| 1 | L1₹69.8 LAccepted-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-Finance Lowest One | |
| 2 | L2₹85.0 L+₹15.2 L (21.8%)Rejected-Finance 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | L2 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
26 Jun 2023, 6:00 pmClosed
GE NW NOFRA
Dr Homi Bhabha Road New Navy Nagar Colaba Mumbai
REPAIR REPLACEMENT OF LT PANEL LT CABLES, REPAIRS TO CAPACITORS CALIBRATION FILTRATION OF HT LT EQPT AND MAINT OF DG SETS AND REPAIR MAINT OF PUMP MOTORS WATER PIPE LINE AND CLEANING OF UG OH SUMPS IN OUTLAYING AREA UNDER GE NW NOFRA
2023_MES_595965_1
8177
Open Tender
Civil Works
Item Rate
330 days
Mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹1,000
GE NW NOFRA
₹1.7 L
Yes
17 Oct 2023
17 May 2023
28 Jun 2023
17 May 2023
26 Jun 2023
7 Jun 2023
17 May 2023 - 31 May 2023
Amount
Material and labour for loading into truck of faulty Transformer of capacity 200 KVA to 750 KVA with the help of Crain and shifting from site to factory premises and unloading complete all as specified and directed.
Material and labour for loading into truck of Transformer capacity 200KVA to 500KVA after carying out the repair with the help of Crain and shifting from factory premises to site and unloading and shifting it inside the sub station and connecting all HT and LT cable connections and earthing connections complete all as specified and directed.
Material and labour for Dismantling the Core and taking out along with windings and cleaning oil tank of transformer 250 to 500KVA, 11KV/415Volts and removing sludges from tank, manufacturers specifications and standard practice complete all as specified and directed. (Note: Transformer Oil will be measured and paid seperately).
Material and Labour for Dismantling the faulty HV winding carefully from transformer of any type and capacity11KV/433Volts from core and rewinding the HV winding with suitable size of insulated copper wire as per manufacturers specifications and standard practice complete all as specified and directed.
Material and Labour for Dismantling the faulty LV winding carefully from transformer of any type and capacity,11KV/433Volts from core and re winding the LV winding with suitable size of insulated copper wire and as per manufacturers specifications and standard practice complete all as specified and directed.
Material and labour for reinsulating the HV winding with DPC insulation and as per manufacturers specifications and standard practice complete all as specified and directed.
Material and labour for reinsulating the LV winding with DPC insulation and as per manufacturers specifications and standard practice complete all as specified and directed.
Material and labour for refixing the core and windings assembly with insulating material and hardware of Transformer of any capacity and type,11KV/433Volts in to the oil tank with suitable fixing arrangements and re connecting HV and LV internal connections to HV and LV bushings and replacing gaskets of bushings,bottom and top valve, top cover, conservator and replacing celica gel breather and fixing top cover with conservators and reassembling all parts respect to original position and refilling of new transformer oil and filler to achieve the BDV Values and testing as per manufacturers specifications and standard practice complete all as specified and directed. (Note: transformer oil will be measured & paid seperately)
Dismantling of old damaged Lamps and Supply & fixing in repairs indicating lamp holder with bulb LED(Red Yellow,Blue,Green) type to indicate incoming supply suitable for 24 V DC/110 VAC/230Volts AC and all as specified and directed. Make:Teknic/ C&S /L&T
Dismantling of old damaged/burnt ACB with Bus Bar and Supply , fixing , ELECTRIC MOTORISED including all accessories as per site reqirement , testing and commissionning in repair in existing panel ACB. 4Pole, 630 Amps ,MDO , 36KA suitable for 415V, 3phase, AC supply including necessary modification in panel with 2mm thick CRCA sheet door and suitable size of Copper bus bar and all specified and directed. Make : Schneider/L&T/Havells/ Legrand.
Dismantlin the old damaged Relay and Supply only APFC Relay, 12Stages digital type suitable for 415V, 3phase, AC supply and all specified and directed. Make - L&T/ Syntron/Sycon
Dismantling the Old damaged Capacitor Bank and Supply and fixing Capacitor bank 5KVAR, Heavy duty type,415Volts,50Hz AC supply in existing panel complete as specified and directed by Engr-in-charge. (make: Prabodhan/Epcos/Havells/Schnieder
Ditto all as per item No.14 but of rating 10KVAR
Ditto all as per item No.14 but of rating 15KVAR
Ditto all as per item No.14 but of rating 20KVAR
Ditto all as per item No.14 but of rating 25KVAR
Dismantling of Old Damaged Contactor and Supply only Power contactors Capacitor Duty(Type MOC of L&T) 50Amps Capacitor duty with 2NO+2NC suitable for ,415Volts,50Hz AC supply in existing panel complete all as specified and directed by Engr-in-charge Make : L&T/C&S/Schnieder
Ditto all as per item No.19 but rating 40Amps
Ditto all as per item No.19 but rating 32Amps
Dismantling of old damaged MCB and Supply and fixing in repair of MCB,TP,C'Curve,63 Amps,415Volts,50Hz AC supply in existing panel with mounting rail complete all as specified and directed by Engr-in-charge.
Ditto all as per item No.22 but rating 40Amps
Ditto all as per item No.22 but rating 32Amps
Ditto all as per item No.22 but rating 20Amps
Dismantling of Old Damaged Contactor and Supply and fixing Auxilaury contactors 10Amps Capacitor duty with 8NO+8NC suitable for ,415Volts,50Hz AC supply in existing panel complete all as specified and directed by Engr-in-charge Make : L&T/C&S/Schnieder/Havells
Dismantling of Old Damaged timer and Supply and fixing Time delay Timer suitable for APFC panel ,415Volts,50Hz AC supply in existing panel complete all as specified and directed by Engr-in-charge Make : L&T/C&S/Schnieder/Havells
Dismantling of Old Damaged CT and Supply and fixing Current Transformers,415V 600/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel and all as specified and directed. Make : AE/NSDA/MECO/C&S
Dismantling of Old Damaged CT and Supply and fixing Current Transformers,415V 400/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel and all as specified and directed. Make : Make : AE/NSDA/MECO/C&S
Dismantling of Old Damaged CT and Supply and fixing Current Transformers,415V 200/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel and all as specified and directed. Make : AE/NSDA/MECO/C&S
Material and labour for fault finding & route locator of HT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge.
Material & labour for HT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT for 11KV gradecomplete with Jointing material (Heat shrinkable)and accessories suitable for 3 core XLPE armoured, alluminum conductor cable of size 120 to 240 sq mm and all as directed by Engineer-In-Charge.
Material & labour for HT Cable Jointing work by Cutting the faulty cable and making END TERMINATION JOINT for 11KV grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3 core XLPE armoured, alluminum conductor cable of size 90 to 185 sq mm and all as directed by Engineer-In-Charge.
Supply and laying HT cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)11000 Volts grade with stranded aluminium conductor of size 185 Sqmm 3 core and all as directed by Engineer-In-Charge.Make: Polycab/Havells/Nicco/Gloster
Supply and laying LT cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)11000 Volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 core and all as directed by Engineer-In-Charge.Make: Polycab/Havells
Material and labour for fault finding on LT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge.
Material labour for LT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 16 to 25 sq mm and all as directed by Engineer-In-Charge. Make: MSeal/Raychem/Densin
Material labour for LT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 35 to 50 sq mm and all as directed by Engineer-In-Charge.
Material labour for LT Cable Jointing work by Cutting the faulty cable and making new STRAIGHT THROUGH JOINT for 1100V grade cable complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 70 to 185 sq mm and all as directed by Engineer-In-Charge.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 150Sqmm 3.5 core and all as directed by Engineer-In-Charge. Make: Polycab/Havells/Nicco/Gloster
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 120Sqmm 3.5 core and all as directed by Engineer-In-Charge. Make: Polycab/Havells
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 95Sqmm 3.5 core and all as directed by Engineer-In-Charge. Make: Polycab/Havells
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 70Sqmm 3.5 core and all as directed by Engineer-In-Charge. Make: Polycab/Havells
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 50Sqmm 3.5 core and all as directed by Engineer-In-Charge. Make: Polycab/Havells
Material & labour for chequered plate 5 mm thick size as per site requirement including cutting to required shape and appling two coat of synthetic enamel paint over a coat of red oxide primer and all as directed
Material and labour for fixing angle Iron of size 25x25x6mm size and square bar applying two coats of synthetic enamel paint over a coat of red oxide primer and all as directed
Material and Labour for Attending Faults/Trippings and rectifieng /repairing the faults in LT Panels Boards/Capacitor Panels Boaeds/ MCCB's/ACB's /Change Over switches/Cable Connections/Bus Bar etc including PVC insulating Tapes/Nut bolts and all as specified and directed by Engineer-In-Charge. Note : Damaged/Burnt MCCB/ACB'S/Changeover switc/Lugs.will be measured and paid separately)
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole, 400 Amps, 25kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,315 Amps,35kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,250 Amps,25kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,160 Amps,25kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt Change Over Switch and Supply & fixing of Change Over Switch ,4Pole, 315 Amps, Open Execution,ON LOAD type 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt Change Over Switch and Supply & fixing of Change Over Switch ,4Pole, 250 Amps, Open Execution,ON LOAD type 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs and Supply & fixing set of Aluminum Lugs with PVC Insulation Tape of size 300Sqmm to 240Sqmm complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs from brunt cable /MCCB/Panel bus bar and Supply & fixing set of Aluminum Lugs with PVC Insulation Tape of size 185Sqmm to 150Sqmm -240Sqmm complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs from brunt cable /MCCB/Panel bus barand Supply & fixing set of Aluminum Lugs with PVC Insulation Tape of size 120Sqmm to 95Sqm complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs from brunt cable /MCCB/Panel bus bar and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 70Sqmm to 50Sqmm complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs from brunt cable /MCCB/Panel bus bar and Supply & fixing set of Aluminum Lugs with PVC Insulation Tape of size 35Sqmm to 16Sqmm complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs from brunt cable /MCCB/Panel bus bar and Supply & fixing set of Aluminum Lugs with PVC Insulation Tape of size 10Sqmm to 4Sqmm complete all as specified and directed by Engr-in-charge.
Material and Labour for Attending Faults/Trippings and rectifieng /repairing the faults in HT Panels Boards/Cable Connections including HT insulating Tapes/Nut bolts and all as specified and directed by Engineer-In-Charge. Note : Spare Parts.will be measured and paid separately)
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth in hard/dense soil for laying of cable/ GI pipe and getting out complete all as specified and directed.
Returning, filling in including spreading levelling watering well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing surplus soil to a distance outside MoD land and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cutting metal road/hard standing for laying of cable and re metaling/making good the same to match the existing surface complete all as directed by Engr incharge.
S&F HDPE of pressure rating 6kg/cm sq pipe of 90 mm dia including necessary bends, elbows, Tees etc on cable protection complete all as specified and directed by Engineer-in-Charge. Make : Make : Suprime /Prince or equivalent approved by GE
S&F HDPE of pressure rating 6kg/cm sq pipe of 63 mm dia including necessary bends, elbows, Tees etc on cable protection complete all as specified and directed by Engineer-in-Charge. Make : Suprime /Prince or equivalent approved by GE
Servicing of diesel engine of 125 KVA at INS Shikrs Power house,repair/replacement of the following components including opening engine and replacing all gaskets complete all as specified and directed by Engr-in -charge
(a) Cylinder head gasket to be repaire
(b) Element LO filter with O ring 1 set.
(c) Element fuel filter with O ring -1set
(d) Filter screen - 2 set
(e) Element air cleaner 1 No
(f) Element Bypass filter with O ring 1 No.
(g) All fuel,oil,and coolent and head need to be changed.
(h) Checking water temperature safety control
(j) Checking and correcting up impeller of water pump for excess play.
(k) Checking and correcting turbocharger oil leakage, tightening of mounting screws and nuts
(l) Cleaning, tightening all electrical connection of engine
(m) Checking generator brushes (Alternator) and commutator and replacing the brushes.
(n) Cleaning of entire engine.
(o) Checking exhaust and inlet manifold bolts and cap screw
(p) Checking engine blow by.
(q) Cleaning of radiator inside and outside by removing and refixing after cleaning.
(r) Checking and adjusting injector and valves.
(s) Cleaning fuel inlet connections and screw,
(t) Changing of governor oil.
All as per item No.-67 here-in-before but diesel engine of 110 KVA DG set, at Sasson Comples
All as per item No.67 here-in-before but diesel engine of 82.5 KVA DG set at Vishakha RO Plant
All as per item NO 67 here-in-before but for diesel engines of 63 KVA DG set at Vatsala Pump house
Removing the old engine oil from the diesel engine sump of various DG sets, cleaning the oil sump thoroughly, supply and fill new engine oil of make Servo super 20W40 of Indian oil or equivalent grade of Hindustan Petroleum as directed by Engineer -in -Charge.
Repair/overhauling of self starter including replacement of worn out clutch assembly,bush,spring,plunger assembly, solenoid switch, carbon brushes, brush spring etc. for the following DG Set.
Repair/overhauling of dynamo including replacement carbon, brushes holder,spring,commutator/slipring assembly bearing, regulator etc. of any make, type and capacity.
Supply and fixing in replacement battery charger 24 Volts suitable for 12 volts 180 AH Battery complete all as specified and directed
Servicing/repairs of panel of DG set complete including cleaning resetting/adjustment of relays, calibration of time delay relays, checking and replacement if required of diods,resistors electrical wiring etc. complete for any make type and capacity of DG sets.
Dismantling the rediator assembly , flushing it complete, testing the radiator of water tightness,soldering the leakaghe spot, replace the loose radiator cap "V" belt, rubber hose and re connect the rqadiator assembly to engine and testing complete.
Servicing of alternator including cleaning of field and armature winding, varnishing and baking polishing of slip rings, checking and making correct excitation system etc. complete as specified and as directed for alternators of:-
Cleaning of the fuel tank of the following capacity DG sets after decaning the diesel, painting with one coat of approved colour synthetic enamel paint after thorough cleaning and preparation of surfaces, marking of fuel level gauge, fuel tank cap, writing of tank capacity
(b ) 82.5 to 110 KVA
Supply and replace rectifiers for alternators suitable for Gen sets upto 63 KVA to 125 KVA capacity
Supply and replace rectifiers for alternators suitable for Gen sets upto 100 to 125 KVA capacity
Supply and replace RPM meter complete with cable and accessories at the last range 0 to 2500
Supply and replace Diesel oil gauge 63/125 KVA .
Repair /reconditioning battery 12 volts 180 AH for holding charges for starting engine complete all as specified and testing and commisioning
Supply and fixing Self starter suitable for 100 to 125 KVA DG Set complete all as specified
Supply and fixing Disiel filter suitable for 63 to125 KVA DG Set complete all as specified
30. Supply and fixing Oil filter suitable for 63 to125 KVA DG Set complete all as specified
Callibration of fuel injector with authorised agencies of 63 to 125 KVA DG Set complete all as specified
Supply and fixing Air filter suitable for 63 to 125 KVA DG Set complete all as specified
Supply and fixing Amps meter 440 volts 96mmx96mm for 0 to 200 amps range with CT coils
Supply and fill distrilled water for topping up/replacing in batteries as on required basis
Supply and fill battery acid for topping up/replacing in batteries as on required basis
Preparation of old painted surface of installation by removing all dirt, dust, grease, oil etc and painting by painting spray machine complete surface including connected accessories with one coat of synthetic enamel paint of approved colour including writing of identification Nos, capacity etc all as directed by Engineer-in-Charge for DG Set/ LT panel
Repair / Servicing of unserviceable dainoma including cleaning of field and armature winding, varnishing and baking polishing of slip rings, checking and making correct excitation system etc. complete as specified and as directed for alternators of 100 KVA to 125 KVA
Supply and fixing dynamo belt as per size directed by Engr -In -Charge of cap 63 to 125 KVA
Supply and fixing starting lock with key and complete with all accessories complete for 63 KVA D G set to 125 KVA DG set all as directed by Engr -in- -Charge.
Opening top /side cover of alternator an disconnect the Lt suppy cable connecting box /AVAR fixing box and replace the damaged , broken unserviceable abonite sheet with cable copper lugs and cleaning the same all as directed by the Engr -in-charge.
Repair /replacement to 125 KVA stand by DG set . Dismantling 125 KVA DG set engine complete at site carefully take out various parts of engine and water pump transporting the engine and dismanttled items to authorised work sheet of Kirloskar oil engine at work shop, inspect all the engine parts carefully for its servicability segregate unserviceable spare parts for replacement machining the engine head to true profile pressure test the engine head for leakage and replace the undermentioned UNSV parts in toto, reassemble the engine complete retest the assembled the engine for proper fixing, testing the engine for 24 hrs for efficiency all as directed by Engr in charge.
(i) Strip opening of the engine and taking out the cylinder head taped, nozzle and all accessories.
(ii) Strip opening of the engine and taking out the piston , piston ring crank, tie rod, locks
(iii) Safe remove the exciter assembly of DG set , transport the same to workshop at authorized repair shop of M/S Kirloskar and remove the exciter winding from core assembly and replace the exciter core winding kusing same gauge and number of items turns with copperannealed wire, drying , smoking and assembling and testing complete. assembly for fault
(iv) Cleaning descaling/decarburizing engine block and galleries with the cleaning/descaling agent.
(v) Facing and grinding of valve seat inserts inlet/ exhaust to desired angle in inlet/exhaust ports of cylinder heads after replacement
(vi) Lapping of valve inlet/exhaust over valve seat in cylinder head
(vii) Recalibrating FIP , replace the alternator springs, fuel jets, return air spring, servicing testing, assemblingh and re fixing complete.
(viii) Repairing the cylinder head including fixing the valve, guide and re-fixing the cylinder head complete with fixing accessories.
(ix) Boring grinding of crank well and fixing cam bush properly in the original position.
(x)) Load testing the DG set for proper suppply, adjusting governer for proper speed, test the RPM and measure the LT supply on load for rated voltage and RPM working of the DG Set.
Supply and fixing in replacement of UNSV radiator for 125 KVA Gen set and taking down the same
Supply and fixing in replacement of UNSV radiator for 110 KVA Gen set scilent proof and taking down the same
Supply and fixing in replacement of UNSV fuel TR pump motorised for 125 KVA and taking down the same
Supply and fixing in replacement of UNSV pre Lub Hyd lift pump VIC for 63/100 KVA and taking down the same
Repair to burnt out alternator of capacity 100 KVA to 125 KVA DG set and carry out the following works complete all as specified and directed by Engr-in -charge
(a) Taking out alternator from the genrator and disconnecting all electric connections, removing from site to workshop for repair work and back to site after repair and making all electrical connection and testing .
(b) Opening the top cover of alternator and dismantling of cover and taking out burnt coils from the rotor, cleaning , decorbonate the rotor slots and replacing with new coils same after repairing/replacement making all electrical connections providing sundry items and reassembling after repair to entire satisfaction of Engr-in-Charge
© M/L for rewinding the alternator with super enameled copper winding wire of appropriate gauge alongwith allied material , including provision of cotton tape, glass sleeves insulation paper and insulating with varnish.
(d) Replacement to field coil and armature
(e) Replacement of rectifire, sleep ring and exiter coil
(f) Replacement of damaged unserviceable coil slot
(g) Making connection , checking testing and commissioning of alternater after repair and making alignment .
Supply and fixing in repairs of cada pinion ( gear wheel) and strip opening of close body alternator from the 100 /125 KVA generator and unscrew the alternator from the DG set taking out broken gear wheel with OD ring and replacement with new and replacement worn out bush con rod small end from connecting rod and press fitting new con rod bush and reaming to size of gudgeon pin .
Supply and fixing in repairs of broken cnopy door lock 04 Nos and hinged - 04 Nos of scilent proof DG set 63 to 125 KVA. Hinged fitted by welded by ges welded and lock by screw complete all as specified and directed by Engr-in -charge
Supply and fixing 12 Volt 180 AH battery with 24 plates , liquied immersed and fully charged Make- -Exide/Amron
Taking down the old unserviceable water body and before taking down un screw the ,fan, fan belt, hose pipe and remove the its position and replacement new water body as per sample.
Repair to AMF pannel of scilient proof DG set 63 KVA to 125 KVA and replacement the folowing items :
(a) MCCB 250 Amps 35 KA - 01 Nos (b) Fuse as per sample - 01 Nos
© Card as per sample- 01 Nos (d) Relay as sample - 02 Nos
(e) Timmer - 02 Nos (f) Display -01
(d) complete wiring and fuse and sencer unit etc.
Supply and replacement of AVAR for 100 to125 KVA DG set as per sample all as directed by Engr -in-Charger.
Supply, fix, install, testing and commissioning of Power factor Panel , outdoor type cubical shape, made out of CRCA sheet 3 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,1 ft long grouted on PCC foundation of height not less than 40 cm from the ground level , grouting properly and accommodate the items mentioned below. Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 20 KVAR and cylindercal type MD-XL capacitor bank of capacity 20 KVAR with APFC relay adjustable thermal magnetic release MCCB 63 Amps 3 pole breaking capacity 16 KA. and air circulating fan for cooling including all accessories . (a) Capacitor 5 x 2 = 10, (b) Capacitor 10 x 1 = 10 Total 20 KVAR
Supply, fix, install, testing and commissioning of Power factor Panel , outdoor type cubical shape, made out of CRCA sheet 3 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,1 ft long grouted on PCC foundation of height not less than 40 cm from the ground level , grouting properly and accommodate the items mentioned below. Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 60 KVAR and cylindercal type MD-XL capacitor bank of capacity 60 KVAR with APFC relay adjustable thermal magnetic release MCCB 160 Amps 3 pole breaking capacity 25 KA. and air circulating fan for cooling including all accessories . a) Capacitor 5 x 2 = 10, (b) Capacitor 10 x 2 = 20 © Capacitor 15 x2 = 30 Total 60 KVAR
S&F in repairs Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strips 25 x 4 mm.
Material and labour in repairs of Old uprooted Air Termination Rods including saddling with suitable saddles and nails all as directed at site by Engineer - in - Charge.
M&L in repairs Air termination, single pointed aluminium rod 12mm dia and 300mm long
Material and labour in repairs & secure hanging of Old uprooted lightening arrestor strips including saddling of strips with suitable saddles and nails all as directed at site by Engineer - in - Charge.
Taking down unserviceable and Supply and fixing CPT Cirprotec CPT-L ESE lightning rod with stainless steel body Type Advance lightning protection system in compliance with standard NFC 17-102 & UNE 21186-96, working on the principle of Early Streamer Emission technology which will offer Level 1 protection for up to 30 Mtrs Mtrs radius when mounted on the RCC concrete base on Building at a height of 4.5 mtrs from the place to be protected complete all as directed by Engr-in Charge. Make : NIMBUS-JEF Techno, perfect or equivelent make approved by GE
Taking down unserviceable mounting str and Supply and fixing mounting structure of 4.5 mtrs height with base plate suitable for roof mounting on RCC concrete base on Building complete all as directed by Engr-in Charge
Taking down unserviceable copper conductor and Supply and fixing of 1X50 sq mm copper conductor with 0.5 mm thick PVC sheathed cable complete all as directed by Engr-in Charge.
Taking down unserviceable digital lighting and Supply and fixing 4 digital electromechanical lightning event counter in weather proof resistance complete all as directed by Engr-in Charge.
Supply and fixing of test Link for connecting the earth pit and down conductor complete all as directed by Engr-in Charge.
M & L for maintainance free enviroment friendly earth electrode set comprising of 17.2mm dia,3 mtrs long rod of low carbon steel molecular copper bounded for a thickness of 250 micro ohms, highly conductive ANSI/NSF STD-60 certified carbon bound backfill compound which shall set like concrete according to BS 7430 & IEEE 80 (each bag shall contain 50 lbs) complete all as directed by Engr-in Charge. Make : JEF Ecosafe or equivalent, perfect or equivelent make approved by GE
Earthing with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick, burried directely in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25x4 mm with the help of bolts, nuts, and washers of galvanised iron or steel, including necessary excavation and earthwork, PCC 1:3:6 type C2 and Cast iron pit cover, watering arrangement with GI pipe funnel, jali, complete all as specified and shown in electrical plate No. 5 of SSR Pt-1, including testing on completion.
Supply, fix, install, testing and commissioning of LT Panel ,indoor type cubical shape,three phase, 4 wire, copper bus bar rating 400 amps for phases and 200 amps for neutral made out of CRCA sheet ,2 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,1 ft long grouted on PCC foundation of height not less than 40 cm from the ground level , grouting properly ,and of suitable size to accommodate the items mentioned below and having separate compartment /chambers for cable gallery busbar,switch gear and front side door openable , back side fixed wall etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc . Loc : Foma House
(i) MCCB 4 Pole, 415V, adjustable type, 250 Amps with breaking capacity 25KA -01 No (Incoming)Make- Schneider/Havells/Legrand
(ii) MCCB 4 pole 415V fixed type, 25 to 160 Amps with breaking capacity 16KA- 03 Nos (outgoing) Make- Schneider/Havells/Legrand
(iii) Motor star delta starter suitable for UPTO 40 HP motor - 02 Nos Make : L &T/ Sciemence
(v) Phase indicating lamps LED type ( red , yellow, blue) -03 set
(vi) MCB SPN 40 Amps- 06 Nos (outgoing)
Taking down 15 mm dia steel tuibing and connections from the wall, floor and ground complete all as specified and directed. Note : If excavation , earth work to be messured and paid separately under respect schedule.
All as per srl item No.123 here in before but of 20 mm dia
All as per srl item No.123 here in before but of 25 mm dia
All as per srl item No.123 here in before but of 40 mm dia
All as per srl item No.123 here in before but of 50 mm dia
All as per srl item No.123 here in before but of 80 mm dia
All as per srl item No123 here in before but of 100 mm dia
All as per srl item No.123 here in before but of 150 mm dia
Supply and laying GI tubing 15 mm dia medium grade with all fitting such as tee, socket, bend, union etc in trenches complete. Make : TATA/Jindal/Zenith/surya prakash
All as per srl item No. 131 here in before but of 20 mm dia
All as per srl item No. 131 here in before but of 25 mm dia
All as per srl item No.131 here in before but of 40 mm dia
All as per srl item No.131 here in before but of 50 mm dia
All as per srl item No.131 here in before but of 80 mm dia
Supply & Fix in replacement MS pipes 100mm dia conforming to IS 1239 (Part-I) medium grade with both ends flanged and drilled with standard MS fitting including 02 coats of synthetic enamel painting over one coat of red oxide primer in any length and fixed on walls, complete all as specified and directed in high rise buildings Note : MS flanges including welding to MS pipes and all flanged joints shall be measured and paid separately under respective item of Sch ‘A’
All as per srl item No. 137 here in before but of MS pipe 150 mm dia
PCC 1:4:8 type C2 (using 40 mm graded crushed stone aggregate) for plingth protection of semi under tank 0r suport to main water supply line or as required at site all as directed by Engineer-in-Charge.
Repair to unsewrviceable sluice valve of size 80 mm to 150 mm dia. Opening the nut,bolts both side flanged ,after taking down unscrew the top cover and taking out the spendle , gate with chucknut & repairing the same after replaced of gasket /gland/nut bolts etc.
Repair of broken and damaged brick masonry valve pit of size (105 x 105 x 105cm (finished internal dimensions ) using sub class "B" brick masonry in cement mortar cm 1:4 including plastering internally and painted flush externally as the work proceeds and PCC 1:2:4 type B-1 as in copping with angle iron frame 40 mm x 40 mm x 6 mm with 2 mm thick MS sheet cover two side open with 2 Nos hinges each side and 2 Nos lifting handle and in built locking arrangement including lock and key and surface with two coats of synthetic black paint and a coats of red oxide paint on steel surface including necessary excavation in any type of soil, earth work in any type of soil to distance n.exc 50 m all as speified.
S&F in replacement of unserviceable with new non return valve of CI body 80 m to 100 mm bore flanged with rubber packing including nuts bolts and wahsers etc complete as directed by EIC. Make : BIR/Kirloskar/ Kartar
M & L for drain out the water with the help of pimping set/Honda Gen set/by manually from the semi under ground sum of capacity 1 lakh gallones a to 2 lakh gtallons capacity for welding work / cleaning work all as specified and directed.
Rough execavation removing disintigrated material/rock by diging at Pump house and power house to semi under ground tank for drain out of rain water and depositing 50 mtrs away as directed by EIC .
Supply and fixing rubber Sheet 6 mm thick used for packing in sluice valve , NRV and flanged joint .
Material and labour for rubber gasket joint and flanged pipe 150 mm dia pipe , complete with jointing materials for jointing fittings with pipe all as specified, (Excavation shall be measured and paid separately
Material and labour for rubber gasket joint and flanged pipe 80 mm to 100 mm dia pipe , complete with jointing materials for jointing fittings with pipe all as specified, (Excavation shall be measured and paid separately
Welding/ cutting work for MS pipe/ GI pipe of any dia fixing of pipe as required shape and length for motor and pumps complete all as specified.
M&L for Painting of CI/GI pipe line 40 mm to 150mm inside the pump house and out side each pump house and all sluice valve, NRV gate valve) with one coat of synthetic enamel black/gray paint of existing colour shade with spray gun machine and after cleaning and preparation of surfaces complete all as specified & directed by EIC.
Taking down the broken iron coupling from the 35 HP to 75 HP motor / pump and fixing the new coupling with cotter pin, rubber piece and nut bolts as per sample.
Taking down the broken rubber coupling from the 35 HP to 60 HP motor / pump and fixing the new coupling with rubber piece and nut bolts as per sample.
Supply and replacement of unserviceable MCCB 400 Amps 3 pole 36 KA Make : L & T/ Havels/ legrand/seimens
Supply and lay electrical LT insulation rubber matting as per ISI of size 1m x 2m x 12 mm thick. Make : Jaipuria Brothers or equalent make approved by GE
Supply and fixing Nut and bolt of black bolt with hexagonal head and nuts round necks with washer of size 16 mm diameter and 100 mm length
Repair to leakage GI pipe line of size 40 mm to 150 mm dia pipe and welding work including the earth work and labour charge all as directed by EIC.
Cleaning and painting external surface with cement based paint complete, colour as existing Semi under ground RCC sump of cap 01 lakh to 02 lakh ltrs after draining out scraping out bottom and side of wall with wire brush and bleaching powder, removing scaling fungus, flushing thoroughly with clean water, applying on coat of white washing after drying inside, writing of tank capacity and date of cleaning and due date of cleaning in capital letters of 20mm size on external surface of wall with white enamel paint over black paint surface all as directed by Engr-in-Charge
M&L for fabricating supplying and positioning first aid box made of 1.6 mm CRCA sheet size 0.30x0.25x0.15 mtr duly powder coated painted white inside and outside after 7 tan treatment for corrosion resistance FIRST AID BOX letter wirtten with red capital letter preminently painted red on white back ground fixed with 2 Nos GI hanging strip with nail hole duly rivetted on the body drilling wall to position the box provide suitable fixing stand including bandage -04 Nos , Tincher bottle-02 Nos, Soframysin- 01 strip, Detol liquit bottle 0 01 Nos, Blade - 01 nos complete and fix the first air box at location as given by Engr-in-Charge
M&L for fabricating positioning glow sign board for E/M insallation map plot lay out. Translite glow sign made of GI sheet box frame with aluminium angle support front side transparent glow acrylic sheet 1.2 m x 0.90 x 0.15 m size/coloured glazed lettering on white acrylic sheet back ground using super glow paint and provided with flourescent glow light using 1 x 20 watt tube light fitting including internal wiring inside the box, external point wiring from the nearest DB including wall mounting
Supply and replacement single core copper conductor cable PVC insulated of size 35 sqmm , 1100 volt conforming to IS 694/1990.
S&F in replacement of unserviceable with new sluice valve flanged type with brass spindle including rubber, packing materials, nut, bolts and washers with locking arrangement in such a way that the valve can be locked in its open position ISI marked on body conforming to IS-14846 PN-1.6 of size 80 mm dia all as directed by EIC. Make : BIR/BVI/Zoloto/Kishan
S&F in replacement of unserviceable with new sluice valve flanged type with brass spindle including rubber, packing materials, nut, bolts and washers with locking arrangement in such a way that the valve can be locked in its open position ISI marked on body conforming to IS-14846 PN-1.6 of size 100 mm dia all as directed by EIC. Make : BIR/BVI/Zoloto/ Kishan
Material and labour for joints with 15 mm thick MS flanges slip type through welded to MS pipes complete with jointing materials such as rubber, gasket, nut bolts and washer etc for 100/150 mm bore pipe all as specified and directed.
Dismantling and taking down old u/s power contractor of any make and supply and fix 3 pole , 415 volts power contaractor suitable for motor upto 40 HP as per existing models at site Make- L & T/ Havells and equivallent as approved by GE.
Dismantling and taking down old u/s power contractor of any make and supply and fix 3 pole power contaractor suitable for motor upto 50 to 70 HP type Make- L & T/ Havells / seimence and equivallent as approved by GE.
Taking out Old rusted and broken Fresh water tank lid . Supply and fix in replacement of cast iron lid including locking arrangements black paint in /out side fixed on RCC water tank on top of building cap of tank 20000 gallons capacity
Supply and lay cable XLPE insulated screened. PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 Core. Make Havells/plaza/Poyacab
Supply and lay cable XLPE insulated screened. PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 Sqmm 3.5 Core. Make Havells/plaza/Poyacab
Disconnecting the taking out the unserviceable pump set of any make from the pump foundation after opening nuts/bolts, transporting from site to workshop, dismantling pump, removing worn out impeller, ball bearing, gasket, and replacene the unserviceable parts , gland packing, greasing, transporting back to pump house and refixing on the existing foundation, connecting the electrilc connection to the motror and testing complete to entire satisfaction of Engineer-in-Charge for the following capacity.
Centrifugal pump set of capacity 40 to /75 Hp
Centrifugal pump set of capacity 20 to 35 Hp
Centrifugal pump set of capacity 5 to 15 Hp
Material and labour for rewinding the electric motor of capacituy 60HP to 75 HP capacity, disconnecting the electtic connection of motor, earth connections, decoupling motor and pump, removing foundation nuts/bolts and removing the motor from its existing position to workshop (Note:- following workds deemed to be included in the quoted rates.) (a) Removing the split case/body cover of motor, seperate stator/rptar and cutting the complete burnt/defective copper winding. (b) Cleaning the stator body complete by rubbing and paper removal all carbons. (c) Insert insulating materials such as insulating paper sleeves. (d) Rewinding the stator with existing size of super enameled copper winding, varnishing and heaating up at desired temperature for achieve the particular Ohm resistance. (e) Clean the rotor and assembling in motor. (f) Connecting/coupling the motor with pump, connect all electric/earth connection foundation nuts.bolts at its original position and testing on load and complete all as specified and directed.
All as per srl item No. 169 here in before but Motor of capacity 40/55 Hp
All as per srl item No. 169 here in before Motor of capacity 20/35 Hp
All as per srl item No. 169 here in before Motor of capacity 5/15 Hp
M & L for dismantling the rusted foundation bed of the motor and pump set, and fabrication of the forundation beds with MS channels angle of the required as per pump set capacity( 40 HP to 75 HP) and duly applying one coat of red oxide primer and two coat of bitumen paint of approved quality and errction the pump and motor testing to the entire satisfaction of Engineer-in-Charge. Note:- (a) However quoted rate is deemed to be included for welding work, nuts, bolts, washer and MS fasteners including Concrete required for foundation
M & L for dismantling the rusted foundation bed of the motor and pump set, and fabrication of the forundation beds with MS channels angle of the required as per pump set capacity( 20 HP to 40 HP) and duly applying one coat of red oxide primer and two coat of bitumen paint of approved quality and errction the pump and motor testing to the entire satisfaction of Engineer-in-Charge. Note:- (a) However quoted rate is deemed to be included for welding work, nuts, bolts, washer and MS fasteners including concrete required for foundation
Taking down old U/S meter. Supply, fixing and testing water meter suitable to fit in 100/150mm bore in existing GI/CI pipe complete with flange, gasket, nuts, bolts and all necessary required items all as specified and directed by Engineer-in-Charge. Make : Kranti/
Disconnecting the electric connection and replaced unserviceable MCCB with new MCCB of the following Amps and capacity :-
(a) . MCCB 63 Amps, 25 KA capacity 3 pole. Make- Legrand/ABB/Siemens
(b) . MCCB 100 Amps, 25 KA capacity 3 pole. Make- Legrand/ABB/Siemens
(c) MCCB 200 Amps, 25 KA capacity 4 pole. Make- Legrand/ABB/Siemens
(d) MCCB 250 Amps, 36 KA capacity 4 pole. Make- Legrand/ABB/Siemens
Material and labour for scrubbing old paints from outer surface of plants and equipment including painting with two coat of synthetic enameled paint over one coat of red oxide paint and also writig AM/MES Nos on surface of the plant with white paint all as specifed and directed by Engineer- in -Charge. The following pump and motor as under :-
(a) Pump and motor set from 60-75 HP including suction and delivery upto 15 Mtrs
(b). Pump and motor set from 5 -45 HP including suction and delivery upto 15 Mtrs
Taking down old u/s PVC tank and Supply and fix PVC moulded water storage tank of 3000 Ltrs capacity cylindrical vertical type complete with inlet, outlet, overflow, and wash out connection, closed top cover complete including hoisting in position etc all as specified and directed by Engineer-in-Charge. Make Sintex/ Infra/ Polycon
Taking down old u/s PVC tank and Supply and fix PVC moulded water storage tank of 5000 Ltrs capacity cylindrical vertical type complete with inlet, outlet, overflow, and wash out connection, closed top cover complete including hoisting in position etc all as specified and directed by Engineer-in-Charge. Make Sintex/ Infra/ Polycon
Taking down old u/s PVC tank and Supply and fix PVC moulded water storage tank of 7500/10000 Ltrs capacity cylindrical vertical type complete with inlet, outlet, overflow, and wash out connection, closed top cover complete including hoisting in position etc all as specified and directed by Engineer-in-Charge. Make Sintex/ Infra/ Polycon
Taking down old unserviceable and broken PVC tank from G + 15 top of the building and fixing new tank the same position same location and fixing all out going and incomming pipes directed by engr -in-charge. Note : PVC tank of capacity will be paid and measured seperately under respective schedule.
Supply and fix Low density polyethylene 20 mm pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc including clamps and srews and all as specifioed and directed by Engineer-in-Charge.
Cleaning of PVC tank in any position by rubbing, washing removing the scales dust etc including plugging the insets dusting washing all as directed
(a) Capacity up to 3000 to 5000 Ltrs
(b) Capacity up 7500 to 10000 Ltrs
Cleaning of RCC 5000 to 10000 gallons tank in any position by rubbing, washing removing the scales dust etc including plugging the insets dusting washing all as directed
Repair/Maintenance to Chlorine dozing system assembly with chlorine injector dozing pump, cleaning, servicing, carrying out minor repairs and testing. (Note : (a) Work is including consumables like cotton waste cloth etc. (b) Parts and spares requied to be replaced.
Supply & fixing in replacement of dosing Pump high pressure single head gear motored adjustable dosing pump with accessories include lead tubing, connecting nuts, injection check valve, clay weight, ferules etc. Make Aquafit /Declibac or equvilent make approved by GE.
Disconnecting all electric connections from the chlorine dosizing motor 1.5 HP & taking out column assly from motor and supply and fixing 1.5 HP motor as existing sample all as directed by Enge -in-Charge.
Supply and Fixing in replacement of dosing system consisting 40 ltr-100 ltr PE/FRP Tank with PE/FRP Lid & level gauge along with agitator with shaft & blade in plastic tank. Make Aquafit /Declibac
Supply only Calcium Hypochlorite in granular form in 45 Kg drum, having minimum 70% of available chlorine (Ca(OCI)) with anti-corrosive and anti-scaling properties suitable for human consumption. Make: PuriChlor (SRHSH). Note: Contractor shall produce letter of authorisation, COA with unique serial number and NSF certiifcate from manufactuer. Make Aquafit/Decliback/Purichlor
Supply and fix in replacement of new butterfly valve of PN 1.0 of dia 80mm
Supply and fix in replacement of new butterfly valve of PN 1.0 of dia 100mm
Supply and fix in replacement of new butterfly valve of PN 1.0 of dia 150mm
Supply and fixing PVC polyethylene water storage tank lid of any capacity with locking arangement as specified and directed by Engineer-in-Charge.
S&F in replacement of unserviceable with new non return valve of CI body 100 mm bore flanged with rubber packing including nuts bolts and wahsers etc complete as directed by EIC : Make : Zolota / Leader / HM
Supply and fixing in replacement 40 mm of gun metal globe or gate valves, with iron whel head, screwed both endes for iron pipe. Make : Zolota / Leader / HM
Supply and fixing in replacement 50 mm of gun metal globe or gate valves, with iron whel head, screwed both endes for iron pipe. Make : Zolota / Leader / HM
Supply and fixing in replacement 80 mm of gun metal globe or gate valves, with iron whel head, screwed both endes for iron pipe. Make : Zolota / Leader / HM
Siupply and fixing L Shape and stright copper Patti using for fixing of MCCB in LT panel for suitable current rating or required at site.
Disconnecting all electric connections from the submersible pump & motor 03 HP & taking out column assly from bore well and transporting the same to civil workshop for repair . directed by Enge -in-Charge.
Taning out unserviceable submersible pump from the bore well and supply and fixing 3 HP submersible pump 3 phase 420 Volt all as per directed by Engr- in-Charge .
Disconnect the electric connections form starter and taking out burnt submersible starter from the existing position. Supply and fixing new water sensor, starter 3 phase of 10HP , 440 Volt , front side openable and locking arrangement all as per directed by Engr- in-Charge .
Taking down old unserviceable pressure gauge with the help of gas cutter/ monkey packed and in replacement new Pressure gauge 100 mm dia with ball valve of pressure 25 Kg/Sqcm directed by Engr-in-Charge.
Water testing report of BASIC TEST / HEAVY METAL TEST /PATHOGENS TEST as per list . Collection of empty sterlised bottles from the Govt/ authorised lab Mumbai , Maharashtra after taking out water sample from user end / pump house. Water sample filled bottle depositing to the same lab for anaylsis test and collect the sample report and deposited to E/M sub divn all as directed by Engr-in-Charge Location : Reviera/ INS Shikra/ NT Pool/ Sasson Complex/ Bhagirathi/ Aditi/ Vishakha
Opening of nut and bolt for the pump and Taking out pipe / unserviceable/rusted foot valve and replacement with new foot valve, 150 mm size PN-1.6 pressure rating including all joints with rubber or fibre board, bolts, nuts washers, etc. and fix the pipe/ valve in water tank / pump complete all as specified and directed by Engr-in-Charge.
Opening of nut and bolt for the pump and Taking out pipe / unserviceable/rusted foot valve and replacement with new foot valve, 100 mm size PN-1.6 pressure rating including all joints with rubber or fibre board, bolts, nuts washers, etc. complete all as specified and directed by Engr-in-Charge.
Routine maint of centrifugal pump / NRV / sluice valve/Non return valve by attending fault testing of system regularly basis to insure serviceability and checking of system , including replacement of unseriviceable component including preventive maintinance spares by replacing minor parts i.e galand packing nut and bolts complete all as specified and as directed. Note :- If the contractor will not attend the complaints by his trades man in any working day , the necessary reovery of Rs. 500/- per day shall be imposed complaint not attended within 24 hrs and checking of non ops pumps /valve /foot valve each location in routine wise per day by trades men.
Supply and fixing of water level indicator one Nos of each semi under ground sump with all accessories i.e Angle iron 12 feet long of size 25 x 25 mm, 4mm thick and two angle fix (welding ) 45 degree angle, steel wire as required gauge, PVC cane/drum , moving roller , welding work etc and one coat of synthetic enamel black paint front / back side and written / marking level gauge with white /red paint with all necessary safety equipment, helmet, ladder, rope, safety belt etc provided by contractor , complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of old monoblock Booster pumps with motor 7.5 KW / 10 HP for 415V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 415 volts, 3 phase, 50 Hz 70 mtr head, 5.4 LPS / 324 LPM discharg , 2050 RPM. Make Kirloskar/ crompton
Taking out old Unserviceable LT Panal from pump house and Supply, install, testing and commissioning of motor on /off LT Panel CPRI Approved mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type, with front side opening or suitable fixing of all breakers and controls for 415V, 3 phase, made of 2 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 600 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections Panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary farmework and PCC foundation including shifting of existing of LT Panel if any making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :- Loc - NT Pool / INS Shikra pump house Make of MCCBs/ACBs : Legrand / Schneider / L&T
(a) Motor star delta starter suitable for UPTO 12.5 HP motor - 02 Nos
(d) MCCB 250 Amps, 36 KA FP - 01 Nos Make: Legrand / L & T/ABB/Havells
(f) MCCB 100 Amps, 36 KA, FP - 04 Nos Make: Legrand / L & T /ABB/Havells
(h) Aluminium bus bar 400 Amps for phase & 200 Amps for neutral complete with bus bar insulator,nuts & bolts complete.
(j) Power panel wiring between bus bar to MCCB of different capacity with PVC insulated multistranded copper cable , 10 Sqmm ,single core ,1100 volts grade of appropriate size complete with copper lugs
€ Digital Ammeter-03 No, Make-HPL ,SP CL-1.0/AE
(f)Digital Voltmeter-03 No Make-HPL ,SP CL-1.0/AE
(g) Phase indicator lamp R,Y & B with slector switch - 03 Set
Darpan Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .