Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.5 L+₹96,200 (2.96%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹33.6 L+₹1.1 L (3.28%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹33.7 L+₹1.2 L (3.56%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹33.7 L+₹1.2 L (3.75%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 Jul 2022, 6:00 pmClosed
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
REPAIR TO PROTECTIVE WORKS, HARD STANDING/ PATHWAY, FENCING AND MISC WORKS AT JWG AREA AND REPAIR/MAINT OF LT OVER HEAD CONDUCTOR, UNDERGROUND CABLE, LT PANEL AND ALLIED ACCESSORIES IN THE AOR OF AGE B/R-III UNDER GE 881 EWS
2022_MES_534353_1
GE/PNH-22/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹60,000
Yes
19 Sept 2022
28 Jun 2022
26 Jul 2022
28 Jun 2022
19 Jul 2022
12 Jul 2022
Amount
B/R PORTION Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion in concrete, brick work, masonry etc and making good disturbed ground, complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion in natural ground and making good disturbed ground and preparing post holes for proviing new posts in any type of soil complete all as specified and directed.
Taking down carefully old galvanised stranded steel barbed of any description from old RCC or steel pole (each line wire to be measured) and removing frim site, complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically described (reinforement cut as required to facilitate demolition), complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and directed.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
Taking down cement plaster of any description on stone or brick walls etc including racking out joints, hacking for key scrubbing down with water etc. complete all as specified and directed.
Excavation in post holes each not exceeding 0.5 cum getting out in any type of soil, returning, filling in, including spreading, leveling, watering and well ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface, complete all as specified and directed.
M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations filling and mass concrete, complete all as specified and directed.
S&F mild steel work as in posts and struts in fencing including cuttings, tops to shapes, as directed, drilling, holes, notching for wire etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. fixed and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F galvanised, 2 strand steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing and tying at crossings with and provision of galvanized (zinc coating 60 gram) mild steel wire, staple or steel pins, etc complete all as specified and directed.
Supply only chain link MS galvanisd (zinc coating 60gram) fencing, any size or type, complete all as specified and directed. Note:-Type / size of fencing holes / dia of chain link fenching shall be as approved by GE. The weight of chain link fencing shall be calculated for payment as per actual weight or standard weight as per SSR which ever is less.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire, complete all as specified and directed.
M&L for RCC (nominal mix) type B-1 (1:2:4) using 20mm graded crushed stone aggregate as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slab, shelves, pillars, piers, posts and struts, complete all as specified and directed.
Form work to soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for rough finished surfaces of concrete, complete all as specified and directed.
S&F TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified and directed.
S&F TMT bars, 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia, complete all as specified and directed.
S&F Mild steel screw bolts dia not exceeing 15mm at neck, machine made, with hexagonal or square heads at one end and screwed the other, or screwed both ends; each screwed and to be fitted with washers and one hexagonal or square nut, length of bolt 5cm to 10cm long, complete all as specified and directed.
Supply & Fix 4mm dia plain mild steel wire, galvanised class 3, in fencing including straining and fixing to wood, concrete or steel posts and/or to straining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, etc. complete all as specified and directed. Note: (each line of wire to be measured)
S&F concertina coil fencing with punched tape made to shape as directed having dia exc 450mm but nexc 600mm put on top of wall in between angle iron Y shaped post and secure with necessary binding wire complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius, built in cement mortar (1:6), complete all as specified and directed.
M&L for walling of random rubble stone masonry brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed.
All as per item No.22 above, but except stone complete all as specified and directed
M&L for boulder filling hand packed tightly (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level, complete all as specified and directed.
M&L for rendering 20mm thick on other than fair faces of brick or stone masonry wall surfaces in cement mortar 1:4 and finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 15mm thick cement plaster rendering in CM 1:4 on fair faces of bricks or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:6 on other than fair faces of brick or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Raking out joints / pointing to random rubble or polygonal rubble uncoursed or brought up to courses build in cement mortar, complete all as specified and directed.
M&L for raised pointing to random rubble masonary, or polygonal rubble, uncoarsed or brought upto courses in cement mortar 1:4, complete all as specified and directed.
M&L for applying three coats of white wash including preparation of newly plastered surfaces of wall complete all as specified and directed.
M&L for preparation of newly plastered or unplastered surfaces of wall and applying two coats of cement base paint, complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint of Ist quality over a coat of red oxide primer to new or previously untreated steel surfaces over 10cm width or girth including preparation of surfaces, complete all as specified and as directed.
M&L for providing precast cement concrete 1:3:6, type C-1 (using 20 mm graded stone aggregate) as in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling) corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar 1:6 complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base floor finishing surface even and fair, complete all as specified and directed.
M&L for chequered cement concrete tiles 300x300x 25mm thick, set & jointed in neat cement slurry in floors and pointed with equal proportion of white and grey cement and no pigments, laid over and including 20mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for PCC 1:2:4 Type B-1 (using 20mm graded crushed stone aggregates) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring/path etc, complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 80mm thickness M-40 Grade,laid jointed pointed with grey cement and no pigments, complete all as specified and directed by Engr-in-Charge. Note: The sample shall be got approved by GE before bulk procurement & lot shall be got tested independently by the GE.
M&L for sand filling under pavers and packing the joints of paver block with sand, including watering and consolidation complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) pipes 110mm dia any length single socketed with rubber ring joint laid in trenches/floors, complete all as specified and directed.
Cleaning of under ground sewage lines of 100mm/150 mm bore including manholes, CI stacks.gully traps etc. by means of cleaning by roding from manholes to manholes till the cleared/cleaned water running under sewage line and flushing after cleaning, taking out sludge collected in manholes, removing & depositing the same outside the periphery of defence land in the pit at a minimum distance of 50 m from nearby living accn and covering the sludge in pit with earth and finally spraying unslaked lime, dry, around the manholes including taking off and re-fxing cover the manhole pitt, complete all as specified and directed. Note:-Cost of Taking out sludge, transporting of sludge out side the defence land, earth work & deposition in the pit is deemed to be included in the unit rate to be quoted by tenderer.
Opening of cover (of any description and size) of septic tanks and soakage wells/pits, de-sluding / de-watering contaminated with fine waste materials ( liquid sludge) alongwith solid waste from septic tank and soakage wells/pits of any capacity/depth by mechanical pumping (Truck mounted mechanical machine) / manually making it fully functional to to entire satisfaction of Engineer-in- charge and and removing & depositing the sludge outside the periphery of defence land at a minimum distance of 50 m from nearby living accn and burying in borrow pits including covering with fresh mud and refixing the cover after cleaning / removing the liquid waste material of septic tanks / soakage wells / pits including cutting holes through slab/ wall where required for inserting pipe and making good the same with cement mortar to match with existing surfaces complete all as specified and directed by Engr-in-Charge. Note:-Cost of Taking out sludge, transporting of sludge out side the defence land, earth work & deposition in the pit is deemed to be included in the unit rate to be quoted by tenderer.
Cleaning of blockage of Water Closet (Indian or European), trap & pipe line upto first manhole manually by Roding and making it fully functional by flushing with water to entire satisfaction of Enginerr-in-charge including removing the deposited sludge/solid/liquid material, outside MD land and burying in borrow pits including covering with fresh mud, complete all as specified and directed by Engineer-in-charge. Note:-Cost of Taking out sludge, transporting of sludge out side the defence land, earth work & deposition in the pit is deemed to be included in the unit rate to be quoted by tenderer.
S&F in repair PVC (SWR) pipes 110mm dia any length single socketed with rubber ring joint laid and fixed to walls, complete all as specified and directed.
S&F in repair PVC (SWR) pipes 75mm dia any length single socketed with rubber ring joint laid laid and fixed to walls, complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius 110mm bore, complete all as specified and directed.
S&F in repair 110mm PVC (SWR) junction single, (single T) equal or unequal provided without oval access door, complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius 75mm bore fixed, complete all as specified and directed.
S&F in repair 75mm PVC (SWR) junction single, (single T) equal or unequal provided without oval access door, complete all as specified and directed.
S&F in repair vitreous china squatting pan (Orissa pattern) size 580 x 440 mm, snow white, with 'P' or 'S' trap, front or back inlet and integral foot rests, complete connection to drain (outgoing pipe) and to flushing pipe and syphonage pipe etc. including lime concrete bedding, complete all as specified and directed. Make:- Prayag cat part No4054 or Equaivalent cat part of make as specified in P.S.
S&F in repair PVC valve less symphonic action type flushing cistern 10ltr capacity , low level white with inlet ball valve float and handle including brackets including 32mm dia PVC. flush pipe for low level cistern including all joints complete all as specified and directed. Make:- Prayag cat part No 501 or Equaivalent cat part of make as specified in P.S..
S&F in repair PVC connection 15mm size with PTMT nuts on both ends of length 450mm, complete all as specified.
S&F in repair vitreous china urinals, bowl type of size 465x355x265mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern and waste pipe),complete including poviding and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing with automatic flushing cistern with brackets, flush pipe, waste pipe grating and union for discharge pipe complete all as specified and directed.
E/M PORTION Excavation in trenches not exc. 1.5 m wide and not exc. 1.5m in depth for foundation of poles, stay assembly etc and getting out in hard/ dense soil complete all as specified and directed.
Excavation in trenches not exc. 3 m wide and exc. 1.5m in depth for foundation of poles, stay assembly etc and getting out in hard/ dense soil complete all as specified and directed.
Returning, filling in surplus spoil including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning to under ground cable providing with a layer of Sand 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge (Note : Punning thickness of 18 cm will be measured for payment purpose)
M&L for burnt bricks locally available, sub class 'B', laid flat for protection of under ground cable complete all as specified and directed at site.
Supply, laying , jointing and testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 185 sqmm 3.5 core, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts including cable gland of suitable sizes and aluminium lugs for connection, fixed as in repairs complete all as specified and directed. Note: Excavation, earthwork, sand cushioning, brick protection shall be measured & paid for separately.
All as per Item No 60 above but size 3.5 core 150 sqmm complete all as specified and directed.
All as per Item No 60 above but size 3.5 core 120 sqmm complete all as specified and directed.
All as per Item No 60 above but size 3.5 core 95 sqmm complete all as specified and directed.
All as per Item No 60 above but size 3.5 core 70 sqmm complete all as specified and directed.
All as per Item No 60 above but size 3.5 core 50 sqmm complete all as specified and directed.
All as per Item No 60 above but size 3.5 core 35 sqmm complete all as specified and directed.
All as per Item No 60 above but size 4 core 25 sqmm complete all as specified and directed.
All as per Item No 60 above but size 4 core 16 Sqmm complete all as specified and directed.
Taking out old unsc pole and Supplying, installation and errection in true vertical position steel tubular swaged welded pole, 9.0 metre long, conforming to IS-2713 part-II, type 410 SP-31, complete with cast iron/MS base plate 6mm thick and of size 300x300mm, finial taper, pole cap, bolts, nuts, washers & screws etc., pole made out of ERW Mild steel tubing tubing including holes of required Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint on exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three signal red colour bands at lower portion of exposed pole starting from plinth block , each band of 300mm height at 300mm spacing, painting pole No with black paint by stenciled letters/figures of 8cm height, complete all as specified and directed. Note: Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately in respected items.
Dismantling of cross arms, bracings, supports, clamps etc of MS fabricated complete with all accessories viz nut, bolts, washer etc. complete all as specified and directed.
M&L for cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers, welding , bending cold or hot, drilling holes for bolts,in any shape or sizes as indicated or directed and inclusive of one primer coat and two coats of alluminium paint complete all as specified and directed.
S&F in repair pin type insulator Porcelain, vitreous white/brown/green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100 mm height, 65 mm dia for 1100 volt grade, complete all as specified and directed.
S&F in repair for shackle type porcelain , vitreous white, brown or green insulator including galvanised mild steel straps, wahsers, insulator bolts, wahsers and nuts, as working pressure 1100 volts height in 100 mm maximum dia 115 mm section of straps in 31 x 5 mm dia of bolts 14 mm complete all as specified and directed.
S&F in repair stay assembly comprising of MS stay plate of size 30cmx30cmx6mm thick, stay rod with nuts 215cm long, 20mm dia, MS/GI stay bow 40 cm length with 2 Nos GI thimbles, galvanized stay wire standard size 7/4mm, loop insulation size 90mmx140mm clearance of hole 25.5 mm & other accessories all as per SSR Part-1, Plate No.1 including necessary MS clamps, excavation earth work & PCC work complete all as specified and directed.
Supply and fixing in repair galvonised stay strand, size 7/3.15 mm for connecting stay assembly with MS clamps on poles complete all as specified and directed.
Supply and fixing in repairs loop insulator porcelain, vitreous white/brown/green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, large size with overall dimensions 90mm x 140mm, clearance of hole 25.5 mm, Complete all as specified and directed.
S&F in repair cradle hexagonal , rectangular fabricated with GI wire 3.15 / 4 mm dia on existing OH line, complete all as specified and directed.
M&L for dismantling of ACSR conductors and removing from the site complete all as specified and directed.
Supply, stringing, streaching and binding with insulator, ACSR conductor of adequate size (Weasel /ferret/Mink) on LT Poles including providing of necessary jumpers, connecting all existing incoming and out going connections, trimming of trees approximately 2 mtr around conductor etc complete all as specified and directed.
Trimming of tree branches coming in proximity to LT over head lines and involved with over head lines where detected , over head lines to be cleared of tree branches atleast 2.5 Mtrs apart from ACSR conductor from all sides complete all as specified and directed. Note: Contactor is supposed to manage long wooden ladder atleast 32 feet height, rope and handsaw machine to clear the lines from tree branches having girth upto 6" dia at his own arrangement and cost.
M&L for Re-streching of loose over head ACSR conductor of any type including GI wire and repair of the broken conductors and adding new length( if required) in place of old and burnt conductor of any size on existing poles with proper sagging including winding with winding wire complete all as specified and directed. Note: Old conductor shall be reused where required for repairing broken length of conductor as directed by Engr-in-charge. Note: Five lines together will be measured as one span from pole to pole.
M&L for painting to steel poles including cross arms, 'V' brackets, 'D' clamps, nuts, bolts, complete including painting with five strips of 30cm each black and white paint in alternate strips from the base of pole upto 1.5mtr height complete, spray painting with two coat of synthetic enamel paint of first quality silver paint over a coat of red oxide primer after and including complete removal of old paint by scratching, rubbing complete all as specified and directed.
S&F in repair Earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 8 mm dia TMT bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified and directed. NOTE: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
S&F in repair Earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron wire 4 mm dia by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized iron pipe 15 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 8 mm dia TMT bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified and directed. NOTE: The unit rate includes earth wire and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
S&F in repair Single pointed air termination Aluminium rod 12mm dia, 300 mm long complete all as specified and directed.
S&F in repair Test point terminal block made of gun metal or phosphorous bronze of size 75x75 x 25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to GI pipe/ wall for protection of test point complete all as specified and directed.
S&F in repair galvanised iron tubing 'medium grade' with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete of size 50 mm bore, complete all as specified and directed.
S&F in repair aluminium strip 25 x 3.15mm with saddles and fixing screws, insulators rawl plugs etc for conductor for roof and fixed on wall upto test point, complete all as specified and directed.
S&F in repair Galvanized iron strip 32 x 6mm fixed with saddles & fixing screws, PVC dash fastners, insulators fixed from test point to earth on walls or burried in ground / drawn into hume pipe, complete all as specified and directed. NOTE : Excavation & earth work shall be measured and paid for seperately under relevant item of schedule.
S&F in repair galvanised iron tubing 'light grade' with all fittings and fixed to poles, walls etc. with flat iron clamps/ bolts/ nuts /washers or laid in floors/under roads complete of size 40 mm bore,complete all as specified and directed.
S&F in repair galvanised iron tubing 'light grade' with all fittings and fixed to poles, walls etc. with flat iron clamps /bolts /nuts /washers or laid in floors/under roads complete of size 80 mm bore, complete all as specified and directed.
M&L for painting of LT panel including preparation of old surfaces by scrapping old paint completely and applying two coats of super enameled paint over a coat of red oxide primer complete all as specified and directed.
S&F in repair MCCB, 3 pole, 63 Amps, 415 volts, fixed type with breaking capacity 16 KA Ics=75% Icu, complete all as specified and directed.
S&F in repair MCCB, 3 pole, 160 Amps, 415 volts, adjustable type, with breaking capacity 25 KA Ics=100% Icu, complete all as specified and directed.
S&F in repair MCCB, 3 pole, 200 Amps, 415 volts, adjustable type with breaking capacity 36 KA Ics=100% Icu, complete all as specified and directed.
S&F in repair MCCB, 3 pole, 250 Amps, 415 volts, adjustable type with breaking capacity 36 KA Ics=100% Icu, complete all as specified and directed.
S&F in repair MCCB, 3 pole, 400 Amps, 415 volts, adjustable type with breaking capacity 36 KA Ics=100% Icu, complete all as specified and directed.
S&F in repair aluminium thimble suitable for LT XLPE cable 185 sqmm size, complete all as specified and directed.
S&F in repair aluminium thimble suitable for LT XLPE cable 120 sqmm size, complete all as specified and directed.
S&F in repair aluminium thimble suitable for LT XLPE cable 95 sqmm size, complete all as specified and directed.
S&F in repair aluminium thimble suitable for LT XLPE cable 70 sqmm size, complete all as specified and directed.
S&F in repair aluminium thimble suitable for LT XLPE cable 50 sqmm size, complete all as specified and directed.
S&F in repair aluminium thimble suitable for LT XLPE cable 35 sqmm size, complete all as specified and directed.
S&F in repair aluminium thimble suitable for LT XLPE cable 25 sqmm size, complete all as specified and directed.
M&L for plain cement concrete 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for plain cement concrete (1:4:8) Type D-2 (using 40mm graded crushed stone aggregates) as in foundation for steel tubular poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed.
M&L for plain cement concrete (1:2:4) Type B-1 using 20 mm graded crushed stone aggregates, as in coping of steel tubular poles foundation for steel tubular poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed.
S&F in repair rubber insulating mat of size 2mx1mx2.5mm thick, ISI marked, complete all as specified and directed.
S&F in repair 1100 Volts grade heavy duty cable PVC insulated aluminum solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular, size of aluminum conductor 10 sq mm, complete all as specified and directed.
S&F in repair PVC spiral line spacer for LT over head line on 9.0 mtrs pole suitable for 2/3/4 wire, complete all as specified and directed.
Cutting through existing bituminous road /PCC/floor/approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish complete all as specified and directed.
S&F in repairr LT AB cable of size 3x35 sqmm twisted alround the bar messenger of 1x25 sqmm , made out of aluminium stranded circular compacted conductor, XLPE insulated all as per IS : 14255, IS 398 part-IV 7098 part-I including suspension clamp with eye hook at every 35 to 40 mtr span mounted on pole by means of MS clamp, complete all as specified & directed.
SHREE RAM CONSTRUCTION
ABINASHI ENTERPRISES
M/S PARSHOTAM KUMAR GUPTA
KRISHNA ENGINEERING ENTERPRISES
MS SHAM ARMYSTORE
M/S. Choudhary Dewan Chand And Sons
M/S Darshan Kumar
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .