Er. Chander Shekhar
Office of the Executive Engineer, Electrical Division No. 3 Sector-4, Chandigarh.
MTC. OF EI IN NRB AT CHANDIGARH (REPLACEMENT OF EXISTING DEFUNCT LED STREET LIGHT, FLOOD LIGHT, TRACK LIGHT AND OTHER ALLIED ACCESSORIES IN RIBA STUDIO AT CHANDIGARH COLLEGE OF ARCHITECTURE, SECTOR-12, U.T., CHANDIGARH).
2026_CHD_95597_1
E3/47W/142
Open Tender
Electrical Works
Percentage
7 days
Chandigarh
as per NIT
2 documents required · 2 mandatory
₹0
₹7,200
18 Sept 2026
18 Sept 2026
24 Sept 2026
18 Sept 2026
24 Sept 2026
18 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1DSR item no.8.16 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt) Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg, suitable tilt able fitting, life time (LED, Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). | |||||
| 1.01 | 150 watt | 20 | Each | 3,457 | ₹69,140 |
| 2DSR item no.8.13 LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K(As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | |||||
| 2.01 | 45 watt | 18 | Each | 1,744 | ₹31,392 |
| 3Supply and Laying of PVC sheathed Aluminum flat of 4 mm² 2 core with the help of crane for steel tubular/ Octagonal pole. The wire should be of ISI marked. The job includes cost of dismantling, erection of existing fittings, bracket, making incoming and outgoing connection etc. other petty material required to complete the job to the entire satisfaction of Engineer-in-charge of the work. | |||||
| 3.01 | 9/10 mtr. Long Pole | 8 | Each | 700 | ₹5,600 |
| 4Supply and Erection of Cement Collar and Jn. Box at the base of the pole with the detailed specification as given below.: | |||||
| 4.01 | Jn. Box Construction: | - | - | - | - |
| 4.02 | Supply and fixing of OEM made Junction box IP 66/67 made out of Polycarbonate with Glass fiber reinforced of size 205 x 255 x 112 (mm) (minimum) with 5 nos. OEM made connectors/terminal blocks. The Jn. Box and connectors/terminal blocks should be supplies by OEM. The terminal blocks/connectors should be of Hensel/Wago/Elmax/Siemens make only and Junction box shall be of Hensel make KF-2525 G or its equivalent Clipsal/Legrand/Schneider/ABB make only. The junction box shall be fire retardant and self-extinguishing. The gasket materal shall be polyurethane and the gasket shall be internally embedded. The job includes all labour and petty material required to complete the job to the entire satisfaction of the Engineer in charge of work. | - | - | - | - |
| 4.03 | Cement Collar: | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 28.47 MB
BOQ_117424.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .