Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.5 LAdmitted-Finance | ₹44.5 L | L1 | Admitted-Finance |
| 2 | Rejected-Technical 0 CHINHAT LUCKNOW UTTAR PRADESH 227105 UDYAM UP 50 0067162 | 227105 | - | - | Rejected-Technical Technically Not Qualified |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically Not Qualified |
| Sl No | Description | Qty | Unit | Siddhivinayak Enterprises L1 |
|---|---|---|---|---|
| 1.00UP- GRADATION OF ELITE HOSTEL AND ALLIED ELECTRICAL WORKS AT SAI NSRC LUCKNOW | ||||
| 2.00 | Providing and fixing powder coated aluminium work (minimum
thickness of powder coating 50 micron) consisting of tee/ angle
sections, of approved make conforming to IS : 733 in frames of falseceiling including aluminium angle cleats with necessary C.P. brass/stainless steel sunk screws, aluminium perimeter angles fixed towall with stainless steel rawl plugs @ 450 mm centre to centre andfixing the frame work to G.I. level adjusting hangers 6 mm dia. withnecessary cadmium plated machine screws all complete as perapproved architectural drawings and direction of the Engineer-incharge(level adjusting hangers, ceiling cleats and expansion holdfasteners to be paid for separately). | 163.98 | kg | 67,231.8 ₹67,231.80 |
| 3.00 | Providing and fixing false ceiling at all heights with integral densifiedcalcium silicate reinforced with fibre and natural filler false ceilingtiles of Size 595x595mm of approved texture, design and patternsas per CPWD Specification 2019, to be laid in true horizontal levelsuspended on inter-locking metal T-Grid of hot dipped galvanisediron section of 0.33mmthick (galvanized @ 120 grams per sqmincluding both sides)comprising of main-T runners of size 24x38mm of length 3000 mm,cross - T of size 24x32 mm of length1200 mm and secondary intermediate cross-T of size 24x32 mmof length 600mm to formgrid module of size 600 x 600 mm,
suspended from ceiling usinggalvanised mild steel items (galvanizing@ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm diafully threaded hanger rod upto 1000 mm length and L-shape leveladjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require,fixed with Glavanised iron perimeter wall angle or size 24x24x0.40mm of length 3000 mm to be fixed on periphey wall / partition withthe help of plastic rawl plugs at 450mm center to center and 40 mmlong dry wall S.S screws. The workshall be carried out as perspecifications, drawing and as per directionsof the Engineer-in-Charge. With 15 mm thick Tegular edged lightweight calciumsliciate false ceiling tiles | 128.21 | sqm | 1,25,645.8 ₹1.3 L |
| 4.00 | Kota stone slab flooring over 20 mm (average) thick base laid over and
jointed with grey cement slurry mixed with pigment to match the shade
of the slab, including rubbing and polishing complete with base of cement
mortar 1 : 4 (1 cement : 4 coarse sand) :
25 mm thick | 15.68 | sqm | 54,880 ₹54,880 |
| 5.00 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm
(thickness to be specified by the manufacturer) of 1st quality conforming
to IS : 15622 of approved make in colours such as White, Ivory, Grey,
Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :
4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including
pointing the joints with white cement and matching pigment etc.,
complete. | 7.84 | sqm | 7,683.2 ₹7,683.20 |
| 6.00 | Providing and laying vitrified floor tiles in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08%
and conforming to IS: 15622, of approved make, in all colours and shades,
laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),
jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the
joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mm | 32.05 | sqm | 44,870 ₹44,870 |
| 7.00 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to
IS: 15622 (thickness to be specified by the manufacturer), of approved
make, in all colours, shades except burgundy, bottle green, black of
any size as approved by Engineer-in-Charge, in skirting, risers of steps
and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3
coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,
including pointing in white cement mixed with pigment of matching shade
complete. | 5.23 | sqm | 8,263.4 ₹8,263.40 |
| 8.00 | Providing and fixing fly proof galvanized M.S. wire gauge to windows
and clerestory windows using wire gauge with average width of aperture
1.4 mm in both directions with wire of dia 0.63 mm all complete. With 12 mm mild steel U beading | 16.63 | sqm | 44,734.7 ₹44,734.70 |
| 9.00 | Steel work welded in built up sections/ framed work, including cutting,
hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works | 195.84 | KG | 41,126.4 ₹41,126.40 |
| 10.00 | Making connection of drain or sewer line with existing manhole
including breaking into and making good the walls, floors with cement
concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) cement plastered on both sides
with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a
floating coat of neat cement and making necessary channels for
the drain etc. complete : For pipes 100 to 250 mm diameter | 1 | each | 1,660 ₹1,660 |
Tender Value
Refer Docs
EMD Value
₹81,210
Closing Date
28 Feb 2026, 2:00 pmClosed
Regional Director
Sport Authority of India, Sarojini Nagar, Lucknow
UP- GRADATION OF ELITE HOSTEL AND ALLIED ELECTRICAL WORKS AT SAI NSRC LUCKNOW
2026_SAI_899196_1
SAI/LKO/INFRA/2025-26/ELITE CAMP/CN-112487
Open Tender
Electrical Works
Sport Authority of India, Sarojini Nagar
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹81,210
Yes
11 Mar 2026
18 Feb 2026
2 Mar 2026
18 Feb 2026
28 Feb 2026
18 Feb 2026
18 Feb 2026 - 26 Feb 2026
UP- GRADATION OF ELITE HOSTEL AND ALLIED ELECTRICAL WORKS AT SAI NSRC LUCKNOW
Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of falseceiling including aluminium angle cleats with necessary C.P. brass/stainless steel sunk screws, aluminium perimeter angles fixed towall with stainless steel rawl plugs @ 450 mm centre to centre andfixing the frame work to G.I. level adjusting hangers 6 mm dia. withnecessary cadmium plated machine screws all complete as perapproved architectural drawings and direction of the Engineer-incharge(level adjusting hangers, ceiling cleats and expansion holdfasteners to be paid for separately).
Providing and fixing false ceiling at all heights with integral densifiedcalcium silicate reinforced with fibre and natural filler false ceilingtiles of Size 595x595mm of approved texture, design and patternsas per CPWD Specification 2019, to be laid in true horizontal levelsuspended on inter-locking metal T-Grid of hot dipped galvanisediron section of 0.33mmthick (galvanized @ 120 grams per sqmincluding both sides)comprising of main-T runners of size 24x38mm of length 3000 mm,cross - T of size 24x32 mm of length1200 mm and secondary intermediate cross-T of size 24x32 mmof length 600mm to formgrid module of size 600 x 600 mm, suspended from ceiling usinggalvanised mild steel items (galvanizing@ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm diafully threaded hanger rod upto 1000 mm length and L-shape leveladjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require,fixed with Glavanised iron perimeter wall angle or size 24x24x0.40mm of length 3000 mm to be fixed on periphey wall / partition withthe help of plastic rawl plugs at 450mm center to center and 40 mmlong dry wall S.S screws. The workshall be carried out as perspecifications, drawing and as per directionsof the Engineer-in-Charge. With 15 mm thick Tegular edged lightweight calciumsliciate false ceiling tiles
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 12 mm mild steel U beading
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand)
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand)
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : Ply wood 7 ply, 9 mm thick, Decorative plywood one side decorative veneerand commercial veneer on other face (Type 1) conforming to IS 1328 BWR Type
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only: 1.5 TR with 5 Star BEE Rating (make mitsubishi,ogeneral,or equivalent)
Supplying, Installation, Testing and Commissioning of AirCooled Cassette type Air conditioners complete with Indoorunit(IDU), Out door unit (ODU), R-32/R410A/R-407 GreenRefrigerant, wireless Remote, inbuilt drain pump, suitablefor 400/230V, 50 Hz ,1 /3 phase AC supply, includingsurface / concealed copper Refrigerant piping withinsulation (closed cell elastomeric nitrile rubber tubular pipesection) upto 5.5 Mtr (IDU to ODU), copper power andcontrol cable upto 5.5 Mtr (IDU to ODU) including drainpipe, the system shall be capable of performing cooling,dehumidification, Air circulation, filteration & ventilation offollowing capacity with Scroll/rotary compressor with min 5year Original Equipment Manufacturer (OEM) warrantyboth compressor and Printed Circuit Board (PCB) asspecified. The system shall be able to deliver 100% of therated capacity as per relevant IS Code. The lab testingreports as per IS: 1391 shall be submitted from NationalAccreditation Board for Testing and CalibrationLaboratories (NABL) accredited as per InternationalElectrotechnical Commission (IEC) 17025standards/Central Power Research Institute (CPRI)/Electrical Research and Development Association(ERDA)with Original Equipment Manufacturer (OEM) etc.complete as per CPWD specification and as per IS: 1391as required.Inverter Type- Cooling only : 2.5 TR with 5 Star BEE Rating (make mitsubishi,ogeneral,or equivalent)
Supply & installation of LED surface light (with frame) 60X60cm of 30W capacity all complete as per direction of EIC (make: philips,Wipro or equivalent).
Supplying, Installation, Testing and Commissioning of centralized exhaust system comprising of following systems 1. Kitchen Exhaust & Fresh Air Exhaust Fan4000 CFM 35mm SP(Qty-1 nos) 2. SITC of Fresh Air System for Kitchen (Qty-1 nos) 3. Fabricated GI Duct SITC of Factory Fabricated GSS Sheet meta rectangular Ducting complete with Neoprene rubber gasket, Elbows, splitter dampers , vanes , hangers, supports etc as per approved drawing and spectication of the following sheet thickness complete as require.(Qty-550 Sqft.) 4. Grilles SITC of Powder coated Aluminium extruded Grills (Qty-07 nos) 5. Exhaust Hood SITC of fabricated Stainless Steel SS-304 Exhaust Hood with Baffe Filter (Qty-18 nos) including Installation Charges & Freight Charges all complete as per direction of EIC(make: Daikin, airvex or equivalent)
Un-Installation of existing window/split/cassate AC including all accessories & fittings and repairing of walls & closing the openning with requisite materials as per specifications with seepage treatment all complete as per direction of EIC.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
BOQ_945159.xls
BOQ • 0.31 MB
TenderDoc.pdf
Tender Documents • 1.72 MB
Download all tender documents and submit your bid