Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC G 86 DATA RAM SECTOR 18 ROHINI NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.8 L+₹4.0 L (21.2%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹23.1 L+₹4.3 L (22.8%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹23.8 L+₹5.0 L (26.5%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹26.5 L+₹7.7 L (40.9%)Rejected-Finance 67 AASANI BAS PALANA PALANA BIKANER BIKANER RAJASTHAN 334402 UDYAM RJ 08 0063520 | BIKANER | RAJASTHAN | 334402 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
10 Aug 2021, 6:00 pmClosed
GE (N) DELHI CANTT-10
GE (N) DELHI CANTT-10
REPAIR MAINT OF INTERNAL ELECTRIFICATION WORK INCL REPLACEMENT OF VARIOUS UNSV LIGHT FITTINGS FIXTURES DBs ETC IN VARIOUS OFFICE COMPLEXE ACCN AT AIRPORT RD NO 4 POULTARY FARM 226 ARMY SUPPLY CORPS MAP FAFA JCOs ORs ACCN KABUL LINE AND REPAIR MAIN
2021_MES_459454_1
GE/NORTH-35/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (N) DELHI CANTT-10
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (N) DELHI CANTT-10
₹80,000
Yes
16 Sept 2021
13 Jul 2021
12 Aug 2021
13 Jul 2021
10 Aug 2021
27 Jul 2021
Amount
Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing all as specified and directed.
M&L for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for One light / bell / buzzer point controlled by one, one way switch 06 Amps.
All as above item No 2 here-in-before but one fan point controlled by one, one way switch 06 Amps.
All as above item here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch.
All as above item here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
All as above item here-in-before above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
M&L for point wiring with single core fire retardant low smoke PVC insulated, unsheathed multi stranded copper conductor of size 1.5 sqmm alongwith 1.5 sqmm earth wire of multi strand copper conductor (with same specification) drawing through existing conduit pipe including sheet metal concealed boxes,cover plate, joint boxes etc complete all as specified and directed for One light /fan/ bell point controlled by one, one way switch 06 Amps.
All as per above item here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch.
All as per above item here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, on here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
All as per above item here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, on above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
S&F switch piano flush type, 06 Amps, single pole, one way, 230 volts complete
S&F bell push, flush type, 06 Amps, 230 volts with switch frame complete
S&F switch piano flush type, 16 Amps, single pole, one way, 230 volts with switch frame complete
S&F socket outlet 2 in 1, 5 pin, 06 Amps, flush type, 230 volts with socket frame complete
S&F socket outlet 2 in 1, 3 pin, 06 Amps and 3 pin, 16 Amps, flush type, 230 volts with socket frame complete
Supply and fixing modular socket outlet 02 in 01, 03 pin, 06 Amps and 16 Amps, 02 module switch socket combination with shutter complete all as specified & directed.
S&F ceiling fan regulator , stepped type of 0 to 04 rotary steps, electronic, 2 Module socket type, humfree, AC, 230 volts, 100 watts complete
All as per above item here-in-before but 1 Module.
Supply and fixing ding dong bell, AC, 230 volts, single pole complete all as specified & directed.
Supply and fixing ceiling rose, 6 Amps, 230 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete all as specified & directed.
Supply and fixing lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting including 9W LED bulb complete all as specified & directed.
Supply and fixing in repair decorative wall mounting, S.S finish fixture with opal PC diffuser suitable for 10/12 watt LED Lamp, lamp holder, including 12 Watts LED bulb of 6500 K of B22 base cap and all accessories pre-wired including connecting up complete all as specified and directed.
Supply and Fixing in repair surface and wall mounted LED batten 10 watt 2 feet long extruded aluminium housing provided for efficient heat dessipation with polycarbonate diffusser and integrated electronic drive suitable for mirror fittings, all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repair on wall / ceiling LED batten lighting fixture 18 watts LED 5700K (4'), with extruded aluminium heat sink, integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete
Taking down of exsting u/s tube light fitting and supply and fixing in repair on surface and wall mounted LED batten with polycarbonate housing and initigarated electronic drive 20 Watt fixture 4 feet provided for efficient heat dissipation with policorbonate diffuser and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete all as specified and directed.
Supply and fixing in repair on wall energy saving, eco friendly LED bulk head fitting 10Watt, IP 65surface mounted with ABS body & polycarbonate diffuser, etc and all accessories pre-wired including connecting up including taking down of existing u/s light fitting complete all as directed.
S&F in repair ultra modern recess mounting 36 Watts, 5700K, 2x2 LED flat panel complete with integrated electronic driver, soft-light and glare free symmetrical illumination, suitable for POP ceilings high brightness SMD LEDs, etc including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete
Taking down of existing u/s surface/recessed light fitting and supply & fixing mounting 30/36 Watts in CDL , 4x1 LED flat panel complete with envornmental friendly, ultra modern recess mounting luminaries with high brightness SMD LEDs as light source suitable for ceilings high etc including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete all as directed.
Removal of UNSV fitting, Supply and fixing garden light fitting 10 watts, IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution including taking down old fitting, demoliton of brick/PCC work all as specified and directed. (Make :Crompton LBLSN 10 CDL or equivallant inHavells/Philips) (Note: Necessary PCC works shall be measured and paid separately under relevant items)
Supply and fixing in repair ultra bright compact 6/8 Watt round LED downlighter recess/surface with high efficiency LED,s idealy suited for low ceiling areas to give glare light IP-54 in 6500K with integraed driver to delivered superior light output and uniformity utilising the latest LED technology, ceiling cutout 95 mm mm dia hight max 83 mm recess luuminaries all as specified and directed.
Supply and fixing in repair 12 Watt round LED panel recess/surface mounting downlight in CDL with integraed driver to delivered superior light output and uniformity utilising the latest LED technology, ceiling cutout 145mm mm dia hight max 35mm recess luuminaries all as specified and directed.
Supply and fixing in repair 15 Watt round LED panel recess/surface mounting downlight in CDL with integraed driver to delivered superior light output and uniformity utilising the latest LED technology, ceiling cutout 145mm mm dia hight max 35mm recess luuminaries all as specified and directed.
Taking down of exiting u/s security light fitting and supply and fixing energy saving LED security light fitting with lens of 45 watts Versatile pressure die-cast aluminium IP 66 roadway luminaire with high power LED as light source comprising with electronic driver and all accessories pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and suitable GI tube bracket for mounting of light fitting, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of suitable flat iron clamps, nuts, bolts and washers etc complete all as specified and directed.
Supply and fixing ceiling fan 400mm sweep, cubid type with built in LED light and remote control in white colours with connections including necessary cutting in ceiling complete all as directed by Engr - in - charge.
Supply and fixing Ventilating fan wall mounted type of 250 mm sweep, 230 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed by Engineer - in - charge.
Supply and fixing Ventilating fan wall mounted type of 200 mm sweep, 230 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed by Engineer - in - charge.
Material and labour for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed, including taking down old sub main wiring.
All as above but 06 Sqmm nominal cross sectional area two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 4.0 Sqmm nominal cross sectional area, single core.
All as above but 10 Sqmm nominal cross sectional area, four single core, with and including continuous earth wire of size 06 Sqmm nominal cross sectional area.
Supply & fixing in repair industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 230 volts of 20 Amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply and fixing in repair sheet metal enclosure distribution board, single pole and neutral, AC, 230 volts, 08 way, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified directed.
All as above item but sheet metal enclosure distribution board, single pole and neutral, AC, 230 volts 12 way.
Supply and fixing in repair sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 200 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed and comprising of the following:- Make :-Legrand/Havells/Indoasian/Schneider (a) MCCB, 125 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete - 01 No. Make :- Legrand/Havells/Indoasian/Schneider (b) MCB, SP, AC, 230 volts of 10 to 32 Amps, "C" curve, 10 KA breaking capacity - 12 Nos.
Supply and fixing in repair MCB, SP, AC, 230 volts of 10 to 32 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supply and fixing in repair MCB, DP, AC, 230 volts of 40 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supply and fixing in repair MCB, DP, AC, 230 volts of 63 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supply and fixing in repair 40 Amps 4 Pole 30 mA RCD add on block 10 KA rated conditional short circuit current (Icc) 35 sqmm terminals, dual position DIN Clip, confirming to IEC 60947-2 and 40 Amps single pole 'C' type MCB Confirming to IS/CE Marked as per IS/IEC60898-1, rated short circuit breaking capacity Icn 10 KA, enerergy limitation class 3, line load reversiblity, 35 sqmm terminals, biconnect terminals all as specified and directed by Engr-in-charge.
Supply & fixing in repair MCCB, 125 Amps,TP, AC, 415 Volts of 16 KA breaking capacity complete all as specified & directed.
Supply & fixing in repair MCCB, 100 Amps, FP, AC, 415 Volts of 16 KA breaking capacity complete all as specified & directed.
Supply & fixing in repair MCCB, 63 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete all as specified & directed.
Supply & fixing in repair MCCB, 40 Amps, 02 pole, AC, 415 Volts of 16 KA breaking capacity complete all as specified & directed.
Supply install testing and comissioning of Building common area panel including Contacto, Analog time switch, MCB rating 40 Amps suitable for 3 phase 415 volts and having over and under voltage protection relay to protect the contactor coil, outdoor with panel locking facility, wall/floor mounted type including necessary cable lugs and gland in repairs all as specified and directed by Engr-in Charge.
Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed.
S&F in repair of 3mm thick plastic laminated sheet cover with brass screws , cup wahser and cutting of grooves for switchs,scoket and regulator etc complete for following sizes as directed by engr-in-charge .
Taking out ceiling fan of any sweep from its position and disconnecting of electric connection from ceiling rose for repair/rewinding cleaning complete removing all scale and dirt after cleaning opening the fan servicing oiling greasing and replacement of defective parts like bush bearing, minor rubber parts, connectors,bolts, nuts and unsv flexible connection wire upto 1 metre length complete and reassembling after repairs and re-fixing its original position all as specified. Note :- The new parts required shall be supplied under relevant items herein after and shal be measured and paid separately.
Rewinding of burnt winding from the stater of the ceiling fan 1200 mm sweep with matching gauge and turns of superenamelled copper wire leathenic paper, glass sleeves etc including varnishing the windings and testing complete all as specified and as directed.
All as per above item No. 2 but for 1400 mm Sweep.
Supply only ceiling fan bearing (6201&6202) for 1200/1400mm sweep.
Supply only capacitor 2.5 Mfd, 240 Volts as existing position
Supply only PVC canopy for ceiling fan of
Supply only Rubber bush with MS Bolt and Nut
Taking out exhaust fan of any size from its position, removing all scale and dirt, after cleaning opening the fan, servicing oiling greasing and replacement of defective parts like bush bearing etc complete and reassembling after repairs and re-fixing to its original position after repair (Part shall be measured and paid separately).
Rewinding of burnt winding of the Exhaust fan 300 mm sweep with matching gauge and turns of superenamelled copper wire leathenic paper, glass sleeves etc including varnishing the windings.
Taking down carefully electric geyser of any type and capacity by disconnecting electric and water supply connection, opening nut, bolt, washer and replacing the defective parts and reassembling after cleaning and replacing defective parts and re-installing the same in original position and making necessary electric and water supply connection and testing complete all as specified and directed by Engineer -in-Charge. (Items shall be measured and paid seperately)
Supply only inner tank, vessel made of steel sheet 22 gauge all as specified and approved by Engineer-in-Charge at site ( ISI marked) suitable for 25 ltr capacity
Supply only of Heating element capacity 1.5 KW suitable for 25 Ltrs geyser of Recold make (as per sample) complete all as specified and directed by Engineer-in-Charge.
Supply only thermostat suitable for 25 Ltrs geyser of Recold make (as per sample) complete all as specified and directed by Engineer-in-Charge.
Supply only PVC connection high pressure type suitable for hot water connection as per sample.
Supply only PVC connection pipe with brass unions at both ends, 450mm long 15mm bore (for incoming cold water) all as specified and as directed.
Supply only apparatus plate suitable for 25 ltrs capacity geyser.
Supply & Fixing PVC insulated and sheathed flexible cable 3 core Multi-stranded copper conductor size 2.5 Sqmm 1100 volt grade after taking out old unserviceable one including electric connection complete all as specified and directed.
S&F in replacement of concealed metal box 06/08 modules having high durability,corrosion resistant,earthing terminal with repalcement of 3 mm thick plastic laminated hylam sheet top cover with brass screws , cup wahser and cutting of grooves for switchs,sockets and regulator etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed.(Note: Switch,sockets,regulators to be measured and paid separately)
All as per item No 72 above item description but 03/04 modules complete.
All as per item No 72 above item description but 01/02 modules complete.
Sch of Credit- Total contract sum shall be calculated after deduction of Sch of Credit amount Credit amount - 103334.00
M/s S.G. BUILDERS
M/s Prakash Enterprises
M/s Sohanil Construction
S. S. CONSTRUCTION CO.
Shiv Enterprises
Ridhi engineers and builders
Surjit and Sons
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .