Executive Engineer EDD LEH
Office of the Executive Engineer EDD Leh
Supply, Installation, Testing Commissioning for creation of Distribution Substations of various capacities 11 .415kV along with various locations of Spituk Phyang section of Leh District under SDP 2022 23 Ongoing.
2022_PDNRE_7091_1
eNIT NO. 54 of ED Leh of 2022-23 Dated 21.07.2022
Open Tender
Electrical Works
Turn-key
90 days
Leh
Please refer Tender documents.
6 documents required · 6 mandatory
₹3,500
Payable To Exceutive Engineer EDD Leh
Exempted
17 Sept 2022
21 Jul 2022
9 Aug 2022
22 Jul 2022
8 Aug 2022
22 Jul 2022
Amount
250 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or her kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
100 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or her kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
63 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or her kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
185mm²(2Ckt) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/63/100KVA & 250KVA DTs
120mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 100KVA DTs
70 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 63KVA DTs
9 Mtr. Long Pole,ST-410 SP33)
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
LT Distribution Box for 250kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 340 Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
LT Distribution Box for 100kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140 Amp (63/100/250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
LT Distribution Box for 63kVA DTR with TPN MCCB short ckt rating 16 KA for incomer and suitable MCCBs for outgoing circuits with terminal extensions
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stayrod& 7/3.15 mm dia GI stranded wire complete
Wedge Connectors / PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
11 KV HT metering CT & PT operated(complete set including cables etc)
3-Ø, 4-Wire Trivector Meter with CT(LTCT AMR compatible)
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like aluminium lugs, Jumpers, binding Tape,
11KV HT Line
9 Mtr. Long Pole,ST-410 SP33)
11 Mtr. Long Pole,ST-410 SP56)
GI V cross-arm with top Bracket including clamp as per specification(14.631Kg/complete V-set)
GI Channel X-arm including clamps and braces for DP (80Kg/DP)
30 mm² ACSR Conductor
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Aluminium Jointing Sleeves
Link Set
LT 3-Phase/1-Phase
8 Mtr. Long Pole( ST-410 SP15)
GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)
GI Channel X ARM (75X40X6mm) 2ft along with GI Clamp, 50x8mm, (2ft=4Kg, 1 No. clamp=0.83Kg = total weight = 4.83 kg)
30mm² ACSR Conductor
16kN Polymer Shackle Insulators
Galvinized Nuts and Bolts.
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
DRUK ELECTRICALS
M/S LOBZANG GURMET GOVT CONTRACTOR
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .