Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.7 LAccepted-AOC | L1 | Accepted-AOC Being First Lowest | |
| 2 | L2₹30.6 L+₹77,881.85 (2.61%)Rejected-Finance | L2 | Rejected-Finance Other Than First Lowest | |
| 3 | L3₹34.6 L+₹4.7 L (15.8%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L3 | Rejected-Finance Other Than First Lowest |
Tender Value
Refer Docs
EMD Value
₹78,000
Closing Date
29 Sept 2023, 6:00 pmClosed
GE Lalgarh Jattan
GE Lalgarh Jattan
PROVN OF CONSTRUCTION OF TOE WALL AND CERTAIN REVENUE WORKS AT LGJ MIL STN
2023_MES_616714_1
8934-37/GE/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE Lalgarh Jattan
As per tender document
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹78,000
Yes
11 Jan 2024
1 Sept 2023
2 Oct 2023
1 Sept 2023
29 Sept 2023
15 Sept 2023
Amount
Excavation in trenches n.exc. 1.5m wide and n.exc 1.50 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc. 10 Sqm on plan and n.exc 1.5 m in depth and getting out in getting out in sof / loose soil all as directed.
M&L for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base below floors all specified and directed.
M&L for old size brick work with fly ash bricks straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) all as specified & directed.
M&L for PCC 1:2:4 type B0 using 12.5 mm graded crushed stone aggregates as in coping including necessary formwork etc. all as specified & directed.
M&L 15mm thick rendering on brick surfaces of wall in CM 1:4 finished even and smooth without using extra cement including mixing of WPC compound complete all as specified and directed. (WPC Shall be paid separately)
M&L for preparation of new plastered or pointed surface of walls and applying two coats of cement base paint over one coat of primer complete all as specified & directed by Engr-in-charge.
S&F 75 mm dia bore PVC SWR pipe, single socketed in any length with rubber ring joints laid in trenches or in floors or wall as weep hole complete all as specified and directed.
Returning filling in incl spreading, levelling watering and well ramming in layer n.exc 25cm thick complete all as specified and directed.
Removing excavated material to distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L fly ash brick work with sub class 'B' brick straight or curved on plan exc 6m mean radius in CM 1:4 complete all complete and as specifed and directed.
M&L for 40mm thick damp proof course in cement concrete 1:2:4, type B-0, 12.5 mm graded stone aggregate to horizontal or vertical surfaces including necessary formwork complete all as specfied and directed by Engr-in-Charge.
M&L for reinforced cement concrete, type B1 1:2:4 using 20 mm graded stone aggregates in lintels upto 1.5m span, cills steps, seismic and other similar bands, plinth courses, copings, bed plates, and the like including weathering, slightly rounded or chamfered angles and throating, incl formworks all as specified and directed. Note : Reinforcement shall be measured and paid separately
M&L for formwork to sides and soffits of floor or roof beams, beam hunchings, girders, bressummers, lintels, cantilevers, etc. also splays between floors and beams, etc. rough finish surface of concrete flat complete all as specified and directed by Engr-in-charge.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc 200 mm thick (horizontal or sloping) rough finish surface of concrete flat complete all as specified and directed by Engr-in-charge.
M&L for reinforced cement concrete (design mix) M-25 using 20mm graded stone aggregrate in slabs support on walls, beams and columns in floors, roof slab landing balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-in-charge.
M&L for reinforced cement concrete (design mix) M-25 using 20mm graded stone aggregrate in wall, retaiining wall, basement wall, ballast wall and the like; any thickness; above top of footings complete all as specified and directed by Engr-in-charge. Note : Reinforcement shall be measured and paid seperately
S&F for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-charge.
,---ditto--- all as per item No 17 above here-in-before but TMT bars of 5 mm and over complete all as specified and directed by Engr-in-charge.
Spreading and levelling in layer n.exc 25 cm thick and well reamming including watering as required under floors all as directed (in floor with available earth from excavation approved by Enginner-in-charge)
M&L for broken stone hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc.15cm thick, watered and rammed to a true surface (15cm compacted thickness) complete all as specified and directed by Engr-in-charge.
M&L for 75mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base below floors complete all as specified and directed by Engr-in-charge.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor all as specified and directed.
M&L for glazed ceramic coloured tiles of size 350 x 250 x 7 mm thick on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the floor all as specified and directed.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 20 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as directed.
M&L rendering 10 mm thick cement plaster on brick walls or concrete, surface in CM 1:6 and surface to be finished even smooth without using extra cement complete all as specified & directed
M & L rendering 5 mm thick in cement mortar (1:3) on fair faces of concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified & directed by Engr-in-charge.
Supply only liquid water proofing compound complete all as specified and directed by Engr-in-charge.
M&L for three coats of white wash on newly plastered surfaces incl preparation etc. on wall complete all as specified and directed by Engr-in-charge.
M&L for three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces complete all as specified and directed by Engr-in-charge.
S&F for factory made steel ventilators all as per IS 1038/83, with top hung shutters including hinges, steel peg stay, complete all as specified & directed by Engineer-in- charge.
M&L for preparation of new steel surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge.
S&F 4.0 mm sheet glass ordinary quality and glazing with oil putty or with beading in square n.exc 0.5sqm in each pane complete all as specified and directed by Engr-in-charge.
Supply and fixing of Fibre glass Reinforced plastic (FRP) door frame of required colour of cross-section 90mm x 45mm having single ribate of 32mm x 15mm to recieve shutter of 30mm thick including laminated door frame moulded with fire retardant grade unsaturated polyster resin and chopped strand mat(CSM) also door frame laminated shall be 2mm thick and shall be filled with suitable wooden block of 2nd class hard wood, frame shall be covered with fibre glass from all sides. MS stay flat iron 25mm x 3mm shall be provided at the bottom to steady the frame complete all as specified and as directed by Engineer-in- charge.
Supply and fixing of 30 mm thick glass fibre reinforced plastic (FRP) paneled door shutter conferming to IS:14856-2000 of required colour and made with fire retardant grade unsaturated polyster resin,moulded to 3mm thick FRP laminated for forming hollow rails and style with suitable second class hardwood timber block inside at required places for fixing of fittings,cast molithically with 5mm thick FRP laminated for panels including fixing to frames,complete all as specified and as directed by Engineer-in- charge.
S&F for 100 mm long butt hinges, stainless steel fixed complete all specified and directed.
S&F for 200 mm long aluminium anodised barrel tower bolt, of extruded sections complete all as specified and directed.
S&F for 150 mm long aluminium anodised handle, cast type complete all as specified and directed.
S & F Vitreous China urinals, half stall complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; grating and Union for discharge pipe complete all as specified and directed.
S & F vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests com plete including provision of lime concrete bedding complete all as specified and directed.
S&F white vitrieous china wash down WC (Pedestal pattern) of size 630mm X 350mm X 790mm with fixing bolt, plastic water closed seat cover, white closed pattern with flat bottom, and cover with aluminium hinging device, including all connection complete all as specified and directed by Engr-in-charge.
S&F vitreous china wash hand basin coloured of size 550 x 400 mm with, 32mm dia chromium plated waste coupling long screwed shank, including cutting for and pinning in ends of brackets in 1:3 CM complete all as specified .
Supply and fixing PVC valve less, syphonic action type flushing cistern,10 ltrs capacity low level, white, with inlet ball valve, float, handle and connection to pipe and flush pipe of polyethylene of low or high density or PVC, 32mm dia, for low level cistern complete all as specified and directed by Engr-in-charge.
Supply and fix bib taps, cast copper alloy fancy type chormium plated long body. with Capastan head screwed down screwdd for iron pipe of brass ferrule, and fixed in 15 mm bore dia of pipe complete all as specified and directed by Engr-in-charge.
S&F 15 mm dia stop valve, fany type chromium plated , cast copper alloy, screwed down, high pressure, with capastan head, screwed both ends for iron pipe complete all as specified and directed by Engr-in-charge.
S&F PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed by Engr-in-charge.
S&F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed by Engr-in-charge.
S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as directed.
S&F 20mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as directed.
S&F 25 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as directed.
S&F gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore all as specified.
Supply & fixing 100 mm bore cast iron pipe, spun cast, waste and vent pipe in any length with or without ears laid in trenches/floor/wall including clamps, jointing complete all as specified & directed by Engr-in-charge.
Supply & fixing 75 mm bore cast iron pipe spun cast waste and vent pipe in any length with or without ears laid in trenches/floor/wall including clamps, jointing complete all as specified & directed by Engr-in-charge.
S&F 100mm bore cast iron type plain bends (any radius) diminishing pieces or tapers (larger bore measured) door fixed complete all as specified and directed by Engr-in-Charge.
S&F 75 mm bore cast iron type plain bends (any radius) diminshing pieces or tapers (larger bore measured) complete all as specified and directed by Engr-in-Charge.
S&F PVC vent cowl 100mm complete all as specified and directed by Engr-in-charge.
S&F in repair 75mm bore cast iron plain bends with oval access door (any radius) pieces or tapers (larger bore measured) fixed complete all as specified and directed by Engr-in-Charge.
S & F cast iron 100 mm bore branch pieces, single (equal or unequal),ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed by Engineer-in-Charge.
S & F cast iron floor trap (dia of outlet 75 mm) , with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed by Enginner-in-charge
S&F rotational moulded polythene water storage tank 500 ltr capacity vertical with closed top hoisted and fixed in position all as specified in SSR part-I. complete all as specified and directed by Engr-in-charge.
M&L precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate and set cement mortar 1:6 as in cover slabs (for manholes etc,) chajjas, shelves and similar articles with plain faces complete all as specified and directed by Engr-in-charge.
Supply and laying DWCPE (SN8) 180 (OD)/163 (ID) mm diameter drain pipes as per IS-16098 (Part-II), laid in trenches on PCC bed to required slope, including all accessories/fittings, jointing and tested complete all as specified and as directed by Engineer-in-Charge. Note : PCC and earth work shall be measured and paid separately.
M & L for size 1.5 m dia x 3.00 m effective depth of soakage well excavation in any type of soil, foundation in PCC 1:3:6, wall of honey combed mansory, with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick mansonry in CM, RCC cover slab in M-25, SFRC cover inter connection pipe of RCC/DWC complete filled with brick bats all as specified and directed (Ref Drg No BTD-804)
M & L cement concrete type B-1, 1:2:4 (20mm graded crushed stone aggregate) as in benching /haunching manhole including forming channels Complete all as specified.
M & L for on site convetional type septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft connection etc complete for 25 users all as specified and directed (Ref drg No BTD-016)
M&L Machined pressed precast concrete interlocking paver block glossy with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade laid over Fazilka sand cushion 25 mm thick all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm in thickness (below or above ground level) complete all as specified and directed by Engr-in-charge.
M&L for 50 mm thick cement concrete type B0, 1:2:4 (12.5 mm graded stone aggregate) as in floor of SWT finished even and smooth without using extra cement complete all as specified.
Taking down cement plaster from brick/stone wall including raking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed.
S & F chicken wire mesh dip coated iron, shape of mesh hexagonal, dia of wire 0.38 mm including fixing with nails or any appropriate material on vertical and horizontal surfaces complete all as specified and as directed by Engineer-in-charge
Providing and Applying rising damp proof coating system with single component ready to use damp proof coating Roff Hydamp 1. Preparation :- Throughly brush and clean all laitance, loose particles such as dirt, grease, mortar droppings, release agents, efflorescence, bird droppings, etc all large voids and hallow portions must be removed and re-plastered non moving cracks having width upto 5mm must be filled with polymer based crack filler. 2. Application :- Apply the first coat of Dr. fixit dampguard classic with a paint brush directly on the prepared surfaces by mixing (1 part base : 1 part hardner : 1 part of water), allow to dry for a minimum 2-3 hrs. apply one part of Dampguard mixed chemical and 2 parts of OPC white cement / Birla putty and make the putty, apply putty on the entire surface area, allow to dry for at least 3-4 hrs, apply the final coat of air cure 48 hrs proceeds for paints.
Demolition of reinforced cement concrete of any description and in any position not otherwise specificlly provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed by Engr-in-charge.
Formwork to faces of walls retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, butresses etc; vertical or to batter
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M&L for up rooting of tree from walls of bldgs up to extended root and spraying of acid of required quantity complete from any location of bldg up to 4 storied and making good distributed surfaces with cement mortar (1:4) or cement concrete type C1, 1:3:6 using 20mm graded stone aggregate including necessary scafolding complete for tree of girth up to 5 to 10 cm complete all as specified and directed by Engineer-in-charge.
M&L point wiring for one light point/ fan point controlled by one switch with 1.5 Sqmm (nominal cross section area) PVC insulated unsheathed multistranded copper conduct cable in and including medium grade rigid PVC concealed conduit in wall after cutting chases in wall including cast iron or pressed steel terminal box covered with and including 3 mm thick bakelite sheet top cover fixed flush with wall using brass screws, washers and 1.5 Sqmm single core PVC insulated unsheathed copper conductor wire as earth continuity to common earth and connecting to earth dolly and making good diturbed surfaces in cement motar 1:3 complete all as specified and directed.
,--ditto--- all as per Serial item No 77 above, but for One 3 pin 5 amps switch socket outlet point on same board with other switches complete all as specified and directed by Engr-in-Charge.
,--ditto--- all as per Serial item No 77 above, but for One 3 pin 5 amps switch socket outlet point on independent board complete all as specified and directed by Engr-in-Charge.
,---ditto-- all as per item No.77 above but point wiring with 4 sqmm multi stranded conductor cable and 4 sqmm unsheathed copper conductor earth wire for two in one 5 pin 15 Amp socket outlet on indep board.
Supply and fix switch, piano type, Single pole, one way 5 Amp rating 230/250 volts grade
Supply and fix switch, piano type, Single pole, one way 15 Amp rating 230/250 volts grade
Supply and fix socket out let multipurpose use, 3 pin 5 Amp with 2 Pin out let of 5 amp flush type 230/250 volts grade complete all as specified and as directed
Supply and fix socket out let multipurpose use, 3 pin 15 Amp with 3 Pin out let of 5 amp flush type 230/250 volts grade complet all as specified and as directed
Supply and fix ceiling rose surface, PVC/Poly Carbonate isolated body surface bakelite 65 x 50 mm three terminals complete all as specified and directed by Engr-in-charge.
S & F LED light fitting 1 x20 W, 230 V integral sleek polycarbonate LED channel with white acrylic cover incl making connection complete
Supply and fix lamp holder insulated body with back plate for angle/batten fitting with LED of 09 watt complete all as specified and as directed.
Supply & Fix exhaust fan, steel body AC single phase 230V of size 300 mm sweep with blades and frame and louvers all as specified and directed by Engineer-in-Charge
Supply and fix factory made, sheet distribution boards 4 way double door, protection class IP-30 suitable for mounting MCB/MCCB, confirm to IS - 13032, IS-8623, BS-5484 with min 200 Amps, copper bus bar, working on 240 V AC of the under mentioned type of all as specified
S & F MCBs 10 KA confirm to IS-8828 : 1996, IEC 898 : 1995 ruputing capacity of SP & N 32 Amp all as specified and directed by Engineer-in-Charge
S & F MCBs 10 KA confirm to IS-8828 : 1996, IEC 898 : 1995 ruputing capacity of SP 6-32 Amp all as specified and directed by Engineer-in-Charge
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel and wire mesh, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 10 cms above ground level. (ii) Outer edge of earth pit will be 1 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slanting position
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including bldg secuity light bracket made out of 25 mm dia GI medium grade pipe 0.6 mtr long complete with 2 sets of FI clamps made out of 30 x5 MS flat & nuts, bolts & washer including painting to clamp with two coats of aluminium silver paint over a coat of primer after complete all as specified and directed.
M & L sand cushioning with dry coarse sand to under ground cable 230 mm deep (80 mm below and 150 mm above the cable) complete all as specified and directed
M & L brick protection with sub class 'B' brick laid flat across the cable complete all as specified and directed
Supply and fix XLPE insulated armoured heavy duty electric cable with Aluminium conductor 1100 Volt grade 25 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
Dashmesh Construction Company
PAREEK AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .