| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.9 LAccepted-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹42.3 L+₹1.1 L (2.59%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 3 | L3₹44.5 L+₹3.3 L (7.93%)Rejected-Finance | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 4 | L4₹47.0 L+₹5.8 L (14.0%)Rejected-Finance NO 92 KUVEMPUNAGAR 2ND STAGE JALAHALLI EAST BANGALORE 560 014 | 560014 | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹96,800
Closing Date
19 Dec 2023, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
SPECIAL REPAIRS TO FLOORING AND RAT PROOFING OF CERTAIN STORES SPECIAL REPAIR OF STREET LIGHTS AND PROVN OF PATH LIGHTS NEAR LOGISTIC SECTION AT AFS JALAHALLI
2023_MES_624369_1
8831/E8
Open Tender
Electrical and Maintenance Works
Item Rate
151 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF MAINT JALAHALLI PUBLIC FUND ACCOUNT
₹96,800
5 Jan 2024
21 Nov 2023
21 Dec 2023
21 Nov 2023
19 Dec 2023
5 Dec 2023
21 Nov 2023 - 28 Nov 2023
Amount
Demolition of Concrete (reinforced) of any description and in any position not otherwise specifically provided for and Material and labour for Reinforced cement concrete nominal mix in chajjas TypeB0 1:2:4, 12.5mm concrete all as specified and directed.
Use and waste form work for RCC flat surface chajjas with rough finish all as specified
Material and labour Mild steel bars TMT 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including inserting (0.2m ) to old structures and mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Material and labour for Complete removal of existing treatment, using mechanical sander with internal dust extraction system ,preparation of old surfaces for further coat on walls and Material and labour for priming the surfaces with Chalk whiting,incl one coat of 3mm putty on old plastered surfaces, prepara-tory to distempering and Material and labour for preparation of primed surfaces of wall, Distempering in two coats with 1st quality OBD of required shade and colour complete, as per manufacturer's specification all as specified
Material and labour for preparation of old surfaces of steel and iron work of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint on old surfaces in any tint complete all as specified.
Material and labour for preparation of old surfaces of wood work of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint on old surfaces in any tint complete all as specified. Note for item No 04 & 05:- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified. (b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works. (c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint will be approved by the GE. (d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite) (e) Unless otherwise specified the tints of paint shall be as approved by the GE (f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval. (g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge. (h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
Taking down cement plaster of any description on brick or stone walls/ceiling etc. incl racking out joints, hacking for key, scrubbing down with water, etc. and removal of the debris all as specified and directed.
Material and labour pre-cast PCC 1:3:6 type C1 (20 mm graded agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:6 including demolition of Brickwork or stone/ boulder masonry, laid dry or with mortar and all as specified .
Material and labour for rendering 15 mm thick in CM 1:6 on fair faces of brick work/stone masonry finished even and smooth without using extra cement and Material and labour for preparation of new wall apply 3 coats of white wash all as specified
Material and labour for Rendering 15mm thick in CM 1:6 on stone masonry wall surfaces to finish even and rough and Material and labour for preparation of new surfaces of wall and applying two coats of obd with one coat of primer with chalk whiting and Taking down cement plaster of any description on brick or stone walls etc. incl racking out joints, hacking for key, scrubbing down with water, etc. and removal of the debris and all as specified and directed.
Material and labour for 20-25mm thick Machine cut kota stone slab greenish colour flooring , rubbing and polishing over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including and over 25 mm thick PCC (1:2:4 ) type B1 using 20 mm graded stone agg as in sub base of floor levelling the existing floor and over Screed bed or bedding layer of mortar 20 mm thick in CM (1:4) for laying floor finishes and including demolition of old / existing concrete in ground floor approximately 40 mm thick not otherwise specifically provided and including and removal of the debris all as specified and directed.
Material and labour for Joint free Non - skid dark Coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. , Brushing neat cement slurry with 3.0kg of cement per sq. metre including Screed bed or bedding layer of mortar 15 mm thick in CM (1:4) for laying floor finishes and all as specified and directed.
Material and labour for Joint free Non - skid dark Coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including Rendering 15mm thick in CM 1:3 on block/ stone masonry surfaces to finish even and rough to receive wall tiles/stones and necessary taking down all as specified.
Material and labour for Rendering 10mm thick in CM 1:4 on stone masonry ceiling surfaces to finish even and rough and Material and labour for preparation of new surfaces of ceiling including brooming down, scrapping down smoke soot, efflorescent salts, trading oil, greasy spots etc and applying three coat of white wash and taking down cement plaster of any description on brick or stone ceiling etc incl racking out joints, hacking for key, scrubbing down with water, etc. and removal of the debris and all as specified and directed.
Material and labour for preparation of old surfaces of CEILING including scrapping down, smoke soot, efflorescence salts trading oil and greasy spots etc by applying one coat of white wash on walls
Material and labour for Machine cut kota stone slab greenish colour flooring 20-25mm thick over cement screed base laid / Screed bed or bedding layer of mortar 20 mm thick in CM (1:4), Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and Brushing neat cement slurry with 3.0kg of cement per sq. metre for laying floor finishes and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing all as specified and directed.
Material and labour for stainless steel curtain rods of 1 inch diameter rod fancy type with required holding clips and brackets with wooden gutta all as specified.
Supply and fixing sheet glass ordinary quality 3 mm thick, in squares n.exc. 0.50 Sqm in each pane including necessary new oil putty or with existing metal beadings including hacking out old broken glass panes from metal frame including punching and drilling out and glazing pins/spring clip and complete.
Material and labour for Taking down of Shutters, adjusting, cutting edges and refixing in same openings of area exc 1 sq. m and n exc 2 sq. m each incl hinges all as specified
Material and labour for Taking down of Shutters, adjusting, cutting edges and refixing in same openings of area nexc 1 sq. m each incl hinges all as specified
Material and labour for machine cut Kota stone slab greenish colour 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed grey cement slurry mixed with pigment to match the shade of the slab and including rubbing, polishing and Rendering 10mm thick in CM 1:3 on block/ stone masonry surfaces to finish even and rough to receive wall tiles/stones and complete incl necessary taking down of tiles etc all as specified.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables for foundation and laying of cable/erecting poles up to proper level complete all as specified and directed by Engr-in-charge.
Returning and filling in soil including spreading levelling watering and well ramming in layers not exceeding 25cm all as specified.
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983 and as directed. Note :- Excavated approved soil shall be ribbed by using sieve to separate composite particles etc as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is than gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness only will be considered for payment.
Material and labour for well burnt as class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench complete all as specified and directed by Engr-in-charge.
Removing surplus excavated material from excavation not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point complete all as specified and directed by Engr-in-charge.
Supply, Laying and testing XLPE UG cable 10 sqmm cross sectional area and 4 core PVC insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade in trenches including taking up defective unserviceable cable all as specified and directed.
Supply & Erecting in replacement of Mild steel tubular swaged poles of 9.0 meter long 410, SP-31 complete with cast iron base plate, bracket, final taper plug, bolt, nuts & screws and painted on both side (internally & externally), external surface painted with two coat of aluminium paint over coat of red oxide primer and painting with black up to 1.5 meter from top of PCC coping white colour paint as in strips of equal width including marking pole numbers with one coat of synthetic enamel paint complete all as specified and as directed including dismantling of U/S steel tubular swaged poles of 9 mtrs height including setting aside and transporting to stores as directed.(Excavation and earth will be measured and paid separately)..
Material and Labour for plain cement concrete type D2 1:4:8 using 40mm graded stone aggregate for foundation of poles etc, all as specified.
Material and Labour for plain cement concrete type C1 1:3:6 using 20mm graded stone aggregate for coping for poles including necessary form work to exposed surfaces finished smooth and even all as specified.
Supply and fix in repair bracket for street light fitting made out of 40 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers and fixing to the pole complete including taking down old or Old U/S bracket from the pole as directed.
Taking down unserviceable street light HPSV / MH/Tube light fitting fitting of any wattage and type from the pole/building of any height including disconnecting the cable connections complete all as specified and directed.
Supply and fix in repair of LED street light 25 Watt fitting, environmental friendly long life, made up of pressure die cast aluminium housing with mid power LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. Make:- Philips/ Bajaj/CG
Supply and fix in repair of LED street light 30 Watt fitting, environmental friendly long life, made up of pressure die cast aluminium housing with mid power LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. Make:- Philips/ Bajaj/CG
Supply and fix in replacement weather proof PVC junction box approved by CPRI street light control box made out of not less than 2mm thick of size 250mm x 200 mm x 105mm (approx.) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No panel mounted connector 4 pole MCB 6A 10KA 01No, including connecting up with the electrical connections and fixing and clamping complete and all as directed.
Supply and fix in replacement for wiring to suitable street light fitting connection tapping from the line / connecting up from the junction box to the fitting etc. with1.5 sqmm multistranded PVC insulated copper conductor including taking old cable all as directed. Note:-Two run of cable copper conductor and non metallic PVC Rigid/ flexiable conduit(20mm dia) shall be measured as one unit length.
Supply, install testing and commissioning of LT out door type totally enclosed dust and vermin proof floor mounting with hinged doors and locking arrangement front and back fabricated out of 3.15 mm thick CRCA sheet including powder coated paint finish including all accessories, provision independent removable MS plates for fixing cable glands for all suitable for 10sqmm X2 core UG cable incoming and out going cables and complete control wiring with 2.5 sum copper conductor including necessary PCC foundation complete all specified and directed by Engineer-in-Charge. Note :- (1) Rates deemed to be included for suitable lugs and glands for incoming and out going of LT UG cable. (2) The Contractor Shall submit the drawing with sample of accessories for approval before executing the work. INCOMING :- MCCB 100 Amp 4 pole,25KA -01 OUTGOING:- DIN rail arrangement FOR MCB, (i) MCB 40 Amp TP,10KA -04 Nos and (ii) MCB 32 AMP DP,10KA-04 Nos
Supply and fixing Round spherical garden lighting, post top lantern having b22 holder suitable for LED bulb 10 watt, 220 volt,50HZ,IP>65 including suitable of GI tubing ,length as per site requirement of on gate pillars/ garden lights for fixing the lamp, wiring with 1.5 sqmm PVC insulated stranded copper conductor including PCC work for fixing of light fitting complete all as specified and directed.
Supply and fixing LED post top lantern fitting 25 watts on existing pipe of any size and height with all accessories prewired fixed with FI clamps nuts bolts etc. complete all as specified and directed (Make :Havells Cat No RUBYPT25WLED830SSYMTOPC or equivalent in CG/Wipro/bajaj.
Material and labour cutting the road hard standing & making good surface with PCC 1:3:6 C-1 Type Using 40 mm graded stone aggregate & removing the to distance n.exe 50mtr all as specified.
Supply and fix in replacement for GI pipe light grade 40 mm dia for cable protection on road crossings /plinth protection with fixed to the pole wall etc along with suitable fittings for cable protection all as specified and directed..
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core all as specified and directed.
Supply and fixing energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting of 70 watt.Make:Cat No JETAALBAFLOODLIGHT70Wof Havel's/Philips/Wipro
.Supply and fix in repair of LED street light 45 Watt fitting, environmental friendly long life, made up of pressure die cast aluminium housing with mid power LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. Make:- Philips/ Bajaj/CG
Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having 12 KW 3 phase 32 amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor. Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 lux and for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS. Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity. The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal whether proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 type B1 for grouting of base including taking down unserviceable panel. The scope of work also comprising the following :- The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity.The panel should have three operation mode :-1. GSM mode -in this mode light should be switched as per GSM controller's preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switches as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The Gsm controller should also compatible for cloud based data transmission for interfacing with web for future use, Password protection for Accessing the control of device via SMS/IVRS complete all as specified and directed including the following subcomponents & features :-
(a) MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, BCH, Havells) (b) Supply Resign cast CT'S - set of 3 (c) Gsm based smart street light controller. (d) Lux based sensor to operate external as per light intensity. (e) Line Contactor, AC 3 duty, 3 phase, 415 volts. 50 Hz , 25 Amps -03 Nos (make - L & T, BCH, Havells) (f) MCB SP 32 Amps- 03 Nos (make -L & T, BCH, Havells) (g) Terminal block suitable for 100 A rating with brass contacts for INPUT/ and 63 A for OUTPUT termination. (h) GSM/Timer/Bypass Mode switch. (j) Panel wiring for control circuit with copper flexible 1.5 sqmm & power wiring 10 sqmm flexible. Make- Tricolite/ Kewintech/HPL
Supply and fix in repair of LED street light 70 Watt fitting, environmental friendly long life, made up of pressure die cast aluminium housing with mid power LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. Make:- Philips/ Bajaj/CG
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India along with 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one all as directed. Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO.
The quoted rate is deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end ( copper strip will be measured and paid separately).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concern.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall given a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xv) The connection clamp shall be permanently welded to the copper bounded rod to avoid any kind of connectivity loss,. The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) The contractor shall submit CPRI India certified doCument for copper bonded rod to ensure genuity of material.
(xviii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
(xix) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
Material and labour for Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete including taking down all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electro grip Model/ EGTEK3LC of ISG Global or equivalent in OBO Betterman/ ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
M/S SRI BALAJI ENTERPRISES
Forge Engineering & Electricals
BYRAVESHWARA CONSTUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .