Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹12.3 L+₹2.0 L (19.9%)Rejected-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L2 | Rejected-AOC Rejected | |
| 3 | L3₹13.9 L+₹3.7 L (35.7%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹14.0 L+₹3.7 L (36.3%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹29,000
Closing Date
5 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Bharatpur
GE Bharatpur
Provn of Defi Security light at Old and New Campus at RMS Dholpur
2021_MES_441988_1
8034/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
RMS Dholpur
Class E category b(I)
7 documents required · 7 mandatory
₹500
Yes
GE Bharatpur
₹29,000
Yes
9 Jul 2021
11 May 2021
7 Jun 2021
11 May 2021
5 Jun 2021
23 May 2021
60 days
Amount
Excavation in trenches not exc 1.5m wide and not exc, 1.5m depth for laying of cables in and getting out in hard/dens soil complete all as specified and as directed.
Returning & filling in including spearing, leveling watering and well ramming in layers not exc 25cm thick complete all as specified and as directed.
Removing of surplus soil not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed.
Supply and Spread dry unwashed machine sand for cable cushioning in trenches all as specified and directed. Note : Punned down thickness shall be considered for measurement complete all as specified and as directed. .
Supply and lay burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection complete all as specified and as directed.
M&L for PCC (1:2:4) type B1 with using 20mm graded aggregate as in coping concrete for poles/Stay wires/ LT panel boards and in addition where ever complete all as specified and as directed.
M&L for PCC (1:3:6) type C2 with using 40mm graded aggregate as in foundation and mass filling concrete for poles/stay wires/LT panel boards and in addition where ever complete all as specified and as directed.
Supply and lay GI tubing, light grade, 40 mm bore dia as cable protection fixed on walls/poles/laid in trenches complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated, screened PVC bedded, galvanised steel stripped or wire armoured electric cable heavy duty with stranded aluminium conductor , 1100Volts grade of size 16 Sqmm 4core complete all as specified and as directed.
Supplying and fixing steel tubular swaged poles with cast iron/ MS base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 5 Nos of 30cm wide circular bands alternate with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) ete complete all as specified and as directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
Supply & Fixing of LED based Street light , housing made up of pressure die cast aluminium Alloy with effective thermal mangement, sturdiness. The fixture should have a minimum system efficiency more of more than 80 lumen/Watt and a minimum system lumen output of not less than 7200 lumens and maximum system wattage 70Watts. The fixture shall have correlated colour temperature of atleast 5000K and a CRI of minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance. Ingress protection of IP 66 (lamp and gear Compartment and mechanical impact resistance rating ofIK >= 05. The fixture driver should have an operating voltage range 140-270 V, surge protection not less than 10KV, PF > 0.95 and THD < 15%. The fixture should comply to IEC 61000-3-2 ed 3.2 per harmonics IEC 61347-2-3 2006 in configuration with IEC 61347-1 ed 2.0, 2007 for electrical safety LM 79 and LM 80 test report needs to be submitted from NABL. The driver should have double phase protection. LED Light fitting should be suitable for ambient temperature from (-) 10 deg C to (+) 50 deg C as per IS 10322 and for EMI and LM 79 test reports , including making modification to existing street light bracket for fixing LED light if required , with suitable size clamp, nut bolts and washers as per site requirement complete all as specified and as directed by Engineer-in-Charge. (Note:- The manufacture of LED fitting shall give Guarantee for 2 Years from the date of installation). make - Havells cat pt No ENDURACITYLIN ERNEOSL70 WLED757 PASYBOTG or equivalent in Phillips, CG, Wipro and Syska as approved by GE
Supply & fixing of LED flood light fitting assymetrical type 200Watt pressure die cast housing with IP66 protection ,Efficient high output emitter LED for better distribution and applicable for area lighting.Make : CG ,Havells,and equivalent complete all as specified and as directed.
S & F bus bar chamber factory made of size 1MX1MX 0.4M using CRCA Sheet Steel of 3.15mm thick and epoxy powder coated and 4 Nos of Al (DMC) capicity 400 amp rating busbar supported of protection class IP-31,Standard conformity IEC 6043-IS-8623 with 200 Amp MCCB & plate with 35 KA bearing capacity with thermal megnetic rebease adjustable type , 440 Volts, 50 Hz, including angle iton stand made out of 50mmx50mmx5-6 mm with 0.75 mtr lingth fixed in PCC (Below ground 0.15 m and 0.10 m above ground level)complete all as specified and as directed.. Make of MCCB;-Havells/ L&T .
Supply and draw PVC insulated unsheathed aluminium conductor cable 4 sqmm 2 core from street light fitting to juction box to on poles of 9 mtrs and making nececessary connection both at junction box and street light fittings incl suitable size PVC conduit and fixing accessories complete all as specified and as directed. Note: 03 RM of 1Sqmm cable shal be measured as 01 meter length.
S&F Junction box made out of 2mm thick CRCA sheet of size 250mmx250mmx150mm with hinged door and locking arrangement including aluminum bus bar of size 25x3mm three phase & Neutral fixed on insulator, incl one No MCB SP 6 amps & painting a box with two coats of synthetic enamel paint over coat of red oxide primer complete all as specified and as directed..
Supply and fixing street light mounting bracket made out of GI pipe 40 mm dia med grade not less than with 1.8 m long in any shape with 2 nos of pole fitting clams made out of MS flat of size 40X40 x 6 mm angle and nuts and bolts complete all as specified and as directed..
PD GUPTA AND COMPANY
M/S S.S Traders
S D POWER SOL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .