100 mm bore stainless steel spindle with check nut, gland plate complete all as specified and directed.
Supply, install, testing and commissioning of outdoor type Factory fabricated motor starter panel suitable for 3 phase 415V, 50Hz system made out of CRCA sheet with suitable neoprene rubber gasket to make it completely, dust and vermin proof, front openable type alongwith locking arrangement having angle iron base frame and legs of suitable size, PCC (1:3:6) bedding for grouting of base including dismantling and taking out old unserviceable panel, complete all as specified and directed. The panel shall comprise the following accessories and specifications :- (a) MCCB 4 pole, 32 Amps, 16 KA - 01 No (Incoming) (b) Star-delta starter suitable for 10 HP submersible motor pump set incl timer- 01 Set (c) Motor protection relay - 01 Set (d) Single phase preventor - 01 Set (e) Phase indicating LED lamps RYB - 01 Set (f) Panel mounted multifunction meter including CTs of suitable ratio - 01 Set (g) ON/ OFF push button alongwith indication light - 01 Set (h) Electrolytic high conductivity insulated copper bus bar of suitable capacity - 01 Set (j) Complete control wiring of the panel (k) Earthing terminals - 02 Nos
Cleaning of service tanks of the capacity as mentioned below on roof top of bldgs upto five storey after disconnection from inlet and outlet pipe, removing of float valve of service tank and keep aside safely for reuse drain out water through drain plug, cleaning thoroughly to remove all scales and dirt by brushing internal surface, cleaning properly inside with soda wash, flushing out with fresh water, re-positioning of tank at same place, re-connecting inlet and outlet pipes, closing of drain plug, re-installation of float valve duly cleaned, writing/ labelling the record of cleaning carried out with white bold letter such as "TANK CLEANED ON"--------- (month and year), including removing creepers, vegitation and roots of plants, trees branches on or surrounding of service tank complete all as directed. Note:-(i) Unit rate quoted is deemed to be included for testing of water supply in tank both inlet and outlet flow during next supply hours early in the morning or late in evening. (ii) Contractor shall maintain a pucca bound register for cleaning carried out with date and obtain users signature and remarks if any and this register to be submitted alongwith RAR. (iii) Contractor is liable to rectify any damages to the external finishes of the bldg occured during the cleaning process, i.e. scrubbing and touch up with external paints as existing specifications. Unit rate quoted is deemed too be included the cost of the same. (iv) All sort of petty T&P items such as ladder, safety equipment, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept.
(a) For masonry /PVC tank exceeding 250 liters and not exceeding 500 ltrs
(b) For masonry /PVC tank exceeding 500 liters and not exceeding 1000 ltrs
(c) For masonry /PVC tank exceeding 1000 liters and not exceeding 2000 ltrs
(d) For masonry /PVC tank exceeding 2000 liters and not exceeding 4000 ltrs
Cutting and removing existing rusted and damaged OH tanks hand rails with stand posts and material and Labour fabricate for Compound girders and stanchions, lattice girders, aerial masts, staging of water tank and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc with Fe 410 -W (Gde- E- 250), with square /round or any shape and sizes of MS pipe including two coats of synthetic enamel painting over a coat of red oxide primer, with scaffolding complete all as specified and directed.
M&L PCC (1:3:6) type C1 using 20 mm graded stone aggregate as in base foundation for the pipe lines including one coat of white wash and necessary form work complete all as specified. Note:- Quoted rates is inclusive of removing the damaged PCC base foundation, levelling surface as per direction of EIC complete.
S&F Rotational moulded polythene water storage tank of 1000 Ltrs capacity (three layer white colour) cylinderical vertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I including taking down of old unserviceable tank complete all as specified and directed.
S&F PVC water storage tank cover suitable for 1000 to 2000 ltrs capacity tank with locking arrangement complete including taking down of existing oneall as specified and directed
S&F Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and pipe and fixed for 25 mm dia bore and including taking out unserviceable ball valves complete all as specified and directed.
S&F Gun Metal gate or globe valve with iron wheel head screwed both ends for iron pipes and of 40mm dia bore including fixing accessories and taking down unserviceable Gun Metal gate valve from existing places complete all as specified and directed.
Taking down defective centrifugal pump set 25 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing capacity at least for 8 hrs on load, complete all as specified and as directed. (Supply of spare parts shall be measured and paid for separately under respective items here-in-after). Make of Pump : M/s BE Pvt Ltd/ Kirloskar Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 1000 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling Rubber Bush suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling bolt with nuts suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 25HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply, installation, commissioning and testing of Factory assembled, Floor mounted, free standing, type tested LT Feeder Pillar Panels, with canopy, as per electrical specifications for outdoor installation, to be made of IP65 Polycarbonate modular enclosures. The Enclosures made of Polycarbonate, should be weather/ vermin proof, anti-acid, anti-corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The manufacturer of boards/panel shall submit a copy of type test reports as per above-mentioned norms either from UL/ERDA/CPRI/NABL labs in India. The panels should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosures should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with 01 No polycarbonate IP 65, 9W LED translucent bulk head luminaire, 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with 01 No of 16A 3P IP 65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 phase and neutral 400 amps current carrying capacity copper bus bar insulated with colour coded heat shinkable sleeves with SMC/DMC insulators, complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above ground level, including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :-
Supply and fix CI foot valve 100mm dia to suction line of exisiting pumping set with bolts, nuts, rubber packings, etc including taking out old unserviceable one by dismantling suction pipe from pump set all as specified and directed.
Disconnecting the delivery pipe line of submersible pump sets of any capacity from water mains to take out by lifting column pipe of 50mm dia alongwith submersible cable and pump set from shallow well of any depth for servicing of submersible pump sets of any capacity at site, re-assembling the column pipe and re-connection of submersible cable with pump set and lowering in the shallow/open well, testing and commissioning all as specified and directed. Note:- (a) The cost of tools and equipments reqd for lifting/ lowering of pipes and pumps are deemed to be incl in the quoted rate.
Dismantling pump and motor of submersible pump set for capacity 3 HP to 5 HP to carry out repairs and replacements at local workshop, duly replacing worn out parts, applying one coat of spray painting with synthetic enamel paint of existing colour and testing complete all as specified and directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 200 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only GM Bush.
Supply only sleeve MS key for impeller
Supply only SS coupling bearing.
Supply only oil seal thrust bearing.
Supply only Sand Guard.
S&F Flat Three Core PVC Insulated & PVC Sheathed Industrial Cable for Submersible Pump Motors 1100 Volt, conforming to IS 694, 4 sqmm nominal area complete including taking out old unserviceable cable complete all as specified and directed. Make : Havells/ Polycab/ Finolex
Supply, install, testing and commissioning of outdoor type Factory fabricated motor starter panel suitable for 3 phase 415V, 50Hz system made out of CRCA sheet with suitable neoprene rubber gasket to make it completely, dust and vermin proof, front openable type alongwith locking arrangement having angle iron base frame and legs of suitable size, PCC (1:3:6) bedding for grouting of base including dismantling and taking out old unserviceable panel, complete all as specified and directed. The panel shall comprise the following accessories and specifications :- (a) MCCB 4 pole, 32 Amps, 16 KA - 01 No (Incoming) (b) Star-delta starter suitable for 7.5 HP submersible motor pump set incl timer- 01 Set (c) Motor protection relay - 01 Set (d) Single phase preventor - 01 Set (e) Phase indicating LED lamps RYB - 01 Set (f) Panel mounted multifunction meter including CTs of suitable ratio - 01 Set (g) ON/ OFF push button alongwith indication light - 01 Set (h) Electrolytic high conductivity insulated copper bus bar of suitable capacity - 01 Set (j) Complete control wiring of the panel (k) Earthing terminals - 02 Nos
S&F 90 mm outer dia of pipe of 3 Layer PP-R Polyproplyne random copolymer concealed SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded havIng thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropyelene random fittings fixing complete to walls, floors, ceilings, under trenches including taking down of existing GI/CI unserviceable pipes complete all as specified and directed. Make : SFMC, Supreme, KPT.
Note for item No 142 :- (a) The unit rate shall be include for taking down existing pipe and connections and all fittings as directed.
(b) The unit rate shall be include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
(c ) Wall thickness of pipes shall be all as per IS : 15801
S&F 90 mm outer dia PP-R Gate Valves (Brass insert) with iron wheel head screwed both ends for iron pipes and including taking out unserviceable Gate valves complete all as specified and directed.
Supply only 90 mm outer diameter of pipes in cutting road portion 3 Layer PP-R Polyproplyne random copolymer concealed SDR 7.4 (PN 16 @ 20°C) UV stabilized and antimicrobial fusion welded havIng thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropyelene random fittings complete Note : The unit rate is included for supply only and cutting existing road, excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 as in road will be measured and paid separately
Construction of Valve Chamber of size 900 X 900 X 900 mm internal size suitable for Sluice Valve, with PCC 1:4:8, Type D2, using 40mm graded aggregate for foundation, 230 mm thick Brickwork with old size Fly Ash Bricks in Cement Mortar 1:6, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as specified.
Supply and fix, sluice valve with cast iron body and gun metal/steel spindle and hand operated iron wheel, both ends flanged and drilled including nuts, bolts, washers and gaskets, class PN 1.6, for 100mm dia bore pipe, including disconnecting, taking out old and removal, complete all as specified and directed.
S&F Butterfly valves of 100mm bore including joints with rubber gasket and jointing materials bolts, nuts, washers, including taking out existing unserviceable butterfly valve complete all as specified and directed
Rectification of existing defective flanged joints with rubber or fibre gasket complete with necessary nuts, bolts and washers for 100 mm dia GI/DI/MS pipes complete all as directed. Note:- a) quoted rates are inclusive of cutting of GI/DI/MS Pipes, jointing materials and preparation of new flanged sockets and refixing the same at existing place. (b) Necessary excavation shall be measured and paid separately under respective items of BOQ
S&F MPCB, TP 32 Amps with suitable wiring for stater control panel including taking out unserviceable worn out MPCB complete all as specified and directed. MAKE : Larsen & Toubro, Schneider , ABB
S&F 3 pole thermal over load relay AC 3 phase suitable for direct mounting on power contactors up to 42 Amps complete including taking down existing one all as specified and directed MAKE : SCHNEIDER/ABB/ L&T
S&F Power contactor 3 pole, AC 3 phase 25 Amps,with aux contacts 2 NO+2NC complete including taking down existing one all as specified and directed. MAKE : SCHNEIDER/ LEGRAND/ L&T
Labour for pressure testing of existing 150/80/50 mm DI/MS fire main system , identifying for leakages for rectifications including replacement of gland packing of sluice valves, rubber insertion packing, nut, bolts etc of flanged joints/ defective flanges etc complete for making the system leak proof complete all directed by Engineer-in-charge. Location :- SRE Bldg, ATC Bldg/ DWR Bldg. Note: (a) The rate quoted is deemed to be inclusive of T&P required such as air compressor etc for pressure testing (b) Earthwork, DI/MS pipe & specials required for rectiifcation, if any, shall be measured and paid separately under relevant items BOQ. (c) The pressure testing procedure of fire fighting system shall be done as per manufacturer's recommendations all as specified and directed.
Taking down existing fire fighting pipe line from the existing PCC pillar without any damage, for repair/ construct the new PCC pedastals, after completing PCC work refixing the same fire fighting pipe lines on PCC pedastals complete all as specified directed by Engineer-in-charge. Note :-(i) Quoted rates are inclusive of cutting/welding of MS pipes, and replacement of nut & bolts, rubber gaskets and necessary accessories complete. (ii) PCC work, excavation, removing of surplus soil shall be measured and paid separately.
Complete inspection, servicing, cleaning, oiling, greasing of following pumps/ valves/ connections complete with electrical/ engine, Diesel engine set 68 HP to 83 HP capacity making complete system functional including drainout used oil & replace Lub oil 20 W40 upto mark level, replace primary and secondary fuel filter element and Lub oil filter element of suitable size, replacement of old silenser suction bent pipe, head cleaning, tapet setting complete all as specified and directed by Engineer-in-Charge. Note :- Complete inspection, servicing, cleaning, oiling and greasing and above mentioned works of each item will be paid and measured separately as per the requirement at site here-in-after from item No 158 to 161.
Jockey Pump not less than 10 HP
Diesel Pump alongwith DG Sets
Main Pump of capacity not less than 60 HP
Terrace Pump centrifugal type of 10 HP capacity
Supply and fix in replacement of universal branch of size 25 mm dia suitable for coupling with CP hose pipe 63 mm dia as directed.
Supply and fix in replacement of unserviceable CP house pipe real 25 mm dia 36 mtr length including terminal brass jet as directed by Engineer-in-Charge
S&F Non return valve gun metal (ISI marked), PN 1.6 for 150mm dia bore pipe, including taking out old and removal, complete all as specified and directed. Make: Kirloskar/SANT/Zoloto
Supply and fix in replacement unserviceable iron sheet external cabinet made out of 18 gauge MS sheet of size 1000mmx1300mmx900mm on angle iron frame made out of 25x25x5mm and with mm thick tougnened glass door and locking arrangement to accommodate firefighting arrangements like Reinforced rubber lined hose reel 63mm dia of length 15mtr-2Nos and Gunmetal Branch Pipe short length-1No, First aid Fire Hose Reel 25mm dia of 36 mtr length-1No painting with two coat of synthetic enamel paint of fire red colour over a coat of red oxide primer for external and internally complete all as specified and directed by Engineer-in-charge.
S&F Pressure gauge 8" dial 0-14 Kgs rating including removing of old unserviceable. Make : Micro/ Fiebag/ Mamometer
S&F Reinforce rubber line hose reel 63mm dia and 15 mtr length as per standard specification including taking down existing one complete all as specified and directed.
Supply and fix in replacement of universal branch of size 15 mm dia suitable for coupling with CP hose pipe 63 mm dia as directed.
Cleaning of Semi UG sump of 30000 gallon capacity by involving of the followings 09 (NINE) stage of cleaning process complete all as specified and directed (i) De-watering by high pressure submersible pump all complete (ii) Removal of sludge from sump (iii) Cleaning of walls, floors, ceiling etc by high pressure jet pump 80-180 bar pressure all complete (iv) Removing dirt and sludge by vacuum pump (v) Anti- Bacterial Tratment of inside of tank which is effective against all pathogens all complete. (vi) Sterilization ofthe tank atomosphere by UV radiation inside of the tank. (vii) Applying one coat of white wash internaL surfaces. (viii) Replace nylon net for vent pipes & man hole cover (ix) Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etc. Location - ATC bldg
Note for item No. 169 :- The unit quoted rate is deem to be included for the following :- (i) The contractor shall arrange dewatering pump of suitable capacity and mobile generator for operation of dewatering by high pressure submersible pump (or) Diesel driven high pressure pump and the unit quoted rate is inclusive of rent/hiring charges complete. (ii) After cleaning filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked. (iii) Material removed from the tank shall be disposed off at out side MD land. (iv) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job with the given period only. or otherwise penality shall be imposed @ Rs 500/- per day.
Drain out existing contaminated water from open well/ dug shallow well of size 20 mtr x 10 mtr depth upto 20 to 35 mtr by pumping with the help of diesel driven pump set of not less than 20 HP and pipe complete, taking out of waste materials/ sludge, loose soil from bottom surface of well upto 2 to 3 mtr depth with the help of lifting trolley and further digging and getting out soil upto 1 mtr depth of bottom surface of well, removing grass and vegetation from inner walls of well including disinfection with high power sodium hypo chlorite liquid of not less than 60% chlorine concentration to disinfect all pathogens and coliform organisms from the wall surfaces and bottom surface of well to make a safe and clean spring in the well complete all as specified and directed by the Engineer-in-Charge.
Drain out existing contaminated water from open well/ dug shallow well of size 11 mtr x 11 mtr depth upto 20 to 35 mtr by pumping with the help of diesel driven pump set of not less than 20 HP and pipe complete, taking out of waste materials/ sludge, loose soil from bottom surface of well upto 2 to 3 mtr depth with the help of lifting trolley and further digging and getting out soil upto 1 mtr depth of bottom surface of well, removing grass and vegetation from inner walls of well including disinfection with high power sodium hypo chlorite liquid of not less than 60% chlorine concentration to disinfect all pathogens and coliform organisms from the wall surfaces of well to make a safe and clean spring in the well complete all as specified and directed by the Engineer-in-Charge.
Drain out existing contaminated water from open well/ dug shallow well of size 9 mtr x 4 mtr depth upto 20 to 35 mtr by pumping with the help of diesel driven pump set of not less than 20 HP and pipe complete, taking out of waste materials/ sludge, loose soil from bottom surface of well upto 2 to 3 mtr depth with the help of lifting trolley and further digging and getting out soil upto 1 mtr depth of bottom surface of well, removing grass and vegetation from inner walls of well including disinfection with high power sodium hypo chlorite liquid of not less than 60% chlorine concentration to disinfect all pathogens and coliform organisms from the wall surfaces of well to make a safe and clean spring in the well complete all as specified and directed by the Engineer-in-Charge.
Drain out existing contaminated water from open well/ dug shallow well of size 7 mtr x 3 mtr depth upto 20 to 35 mtr by pumping with the help of diesel driven pump set of not less than 20 HP and pipe complete, taking out of waste materials/ sludge, loose soil from bottom surface of well upto 2 to 3 mtr depth with the help of lifting trolley and further digging and getting out soil upto 1 mtr depth of bottom surface of well, removing grass and vegetation from inner walls of well including disinfection with high power sodium hypo chlorite liquid of not less than 60% chlorine concentration to disinfect all pathogens and coliform organisms from the wall surfaces of well to make a safe and clean spring in the well complete all as specified and directed by the Engineer-in-Charge.
Drain out existing contaminated water from open well/ dug shallow well of size 4 mtr x 3 mtr depth upto 20 to 35 mtr by pumping with the help of diesel driven pump set of not less than 20 HP and pipe complete, taking out of waste materials/ sludge, loose soil from bottom surface of well upto 2 to 3 mtr depth with the help of lifting trolley and further digging and getting out soil upto 1 mtr depth of bottom surface of well, removing grass and vegetation from inner walls of well including disinfection with high power sodium hypo chlorite liquid of not less than 60% chlorine concentration to disinfect all pathogens and coliform organisms from the wall surfaces of well to make a safe and clean spring in the well complete all as specified and directed by the Engineer-in-Charge.
Note for item No 171 to 175 :- The tenderer shall take into consideration following points while quoting his rate for these items and the unit is rate deemed to be included for :-
(i) The above mentioned job to be done in restricted technical area of Air Force Stn Sulur. The tenderer are advised to visit the site before quoting the tender. On account of security reason no compensation or extra shall be admissible due to any misunderstanding or loss of man-hours.
(ii) Due to acute shortage of water, open wells will be handed over to carry out the job in phase manner by Engineer-in-Charge throughout the currency of the contract.
(iii) The contractor shall be provide dewatering pump of suitable capacity and mobile generator for operation of dewatering by high pressure submersible pump (or) Diesel driven high pressure pump and the rate quoted rate is inclusive of rent/hiring charge complete.
(iv) An necessary T&P to ensure safely of labours like safety jackets, ropes, nets, helmets, gumboots etc required will be the responsibility of the contractor.
(v) The potability of water is to be checked after filling fresh yield after cleaning and if the result is found not within the stipulated range, the cleaning and disinfection of well is to be repeated by the contractor without claiming any extra cost from the deptt.
(vi) Charges for water testing will be measured and paid seperately under respective item.
(vii) Material removed from the tank shall be disposed off at out side MD land.
(viii) Open well/ Dug Shallow well shall be made available for cleaning for a period of 2 days only and contractor has to arrange sufficient labour/ T&P to complete the job with the given period only. or otherwise penality shall be imposed @ Rs 2000/- per day.
(ix) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract.
(x) The decision of the Accepting Officer in this regard shall be final and binding.
(xi) The unit rate is deemed to be included the cost of removing vegetaion/ grass/ trimming of tree branches etc from atleast 5 mtr surrounding of well and pumping room.
Arrangement of Chemical and bacteriological analysis of drinking water by collecting samples from different sources like UG sumps/ user end taps/ bore wells/ open wells/ etc located in 12 km periphery, collection of samples in sterrilized laboratory bottles/ cans, transportation to authorised Govt laboratory to deposit the samples in stippulated time, including payment of fees, collection and submit of reports to the Engineer-in-Charge complete all as directed.
Note for item No 188 :- (a) Cost of transportations for collection of sterrilized bottles from laboratory, deposition of collected samples in stipulated time, report collectiion after completion of tests, payment of fees to the laboratory for each sample, etc are deemed to be included in the quoted rate. (b) The rate quoted is considered to be for each sample. (c) Sample from different sources to be taken as per time schedule directed by Engineer-in-Charge throughout the currency of the contract. (d) Payment will be made after submission of report from authorised Govt laboratroy only.
Making arrangement to flush out the existing pipe line of any type 160 to 200 mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Making arrangement to flush out the existing pipe line of any type 110 to 150mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Note for item 190 & 191 :- (i) The Contractor is deemed to arrange necessary tools and equipments, removing or alteration of fittings from existing pipe lines, arragement of plugging devices, etc to build up specified pressure required to wash out the pipes. This will be inclusive in unit quoted rate. (ii) Excavation and earth work required will be measured and paid seperately. (iii) The flushing out will be carried out with fresh filled water of well only duly chlorinated with specified sodium hypochlorite solution to disinfect the pipe lines from all pathogens and Coliform organisms. Cost of same will be inclusive in unit quoted rate.
Excavation for taking out broken CI/DI pipe line upto 200/150mm dia, cutting of CI/DI pipe line upto 200mm dia at two portion with the help of electrical driven pipe cutter and levelling the cutting face of pipe with the electric driven grinder and then CI/DI welding by electric welding machine, fixing detacheble joint, tail piece etc then concreteting by PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation filling and mass condrete, after repair of same pipe line, returning filling of excavated materials including removal of surplus soil complete all as specified.
S&F MPCB, TP 40 Amps with suitable wiring for starter control panel including taking out unserviceable worn out MPCB complete all as specified and directed. MAKE : Larsen & Toubro, Schneider , ABB
S&F Power contactors 3 pole, AC 3 phase 32 Amps,with aux contacts 2 NO+2NC complete including taking down existing oneall as specified and directed. MAKE : SCHNEIDER/ABB/ L&T
S&F DOL starter suitable for upto 3 HP, single phase 240V, 10-40 Amps pumping set including replacing the unserviceable wiring kit complete including taking down existing one all as specified and directed. Make : L&T, C&S, BCH
Taking down defective centrifugal pump set 15 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. (Supply of spare parts shall be measured and paid for separately under respective items here-in-after). Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 15 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling bolt with nuts suitable for 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 15 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 15HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 15HP motor pump as per manufacturer's design complete all as specified and as directed.
S&F 63 mm outer dia of pipe of 3 Layer PP-R Polyproplyne random copolymer concealed SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded havIng thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropyelene random fittings fixing complete to walls, floors, ceilings, under trenches including taking down of existing GI/CI unserviceable pipes complete all as specified and directed. Make : SFMC, Supreme, KPT.
S&F 63 mm outer dia PP-R Gate Valves (Brass insert) with iron wheel head screwed both ends for iron pipes and including taking out unserviceable Gate valves complete all as specified and directed.
Supply only 63 mm outer diameter of pipes in cutting road portion 3 Layer PP-R Polyproplyne random copolymer concealed SDR 7.4 (PN 16 @ 20°C) UV stabilized and antimicrobial fusion welded havIng thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropyelene random fittings complete Note : The unit rate is included for supply only and cutting existing road, excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 as in road will be measured and paid separately
Construction of Valve Chamber of size 600mmx 600mmx 600mm (internal) internal size suitable for Sluice Valve, with 150 mm thick PCC 1:4:8, Type D2, using 40mm graded aggregate for foundation, 200 mm thick Brickwork with old size Fly Ash Bricks in Cement Mortar 1:6, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as specified.
S&F Sluice valve with cast iron body and gun metal/steel spindle and hand operated iron wheel, both ends flanged and drilled including nuts, bolts, washers and gaskets, class PN 1.6, for 80mm dia bore pipe, including disconnecting, taking out old and removal, complete all as specified and directed.
S&F Butterfly valves of 80mm bore including joints with rubber gasket and jointing materials bolts, nuts, washers, including taking out existing unserviceable butterfly valve complete all as specified and directed
Opening of existing sluice valve of 80mm bore by dismantling from existing water line and opening of gland cover taking out with spindle with check nut of stainless steel & refixing the same after servicing, greasing including replacement of rubber packing, nuts & bolts, glands etc and to refixing on the same line complete all as specified and directed Note: Any new parts like stainless steel Spindle with check nuts,Gland plate of required size shall be measured and paid separately under respective items
Supply only 80 mm bore stainless steel spindle with check nut, gland plate complete all as specified and directed.
Rectification of existing defective flanged joints with rubber or fibre gasket complete with necessary nuts, bolts and washers for 80 mm dia GI/DI/MS pipes complete all as directed. Note:- a) quoted rates are inclusive of cutting of GI/DI/MS Pipes, jointing materials and preparation of new flanged sockets and refixing the same at existing place. (b) Necessary excavation shall be measured and paid separately under respective items of BOQ
Supply, install, testing and commissioning of outdoor type Factory fabricated motor starter panel suitable for 3 phase 415V, 50Hz system made out of CRCA sheet with suitable neoprene rubber gasket to make it completely, dust and vermin proof, front openable type alongwith locking arrangement having angle iron base frame and legs of suitable size, PCC (1:3:6) bedding for grouting of base including dismantling and taking out old unserviceable panel, complete all as specified and directed. The panel shall comprise the following accessories and specifications :- (a) MCCB 4 pole, 20 Amps, 16 KA - 01 No (Incoming) (b) 3 phase, 415 volt DOL starter suitable for 5 HP motor pump set- 01 Set (c) Motor protection relay - 01 Set (d) Single phase preventor - 01 Set (e) Phase indicating LED lamps RYB - 01 Set (f) Panel mounted multifunction meter including CTs of suitable ratio - 01 Set (g) ON/ OFF push button alongwith indication light - 01 Set (h) Electrolytic high conductivity insulated copper bus bar of suitable capacity - 01 Set (j) Complete control wiring of the panel (k) Earthing terminals - 02 Nos
Cleaning/ overhauling of squirrel cage induction motor by dismantling stator and rotor assembly, carryout necessary tesing of windings to findout any core loss in windings, test of insulation resistance, etc. Applying of proper insulation material for strengthening of insulation, cleaning the casing and slots with wire brush, washing out dust and carbon particles with proper chemical solution, replacement unserviceable bearing, bush, carryour re-alignment of crank shaft re-assembling stator and rotor assemblies, testing complete all as specified and directed for capacity 15 HP to 20 HP. Note:- (a) Rewinding of stator and rotor if required will be measured and paid seperately. (b) Cost of Transportation to and from the local workshop is deemed to be incl in the unit quoted rate.
Rewinding of stator core with proper gauge and amount of highly insulated copper wire as existing, testing complete.
Rewinding of rotor core with proper gauge and amount of highly insulated copper wire as existing, testing complete.
Servicing/ periodical maintenance of automatic fire alarm and smoke detectors system comprising of conventional fire alarm control panel Smoke detection control panel (to accommodate and sensing signals from wireless smoke detectors), Smoke detector (Photoelectric detection Technology), External wireless siren strobe, wireless repeater to extend the communication range of detectors, IR3 Infra Red flame detector, conventional manual call point with EN 54-11 : 2001 and LPCB, conventional sounder etc by attending fault testing of system, quarterly checking of system including preventive maintenance by replacing small spare parts complete all as specified and directed. Location : DWR, ATC Exchange, SRE, CCR, 33 Sqn DSS - 5 Nos.
Note for item No 219 :- (a) The contractor shall make AMC contract with the authorised service agency of any make for fire fighting equipments and the repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The rate quoted shall be deemed to include for carried out all repairs noticed during the period. (c) The authorised service agency must attend as and when called for urgent nature of repair of the fire fighting system. (d) Checking of Alarm signal should not lost when primery power failure untill the alarm signal processed. (e) Checking of audio amplifiers and tone genrating equipment. (f) Checking of smoke detector sensibility (g) Checking of all speaker circuit and loops. (h) Periodicity of servicing shall be around 03 months or as per manufacturers recommendation.
Supply and install in replacement Smoke detector – cover range-50-100 cubic meters(1770-3530 cubic ft) Fully supervised smoke Detector Photoelectric Detection Technology for superior Detection sensitivity, sound and Transmitted Alerts For Smoke, Tamper and Low Battery, works on Power code Protocol, Easy Programming and Enrolling to the control panel, Long Life 9 Volt Alkaline or Lithium Battery- type-3V Cr 123A, operating temperature- -10 ͦC to 50 ͦ C (14 ͦ Fto 122 ͦ F), Simple ceiling , Mount installation with Separate Installation bracket . Model/make:- Ceasefire / Visionic / Apollo / Siemens / Honeywell (Morley). Location : Location : DWR, ATC Exchange, SRE, CCR, 33 Sqn DSS - 5 Nos.
Supply and fixing in replacement of unserviceable battery suitable for smoke detector 9 Volt Alkaline or Lithium Battery complete all as specified and directed.
Supply and install in replacement of Conventional Photoelectric Smoke Detector. Features including removable, High performance chamber, Automatic Sensitivity Window Verification (ASWV)- Drift compensation technology, remote indicator output, wide voltage range (9.5-30 V dc), low profile design with one piece outer cover, single fire LED-360° viewing ,approved by LPCB. Make:- Ceasefire / Visionic / Apollo / Siemens / Honeywell (Morley). Location : Location : DWR, ATC Exchange, SRE, CCR, 33 Sqn DSS - 5 Nos.
Supply and fixing in replacement of unserviceable battery suitable for alarm control panel 3.6 Volt Alkaline or Lithium Battery complete all as specified and directed.
Supply and install in replacement of convetional manual call point features approved to with EN 54-11:2001, terminals can accomodate upto 2.5mm solid conductor, approved by LPCB complete all as specified and directed. Make. Ceasefire / Visionic / Apollo / Siemens / Honeywell (Morley). Location : Location : DWR, ATC Exchange, SRE, CCR, 33 Sqn DSS - 5 Nos.
Supply and install in replacement wireless repeater to extend the communication range of detectors by relaying data between receiver and remote wireless transmitters up to 16 auxiliay repeaters can be positioned between the farthest group of receiver transmitter and receiver transmitter, receive type-super-regenrative, modulation tyep-100% ASK, Power Input Ranges- 13 - 20 VDC, or 11 - 16 VAC, 100 mA min.,.Backup Battery- 9 V-style rechargeable Ni-Cd or Ni-MH. Battery Backup Duration (with fully charged 120 mA/h battery and 1:1 standby/transmit ratio): 2 hours (315 and 433.92 MHz units),LED indicator-Lights during transmission,Compliance with Standards-Meets FCC Part 15, MPT 1340 and directive 1999/5/EC, including adapter-AC/DC 12VAC, 1Amp, battery-9 V rechargeable Ni-Cd or Ni-MH ; 300mAh, 5 hours (315 and 433.92 MHz units). Model/make:-Ceasefire / Visionic / Apollo / Siemens / Honeywell (Morley). Location : Location : DWR, ATC Exchange, SRE, CCR, 33 Sqn DSS - 5 Nos.
Rectification of leakage of GI pipe diameter 40 to 50mm in trench after carry out excavation upto volume of 2 cum, replacement of unserviceable pipe fittings like collar, bend, Tee, Reducer, etc, including threading of existing pipe, applying all necessary engineer effort to check the water leakage, carryout necessary earth works to closs the trench and remove surplus soil upto 50 mtr distance all as directed
S&F Gun Metal gate or globe valve with iron wheel head screwed both ends for iron pipes and of 20mm dia bore including fixing accessories and taking down unserviceable Gun Metal gate valve from existing places complete all as specified and directed.
S&F Rotational moulded polythene water storage tank of 2000 Ltrs capacity (three layer white colour) cylinderical vertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I including taking down of old unserviceable tank complete all as specified and directed.
S&F 50 mm outer dia PP-R Gate Valves (Brass insert) with iron wheel head screwed both ends for iron pipes and including taking out unserviceable Gate valves complete all as specified and directed.
Rising/down pipe of 150mm DI pipe, K-9 with flanges for fixing as rising/ down/wash out pipes for over head water reservoir upto 18mtr elevation including arragement of scafolding and other lifting equipments, repairs to damaged surfaces to match with existing specifications and removal of old corroded pipes complete all as specified and directed.
Supply only superior quality Sodium hypo chlorite solution with chlorine concentration value 4-6% contained in plastic can of 50 Ltrs .
Making arrangement to flush out the existing pipe line of any type upto 50mm bore and upto 100m length, applying 4.5 N/sqmm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Making arrangement to flush out the existing pipe line of any type 63 to 100 mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Note for item 234 to 235 :- (i) The Contractor is deemed to arrange necessary tools and equipments, removing or alteration of fittings from existing pipe lines, arragement of plugging devices, etc to build up specified pressure required to wash out the pipes. This will be inclusive in quoted rate. (ii) Excavation and earth work required will be measured and paid seperately. (iii) The flushing out will be carried out with fresh filled water of well only duly chlorinated with specified sodium hypochlorite solution to disinfect the pipe lines from all pathogens and Coliform organisms.This will be inclusive in quoted rate.
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation all as specified and directed. Make : Model HTSP 317 of safeTrode or equivalent in ISG Global/ ERICO.
The unit quoted rate shall deem to be included for the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less than 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(vi) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(vii) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(viii) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(ix) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained.
(x) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xi) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(xii) The electrode shall carry manufacturer's name .
(xiii) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xiv) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end (copper strip will be measured and paid separately).
(xv) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvi) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(xvii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
(xviii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
M&L Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model EGTEK3LC of ISG Global or equivalent in ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
S&F Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
M&L Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :-The rate is deemed to be included for in case sufficient sand not obtained from excavation, the required additional qty obtain from out side MD land as directed by the Engineer-in-Charge.
M&L Fly ash bricks in cable protection cover including taking down existing bricks of any size complete all as specified and directed.
S&F XLPE insulated,screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 150 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : KEI/ Polycab/ Havells
Supply only 80 mm bore of pipe high density polyethylene pipes (HDPE) of pressure rating 6 kgf/ cm2 laid in trenches for cable protection passing under road/ floor or for fixing to poles complete all as specified and directed. Note : The unit rate is included for supply only.cutting existing road , excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in road will be measured and paid separately.
Supply, installation, commissioning and testing of Factory assembled, Floor mounted, free standing, type tested LT Feeder Pillar Panels, with canopy, as per electrical specifications for outdoor installation, to be made of IP65 Polycarbonate modular enclosures. The Enclosures made of Polycarbonate, should be weather/ vermin proof, anti-acid, anti-corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The manufacturer of boards/panel shall submit a copy of type test reports as per above-mentioned norms either from UL/ERDA/CPRI/NABL labs in India. The panels should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosures should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with 01 No polycarbonate IP 65, 9W LED translucent bulk head luminaire, 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with 01 No of 16A 3P IP 65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 phase and neutral 250 amps current carrying capacity copper bus bar insulated with colour coded heat shinkable sleeves with SMC/DMC insulators, complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above ground level, including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :-
S&F XLPE insulated,screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 120 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : KEI/ Polycab/ Havells
Supply only GI pipe 80 mm bore medium grade for cable protection complete all as specified and as directed by Engr-in-Charge. Make : Tata, Jindal, Surya Prakash Note : The unit rate is included for supply only.cutting existing road , excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 as in road will be measured and paid separately.
S&F XLPE insulated,screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 95 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : KEI/ Polycab/ Havells
Supply only 50 mm bore of pipe high density polyethylene pipes (HDPE) of pressure rating 6 kgf/Sq cm complete all as specified and directed.
S&F in repairs Cable jointing kit for 1.1 KV grade cable for outdoor stright through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 95 sqmm to 150 sqmm complete all as specified and directed. Make : Reychems, Densons, M Seal
Supply, installation, commissioning and testing of Factory assembled, Floor mounted, free standing, type tested LT Feeder Pillar Panels, with canopy, as per electrical specifications for outdoor installation, to be made of IP65 Polycarbonate modular enclosures. The Enclosures made of Polycarbonate, should be weather/ vermin proof, anti-acid, anti-corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The manufacturer of boards/panel shall submit a copy of type test reports as per above-mentioned norms either from UL/ERDA/CPRI/NABL labs in India. The panels should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosures should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with 01 No polycarbonate IP 65, 9W LED translucent bulk head luminaire, 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with 01 No of 16A 3P IP 65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 phase and neutral 600 amps current carrying capacity copper bus bar insulated with colour coded heat shinkable sleeves with SMC/DMC insulators, complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above ground level, including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :-
Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x6mm (upto 7.5m length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
Note for item No 271 :- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab.
(d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
S&F Galvanised earth strip of size 25 x 6mm fixed on proper post insulator at the instrument end complete all as specified and directed.
J and K constructions company
VARGHESECHACKO AND CO
KUMAR AGENCIES
SARAVANARAJA CONSTRUCTIONS
K T ASSOCIATES
KSR AND COMPANY
devan enterprises
A.GOVINDARAJ
Lucky Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .