Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹36,639Admitted-Finance NO 1 4773 STREET NO 09 SHAHDARA EAST DELHI DELHI 110032 | SHAHDARA | DELHI | 110032 | L1 | Admitted-Finance | ||
| 2 | L1₹36,639Admitted-Finance 368 369 2ND FLOOR BASANT BUILDING CHAUDHARY MARKET SULTANPUR SOUTH WEST DELHI DELHI 110030 | SOUTH DELHI | DELHI | 110030 | L1 | Admitted-Finance | ||
| 3 | Rejected-Technical E 43 NAWADA HOUSING COMPLEX NEAR PILLER NO 792 DWARKA MOR UTTAM NAGAR NEW DELHI WEST DELHI DELHI 110059 | WEST DELHI | DELHI | 110059 | - | Rejected-Technical disqualified |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
6 Jan 2026, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Mand H D Srinagar
Executive Engineer Mand H D Srinagar
Annual Rate Contract for MGPS works at GMC and associated hospitals for the year 2025 26
2025_PWDJK_299236_1
MHDS/TS /2025-26/123/e-tendering dt 27.12.2025
Open Tender
Repair and Maintenance Works
Percentage
365 days
GMC SRINAGAR
as per nit
4 documents required · 4 mandatory
₹500
Executive Engineer MHD Srinagar
₹18,000
7 Feb 2026
27 Dec 2025
6 Jan 2026
27 Dec 2025
6 Jan 2026
27 Dec 2025
Providing,Fitting and Testing of Gas outlet/inlet points/Double Lock Outlets including respective adaptors for [O2,Co2 ,N2O, Medical Air and Vacuum] which shall be of HTM 0201 BS standard, manufactured with a 165 mm length, Copper inlet pipe stub which is silver brazed to the outlet body. Body shall be of one piece brass construction. For positive pressure gas services, the outlet shall be equipped with a primary and secondary check valve and the secondary check valve shall have break safe mechanism and also comply to EN 737 pressure test standards and rated at minimum 200 psi in the event the primary check valve is removed for maintenance. The outlet assembly should have separate colour coding for each services and will accept only corresponding gas specific adaptors. All outlets shall be cleaned and de-greased for medical gas service, factory assembled and tested and to be fitted inside existing Pendents & Bed Head pannels as a replacement against Damaged Ones .
Providing,Fitting and Testing of Back Pressure Compensated [BPC] flow meter with Humidifier bottle having control within a range of 0 – 15 lpm (calibration within +/- 10%).It should meet strict precision and durability standard.The flow tube and shroud components should be made of clear, impact resistant polycarbonate and humidifier bottle shall be made of unbreakable polycarbonate material and to be fitted inside existing Pendents & Bed Head pannels as a replacement against Damaged Ones
Providing, Fitting and Testing of 600 ml Ward Vacuum Unit. The unit should consist of a regulator, reusable collection jar made of unbreakable poly carbonate material and fully autoclavable at 134 degree centigrade, a wall bracket for mounting the jar assembly on the wall.The vacuum regulator shall be adjustable and have vacuum gauge which indicates suction supplied by the regulator. Safety trap shall be provided inside the jar to safeguard the regulator from overflowing and to be fitted inside existing Pendents & Bed Head pannels as a replacement against Damaged Ones .
Providing, Fitting and Testing of 2000 ml Theatre Vacuum Unit. The unit should consist of a regulator, reusable collection jar made of unbreakable poly carbonate material and fully autoclaveable at 134 degree centigrade, a wall bracket for mounting the jar assembly on the wall.The vacuum regulator shall be adjustable and have vacuum gauge which indicates suction supplied by the regulator. Safety trap shall be provided inside the jar to safeguard the regulator from overflowing.
Providing,Fitting and Testing of below sized distribution piping and terminal units as a replacement against Damaged ones for oxygen, vacuum, C02,N02 and compressed air drawn from Solid , seamless, de-oxidized, non-arsenical, half-hard, tempered and de-greased copper pipe conforming to EN 13348: 2008. All copper pipes should be de-greased & delivered capped at both ends.Copper fittings shall be made of copper and suitable for a steam working Pressure of 17 bar and especially made for brazed socket type connections. All copper fittings fabricateds from same pipe should be conforming to EN 1254-1, should be factory de-greased, certified, and individually packed and identified for medical use. Fittings should be kite marked up to 42 mm size.
Providing ,fitting and Testing of below sized Isolation valves.The isolation valves should be Non-Lubricated, 90 (degree) turn level, Ball type, suitable for Gaseous service.All valves shall be pneumatically tested for twice the working pressure and factory degreased for medical gas service before supply.
Providing and fitting of Probes for Oxygen, Vacuum, Medical air and No2 (as per sample)
Providing and fitting of probes for ventilators( as per sample)
stage.html
html • 0.03 MB
techsummary_970779.pdf
finance_970779.pdf
BOQ Comparative Chart
xlsx
cancelled_1.pdf
pdf • 0.44 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
Tendernotice_2.pdf
PDF • 0.50 MB
BOQ_970779.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .