Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹2.9 L+₹705 (0.24%)Rejected-Finance GARRISON ENGINEER DIPATOLI MIL STN RANCHI PIN 900200 C O 56 APO | 900200 | L2 | Rejected-Finance Quoted Amt is more than L1. | |
| 3 | L3₹2.9 L+₹3,025 (1.04%)Rejected-Finance 27 2ND FLOOR CITY CENTRE CLUB ROAD RANCHI 834001 JHARKHAND | RANCHI | JHARKHAND | 834001 | L3 | Rejected-Finance Quoted Amt is more than L1. | |
| 4 | L4₹3.0 L+₹7,928 (2.74%)Rejected-Finance | L4 | Rejected-Finance Quoted Amt is more than L1. |
Tender Value
₹2.7 L
Closing Date
20 Mar 2023, 10:00 amClosed
MAJ S RAKESH
GARRISON ENGINEER RANCHI, 7TH CLUB ROAD RANCHI-834001
REPAIR/ REPLACEMENT OF LEAKAGE NEAR CM HOUSE IN MAIN PIPELINE FROM GONDA HILL TO ENGINEER LINE AT LPH UNDER GE RANCHI
2023_MES_585566_1
3017/2022-23/11/E3
Limited
Job Works
Works
30 days
GARRISON ENGINEER RANCHI
AS PER TENDER DOCUMENTS
3 documents required · 3 mandatory
₹0
Exempted
25 Apr 2023
13 Mar 2023
21 Mar 2023
14 Mar 2023
20 Mar 2023
15 Mar 2023
14 Mar 2023 - 14 Mar 2023
1. Excavation in trenches not exc. 1.5 m wide and not exc. 2 m in depth for laying pipe line and getting out in soft/ loose soil complete all as specified and as directed. -76Cum 2. Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick with soils complete all as specified and as directed. -68Cum 3. Removing of excavated material (soil) to distance not exc. 50 metres and deposited where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed. -8Cum 4. M & L for taking out DI water main pipeline of size 150 mm dia (including all fittings) with spigot and socket ends and lead joint including tyton joint of size 150 mm bore for relaying of serviceable pipe after cleaning complete all as specified and directed. Note : Excavation and earth work shall be measured and paid separately under relevant item. -95 Rm 5. M & L for relaying of serviceable existing DI pipeline of size 150 mm dia after rectification of defect against Item No. 4 all as specified and directed. -59 Rm 6. M & L for laying DI pipe of 150 mm bore with spigot and socket end centrifugally cast class K9 laid in trenches and connection to old or new position complete all as specified and directed. -36Rm 7. M & L for rubber tyton ring for 150 mm bore complete all as specified and directed. -15Each 8. M & L for replacement of mechanical joint 150 mm dia with fixing arrangement including dismantling complete all as specified and directed. -2Each 9. M & L for Cutting of road/hard standing for taking out of pipe/making new connection and making good with PCC (1:2:4) using 12.5mm graded store aggregate complete -3Cum Note : Schedual of Credit 19000.00
Engineering Services Company
Bihar traders
AD ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .