Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | Lowest₹4.0 LAccepted-AOC | Lowest | Accepted-AOC L1 | |
| 2 | Second₹7.9 LRejected-Finance KHASRA NO 183 10 SHYAM VIHAR HISAR HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | Second | Rejected-Finance L2 | |
| 3 | Third₹8.3 LRejected-Finance 790 STREET NO 1 PATEL NAGAR HISAR 125001 | HISAR | HISAR | HARYANA | 125001 | Third | Rejected-Finance L3 |
Tender Value
₹4.1 L
EMD Value
₹8,500
Closing Date
26 Jun 2020, 5:00 pmClosed
Ravi Ladwal, EE
Executive Engineer, Elect. Divn. PWD B and R Br., Hisar
Construction of Primary Health Center with Residential accommodation at Village Bansudhar in Distt. Sirsa (Pdg. Street/ Security Light only). RECALL
2020_HRY_129925_2
PWD/Elect-GGR/Elect-HSR/17346
Open Tender
Construction Works
Works
60 days
Hisar
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Executive Engineer, Elect. Division PWD B and R Br
₹8,500
11 Nov 2020
19 Jun 2020
29 Jun 2020
19 Jun 2020
26 Jun 2020
19 Jun 2020
Amount
1 i : - Miniature Circuit Breaker and Isolator. Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. (HSR 31.17) Miniature circuit breakers of 9 KA breaking capacity. ii) SP MCB 6 amp. to 32 amp.
ii : - iii) SPN MCB 6 amp. To 32 amp.
2 i : - Pipe Laying. Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. (HSR 31.21) xii) Galvanized iron pipe 40 mm dia on flushed.
ii : - xxvii) Galvanized iron flexible pipe complete with socket nipples and check nuts etc. at both ends ( upto length of 1 meter.) b) Size 20 mm dia.
iii : - xxviii) For additional length of Galvanized iron flexible pipe more than 1 meter ( the payment is to be made for additional length of pipe more than 1 meter only in item no. xxvii ). b) Size 20 mm dia.
3 i : - (Q) Earthing (HSR 31.22) i) Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required .
ii : - ii) Extra for using salt and charcoal / coke for pipe earth electrode as required.
iii : - xii) Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required.
4 i : - Supply and erection of under ground cable 1 meter below ground level covered with sand and bricks including necessary connections, digging and refilling of trenches. (HSR 31.25). xxxix) 10 Sq. mm 4 Core Ard. Cable .
5 i : - Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections. (HSR 31.26). v) 16 Sq. mm 2 Core Ard. Cable.
ii : - xxxix) 10 Sq. mm 4 Core Ard. Cable .
6 i : - Supply and erection of suitable compression type brass cable glands for underground Cable. (HSR 31.28). ii) 10 Sqmm to 16 Sqmm Cable 2 to 4 Core .
7 : - Street Light. (HSR 31.30). IV) Supply and erection of weather proof M.S.Box of size 20 cm x 15 cm x 10 cm. covered with 3.00 mm thick M.S.sheet hinged cover, locking arrangements , housed in wall , including the cost of 1 no. 16 amp. 415 volts kit-kat and 2 nos. 63 amp. 415 volts neutral links fixed on hard wood board in the M.S.Box including painting and necessary connections.
8 i : - S/E of PVC unsheathed copper conductor cable single core 1100 volts grad in pipe of suitable size excluding cost and erection of pipe. (HSR 31.40). i) Cable size 1.5 sqm(3/0.81 mm)
9 : - S/E of MS saddles and clamps on wall/ RCC parapet for fixing underground cable at a distance of 0.60 meter centre to centre fixed by means of rawl plug including the cost of all labour and material required to complete the job in all respect upto the Engineer-in-Charge of the work. (HSR 31.48).
10 : - Supply and erection of double walled corrugated (DWC) HDPE pipe laid 1 meter below ground level including digging and refilling of earth including cost of suitable size socket / coupler for HDPE pipe including the cost of the labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work. (HSR 31.67). i) HDPE pipe 63/50 mm outer dia/ inner dia
11 i : - Supply and errection of Hot Dip Galvanized octagonal pole 3 mm thickness, with base plate including of nut and bolts and all accessories as supplied by the manufacture including cost of foundation accessories etc. The foundation bolts as per manufacturer design should be hot dipped galvanized pole complete of 2 nos. 100 A, 4 pole nature links including connection etc with suitable connection arrangements for 2 no. MCB/ kit kat including cost of RCC 1:1:5:3 for foundation of size 0.7 m x 0.7m x 1.8 m with minimum 8 Nos. 12 mm dia longitudinal MS reinforcement rods with rings of 8 mm dia not more than 200 mm CC for fixing the pole with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Make Bajaj/ Philips/ Surya Roshni/ Skipper. (HSR 31.68). i) 7 M long pole with top dia 70 mm and bottom dia 130 mm with base plate of size 220 x 220 x 12mm.
12 : - Non Schedule items Supply/ errection/ testing / commissioning of digital main switch- cum- pedestal- cum -distribution board -cum street light panel of 32 amp 3 pole / 230 Volts with digital time switch having suitable size of 1 No. 40 amp TPN MCB, 1 no. 32 amp TP contactor, 1 HRC fuse , 1 Indicator & 2 No. TP MCB 32 amp having IP 52 Degree protection all items should be of same make / manufacturer including padestal, including making connection and petty material required to complete the job in all respect upto the entire satisfaction of Engineer-inCharge of the work. (Make:- IndoAsian/ Havell's/ Standard).
13 : - Supply & Erection of double arms bracket made of 32/50mm dia GI pipe B class ISI 1.20 mtr. Long with coller pipe (GI) 75mm dia 60cm Long top covered with ornamental cap duly welded, painted 2 coats of aluminum paints on bracket and golden paint of ornamental cap including the cost of labour and petty material etc. complete in all respect upto the entire satisfaction of Engineer-incharge. Bracket duly erected on existing 7/9 Mtr. High Octagonal pole.
14 : - Supply and erection of 25 W LED Post lantern new generation energy saving envirmental friendly long life aesthetically designed with symmetrical light distribution, spen aluminum land scap luminaries with high power LED as light source with the protection of IP-65 of LHEVBGP7PN 6K 025 (Rubby clear) of Havell's make/ BLPTSP 25 W NW LED of Bajaj make/ LPTH-20- CDL of Crompton make complete with all accessories and labour to complete the job upto the entire satisfaction of Engineer-in-charge of the work.
15 : - S/E of 60 W LED Flood light luminaries with high power LED 110 Lumens per Watt Philips / Havell's /Wipro/ Crompton/ HPL make in aluminum pressure die casting housing toughened glass cover with IP-66 protection With Lense and dual surge protection device internal 5 KV and external 10 KV including all petty material with labour for errection, complete in all respect of Engineer-in-Charge of the work. (For Top of Building).
16 : - S/E of 60 W LED street light fitting < 100 Lumens per Watt Philips / Havell's / Wipro/ HPL make in aluminum pressure die casting housing toughened glass cover with IP-66 protection With Lense and dual surge protection device internal 5 KV and external 10 KV including all petty material with labour for errection, complete in all respect of Engineer-in-Charge of the work. .
Dhamija Power Constructions
M/s JSB Enterprises
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .