GE(AF) EM Chakeri
GE(AF) EM Chakeri Kanpur
SPECIAL REPAIR / REPLACEMENT OF BER DG SET OF 4 BRD, INSTALLATION OF CENTRALLIED FIRE ALARM SUPPRESSION SYSTEM AT REB(C), PROVN OF DEFICIENT AC TOWER, PROBN OF SOLAR STREET LIGHTS IN CERTAIN LOCATION AT AFS KANPUR.
2025_MES_745559_1
8788/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Area under GE(AF) EM Chakeri
As per tender document
9 documents required · 9 mandatory
₹500
GE(AF) EM Chakeri
₹85,500
Yes
15 Jan 2026
20 Dec 2025
27 Jan 2026
22 Dec 2025
22 Jan 2026
5 Jan 2026
Supply, install , testing, commissioning of 'Silent type' diesel generating set alongwith having prime power rating of 415 Volts at 1500 RPM , 0.8, 125 KVA lagging power factor at 415 volts suitable for 50 hz 3 phase system and for 0.85 load factor , CPCB-IV plus complied, acoustic enclosure, engine is designed to meet stringent exhaust emission tests as per revised MoEF norms, anti vibration mountings, control panel and foundation. The DG set should be robust in construction factory tested and assembled to ensure perfect alignement of engine and Alternator on a common base frame. The DG set shall be designed and suitable to operate as per tropical condition of Chakeri, kanpur and for more details on service condition refer particular specification.
The DG set shall be Eco-friendly product complying with CPCB noise and emission norms (Noise and Emission values lower than CPCB limits) and complying with latest emmission standards issued vide gazatte notification G.S.R. 804(E) by MoEF The DG set shall be comprising of following item as under :--
(a) Diesel Engine : The diesel engine shall be of four stroke cycle multi-cylinder, direct injection radiator water cooled, turbo charged with after cooler, compression ratio (16.7:1), Air to air after cooling and optimised turbo charger for increased altitude capabilities developing required 155 BHP @ 1500 rpm ( MoEF Certified Power) under NTP condition of BS 5514/ISO 3046 with an over load capacity of 110% for one hour in any specified 12 hrs of continuous operation, suitable for generating set application on AMF mode. The engine shall confirm to IS: 10000/BS:649/BS 5514/ISO 3046. The engine shall have the following accessories::-
(i) Cooling fan and radiator. (ii) DM water cooling systems with pre-mix anti-corrosive additive(iii) Turbocharger (iv) Fly wheel with fly wheel housing (v) Electrical engine starter motor (disengagement after start-up) with batteries. (vi) Battery charging systems. (vii)Industrial/ Residential silencer and exhaust pipes having suitable height with supporting structure. (viii) Stainless steel exhust flexible elbow. (ix) Thermal sealing of exhaust pipe and aluminium cladding for complete exhaust pipe and silencer. (x) Required filters for fuel, lube oil, air etc. (xi) Sets of flexible hoses as required. (xii) Suitable rubber coupling to Alternator with guard. (xiii) Suitable Engine controller for protection of the engine. (xiv) Coolant heater. (xv) Oil drain Pump. (xvi) Heavy duty air cleaner. (xvii) Venturi combo Spin On Oil Filter (xix) Electrical starter motor with soft start engagement feature (xx) Plate type lube oil cooler with first fill of lube oil and coolant.
(b) Engine protections: (i) High coolant temperature warning & trip(ii) Low lubricating oil pressure warning & trip (iii) Low coolant level warning & trip (iv) Fail to crank trip (v) Over crank trip (vi) High and low speed trip (vii) Low or Hgh battery voltage alarms. (viii) Clogged filter warning (ix) Lack of fuel (x) High Canopy Temperature (xi) Set fail to start protection after failure of the set to start after successful three consecutive start attempts. (c) Starting system : The engine starting shall be by means of totally enclosed axial type electric starter suitable for 12 volts DC starting system comprising of starter motor, voltage regulator and arrangement for initial exciation complete 12 volt batteries or with suitable number of batteries (25 plates, 180 AH Sealed Maintenance Free (SMF) Lead-Acid type)as required as per specifications.
(d) Engine mounted instrument panel fitted with and having digital display for the following :- (i) Start stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure inidication (iv) Lubrication oil temperature indication (v) Battery charging indication and RPM indication (vi) Over speed indication and engine hours indication (vii) Low lube oil indcation. (e) Alternator : Brushless Type, Screen protected, Revolving field, Self excited Permanent Magnet Generator (PMG) Alternator conforming to IS/IEC 60034-1 rated at 125 kVA 3 phase 0.8 PF 415V , 4 wire 1500 rpm , class H insulation, self regulated through AVR confirming to IS :4722/BS 2613 suitable for tropical condition with brush less exciter, dynamically balanced rotor, alternator efficiency not less than 94.6% , housed in screen protected drip proof enclosure.
The alternator shall beconfirming to IS 13364 Part-2 & IS 15999 part-1/IEC 60034 Part-1 capable of delivering rated output at rated power factor with the following :- (i) Terminal voltage differing from the rated value by not more than +/- 5%. (ii) Frequency differing from the rated value by not more than +/-0.5%. (iii) Short circuit capacity of 300% for 10 seconds. (iv) Over load capacity of 110% for one hour. The insulation class of the Alternator shall be class H. The temperature rise shall be limited to class B and Ingresses enclosure protection shall IP23 or better. The alternator shall be fitted with suitable Nos. Resistance Temperature Device (RTD) & Bearing Temperature Device (BTD) along with space heaters. (f) Alternator Protection : Alternator should have following protections :- (i) Over and under voltage (ii) Under and over frequency warning and trip (iii) Loss of excitation (iv) Over current and Earth Fault and short circuit Protection. (v) Unbalanced loads (vi) Restricted Earth Fault Protection.
(vii) Differential protection . (viii) Diode Failure. (g) Voltage regulator : A rapid response voltage regulator shall be provided to regulate the generated voltage. the overall regulations from no load to full load,including cold to hot variation and load power factor of 0.8 lag to unity shallbe within 2% be of the normal recovery following sudden application and disconnection of load. (h) Acoustic enclosure : The acoustic enclosure should be supplied along with DG set from the manufacturer outlet itself as per CPCB norm. Acoustic enclosure shall be of powder coated and fabricated out of 2mm thick CRCA MS sheet. The canopy shall have four hinged doors, one door with glass window to view proper parameters on the control panel. The canopy and doors shall have inside lining of fire retardant foam/glasswool as acoustic materials. the base frame shall be fabricated in ISMC channel or in sheet metal, with lifting hooks for convenient lifting of complete set i.e. along with canopy, engine and alternator.
The sound level shall have less than 75 db (A) at a distance of 1 meter. High quality noise absorbant and fire-retardant grade acoustic insulation material (P.U Foam) complying to IS 8183. The allowable temperature raise inside the canopy is 5 to 7 deg Centigrade. The measurement of noise should be as per ISO 3744/ISO 8528 (Part 10) standard. The Canopy has the provision of emergency push button, external to the canopy. (j) Governor : The governor shall be of electronic type Integral with FIP & Isochronous cpability , suitable for monitoring constant engine speed within the specified limits for auto parallel and auto load sharing operation. (k) Exhaust : The exhaust piping system shall be supplied with a hospital grade silencer and catalytic converter suitably optimized to meet stringent noise emission standards laid down by MoEF / CPCB . The exhaust piping and the silencer shall be wrapped with aluminium cladding.
The exhaust line shall be extended beyond the height of the utility building roof as required by pollution control norms. Suitable supporting structure for installation shall be provided. The piping shall be confirming to IS:3589 cut to required length and installed with necessary bends, supports and clamps. (l) Hot air exhaust (Radiator cooling):- GI duct shall be providedfor hot air exhaust from DG set up designated place of duct outlet. The duct shall be made of 14 Gauge thick Class-8, Galvanized Iron (GI) Sheet. Galvanised Iron (GI) duct shall be provided for venting hot exhaust air out of the DG room, from radiator hot air outlet point of the DG Acoustic enclosure through nearest brick wall. (m) Fuel Tank : Inbuilt/Internal bottom mounted (with-in DG set or with-in base frame) diesel tank of suitable capacity with mounting brackets, complete with fuel inlet, out let, air vent drain plug, level indicator, inter connection pipes from tank to diesel generator as required. Suitable barrier shall be provided between Diesel tank and the Engine. Fuel tank shall be fabricated from 3.0mm thick MS sheet complete with all accessories and fuel piping between fuel tank and diesel engine with MS class C pipe of suitable dia complete all as specified and as per tropical condition of Chakeri, Kanpur. Standard Fuel tank Capacity and designed capacity shall be suitable for 8 hrs continous operation.
(n) Control Panel :- Control panel shall be manufactured with 14/16 gauge CRCA sheet duly powder coated. The control panel consists of the following parts: (a) Integrated advanced digital Controller control system microprocessor-based suitable for generator set monitoring (b) Metering and control system with LCD display designed to meet the demands of engine driven generator sets (c) Aluminium bus bars with suitable capacity with incoming/outgoing terminals (d) Instrument fuses duly wired and ferruled (e) Air Circuit Breakers (ACBs)/Moulded Case Circuit Breaker (MCCB) of suitable rating with overload and short circuit protections. (o) AMF Panel :- DG set shall consist of AMF panel with enclosure with MCCBs of suitable size along with all connected accessories. (i) AMF panel shall be manufactured and installed ny OEM of DG Set. (ii) AMF panel should be fitted installed and shall be treated with anti corrosive treatment of seven tank process by OEM of DG set only.
(p) Base Frame and Foundation : Both the engine and alternator mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangemnt as per recommendation of manufacturer. Note :- (i) DG set shall be composite type with control panel, Prime mover, alternator and allied accessories in one enclosure (ii) LT Cable of suitable rating from DG set Alternator output to Automatic main failure panel (AMF panel ) should be provided by the contractor. (iii) Cost of DG set foundation deemed to be included in cost of item. (iv) Contractor should submit necessary drawing to GE/Engr-in-Charge before procurement. (v) Control panel shall be manufactured and installed by OEM of DG Set.(vi) The engine of DG set shall be suitable derated to suit the climatic condition of AF Stn Chakeri, kanpur so as to give output including 10% over load.
(vii) Phase-I test will be carried out by Engineer-in-Charge for no load for 1 hour and 100% load for 01 hour each and Phase-II test will be carried out in presence of IEM/rep of Accepting Officer for no load, 25% , 50% , 75% , 100% for 11 hours and 110% for 1 hour over load and DHPP (fuel) required for testing of DG sets is deemed to be included in above quoted rate (viii) The DG set shall be suitable for auto main failure function. (ix) The quoted rate for DG set is inclusive of PCC foundation for DG set. the foundation for DG set should be made of PCC 1:2:4 type B-1 using 20mm graded stone aggregate below the ground level minimum 300 mm and 200 mm above ground level, size of platform shall be as per manufacturers recommendations including mounting with suitable fastner/nut/bolts etc complete all as specified and directed.
Supply,install , testing, commissioning of Trolley mounted 'Silent type' diesel generating set alongwith having prime power rating of 415 Volts at 1500 RPM , 0.8 , 125 KVA agging power factor at 415 volts suitable for 50 hz 3 phase system and for 0.85 load factor , CPCB-IV plus complied, acoustic enclosure, engine is designed to meet stringent exhaust emission tests as per revised MoEF nors, anti vibration mountings, control panel and foundation. The DG set should be robust in construction factory tested and assembled to ensure perfect alignment of Engine and Alternator on a common base frame. The DG set power rating indicated above is inclusive of altitude correction factor however the DG set shall be designed and suitable to operate as per tropical condition of Chakeri, Kanpur and for more details on service condition refer particular specification. the DG set shall be Eco-friendly product complying with CPCB noise and emission norms (noise and emission values lower than CPCB limits) and complying with latest emmission standards issued vide gazatte notification G.S.R 804(E) by MoEF The DG set shall be comprising of following item as under:-
(a) Diesel Engine : The diesel Engine shall be of four stroke cycle multi-cylinder,direct injection radiator water cooled, turbo charged with after cooler, compression ration 16.7:1, Air to air after cooling and optimised turbocharger for increased altitude capabilities developing required 155 BHP @ 1500 rpm (MoEF Certified Power ) under NTP condition of BS 5514/ISO 3046 with an over load capacity of 110% for one hour in any specified 12 hrs of continuous operation, suitable for generating set application on AMF mode. The engine shall confirm to IS:10000/BS:649/BS 5514/ISO 3046. The engine shall have the following accessories:- (i) Cooling fan and radiator. (ii) DM water cooling systems with pre-mix anti-corrosive additive (iii) Turbocharger. (iv) Fly wheel with fly wheel housing. (v) Electrical engine starter motor (disengagement after start-up) with Batteries. (vi) Battery charging systems. (vii) Industrial/Residential silencer and exhaust pipes having suitable height with supporting structure. (viii) Stainless steel exhaust flexible elbow.
(ix) Thermal sealing of exhaust pipe and aluminium cladding for complete exhaust pipe and silencer. (x) Required filters for fuel, lube oil, air etc. (xi) Sets of flexible hoses as required. (xii) Suitable rubber coupling to Alternator with guard. (xiii) Suitable Engine controller for protection of the engine. (xiv) Coolant heater. (xv) Oil drain Pump. (xvi) Heavy duty air cleaner. (xvii) PT fuel system with Electronic Step Timing Control (ESTC) injectors (xviii) Venturi combo Spin On Oil Filter (xix) ELectrical starter motor with soft start engagement feature (xx) Plate type lube oil cooler with first fill of lube oil and coolant. (b) Engine protections:- (i) High coolant temperature warning & trip (ii) Low lubricating oil pressure warning & trip (iii) Low coolant level warning & trip (iv) Fail to crank trip (v) Over crank trip (vi) High and Low speed trip (vii) Low or High battery voltage alarms. (viii) Clogged filter warning (ix) Lack of fuel (x) High Canopy Temperature (xi) Set fail to start protection after failure of the set to start after successful three consecutive start attempts.
(c) Starting system :- The engine starting shall be by means of totally enclosed axial type electric starter suitable for 12 volts DC starting system comprising of starter motor, voltage regulator and arrangement for initial exciation complete 12 volt batteries or with suitable number of batteries (25 plates, 180 AH Sealed Maintenance Free (SMF) Lead-Acid type) as required as per specifications. The battery shall be supplied with a suitable floor mounted MS stand treated with seven tank treatment, two coats of red oxide/primer & acid resistant paint with wooden base, adaptor box etc. with copper conductor battery leads of required length and socket/clamps (d) Engine mounted Instrumentation Panel fitted with and having digital display for the following : (i) Start stop switch with key. (ii) water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication and RPM indication (vi) Over speed indication and Engine hours indication (vii) Low tube oil temp indication.
(e) Alternator -: Brushless Type, Screen protected, Revolving field, Self excited Permanenet Magnet Generator (PMG) Alternator conforming to IS/IEC 60034-1 rated at 125 kVA 3 phase 0.8 PF 415V, 4 wire 1500 rpm , Class H insulation, self regulated through AVR confirming to IS : 4722/BS 2613 suitable for tropical condition with brush less exciter, dynamically balanced rotor, alternator efficiency not less than 94.6%, housed in screen protected drip proof enclosure. The alternator shall be confirming to IS 13364 Part-2 & IS 15999 Part-1/ IEC 60034 Part-1 capable of delievering rated output at rated power factor with the following :- (i) Terminal voltage differing from the rated value by not more than +/- 5%. (ii) Frequency differing from the rated value by not more than +/-0.5%. (iii) Short circuit capacity of 300% for 10 seconds. (iv). Over load capacity of 110% for one hour. The insulation class of the Alternator shall be class H. The temperature rise shall be limited to class B and Ingresses enclosure protection shall IP23 or better. The alternator shall be fitted with suitable Nos. Resistance Temperature Device (RTD) & Bearing Temperature Device(BTD) along with space heaters.
(f) Alternator Protection: Alternator should have following protections:- (i) Over and Under voltage (ii) Under and over frequency warning and trip (iii) Loss of excitation (iv) Over current and Earth Fault and Short Circuit Protection (v) Unbalanced loads (vi) Restricted Earth Fault Protection (vi) Differential protection. (viii) Diode Failure. (g) Voltage regulator :- A rapid response voltage regulator shall be provided to regulate the generated voltage. The overall regulations from no lad to full load, including cold to hot variation and load power factor of 0.8 lag to unity shall be within 2% of the normal voltage. The excitation system shall be designed to promotr rapid voltage recovery following sudden application and disconnection of load. (h) Acoustic enclosure :- The acoustic enclosure should be supplied along with DG set from the manufacturer oulet itself as per CPCB norm -IV. Acoustic enclosure shall be of powder coated and fabricated out of 2mm thick CRCA MS sheet. The canopy shall have four hinged doors, one door with glass window to view proper parameters on the control panel.
The base frame shall be fabricated in ISMC channel or in sheet metal, with lifting hooks for convenient lifting of complete set i.e. along with canopy, engine and alternator. The sound level shall have less than 75 db (A) at a distance of 1 meter. High quality noise absorbant and fire-retardant grade acoustic Insulation material (P.U. Foam) complying to IS 8183. The allowable temperature raie inside the canopy is 5 to 7 deg. Centigrade. The Measurement of noise should be as per ISO 3744/ISO 8528 (Part 10) standard. The canopy has the provision of emergency push button, external to the canopy (j) Governor :- The governor shall be of electronic type Integral with FIP & Isochronous capability, suitable for monitoring constant engine speed within the specified limits for auto parallel and auto load sharing operation.
(k) Exhaust :- The exhaust piping system shall be supplied with a hospital grade silencer and catalytic converter suitably optimized to meet stringent noise emission standards laid down by MoEF /CPCB.The exhaust piping and the silencer shall be wrapped with rock wool and/or calcium silicate. The outside shall be neatly wrapped with aluminium cladding. The exhaust line shall be extended beyond the height of the utility building roof as required by pollution control norms. Suitable supporting structure for installation shall be provided. The piping shall be confirming to IS:3589 cut to required length and installed with necessary bends, supports and clamps. (l) Hot air exhaust (Radiator cooling): GI duct shall be provided for hot air exhaust from DG set up to designated place of duct outlet. The duct shall be made of 14 Gauge thick Class-8, Galavanized Iron (GI) Sheet. Galvanized Iron (GI) duct shall be provided for venting hot exhaust air out of the DG room, from radiator hot air outlet point of the DG Acoustic enclosure through nearest brick wall.
(m) Fuel Tank-: Inbuilt/Internal bottom mounted (with-in DG det or with-in base frame) diesel tank of suitable capacity with mounting brackets, complete with fuel inlet, out let, air vent, drain plug, level indicator , inter connection pipes from tank to diesel generator as required. Suitable barrier shall be provided between Diesel tank and the Engine. Fuel tank shall be fabricated from 3.0 mm thick MS sheet complete with all accessories and fuel piping between fuel tank and diesel engine with MS class C pipe of suitable dia complete all as specified and as per tropical condition of Chakeri, Kanpur. Standard Fuel tank Capacity and designed capacity shall be suitable for 8 hrs continous operation. (n) Control Panel : Control Panel shall be manufactured with 14/16 gauge CRCA sheet duly powder coated. The control panel consists of the following parts: (a) Integrated advanced digital Controller control system microprocessor-based suitable for generator se monitoring (b) Metering and control system with LCD display designed to meet the demands of engine driven generator sets
(c) Aluminium bus bars with suitable capacity with incoming/outgoing terminals (d) Instrument fuses duly wired and ferruled (e) Air circuit breakers (ACBs)/Moulded Case Circuit Breaker (MCCB) of suitable rating with overload and short circuit protections. (o) AMF Panel -: DG set shall consist of AMF panel with enclosures with MCCBs of suitable size along with connected acccessories. (i) AMF panel shall be manufactured and installed by OEM of DG set. (ii) AMF panel should be fitted/installed and shall be treated with anti corrosive treatment of seven tank process by OEM of DG set only. DG Set Trolley :- Desgin, fabrication, supply, transport, positioning, testing and commissioning of heavy duty towable trolley suitable for mounting silent diesel generator sets for 125 KVA, complete with the following integrated features, delivery at premises of Engineer-in-charge and commissioning fully ready for service : -
(i) Main chassis : IS 2062 e350 RHS 125x65x6 mm full perimeter ladder frame with cross members ≤450 mm c/c : deck clear size 4500 mm (L) x 1500 mm (W) in 5mm chequer plate : two longitudinal T slot rails (IS 150x75 channel) @200 mm pitch for adjustable genset bolting: deck deflection under 8 ton load to be ≤ L/360. (ii) Axle & suspension : Tandem solid beam axles, 4000 kg each, EN 8 75mm square; 12 leaf HD spring packs with walking beam equaliser, greasable pins & PU bushes. (iii) Tyre assembly : four tubeless radials 235/75 R17.5 12 PR cn 10 stud 6.75 x 17.5 rims plus one identical spares strapped to deck; tyre rating ≥ 3150 kg @ 7bar. Make : Bridgestone /Michillen /MRF
(iv) Draw bar & towing hook : RHS 150x75x6 mm "A frame" draw bar, 1400mm projection, fitted with Ø 40mm forged lunette eye (SAE J847 type) and interchangeable 50mm ballcoupler; 10 mm grade 80 safety chain 1000 mm effective length. (v) Landing & levelling gear : front swing away screw type jockey wheel jack SWL 1500 kg (lift)350 mm); two rear drop leg stabilisers SWL 2000 kg each (lift 400 mm, locking collar). (vi) Braking / parking : Mechanical hand brake acting on both acles via threaded yoke; two HD rubber wheel chocks (230x200x170 mm) with deck clips.(vii) Cable reel assembly : side mounted manual worm gear drum, assembly to have capacity of 30 m of 4 C 300 mm² AI XLPE flexible power cable; shrouded cam lok terminals; grease lubricated spindle bearings. (viii) Earthing kit : Two 25 mmx 3mm aluminium earth strips, and common bonding bar linking DG neutal, chassis & rods with flexible copper cable. (ix) Tool box & accessories : Lockable HDG sheet steel tool box 600x400x400 mm with common key, housing wheel spanner, 5t bottle jack, two spare wheel nuts sets, first aid kit, 9 kg CO² extinguisher (IS 15683), hazard triangles, and rubber chocks.
(x) Lifting & tie downs : Four 20 mm D chackle lugs inset 200 mm from deck sorners plus central lifting eye SWL 10 ton chassis spine. (xi) Finish : Hot dip galvanising to IS 4759, min 85µm; epoxy polyurethane top coat RAL 7032, total DFT ≥130µm; reflective conspicuity tape AIS 008. (xii) Inspection & tests : 4000 kg static load test, brake hold test on 8% gradient, paint holiday test, continuity ≤0.1 Ω between draw bar & chassis. (xiii) The rate quoted shall be deemed inclusive of all design, steel, welding consuables, fsteners, galvanising, painting, tyres, jacks, tools, cable reel, earthing hardware, spares, packing, transport up to premises, on site placement, commissioning, testing and demonstration complete in all respects. Note : Contractor should submit necessary drawing to Engineer-in-charge for approval of department before procurement and fabrication.
Note:- DG set shall be composite type with control panel, Prime mover, alternator and allied accessories in oneenclosure (ii) LT Cable of suitable rating from DG set Alternator output to Automatic main failure panel (AMF panel) should be provided by the contractor. (iii) Control panel shall be manufactured and installed by OEM of DG set. (iv) The engine of DG set shall be suitable derated to suit the climatic condition of AF Stn Chakeri, Kanpur so as to give desired output including 10 % over load.(v) Phase-I test will becarried out by Engineer-in-Charge for no load for 1 hour and 100% load for 01 hour each and Pahse-II test will be carried out in presence of IEM / rep of Accepting Officer for no load, 25%, 50% , 75% , 100% for 1 hour over load and DHPP (fuel) required for testing of DG sets is deemed to be included in above quoted rate (vi) The DG set shall be suitable for auto main failure function.
M&L for repair / overhauling of complete diesel engine by opening top head, cleaning of Engine of Generator and replace worned out parts of engine, checking and setting right the alignment of Engine & alternator, servicing of engine for smooth running, observing & setting correctly the unusal sound & colour of smoke from exhaust (if any), repairing the leakage of fuel, lubricating oil & coolant, repairing of accessories drive, Turbocharger and cranshaft endplay, rewinding of burnt armature of rotor/stator, greasing, cleaning, removal of carbon deposite and other unwanted remainants, re-assembling the complete engine, fixing it in position and testing on load complete all as sepcified & directed. Capacity :- 320 KVA DG Set. Note :- The spare parts as under, required for proper smooth funtioning shall be deemed to included in quoted unit rate for items.
Supply only FIP pump calibration -01 No
Supply only Valve set -24 Nos
Supply only Valve seat set -24 Nos
Supply only Head gas kit -01 No
Supply only Injector sleep-02 Nos
Supply only Top over hauling gas kit set -01 No
Supply only Head O ring set -01 Set
Supply only Control wiring -01 No
Supply only Control panel -01 No
Supply only Head set -12 Nos
Supply only House pipe set -01 Set
Supply only Water line -01 Set
Supply only Water Pump-01 No
Supply only Oil filter set -02 Nos
Supply only Air filter set -01 Nos
Supply only Diesel filter Set -02 Nos
Supply only Diesel filter Line -01 Nos
Supply only Injector Calibration -12 Nos
Supply & Fix fire alarm main control panel microprocessor based for 2 wire communication with 99 detectors and 99 modules and response indicators together with mimic diagram made on Auto CAD and pastedon Acrylic sheet with datalogging facility and 2 x16 character LCD, confirming to IS: 2189 complete with PA based evacation system and having its own mains/standby power supply with batteries etc. The panel shall also have an Auto dialling facility and potential free NO & NC contacts and a 80 watts PA amplifier. The Panel shall have a capacity of 12 loops/Zones complete all as specified and directed.Make:-Honeywell/APOLLO/Siemens /Moorley/ NSD/VEIGA
Supply & fixing & commissioning and testing of Intelligent Analogue Multi-Criteria (combination of smoke and heat) Detector including Isolator modules for short circuit isolation of signalling line cuircuit (SLC) with special algorithms to utilise information from both smoke and heat sensing elements to ensure high level of immunity to false alarms without compromising genuine alarm sensing performance, programmable multiple smoke senstivity level and 9 modes of operation, utilises fully digital communication protocol with high noise rejection. Approved by LPCB for EN 54-5, EN 54-7, & EN 54-17 standard complete all as specified and directed.Make:- SEIMENS/APOLLO/SYSTEM SENCOR/ HONEYWELL
Supply & Fixing & commissioning and testing of Intelligent Analogue Manual Call Point with resettable operating element, with in-built bi-directional short circuit isolator. Bi-Colour LED for local indication of device status, single action operation, reset to normal condition using special reset key, clearly visible alarm flag in the activated state. Approved by LPCB for EN 54-11 standard complete all as specified and directed.Make:-APOLLO/ HONEYWELL/ SYSTEM SENCOR/NSD/ VEIGA
Supply & Fixing & commissioning and testing of Conventional Wall Sounder with Beacon for providing Audible and Visual Alarms in response to the output signal from the control panel, and adjustable sound level, maximum output volume @ 1M distance 100 dB(A), output tone frequency range 440 Hz to 2900 Hz, Visual alarm device output frequency 0.5 Hz. Approved by LPCB for EN 54-3 standard complete.
Supply & Fixing remote repsonse indicator complete all as specified and directed
Supply & Fixing PVC insulated sheathed FRLS type. Armoured cooper cable conductor cable of size 1.5Sqmm 2 core complete all as specified and directed.
Supply & fixing of ceiling mounted clean agent HCFC (Hydrocroflurocarbons) & HFC (Hydrofluorocarbons ) based fire existingher /Supperession /system complete all as specified and directed by Eng-in-Charge. Note :- Rate quoted deemed to tbe inclusive of supporting iron angle with faster for holding of supperssion system
Supply and fixing of 3.0 TR capacity of Vertical Package Type units indoor/out door (Tower Ac) complete with cordless remote control unit, twin rotary compressor, three phase unit 220V, 50Hz of capacity 3.0TR (Non Inverter), complete all as specified and directed by Engr-in-charge. Make: Blue Star, voltas, Hitachi
Supply and fix in replacement Copper pipe 5/8 " outer dia all as specified and directed by Engr-in-Charge.
Supply and fix in replacement only Copper pipe 1/2" outer dia all as specified and directed by Engr-in-Charge.
Supply & fixing, testing and commissioning of AC box with 63 Amp 4 pole MCB connected with suitable lugs fixed in repairs complete all as specified & directed. Make: Legrand /Schiender / ABB/ L&T
Supply and installation of Smart Integrated Solar All In One Street Light 40 watt 120Lum/W, MPPT Charge Controller, LiFePO4 battery, Mono Crystalline Solar Panel, PIR motion sensor, easy installation on existing piles complete specified and directed by Engineer in Charge. Cat part No:BL38SSLX60W) of Crompton/ equivalent model of Havells/ Surya/Wipro as approved by GE.
M& L for 32mm dia light grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floor complete all as directed by Engineer in Charge.
M& L. for tubes 80mm dia medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floor complete all as directed by Engineer in Charge.
M & L. for PCC type B-1, (1:2:4) using 20mm graded aggregate stone aggregate , finished fair and even complete all as diected by Engineer in Charge
M & L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections Per including nuts, bolts, washers, welding, bending cold or hat, drilling holes for bolts, in any shape or size as indicated or directed and inclusive one coat of red oxide primer all as directed by Engineer in Charge.
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.00 MB
8788E8_TENDER_1.pdf
Tender Documents • 0.80 MB
Tender_Acceptance_Letter.pdf
Additional Documents • 0.08 MB
BOQ_834833.xls
BOQ • 0.67 MB
Workdetails.pdf
Additional Documents • 0.09 MB
8788E8_CreditSchdule_1.pdf
Additional Documents • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .