Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC A 69 FIEE COMPLEX PHASE II OKHLA INDUSTRIAL AREA PHASE II NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | ₹35.5 L Quoted ₹35.7 L | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹39.9 L+₹4.1 L (11.5%)Rejected-Finance PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | ₹39.9 L+₹4.1 L (11.5%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹41.8 L+₹6.0 L (16.9%)Rejected-Finance 8 51 PLOT NO 6 LIC COLONY SUJATA NAGAR PENDURTHY MANDAL VISAKHAPATNAM 530042 AP | 530042 | ₹41.8 L+₹6.0 L (16.9%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹42.5 L+₹6.7 L (18.8%)Rejected-Finance 95 A GOVIND NAGAR RACE COURSE OPP GURUDWARA DEHRADUN UK PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹42.5 L+₹6.7 L (18.8%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹47.6 L+₹11.9 L (33.2%)Rejected-Finance N A | ₹47.6 L+₹11.9 L (33.2%) | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | SKYLIGHT INNOVATIONS L5 | Singh Associates L2 | M/S Manmohan Singh Anand L4 | HFM Solar Power Limited L1 | LEOENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation and interconnection of 110 NOS. mono crystalline high efficiency Cell Glass 3.2 MM thick (Solar PV module Mono Crystalline) />132 Cell Single glass multicrystalline 4mm thick Solar Pv module with AR Coating with Power output Capacity of each solar PV module >550W. Total Solar PV module arrays Capacity a set of (60kWp) at STC. The Solar Panels should Comply as per IEC 61215 and IEC 61730 standard. DC cable/wire of suitable size up to 2Mt/solar pv module with solar pv connectors (MC4)/ couplers etc. shall be included in this item. efficiency of solar pv modules should be equal or more than 20%. IP68 Weatherproof complete all asspecified and directed. | 110 | Each | 17,500 ₹19,25,000 | 12,000 ₹13,20,000 | 18,888 ₹20,77,680 | 15,260 ₹16,78,600 | 11,440 ₹12,58,400 Lowest |
| 2.00 | S & F high utility Data Logger and real time sensor interface with Online Monitoring Portal Complete for monitoring and assessment on utility scale of PV plant complete all as specified and directed by engineer in charge. | 1 | Each Job | 2,50,000 ₹2,50,000 | 20,000 ₹20,000 Lowest | 55,555 ₹55,555 | 75,000 ₹75,000 | 45,000 ₹45,000 |
| 3.00 | Material Labour & Design HDGI Structure for 60kWP PV Module foundation for mounting the structure should be as per defined standards which clearly states the Load Bearing Capacity & other relevant parameters for foundation design (As per IS 6403 / 456 / 4091 / 875).
ii. Grade of raw material to be used for mounting the structures so that it complies the defined wind loading conditions (As per IS 875 - III) should be referred as follows (IS 2062 – for angles and channels, IS 1079 – for sheet, IS 1161 & 1239 for round pipes, IS 4923 for rectangular and square hollow section)
iii. Test reports for the raw material should be as per IS 1852 / 808 / 2062 / 1079 / 811.
iv. In process inspection report as per approved drawing & tolerance should be as per IS 7215.
v. For ascertaining proper welding of structure part following should be referred:
a. D.P. Test (Pin Hole / Crack) (IS 822)
b. Weld wire grade should be of grade (ER 70 S - 6)
vi. For ascertaining hot dip galvanizing of fabricated structure following should be referred: -
a. Min coating required should be as per IS 4759 & EN 1461.
b. Testing of galvanized material
▪ Pierce Test (IS 2633)
▪ Mass of Zinc (IS 6745)
▪ Adhesion Test (IS 2629)
▪ CuSO4 Test (IS 2633)
▪ Superior High-Grade Zinc Ingot should be of 99.999% purity (IS 209)
(Preferably Hindustan Zinc Limited or Equivalent).
vii.Foundation Hardware – If using foundation bolt in foundation then it should be
as per IS 5624. | 1 | Each Job | 3,50,000 ₹3,50,000 | 5,78,500 ₹5,78,500 | 3,33,333 ₹3,33,333 | 90,000 ₹90,000 Lowest | 3,25,000 ₹3,25,000 |
| 3.01Support array/module mounting structures, mounting Clips shall be manufactured with Hot dip galvanized steel angles & channels; spray galvanized to IS 1477 Part -1 with thickness of 90 microns or aluminium alloy as per IS 5905. All fasteners shall be of Stainless steel (SS 304). MMS having adequate strength & appropriate design and shall be suitable to accommodate 110 No. of Solar Panels which can withstand the load of modules and wind velocity of 150Km/hr, complete with civil work removable concrete ballast made of pre- fabricated PCC (1:2:4) M15 and other required hardware. All solar panels must be accessible from the top for cleaning and from the bottom for access to the module junction box. | ||||||||
| 4.00 | Material and labour for Solar Inverter MPPT Based Grid Tied Solar Inverter with 60 kW X 1 Nos rating with maximum DC Input Voltage 1000V , MPPT range from 200V to 1000V AC output 310-480V, 3 Phase, 4 wire, 50Hz, with inbuilt protection of AC high/low voltage, high/low frequency, DC & AC surge protection device (SPD) class 2 as per IEC 60364-5-53, anti-islanding protection as per VDE 0126-1-1, IEC 60255.5/IEC 60255.27. and LCD display with all parameter like output power(W), energy (Wh), DC voltage & current, AC voltage, current & frequency, operation hours etc. complying to standards as per IEC62109, EN61000-6-2, EN61000-6-3, EN61000-3-12, EN61000-3-11. Invertor has facility RS 485/RS232/RJ45 port for communication interface and its enclosure should be IP 54 for Indoor and IP 65 for outdoor installation. Invertor efficiency should be more than 96%. | 1 | Each | 2,60,000 ₹2,60,000 | 2,85,000 ₹2,85,000 | 2,66,666 ₹2,66,666 | 2,40,000 ₹2,40,000 | 1,57,000 ₹1,57,000 Lowest |
| 5.00 | Supply & installation of DCDB, DC combiner box/Array Junction Box made out of the thermoplastic IP65 protected DIN rail mounting type of following size for interconnection of DC cable of the solar module arrays & DC outgoing cable to DC distribution box complete with termination with cu lugs/ferrule /connectors (MC4) and fixing accessories as required.
Outdoor IP 65 Enclosure – Tribox/Fibox/Equivalent – 560mm X 380mm X 130mm
Input Postive & Negative Fuse 15A – Mersen/Elmex/Havells/Equivalent – 8 nos
Solar Output Terminal Block – Elmex/Salzer/Pheonix/Equivalent – 8 nos | 1 | Each | 32,000 ₹32,000 | 44,000 ₹44,000 | 13,333 ₹13,333 Lowest | 35,000 ₹35,000 | 45,000 ₹45,000 |
| 6.00 | Supply & installation of AC distribution box made out of the thermoplastic IP65 protected DIN rail mounting and front lid transparent type of following size with Phase indication LED lamp, busbar, earth link terminal etc. complete with all fixing accessories as required.
Metal Enclosure 600*400*180 MM Metal Box With IP 65 Rating
MCCB 100A FP 10KA , Spreder 100A FP, Phonix SPD 4 Pole, Metal Gland Etc, Spreder 100A FP, Busbar Supportor 100A, RYB Indicator
Cable 25Sq.mm Copper Flexible, Connectwell terminal Block, Earthing Termianl Green & Yellow Color, Double Compression Gland (Brass), Standard Indicating Sticker
Multi function Meter :
Instantaneous RMS values
Current: Average line current of 3-phase, per-phase, and calculated neutral current
Voltage: Average voltage of L-L, L-N parameters, and per-phase
Frequency Any available line: Real, reactive, and apparent power,
Total and per-phase value, Displacement power factor, Average and per-phase signed, four-quadrant
True power factor, Average and per-phase signed, four-quadrant
Demand values
Current average: Present, Last, Predicted, Peak, and Peak Date Time
Active power: Present, Last, Predicted, Peak, and Peak Date Time
Reactive power: Present, Last, Predicted, Peak, and Peak Date Time
Apparent power: Present, Last, Predicted, Peak, and Peak Date Time
Demand sync methods: Thermal, Timed, Command Sync, and Clocked Sync
Demand calculation mode: Sliding, fixed and rolling block | 1 | Each | 1,18,000 ₹1,18,000 | 68,500 ₹68,500 | 13,333 ₹13,333 Lowest | 50,000 ₹50,000 | 65,000 ₹65,000 |
| 7.00 | Supplying and laying of following sizes of XLPE insulated and sheathed, UV stablished/protected Single core flexible copper conductor DC cable layed in HDPE conduit pipe suitable for outdoor installation complete with termination with tinned copper end-ferrules, special connector (MC4), gland etc. as required. All DC cable shall be supplied confirming to IEC 60502 / IS 1554 voltage rating 1500 V grade.
6 SQ.MM. single core flexible Copper UV protected XLPE cable.
Electron beam cross linked compound
UV, Ozone, Temperature & Hydrolysis resistant, Flame Retardant, Low Smoke, Excellent Encapsulation Very long / Service life > 25
Standards / Material Properties
Fire performance : IEC 60332-1-2
Smoke emission : IEC 61034/ EN 50268-2
Halogen Free: EN 50267-2-1/-2, IEC 60754-2
Toxicity: EN 50305, ITC – Index <3
Ozone Resistant : EN50396
Weathering UV: HD 605/A1 or DIN 53367
Approvals : EN 50618; H1Z2Z2-k | 2,850 | RM | 67 ₹1,90,950 Lowest | 70 ₹1,99,500 | 99 ₹2,82,150 | 80 ₹2,28,000 | 135 ₹3,84,750 |
| 8.00 | Supplying and laying of following sizes of XLPE insulated and PVC sheathed Single/multi core armoured copper conductor AC cable layed in wall/ceiling complete with fixing accessories like clamp, saddle, pvc slip screws etc. as required. All AC cable shall be supplied confirming to IEC 60227 / IS 694 voltage rating 1100 V grade.
4 Core X 95 SQ. MM., Aluminum Conductor, XLPE Insulated, Un-armoured / GS
Round wire Armoured / GS Flat Strip Armoured, PVC Outer Sheath Cable
conforming to IS 7098 Part-1 with up to date amendment.
• Voltage Rating : 1100 Volts
• Temperature Rating : -40 to +90 Deg.C
• UV Resistance
• RoHS Compliant
Technical Specifications
Conductor Aluminum Conductor IS 8130
Insulation XLPE IS 7098 Part-1
Insulation Colour Red , Yellow , Blue & Black IS 7098 Part-1
Inner Sheath Extruded PVC Type ST-1, Extruded HR PVC Type ST-2 IS 5831
Armouring (as applicable) :GS Round Wire, GS Flat Strip IS 8130
Outer Sheath Extruded PVC Type ST-1, Extruded HR PVC Type ST-2 IS 5831
Colour Black or optional
Special Properties: Flame Retardant, Flame Retardant low smoke, Flame Retardant low smoke zero halogen | 725 | RM | 800 ₹5,80,000 | 450 ₹3,26,250 | 699 ₹5,06,775 | 180 ₹1,30,500 Lowest | 840 ₹6,09,000 |
| 9.00 | Supplying and making 1100 V, end termination of size 4 core x 95 sqm. Armoured Al conductor XLPE cable. of XLPE insulated and PVC sheathed Single/multi core armoured copper conductor AC cable termination with tinned copper end-ferrules/lugs and single compression cable gland, pvc tap as required. | 6 | Each | 750 ₹4,500 | 3,500 ₹21,000 | 2,222 ₹13,332 | 225 ₹1,350 Lowest | 6,500 ₹39,000 |
Tender Value
₹43.6 L
EMD Value
₹87,280
Closing Date
17 Mar 2026, 6:00 pmClosed
Col L Suvarna CWE
HQ CWE (AF) Gurgaon, Old Palam Road, Delhi Cantt-10
PROVN OF ROOF TOP SOLAR SYSTEM IN TECH AREA OF AF STN BASANT NAGAR IN AOR OF GE (AF) FARIDABAD
2026_MES_754073_1
CWE/GGN/FT-70/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
At AF STN Basant Nagar
As per NIT
9 documents required · 9 mandatory
₹500
GE AF Faridabad
₹87,280
Yes
17 Jun 2026
24 Feb 2026
19 Mar 2026
24 Feb 2026
17 Mar 2026
11 Mar 2026
24 Feb 2026 - 10 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation and interconnection of 110 NOS. mono crystalline high efficiency Cell Glass 3.2 MM thick (Solar PV module Mono Crystalline) />132 Cell Single glass multicrystalline 4mm thick Solar Pv module with AR Coating with Power output Capacity of each solar PV module >550W. Total Solar PV module arrays Capacity a set of (60kWp) at STC. The Solar Panels should Comply as per IEC 61215 and IEC 61730 standard. DC cable/wire of suitable size up to 2Mt/solar pv module with solar pv connectors (MC4)/ couplers etc. shall be included in this item. efficiency of solar pv modules should be equal or more than 20%. IP68 Weatherproof complete all asspecified and directed. | 110 | Each | - | - |
| 2 | S & F high utility Data Logger and real time sensor interface with Online Monitoring Portal Complete for monitoring and assessment on utility scale of PV plant complete all as specified and directed by engineer in charge. | 1 | Each Job | - | - |
| 3 | Material Labour & Design HDGI Structure for 60kWP PV Module foundation for mounting the structure should be as per defined standards which clearly states the Load Bearing Capacity & other relevant parameters for foundation design (As per IS 6403 / 456 / 4091 / 875).
ii. Grade of raw material to be used for mounting the structures so that it complies the defined wind loading conditions (As per IS 875 - III) should be referred as follows (IS 2062 – for angles and channels, IS 1079 – for sheet, IS 1161 & 1239 for round pipes, IS 4923 for rectangular and square hollow section)
iii. Test reports for the raw material should be as per IS 1852 / 808 / 2062 / 1079 / 811.
iv. In process inspection report as per approved drawing & tolerance should be as per IS 7215.
v. For ascertaining proper welding of structure part following should be referred:
a. D.P. Test (Pin Hole / Crack) (IS 822)
b. Weld wire grade should be of grade (ER 70 S - 6)
vi. For ascertaining hot dip galvanizing of fabricated structure following should be referred: -
a. Min coating required should be as per IS 4759 & EN 1461.
b. Testing of galvanized material
▪ Pierce Test (IS 2633)
▪ Mass of Zinc (IS 6745)
▪ Adhesion Test (IS 2629)
▪ CuSO4 Test (IS 2633)
▪ Superior High-Grade Zinc Ingot should be of 99.999% purity (IS 209)
(Preferably Hindustan Zinc Limited or Equivalent).
vii.Foundation Hardware – If using foundation bolt in foundation then it should be
as per IS 5624. | 1 | Each Job | - | - |
| 3.01 | Support array/module mounting structures, mounting Clips shall be manufactured with Hot dip galvanized steel angles & channels; spray galvanized to IS 1477 Part -1 with thickness of 90 microns or aluminium alloy as per IS 5905. All fasteners shall be of Stainless steel (SS 304). MMS having adequate strength & appropriate design and shall be suitable to accommodate 110 No. of Solar Panels which can withstand the load of modules and wind velocity of 150Km/hr, complete with civil work removable concrete ballast made of pre- fabricated PCC (1:2:4) M15 and other required hardware. All solar panels must be accessible from the top for cleaning and from the bottom for access to the module junction box. | - | - | - | - |
| 4 | Material and labour for Solar Inverter MPPT Based Grid Tied Solar Inverter with 60 kW X 1 Nos rating with maximum DC Input Voltage 1000V , MPPT range from 200V to 1000V AC output 310-480V, 3 Phase, 4 wire, 50Hz, with inbuilt protection of AC high/low voltage, high/low frequency, DC & AC surge protection device (SPD) class 2 as per IEC 60364-5-53, anti-islanding protection as per VDE 0126-1-1, IEC 60255.5/IEC 60255.27. and LCD display with all parameter like output power(W), energy (Wh), DC voltage & current, AC voltage, current & frequency, operation hours etc. complying to standards as per IEC62109, EN61000-6-2, EN61000-6-3, EN61000-3-12, EN61000-3-11. Invertor has facility RS 485/RS232/RJ45 port for communication interface and its enclosure should be IP 54 for Indoor and IP 65 for outdoor installation. Invertor efficiency should be more than 96%. | 1 | Each | - | - |
| 5 | Supply & installation of DCDB, DC combiner box/Array Junction Box made out of the thermoplastic IP65 protected DIN rail mounting type of following size for interconnection of DC cable of the solar module arrays & DC outgoing cable to DC distribution box complete with termination with cu lugs/ferrule /connectors (MC4) and fixing accessories as required.
Outdoor IP 65 Enclosure – Tribox/Fibox/Equivalent – 560mm X 380mm X 130mm
Input Postive & Negative Fuse 15A – Mersen/Elmex/Havells/Equivalent – 8 nos
Solar Output Terminal Block – Elmex/Salzer/Pheonix/Equivalent – 8 nos | 1 | Each | - | - |
| 6 | Supply & installation of AC distribution box made out of the thermoplastic IP65 protected DIN rail mounting and front lid transparent type of following size with Phase indication LED lamp, busbar, earth link terminal etc. complete with all fixing accessories as required.
Metal Enclosure 600*400*180 MM Metal Box With IP 65 Rating
MCCB 100A FP 10KA , Spreder 100A FP, Phonix SPD 4 Pole, Metal Gland Etc, Spreder 100A FP, Busbar Supportor 100A, RYB Indicator
Cable 25Sq.mm Copper Flexible, Connectwell terminal Block, Earthing Termianl Green & Yellow Color, Double Compression Gland (Brass), Standard Indicating Sticker
Multi function Meter :
Instantaneous RMS values
Current: Average line current of 3-phase, per-phase, and calculated neutral current
Voltage: Average voltage of L-L, L-N parameters, and per-phase
Frequency Any available line: Real, reactive, and apparent power,
Total and per-phase value, Displacement power factor, Average and per-phase signed, four-quadrant
True power factor, Average and per-phase signed, four-quadrant
Demand values
Current average: Present, Last, Predicted, Peak, and Peak Date Time
Active power: Present, Last, Predicted, Peak, and Peak Date Time
Reactive power: Present, Last, Predicted, Peak, and Peak Date Time
Apparent power: Present, Last, Predicted, Peak, and Peak Date Time
Demand sync methods: Thermal, Timed, Command Sync, and Clocked Sync
Demand calculation mode: Sliding, fixed and rolling block | 1 | Each | - | - |
| 7 | Supplying and laying of following sizes of XLPE insulated and sheathed, UV stablished/protected Single core flexible copper conductor DC cable layed in HDPE conduit pipe suitable for outdoor installation complete with termination with tinned copper end-ferrules, special connector (MC4), gland etc. as required. All DC cable shall be supplied confirming to IEC 60502 / IS 1554 voltage rating 1500 V grade.
6 SQ.MM. single core flexible Copper UV protected XLPE cable.
Electron beam cross linked compound
UV, Ozone, Temperature & Hydrolysis resistant, Flame Retardant, Low Smoke, Excellent Encapsulation Very long / Service life > 25
Standards / Material Properties
Fire performance : IEC 60332-1-2
Smoke emission : IEC 61034/ EN 50268-2
Halogen Free: EN 50267-2-1/-2, IEC 60754-2
Toxicity: EN 50305, ITC – Index <3
Ozone Resistant : EN50396
Weathering UV: HD 605/A1 or DIN 53367
Approvals : EN 50618; H1Z2Z2-k | 2,850 | RM | - | - |
| 8 | Supplying and laying of following sizes of XLPE insulated and PVC sheathed Single/multi core armoured copper conductor AC cable layed in wall/ceiling complete with fixing accessories like clamp, saddle, pvc slip screws etc. as required. All AC cable shall be supplied confirming to IEC 60227 / IS 694 voltage rating 1100 V grade.
4 Core X 95 SQ. MM., Aluminum Conductor, XLPE Insulated, Un-armoured / GS
Round wire Armoured / GS Flat Strip Armoured, PVC Outer Sheath Cable
conforming to IS 7098 Part-1 with up to date amendment.
• Voltage Rating : 1100 Volts
• Temperature Rating : -40 to +90 Deg.C
• UV Resistance
• RoHS Compliant
Technical Specifications
Conductor Aluminum Conductor IS 8130
Insulation XLPE IS 7098 Part-1
Insulation Colour Red , Yellow , Blue & Black IS 7098 Part-1
Inner Sheath Extruded PVC Type ST-1, Extruded HR PVC Type ST-2 IS 5831
Armouring (as applicable) :GS Round Wire, GS Flat Strip IS 8130
Outer Sheath Extruded PVC Type ST-1, Extruded HR PVC Type ST-2 IS 5831
Colour Black or optional
Special Properties: Flame Retardant, Flame Retardant low smoke, Flame Retardant low smoke zero halogen | 725 | RM | - | - |
| 9 | Supplying and making 1100 V, end termination of size 4 core x 95 sqm. Armoured Al conductor XLPE cable. of XLPE insulated and PVC sheathed Single/multi core armoured copper conductor AC cable termination with tinned copper end-ferrules/lugs and single compression cable gland, pvc tap as required. | 6 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
BOQ_844610.xls
BOQ • 0.30 MB
TenderdocumentsFT70.pdf
Tender Documents • 1.19 MB
CorridocusFT70_Tendoc.pdf
PDF • 0.78 MB
corridtFT70date.pdf
PDF • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .