| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹22.9 L+₹75,285 (3.39%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹26.1 L+₹3.9 L (17.8%)Rejected-Finance MAIN BAZAR SURANKOTE DISTT POONCH 185121 J K | SURANKOTE | POONCH | J K | 185121 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹28.7 L+₹6.6 L (29.6%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹30.4 L+₹8.3 L (37.3%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
27 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 881 EWS
GE 881 EWS C/o 56 APO
PROVN OF SEPTIC TANK AND SOAKAGE WELL NEAR BLDG NO P-48 AT BATTALION REAR LOCATION AT MENDHAR AND SPL REPAIRS TO BLDG NO P-11 AT BALNOI BASE UNDER THE AOR OF GE 881 EWS
2021_MES_474268_2
GE/PNH-28/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹54,000
Yes
11 Feb 2022
11 Dec 2021
29 Dec 2021
11 Dec 2021
27 Dec 2021
13 Dec 2021
60 days
Amount
Construction of 30 users LLDPE septic tank designed to carry sewage and sludge, excavation in any type of soil, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) below foundation, vent shaft, connections etc. conventional type all as shown on Drawing No: CE/TD-1202/2003 sheet 1/2 and 2/2 amended upo date complete all as specified and directed by Engineer-in-charge.
Construction of soakage well 3.0 mtr dia and 4.50 mtr deep below inlet (depth) from inlet pipe to ground level 45 cm, including excavation and earth work in any type of soil, PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) in foundation, wall in honey combed brick work in CM 1:4, cover slab of M-25 (Design mix), filling with brick bats, earth cushion on brick lining on top and inlet pipe 150mm dia all as shown on drawing No: CE/TD-1202/2003 sheet 1/2 and 2/2 amended upto date complete all as specified and directed by Engineer-in-charge.
Excavation over area not exceeding 1.5m deep and and getting out in hard dense soil, complete all as specified and directed.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation etc for shafts, wells,cesspits, man holes, pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5m depth and getting out in hard/dense soil, complete all as specified and directed.
M&L for Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations filling and mass concrete, complete all as specified and directed.
M&L for Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius, built in cement mortar (1:6), complete all as specified and directed.
M&L for Plain cement concrete 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in surface channels and drains, complete all as specified and directed.
M&L for Rendering 15 mm thick in CM 1:4 on fair faces of brick wall surface or concrete surface finished even and smooth without using extra cement including mixing of water proofing compound @3% by weight of cement (WPC shall be measured and paid separately) including all necessary scaffolding, complete all as specified and directed.
M&L for Precast cement concrete (1:2:4) using 20mm graded crushed stone aggregate as in landings, cover slab (for manholes etc), chullah hoods, chajjas, water troughs, shelves and similar articles with plain fair faces including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) including necessary form work complete all as specified and directed by Engineer-in-Charge.
S&F TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified and directed.
150 mm internal dia, Salt glazed & stoneware drain pipe grade ‘A’, laid in trenches and jointed with cement joints, complete all as directed by Engineer -in- charge.
M&L for Concrete bed to drain pipes of 150 mm dia incl packing under and haunching against the sides of pipes with concrete, after they are laid in cement concrete 1:3:6 typer C2 (using 40mm graded crushed stone aggregate) and testing including necessary form work, complete all as specified and directed.
Returning, Filling in soil including spreading, leveling, watering and well ramming in players not exc 25cm, complete all as specified and directed.
Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5mtr above starting point, complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specified provided for complete all as specified and directed.
M&L for 150mm thick PCC 1:2:4, type B-1, using 20mm graded stone aggregate as in floor/hard standing/path and finished surfaces of concrete topping even and fair without using extra cement, complete all as specified and directed.
S&F Aluminium dividing strips, 1.5mm thick and 22mm wide, inserted in position, conform to design complete all as specified and directed.
M&L for PCC 1:2:4 type B-2 in 40 mm graded aggregate in foundation filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in surface channel and drains complete all as specified and directed by Engineer-in-Charge.
Taking up or down 20 mm dia steel tubing and connections complete all as specified and directed.
M&L for refixing 20mm dia old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed.
S&F G.I water tubing 20mm bore medium grade ISI marked with all fittings fixed to walls, cellings or laid in floor complete all as specified and directed.
Taking up or down 15 mm dia steel tubing and connections complete all as specified and directed.
M&L for refixing 15mm dia old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed.
S&F G.I water tubing 15mm bore medium grade ISI marked with all fittings fixed to walls, cellings or laid in floor complete all as specified and directed.
Taking up or down 25 or 32 mm dia steel tubing and connections complete all as specified and directed.
S&F G.I water tubing 32mm bore medium grade ISI marked with all fittings fixed to walls, cellings or laid in floor complete all as specified and directed.
S&F in repairs gun-metal, globe or gate valves of 20mm dia with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S&F in repairs gun-metal, globe or gate valves of 15mm dia with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
Dismantling water tanks exc 500 ltr but n.exc. 1000 ltr capacity and removing to store or cosidered in schedule of credit complete all as specified and directed.
S&F 1000 ltr capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
S&F in repairs high pressure PTMT ball valves with high density polythene float & fly nut,epoxy coated Aluminium rod complete screwed with necessary fittings for iron pipe of size 25mm dia/bore (min. wt 40mm- 690 gms) complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc as in patches complete all as specified and directed.
M&L for 20mm thick rendering in cement mortar 1:4 on fair faces of stone masonry surface or surface other than fair face of brick-work or one side of lathing, surface finished even & fair complete all as specified and directed.
M&L for 10mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surface, surface finished even & fair complete all specified and as directed.
M&L for 5mm thick rendering on ceiling in cement mortar 1:3 on fair faces of brick work or concrete surface, surface finished even & fair complete all specified and as directed.
M&L for preparation of new plastered wall surface and applying two coats of cement base paint over a coat of white wash complete all as specified and directed.
M&L for preparation of new plaster surface and applying two coats of white wash on ceiling complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for Non-skid ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM 1:4 complete all as specified and directed.
M&L for roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry,built in cement mortar complete all as specified and directed.
M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted built in cement mortar in CM 1:6 complete all as specified and directed.
M&L for walling of random rubble masonry, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete (except stone) complete all as specified and directed.
Extra over stone walling for hammer dressing to face stones & dressing of face beds and joints, with max.depression on face from straight edge held against the dressed surface n exc.20mm in lime or sand stone, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed.
S&F 0.56mm thick plain aluminium sheeting Alloy 31000 H4 in stepped flashing for crimple joint (measured as the minimum rectangle from which the pieces can be cut) complete all as specified and directed by Engr-in-Charge.
M&L for complete removal of existing treatment on old wall surface and applying one coats of cement base paint complete all as specified and directed.
M&L for preparation of old decorated ceiling surfaces and applying one coat of white wash complete all as specified and directed.
M&L for preparation of old decorated wall surfaces and applying one coat of white wash complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for roughening surface of old concrete floor by picking, sweeping clean by using steel wire brush and washing down with water, fanning dust etc and taking down tarfelt/cement plaster and removing demolished materialn.exc. 50m, completeall as specified and directed by Engr-in-Charge.
M&L for 25mm thick PCC 1:2:4, type B-1, using 20mm graded stone aggregate as in roof padding, complete all as specified and directed.
M&L for 10mm thick cement plaster in cement mortar 1:4 in concrete, brick surfaces including finishing even and smooth with out using extra cement to receive roof treatment, mixed with water proofing compound @ 3% by weight of cement over complete all as specified and directed. Note :- WPC shall be measured and paid separately.
M&L for water proofing roof treatment with priming sufaces and applying heavy treatment (for severe conditions) (except felt) with APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
Taking down carefully unsv aluminium / copper conductor point wiring (light, fan, light socket, power socket) complete fitting such as swithes, sockets, lamp holder, utility light fitting, fan regulator etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and as directed.
M&L for Point wiring with 1.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated and unsheathed heavy duty cable in colour code including contineous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLS insulated and unsheathed heavy duty cable drawn in and including concealed PVC rigid conduit medium grade ISI marked terminated into CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc for one light/fan/Exhaust fan point controlled by one switch/ 2way bell push or one fan point controlled by one switch through regulator, complete all as specified and directed.
All as per item No 58 above but for one fan/exhaust fan point controlled by one way switch on independent board with PVC insulated copper conductor cable 1.5sqmm complete all as specified and directed.
All as per item No 58 above but for 3 Pin socket outlet 5 Amps point on same board complete all as specified and directed.
All as per item No 58 above but for 3 Pin socket outlet 5 Amps point on independent board with PVC insulated copper conductor cable 1.5sqmm complete all as specified and directed.
All as per Item No 58 above but for 6 Pin socket outlet 15 Amps point on independent board other switches with with PVC insulated copper conductor cable 2.5sqmm 1100 Volts grade, complete all as specified and directed.
S&F in repair Switch socket multipurpose combination 2 in 1, 2 and 3 pin, 5 Amp flush type universal, complete all as specified and directed.
S&F in repair Switch socket multipurpose combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal, complete all as specified and directed.
S&F in repair Switch piano flush type 16 Amp single pole one way, (ISI marked), complete all as specified and directed.
S&F in repair Switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed.
S&F in repair Ceiling rose (ISI Marked) 3 Phase PVC/poly carbonate, insulated body, complete all as specified and directed.
S&F in replacement LED Tube light fitting suitable for LED 20W tube rod made out of with polycarbonate housing & integrated electronic driver complete with hosing with all accessories pre wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting including 20W LED tube rod fixed in repairs, complete all as specified and directed. Make:-Havells Cat Part No:-LHLDEFXD5L8R020 for LED tube rod & Cat Part No:-LUMILINEPLUSBS20WLED865SPCSS or Equaivalent cat part of make as specified in P.S. Note :- The LED batten and LED tube rod shall be of same make.
S&F in repair Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings with & including LED lamp 10 watts (B-22 holder), complete all as specified. Make of LED lamp:- Havells cat part No LHlDERUEML8x010 or Equaivalent cat part of make as specified in P.S.
Taking down ceiling fan, sealing cable end, dismantling blades and removing fan and blades & depositing to store, complete all as specified and directed.
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan after repair if any as obtained / taken out from item No 70 above, complete all as specified and directed.
S&F in repair MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series complete all as specified and directed. Make: Havells Cat Part No. DHMGCSPF006-032 or equivalent in Legrand/ C&S Electric/ ABB/ Siemens/ Scheneider
S&F in repair House service bracket (hook type), complete, with 3m long GI pipe 40mm dia medium grade, two Nos 90 degree bend, MS hook and guy or stay including taking down existing old unsv house bracket, complete all as specified and directed.
S&F in repair Earthing complete with galvanised mild steel earth plate electrode of size 600x600x6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised ironl including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube flor watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and directed.
S&F in repair Fan regulator stepped type (electronic ) flush type for 1200/1400mm sweep AC ceiling fan, complete all as specified and directed.
S&F in repair Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 12 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioningcomplete all as specified and directed. Make:-Havells cat part No-DHDPSHODPW12 or Equivalent cat part of make as specified in P.S.
S&F MCB single pole and neutral 40 to 63 amps 240 volts 10 KA 'C' series complete all as specified and directed. Make: Havells Cat Part No. DHMGCSNF040 - DHMGCSNF063 or equivalent in Legrand/ C&S Electric/ ABB/ Siemens/ Scheneider/
S&F 1100 volts grade heavy duty cable PVC insulated multi stranded aluminium conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia GI suspension wire, one twin core cable flat of circular of size 10 Sqmm including taking down existing old unsv service connection, complete all as specified and directed.
M/S KULBIR SINGH SODHI AND CO
M/S KIRAN CONSTRUCTIONS
M/S ZARGARCONSTRUCTION CO
Modh Hafiz Khan
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .