Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹9.6 L+₹54,078 (5.94%)Rejected-Finance VILL NAYA GUGNAN PO SUJANPUR TEH DISTT PATHANKOT 145023 | PATHANKOT | PATHANKOT | PUNJAB | 145023 | L2 | Rejected-Finance Not found lowest | |
| 3 | L3₹11.1 L+₹2.0 L (22.1%)Rejected-Finance GOVT CONTRACTOR VILL NAYA SUJAN FEROZPUR KALAN TEH DIST PATHANKOT PIN 145023 | PATHANKOT | PATHANKOT | PUNJAB | 145023 | L3 | Rejected-Finance Not found lowest | |
| 4 | L4₹11.5 L+₹2.4 L (25.8%)Rejected-Finance | L4 | Rejected-Finance Not found lowest | |
| 5 | L5₹11.9 L+₹2.8 L (31.1%)Rejected-Finance | L5 | Rejected-Finance Not found lowest |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
16 Apr 2022, 6:00 pmClosed
GE basoli JK
GE Basoli PO lakhanpur Distt Kathua JK
REPAIR AND MAINTENANCE OF SUB MAIN WIRING DBS, MCCBS, FITTINGS FIXTURES, SOLAR WATER HEATERS AND ALLIED SERVICES AT MADHOPUR UNDER GE BASOLI
2022_MES_514490_1
GE/BAS-62/2021-22
Open Tender
Civil Works
Item Rate
180 days
Madhopur under GE Basoli
class E catg b(I)
7 documents required · 7 mandatory
₹500
Yes
GE Basoli
₹26,000
Yes
5 Jan 2023
21 Mar 2022
18 Apr 2022
21 Mar 2022
16 Apr 2022
2 Apr 2022
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and as directed.
S&F in replacement of Point wiring with 1.5 Sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable in and incl rigid PVC conduit concealed medium grade with pressed mild steel terminal boxes(sheet not less than 1.6 mm thick) duly painted with a coat of red oxide primer with suitable thickness plastic laminated sheet cover 3mm thick of adequate size for one light or one fan controlled by one switch incl 1.5 Sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable as earth wire(green colour) to common earth dolly complete all as specified and directed. Note: a) Rate for cutting chases for conduits and sinking for boxes and making good to wall, floors deemed to be included in each point etc (b) On RCC roof ceiling PVC conduit shall be provided on surfaces for any necessary pointwith proper fixing clips and no extra cost shall be paid for the job etc all as directed.
All as per item No 2 but for one 3 pin 5 Amp socket outlet on independent board complete.
All as per item No 2 but for one 3 pin 5 Amp socket outlet on same board complete.
All as per srl item No 2 here in before but one bell/buzzers point controlled by one push button on the same board with other inner switches or independent with cable 1.5 sqmm size all as per specified and directed.
S&F in replacement of Point wiring with 2.5 sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable drawn in and including rigid PVC concealed conduit medium grade of suitable size with sunk cast iron/pressed steel terminal boxes(sheet not less than 1.6mm thick) of adequate size with suitable thickness plastic laminated sheet cover 3mm thick for one 3 pin socket outlet 15 Amp on independent board including continuous 2.5 sqmm FRLS,PVC insulated and unsheathed copper conductor cable (multistranded) as earth wire to common earth dolly, complete all as specified and directed.
S&F in replacement of Point wiring with 1.5 Sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable in existing conduit concealed and sunk cast iron/pressed steel terminal boxes painted duly painted with a coat of red oxide primer with replacement of suitable thickness3mm plastic laminated sheet cover of adequate size for one light or one fan controlled by one switch incl 1.5 Sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable as earth wire(green colour) to common earth dolly complete all as specified and directed.
All as per item No 7 but for one 3 pin 5 Amp socket outlet on independent board complete.
All as per item No 7 but for one 3 pin 5 Amp socket outlet on same board complete.
All as per srl item No 7 here in before but one bell/buzzers point controlled by one push button on the same board with other inner switches or independent with cable 1.5 sqmm size all as per specified and directed.
S&F in replacement of Point wiring with 2.5 sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable drawn in existing concealed conduit and sunk cast iron/pressed steel terminal boxes duly painted with a coat of red oxide primer with replacement of suitable thickness3mm plastic laminated sheet cover with suitable size for one 3 pin socket outlet 15 Amp on independent board including continuous 2.5 sqmm multistrand copper conductor cable FRLS PVC insulated and unsheathed Cable as earth wire to common earth dolly, complete all as specified and directed.
S&F in replacement of switch piano flush button single pole one way 5 amps 230 volts,complete all as specified and directed .
S&F in replacement of socket outlet 5 amps 5 pin flush type, 230 volts, complete all as specified and directed .
S&F in replacement of Switch socket combination 2 in 1, 5 pin, 5 Amp flush type complete all as specified and directed .
S&F in replacement of switch piano flush button single pole one way 15 amps 230 Volts, complete all as specified and directed .
S&F in replacement of socket out let, 6 pin, 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts, complete all as specified and directed .
S&F in replacement of in Switch socket combination 2 in 1, 6 pin, 5 and 15 Amp flush type universal complete all as specified and directed .
S&F in replacement of Bell push, flush type, 5 amp one way complete all as specified and directed .
S&F in replacement of fan regulator electronic flush type stepped (rotary type) with 5 steps speed control complete all as specified and directed .
S&F in replacement of Lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings complete all as specified and directed .
S&F in replacement of ceiling rose surface bakelite two to three terminal isolated body fixed on PVC round block complete all as specified and directed .
S&F in replacement LED tube light fitting 1x20w,230v, including LED tube rod with polycarbonate diffuser , 4 feet Patti type type fitting fixtures, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size. complete all as specified and directed .
S&F in replacement LED tube light fitting 20w,230v, including LED 4 feet Batten type fitting fixtures, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed .
S&F in replacement of decorative LED wall light fitting suitable for 9 watt LED with 100 lumen/watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable from ceiling rose to terminal block, and testing complete all as specified and directed. Note :- Rates of 9 watt LED bulb are deemed to be included in quoted rate
S&F in replacement of wall mounted LED bulk head fittings, 10 watt, warm white,, 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed.
S&F in replacement sheet metal powder coated VTPN DB double door 4 way with MCCB 100 amps, 415 Volts, 50 Hz AC 16 ka 4 pole with copper bus bar rated 200 amps neutral link, earth bar and din rail for fixing the MCBs complete all as specified and directed . Note :-MCBs Shall be measured and paid seperately.
S&F in replacement sheet metal powder coated VTPN DB double door 4 way with MCCB 125 amps, 415 Volts, 50 Hz AC 16 ka 4 pole with copper bus bar rated 200 amps neutral link, earth bar and din rail for fixing the MCBs complete all as specified and directed . Note :-MCBs Shall be measured and paid seperately.
S&F in replacement MCB TPN 63 Amps with 10 KA breaking capacity of 'C' series in distribution boards complete all as specified and directed .
S&F in replacement sheet metal enclosure for DB TPN 4 Way Powder coated with 200 Amps rated Bus Bar dobule door mopunted finish on wall complete all as specified and directed .
S&F in replacement sheet metal powder enclosure powder coated versatile double door 4way (SPN) distribution board for MCB provisions 230Volt, 50Hz AC with neutral link , earth bar complete all as specified and directed .
All as per item No 30.00 but but (SPN) DBs 08 way complete.
All as per item No 30.00 but (SPN) DBs 12 way complete.
All as per item No 30.00 but with single cover (SPN) DBs 02 way complete.
S&F MCBs single pole and neutral (SPN) 63 Amps with 10 KA breaking capacity of 'C' series in distribution boards all as specified and directed.
S&F in replacement MCBs single pole (SP) 5 to 32 Amps with 10 KA breaking capacity of 'C' series in distribution boards all as specified.
S&F in replacement MCBs single pole and neutral (SPN) 40 Amps with 10 KA breaking capacity of 'C' series in distribution boards all as specified and directed.
S&F in replacement of sub main wiring with two run of single core (FRLS) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area 4.0 Sqmm drawing into and including PVC non metallic rigid conduit of adequate size and making electric connections including one run (FRLS) PVC insulated single core copper conductor cable 4.0 Sqmm as a earth continuity conductor(green colour) in and including existing conduit complete all as specified and directed by . Note :- (i) Rates are deemed to be included chases of conduit and sinking for boxes cutting and making holes in wall/floor for passing in or through conduit (ii) Two run of 4.00 sqmm single core (FRLS) PVC insulated copper conductor cable one run of 4.0 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of suitable size will be measured as a one unit.
All as per item No 37.00 but with 2 run of 6.0 Sqmm and one run of 6.0 Sqmm as earth continuity conductor(green colour) complete all as specified & directed.
All as per item No 37.00 but with 2 run of 10.0 Sqmm and one run of 10.0 Sqmm as earth continuity conductor(green colour) complete all as specified & directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 of SSR Part-I (2009) including filling of charcoal dust , common salt all around Earth plate upto 150mm, 20mm bore GI medium grade watering pipe, 15 mm bore light grade earth lead protection pipe upto main board, funnel with wiremesh, 40mm thick RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate reinforced with suitable handle and angle iron frame and necessary excavation and earth work in any type of soil etc. complete all as specified and as directed including testing on completion. (Note: The rate quoted include cost of min 7.5 metre earthing wire .)
Taking out old UNSV existing board including any type of civil work Brick work, plastering, grouting to match with the existing no amount shall be paid extra for proper finish and for white wash after finish all as specified and directed.
S&F in replacement switch piano flush button single pole one way 5 amps 230 volts,complete all as specified and directed.
S&F in replacement socket outlet 5 amps 5pin flush type, 230 volts, complete all as specified and directed .
S&F in replacement switch piano flush button single pole one way 15 amps 230 Volts, complete all as specified and directed .
S&F in replacement socket out let, 6 pin, 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts, complete all as specified and directed .
S&F in replacement Switch socket combination 2 in 1, 6 pin, 5 and 15 Amp flush type universal complete all as specified and directed .
S&F in replacement Switch socket combination 2 in 1, 5 pin, 5 Amp flush type complete all as specified and directed .
S&F in replacement Switch Bell push, flush type, 5 amp complete all as specified and directed .
S&F in replacement Lamp holder insulated body with back plate for batten fittings, complete all as specified and directed .
S&F in replacement spring loaded rotary type bipin holder suitable for tube light fittings all as required at site or directed.
S&F in replacement fan regulator electronic flush type stepped (rotary type) with 5 steps speed control complete all as specified.
S&F in replacement electric bell ding dong AC single phase 220 volts, complete all as specified and directed.
S&F in replacement plug top 3 pin 5 amps AC 230 volts complete all as specified and directed.
S&F in replacement plug top 3 pin 15 Amps AC 230 volts complete all as specified and directed.
Supply only LED bulb of capacity 9 watts complete with all accessories base (ISI marked) all as specified & directed .
Supply only LED bulb of capacity 12 watts complete with all accessories base (ISI marked) all as specified & directed.
Supply only LED Tube rod LED tube rod with polycarbonate diffuser4 feet long of capacity 18 watts complete with all accessories base (ISI marked) all as specified & directed.
M&L for taking down replacement the existing faulty single phase tamper proof Electronic Energy meter with LCD display 230 volts 4 wire system, 10-60 amps, 50 Hz , complete,making , including testing, caliberation & refixing the same complete all as specified and directed .
S&F in replacement PVC connection 15 mm bore size with PTMT nuts,rubber washers etc complete of length 450 mm long complete all as specified.
S&F in replacement geyser element 2.0 KW, ISI marked with gasket, nuts, bolts suitable for the existing triangular/round shape/make of the geyser under repair complete all as specified.
S&F in replacement geyser element 1.5 KW, ISI marked with gasket, nuts, bolts suitable for the existing triangular/round shape/make of the geyser under repair complete all as specified.
S&F in replacement thermostat (ISI marked) suitable for existing make of the geyser under repair of cap 50/25 Ltrs complete all as specified.
S&F in replacement geyser safety valve (pressure release valve) for the exsiting make & capacity of geyser complete all as specified.
S&F in replacement 3 Core PVC insulated PVC sheathed flexible copper wire multistranded of size 2.5 sqmm complete all as specified and directed.
M&L for removing old burnt winding of exhaust fan 450mm sweep motor and rewinding the same with superior quality super enamelled copper wire of suitable size including insulation ,drying after varnishing complete all as directed and specified.
M&L for removing old burnt winding of exhaust fan 300mm sweep motor and rewinding the same with superior quality super enamelled copper wire of suitable size including insulation ,drying after varnishing complete all as directed and as specified.
S&F in replacement of capacitor 4 mfd ISI marked complete all as directed.
Taking down ceiling fan of any make & sweep by disconnecting clips,lock nuts etc. from existing position of any height in safe costudy for repair & mainteance. (Note: Repair & Maintance Shall be paid separetly under relevant items.)
Hanging only ceiling fan 1200mm/1400mm sweep after repair & maintenance with existing down rod clips,lock nuts etc. complete all as directed and as specified.
M&L for Painting of ceiling fans complete, in situ/lying in store with synthetic enamel paint (white colour) by spraying including filling cavities with filler, one coat after cleaning all dust etc, complete all as directed and as specified.
M&L for removing of old burnt winding of ceiling fan any type and capacity and rewinding the stator with superior quality super enamelled copper wire of suitable size including insulation ,drying after varnishing complete all as directed and specified.
S&F in replacement bearing for ceiling fan 1200mm/1400mm sweep ISI marked complete all as specified.
S&F in replacement Gun metal bush for ceiling fan 1200mm/1400mm sweep complete all as specified.
S&F in replacement cup made of plastic complete with nut bolt for fixing in position suitable for ceiling fan 1200mm/1400mm sweep complete all as specified and directed.
S&F in replacement rubber bush/reel for hanging bracket suitable for ceiling fan 1200mm/1400mm sweep complete all as specified and directed.
S&F in replacement blade suitable for 1200mm sweep Ceiling fan complete all as directed.
S&F in replacement blade suitable for 1400mm sweep Ceiling fan complete all as directed.
S&F in replacement 3 core PVC insulated PVC sheathed flexible copper wire multistranded 1.5sqmm from ceiling rose to fan connector complete all as specified and directed.
S&F in replacement of capacitor 2.5 mfd ISI marked complete all as directed.
S&F in replacement of capacitor 3.15 mfd ISI marked complete all as directed.
S&F in replacement of PVC Exhaust Fan of 225 mm sweep 230 volts 50 c/s of all as specified and directed.
S&F in replacement of PVC Exhaust Fan of 250 mm sweep 230 volts 50 c/s of all as specified and directed.
M& labour for service wire10 sqmm 2core pvc insulated and pvc sheathested1100 volts grade all as specified and directed
M& labour for service wire16 sqmm 2core pvc insulated and pvc sheathested1100 volts grade all as specified and directed
Matrial and labour or repairs to solar water heater system by checking the leakage/sepage of the system if found rectified through the authorised dealers, Draining out the system by opening the cold water outlet and hose to the bottom of soft water, check the crrosion sacrificial anode, repalce if found defective clean the colloector of capacity 100 LPD complete all as specified and as directed.
S&F in repair copper pipe pipes 20 mm including all fittings on walls/ceiling or laying in floors compete all as specified and directed.
Servicing to Solar Water Heater in and including replacement of solar panel optical reflector (glass type)- 01 Nos for conversion into solar energy to heat energy suitable for 100 ltr capacity including replacement of broken pipes, unserviceable valves complete in all respect to make the solar water heater serviceable and testing in presence all as specified by .
Disconnecting exsiting cable connections from exsiting DC SMPS system including replacing the unseviceable parts like MCBs, wires and cotoller etc. Rewinding of transfomrer with super enammelled copper wire integrated with insulation class A and shall be inform input voltage shall be 400-440 V AC, 50 Hz input with holding capacity shall be at 600VAC for 1 min. Transformer should be capable to deliver 200A current on uotput side at desired rectified voltage all as specified and directed.
S&F in replacement of 25 Watt LED Post top lantern made in cast aluminium spigot, spun aluminium power coated top cover aluminium PDC heat sink , Opal PC diffusyer and clear acrylic IP 65 protection complete all as specified and directed.
Supply and fix in replacment of 45 Watt Bldg security light fitting of IP-65 protection, pressure die cast aluminium housing with epoxy coated finish having polycarbonate cover & connecting up with three flexible copper condcutor cable of size 1.5 Sqmm three core including bracket of 25 mm dia GI pipe inluding clamp, nuts and bolts complete all as specified and directed.
S&F in replacment 12V ratyed SMF VRLA battery maintenanace free 150 AH suitable at side with all accesories cmplete all as specified and directed.
Substantial Const. Co.
BALKRISHAN GUPTA AND SONS
Ashoka Engineers
SHUSHANT ASSOCIATES
JP AND CO.
Amrik Construction co
JAI DURGA CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .