| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.4 CrAdmitted-Finance | -2.70% | ₹2.4 Cr | L1 | Admitted-Finance |
Tender Value
₹2.6 Cr
EMD Value
₹5.3 L
Closing Date
30 Jul 2025, 6:00 pmClosed
Executive Engineer M and H, Dn. Sikar
Executive Engineer M and H, Dn. Sikar
SITC of HVAC Work in the construction of Sub District Hospital Malsisar, Distt. Jhunjhunu.
2025_MEDIC_488375_1
NIT No.08/2025-26 EE Medical and Health Sikar/
Open Tender
Civil Works
Percentage
300 days
Jhunjhunu
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,000
RTGS/NEFT/Any other money Transfer System
₹5.3 L
9 Oct 2025
17 Jul 2025
31 Jul 2025
17 Jul 2025
30 Jul 2025
17 Jul 2025
Amount
NON BSR ITEM
AIR HANDLING UNITS FOR OT VRV SYSTEM
Supply,installation, testing and commissioning of factory fabricated Double Skinned DX Coil Air- handling unit fabricated out of extruded aluminium section with 0.8mm pre-plasticized /pre-coated Galvanised steel sheet outside & 0.8 mm polished GI sheet inside complete with supply blower section with single / multiple AMCA certified backward curved plug fan with aerofoil design blades, power control panel with necessary switchgears incoming & outgoing for VFD, blower suitable for static pressure as required (Fan Static given below is for guideline), blower motor TEFC (IE3) type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 6 row cooling coil made of Aluminium finned Copper tube, Copper header with coil section, pre-filter section with non woven synthetic media MERV 8 filters in extruded aluminium frame in both the supply & exhaust side of AHU, fine filter section with MERV 13 filters in extruded aluminium frame in supply after fan, (Hepa filters shall be at terminals along with laminar flow plenum & not to be included in the cost),. The capacity of Air-handlers shall be as follows:
3200 CFM (8.0 TR ) ESP - 120 mm
2400 CFM (6.0 TR ) ESP - 120 mm
Fresh & Exhaust air in line fan: - Supply, installation, testing and commissioning of Exhaust &fresh air inline fan.
400CFM (static pressure upto 20 mm)
800 CFM (static pressure upto 20 mm)
900 CFM (static pressure upto 20 mm)
1000 CFM (static pressure upto 20 mm)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ.xls
BOQ • 0.47 MB
Tenderdocument.pdf
Tender Documents • 0.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .