| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC 12 1 1 PUDHUSAMPALLI RAMAN NAGAR POST METTUR DAM 636 403 | METTUR DAM | SALEM | TAMIL NADU | 636403 | ₹4.0 L Quoted ₹3.8 L | L1 | Accepted-AOC L1 |
| Sl No | Description | Qty | Unit | V PALANIVELU CONTRACTOR L1 |
|---|---|---|---|---|
| 1.00 | Charges for Removing, cleaning, transporting, servicing, air leak and operation checking, refixing and checking of Retractor Assembly of HEA Ignitors and power Cylinders. | 12 | Nos | 3,075 ₹36,900 |
| 2.00 | Charges for disconnecting the connectors of the flame scanners, removing from the Boiler guide pipe assembly, transporting to work bench, dismantling & Reassembling the scanner head assembly from scanners, removing, cleaning & refixing the lenses, servicing and checking of flame scanners. | 32 | Nos | 1,100 ₹35,200 |
| 3.00 | Charges for removing, transporting, cleaning and refixing after calibration local pressure Gauges / temperature gauges. | 100 | Nos | 385 ₹38,500 |
| 4.00 | Charges for Removal of Pressure/DP temperature switches and refixing them after calibration | 44 | Nos | 385 ₹16,940 |
| 5.00 | Charges for dismantling, transporting, cleaning and refixing them after calibration of Pressure Transmitters and Temperature Transmitters. | 7 | Nos | 385 ₹2,695 |
| 6.00 | Charges for removing from field, transporting to LAB, cleaning, calibrating, and refixing after calibration of air regulator with gauges. | 48 | Nos | 385 ₹18,480 |
| 7.00 | Charges for removing from field, transporting to LAB, cleaning, refixing after calibration of I/P converter. | 23 | Nos | 385 ₹8,855 |
| 8.00 | Charges for opening and cleaning of 1/2" impulse line and catch pot in mills, Flue gas, primary and secondary air paths. | 26 | Nos | 350 ₹9,100 |
| 9.00 | Charges for releasing of Electronic cards, cleaning of panels & reinserting the cards, terminal tightness checking of FSSS DCS, Feeder, HYDRASTEP, Flame scanner, 110 V AC & 220 V DC distribution panels and charger Panels. | 25 | Nos | 900 ₹22,500 |
| 10.00 | Charges for removing, cleaning, servicing, refixing and checking of SADC positioners. | 48 | Nos | 920 ₹44,160 |
Tender Value
Refer Docs
EMD Value
₹3,600
Closing Date
21 Aug 2025, 2:00 pmClosed
CHIEF ENGINEER/MTPS-I
CHIEF ENGINEER MTPS-I METTUR DAM
MTPS-I ES Circle CI FSSS 34 Annual overhauling of retractor assembly of HEA ignitors, flame scanners, Pr. Gauges switches, DP switches, Temp gauges switches, Transmitters, SADC positioners, HAG solinoid valves etc in Unit-III for the year 2025-20
2025_EB_589381_1
CE-MTPSI-SE-ES-CI-OT63-25-26
Open Tender
Electrical Works
20 days
MTPS-I/METTURDAM
AS PER TENDER SPECIFICATION
4 documents required · 4 mandatory
₹0
₹3,600
Yes
9 Mar 2026
6 Aug 2025
22 Aug 2025
6 Aug 2025
21 Aug 2025
6 Aug 2025
Amount
Charges for Removing, cleaning, transporting, servicing, air leak and operation checking, refixing and checking of Retractor Assembly of HEA Ignitors and power Cylinders.
Charges for disconnecting the connectors of the flame scanners, removing from the Boiler guide pipe assembly, transporting to work bench, dismantling & Reassembling the scanner head assembly from scanners, removing, cleaning & refixing the lenses, servicing and checking of flame scanners.
Charges for removing, transporting, cleaning and refixing after calibration local pressure Gauges / temperature gauges.
Charges for Removal of Pressure/DP temperature switches and refixing them after calibration
Charges for dismantling, transporting, cleaning and refixing them after calibration of Pressure Transmitters and Temperature Transmitters.
Charges for removing from field, transporting to LAB, cleaning, calibrating, and refixing after calibration of air regulator with gauges.
Charges for removing from field, transporting to LAB, cleaning, refixing after calibration of I/P converter.
Charges for opening and cleaning of 1/2" impulse line and catch pot in mills, Flue gas, primary and secondary air paths.
Charges for releasing of Electronic cards, cleaning of panels & reinserting the cards, terminal tightness checking of FSSS DCS, Feeder, HYDRASTEP, Flame scanner, 110 V AC & 220 V DC distribution panels and charger Panels.
Charges for removing, cleaning, servicing, refixing and checking of SADC positioners.
Charges for removing the terminal connections, Replacing the broken Terminal Blocks and reconnecting the terminal connections and checking in Various Junction boxes at Boiler and mill area.
Charges for removing, cleaning solenoid valves, air filter cum lubricator & the airlines and replacing the ‘O’ rings in the solenoid valves and refixing the solenoid valves, air filter cum lubricator & the airlines in the HAGs.
Charges for cutting and welding of take-off catch pot in mills, flue gas, primary and secondary air path.
Charges for single point cutting and welding of pipe size ½” impulse lines of mills, flue gas, primary and secondary air path including cost of gas, welding electrodes & consumables such as cotton waste, hacksaw blade, etc.
Charges for painting with 2 coats for any electrical equipments. (Ignitors 12 Nos x 0.95=11.4 mtr² and SADC 48 Nos x0.9=43.2 mtr²)
Charges for Cutting , welding, shifting, rearranging and tubing of 3 Nos. of Seal air to Mill DP Adequate, Low and Mill Bowl DP High in 4th meter location.(As per Data sheet No-6)
Various sizes of U seal (84 Nos.) for work Sl. no.1(As per Data sheet-1)
Lens (40 Nos.) for work Sl. no.2 (Plano Convex lens : 20 Nos. & Plain lens : 20 Nos.)(As per Data sheet-7)
Bellows for work Sl. no.10
Various sizes of ‘O’ rings (60 Nos.) for work Sl. no.12(As per Data sheet-2)
F Ring (5 x 9.5 x 1.3mm) for work Sl. no.12
Various sizes of U seal (12 Nos.) for work Sl. no.12(As per Data sheet-3)
Metallic Paint for work Sl. No.15(As per Data sheet-4)
Brushes for Painting. For work Sl. No.15
Enamel Thinner for work Sl. No.15
SS Tubes (3/8 inch O/D*1.65mm thickness) for work Sl. no: 16
SS Connector (3/8 inch OD *½ inch NPT male SS) for work Sl. no: 16
Rust Remover (CRC) for work Sl. no: 1,2,10 & 11 (500 ml)
Hackshaw Blade for work Sl. no: 13
Nada for work Sl. no: 10
2.5 Sq.mm Elmax Terminal Block for work Sl. no: 11
Cost of Consumables such as 2.5 mm welding rod electrode, Dungry cloth, Cotton Waste, Petrol, Teflon Tape, PVC Insulation tape & Dentrite.(As per Data sheet-5)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid