EE
Electrical Division No.II, HPPWD, U.S. Club, Shimla-01.
Providing addition alteration to record section in Principal office at IGMC Shimla. SH Providing E.I. therein.
2026_PWD_126471_3
ED.II.TA.TENDER.25.26.3183 dt. 21.01.2026
Open Tender
Electrical Works
Percentage
180 days
Shimla
Please refer to tender documents. Eligibility criteria is mentioned at page No. 9-10 of GCC. Documents mentioned in eligibility criteria must be uploaded to qualify the bid.
7 documents required · 7 mandatory
₹350
₹8,700
19 Mar 2026
24 Jan 2026
2 Feb 2026
24 Jan 2026
31 Jan 2026
24 Jan 2026
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 5 Amp Modular Plate And Switch and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.
Group C
supplying and fixing of suitable size GI box with modular plate and cover in front on surface/recess including providing and fixing 25 amps modular socket outlet Sp Mcb “C” curve including connections painting ect. As required.
supplying and fixing of suitable size GI box with modular plate and cover in front on surface/recess including providing and fixing 6 pin 5/6 amp &15/16 amp moduler socket and 15/16 amps modular switch connection As required
supplying and fixing following modular base 7 cover plate on existing modular mattal boxes ect. As required
8 module
supplying and fixing following modular switch & socketon the exising modular plate & switch box incuding connection but excluding modular plate ect. As required.
5/6 amps switch
3 pin 5/6 a socket outlet
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-supplying and fixing of suitable size GI box with modular plate and cover in front on surface/recess including providing and fixing
Single pole. Cat-A.
Supplying and fixing following rating following pole 10 KA breaking capacity, 240 -415V DB isolator suitable inductive load in the existing MCB connect,testing and commissioning ect. As required
Double pole. DP MCB 63 A Cat-A.
Supplying and fixing following rating following pole 10 KA breaking capacity, 240 -415V DB (4 poles) resdiule current circuit breaker (RCCB) having a sensitivity current 30ma in the existing MCB connect,testing and commissioning ect. As required ---- 63 Amp
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
Double door-16 way
Wiring for circuit/sub-main along with earth wire following size.HRFRLS/PVC insulated single core copper conductor cable surface/recessed steel conduit in medium class steel conduit as required 2 X 6sq mm + 1x 6 sq mm earth wire .
2x1.5 Sq. mm.
2x4.0 Sq. mm.
4x4 Sq. mm
Wiring for circuit/sub-main along with earth wire following size .HRFRLS/PVC insulated single core copper conductor cable surface/recessed medium class steel conduit as required.2X6 sq mm +1X6 Sq mm earth wire
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:-
Exhaust Fan, 300 mm sweep 1400/900 RPM
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion bolt with nuts and washers. Including embedding of expansion bolts in the wall , providing and fixing of Non-return valve. Dead weight safety valve, 2 no. C.P connections rods 18" long making good the damage , electrical connections , safety valves connection , testing and commissioning etc. as required:-
15 Liter capacity water heater (Cat-A)
S/E of LED Batten with polycarboante body and diffuser The fitting should be installed on existing surface/recess The job includes carriage, erection, making connections testing and commissioning of the fittings.
Specification of LED fittings:
Wattage of LED fittings - As per following parameter.
Total lumens of the fittings - as per wattage
Diffuser - Polycarbonate diffuser/PMMA
Operating voltage - 140 V to 270 V, AC supply or better.
Input frequency - 50 Hz + 1 Hz
Power factor - Minimum 0.90
Luminaire efficacy - ≥100 lm/w
Color rendering index - CRI shall be greater than 80
Working/ operating temperature - 00 to + 450c or better
Color temperature - 60000K + 10%
Electronic Driver
Drive current (LED) - As per OEM.
Operating voltage - 140 V to 270 V, AC supply or better.
Type of driver - Constant current output driver
THD - Less than 10%
Surge Protection - 2.5 KV minimum
Efficiency Driver - ≥85%
Protection - Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver - 2 years against manufacturing defect.
Fixture - Should comply with LM 79 test from UL/NABL lab.
LED Type/ Make/ Model - Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 25,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.
Life of LED - 25000 burning hours at 70% lumen maintenance
Lumen output of the fitting
LED Batten Light ≥2000Lumens.
S/E of LED Panel with PDC body and polycarbonate /Acrylic diffuser to be mounted in recess The job includes carriage, erection, making connections testing and commissioning of the fittings.2 * 2 feet
Specification of LED fittings:
Wattage of LED fittings - As per following parameter.
Total lumens of the fittings - as per wattage
Diffuser - polycarbonate/acyrlic diffuser UGR <30
Operating voltage - 140 V to 270 V, AC supply or better.
Input frequency - 50 Hz + 1 Hz
Power factor - Minimum 0.90
Luminaire efficacy - ≥110 lm/w
Color rendering index - CRI shall be greater than 80
Working/ operating temperature - 00 to + 450c or better
Color temperature - 60000K + 10%
Electronic Driver
Drive current (LED) - As per OEM.
Operating voltage - 140 V to 270 V, AC supply or better.
Type of driver - Constant current output driver
THD - Less than 10%
Surge Protection - 2.5 KV minimum
Efficiency Driver - ≥85%
Protection - Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver - 2 years against manufacturing defect.
Fixture - Should comply with LM 79 test from UL/NABL lab.
LED Type/ Make/ Model - Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.
Life of LED - 50000 burning hours at 70% lumen maintenance
Lumen output of the fitting
LED Panel Light 2'x2' ≥3300Lumens.
Armouured cable 95 sq mm (3.5 core)
Armouured cable 25 sq mm (3.5 core)
Armouured cable 16 sq mm (2 core)
S/E of MCCB 4 Pole with Thermal magnetic Realese for overload and short circuit protection breaking capacity (lcs= 100 % lcu with positive isolation) with/ without Spreader/rotary handle
40-100 Amps 36 KA release without rotary handle
supplying and fixing TP &N copper bus bar chamber suitable for 415 V capacity with 4 No. copper strip bus bars each of length and X- section suitable for following current carrying capacities enclosure made of sheet steel having thickness of 1.6 mm dust protectd . Dully power painted with detachable gland plate and other accessories including drilling hole on the board making connections earthing etc.. As required.
100 amp copper bus bar chamber 15” (SS En closer )
Supply, installation, testing and commissioning of 6-way Double Door TPN Phase-Segregated Distribution Box (recessed type), conforming to IS 8623 / IEC 61439, made of sheet steel with double door, suitable for mounting MCCB incomer (4-module) and 4 outgoing SP MCCBs in each phase (total 6+6+6 outgoing), complete with insulated busbar interconnections and duly powder coated including all necessary treatments, as required. Make: L&T / Schneider / ABB / Legrand or equivalent.
Supply, Installation, Testing & Commissioning of Distribution Panel (as per specifications), comprising:
MCCB 320A–400A, 3P, 36 kA, TMR with O/L & S/C protection (lcs= 100 % lcu with positive isolation) – Qty: 1
digital Metering set-(Detail Below )
Amp Meter 96 X96 Mm---------1
volt Meter 96 X 96 mm ----------1
Current transformer 600/5 Amp-----3
Phase Indicator Lamp, LED Type (Red & Yellow) – Qty: 3
Control SP MCB,---------------------- Qty: 3
Terminal strips-------------1
CT Shorting link-----------4
Out Going ----------------------------------------------1
Bus Bar ----------------------------------------------1
Fabricationcubical type, indoor, single-door, floor mounting or wall mounting, fixed type, free-standing, single front, dust-proof, and compartmentalized. Fabricated out of M.S. CRC sheet of 16 SWG, powder-coated with Siemens Grey paint as per specifications and drawings.
Assembly of 300 A TPN aluminum, arranged horizontally/vertically with earth strips throughout the length of the panel. Current density of aluminum busbar shall be 1 mm x 1 mm = 1.0 Amp. Aluminum shall be electric grade E-91E, supported by DMC epoxy insulators. Busbar links shall be insulated with heat shrinkable sleeves, color coded Red, Yellow, Blue, Black.
Assembly of Ialuminum solid / copper flexible wire from busbar to MCCB and MCCB to outgoing field terminals. All interconnections duly insulated with color coded heat shrinkable sleeves (Red, Yellow, Blue, Black). Field side interconnections supported by conical T & finger type insulators of adequate size to support and sustain the weight of cables.
Control wiring in 2.5 sq.mm copper flexible wire for control circuits, complete as required. Panel shall include all necessary accessories such as gasket, door lock, copper flexible door earth, legend plates, etc.
assembly charges of accessories Like gasket door locks copper flaxiable door earth Legend plates ect
Providing and fixing of 6 SWG GI wire on surface or in recess for loop earthing as required
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_186502.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.75 MB
GCC.pdf
Tender Documents • 5.02 MB
BOQ_186502.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .