| Sl No | Description | Qty | Unit | M/S JSCC L1 | M/S MOHD ALYASS BHAT GOVT CONTRACTOR L2 | M/s Kanhaiya Constructions L3 |
|---|---|---|---|---|---|---|
| 1.00 | Demolishing cement concrete in 1:3:6 or richer mix manually / by mechanical means including disposal of material within 50 Mtrs lead. | 245 | Cum | - | - | - |
| 2.00 | Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 Mtrs lead (in cement mortar). | 28 | Cum | - | - | - |
| 3.00 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead of area of 3 sq. metres and below | 13 | Each | - | - | - |
| 4.00 | Dismantling wood work in frames, trusses, purlins and rafters upto 10 metres span and 5 metres height including stacking the material within 50 metres lead of sectional area 40 square centimetres and above. | 0.32 | Cum | - | - | - |
| 5.00 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) excluding cost of centering and shuttering. All work upto plinth level. | 59 | Cum | - | - | - |
| 6.00 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded crushed stone aggregate 20mm nominal size). | 111 | Cum | - | - | - |
| 7.00 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigment etc. complete (size of tile 60x60cm). | 1,483 | Sqm | - | - | - |
| 8.00 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | 3,658 | Sqm | - | - | - |
| 9.00 | Providing and applying white cement based putty of average thickness 2mm, of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete. | 7,246 | Sqm | - | - | - |
| 10.00 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content with water thinnable cement primer on wall surface having VOC content less than 50gms/litre. | 3,710 | Sqm | - | - | - |
Tender Value
₹2.0 Cr
EMD Value
₹3.9 L
Closing Date
11 Jun 2020, 4:00 pmClosed
Er Parvez Malik
Executive Engineer PWD RandB Const Divn No I Jammu
Please refer to BOQ
2020_PWDJK_97331_1
e-NIT No CD-I/01 of 2020-21 Dated 27-05-2020
Open Tender
Civil Works
Item Rate
90 days
Govt. Polytechnic College Bikram Chowk Jammu
Please refer to NIT/SBD
3 documents required · 3 mandatory
₹6,000
Yes
Executive Engineer PWD RandB Const Divn No I Jammu
₹3.9 L
Yes
Jammu
19 Jun 2020
28 May 2020
12 Jun 2020
28 May 2020
11 Jun 2020
28 May 2020
4 Jun 2020
Amount
Demolishing cement concrete in 1:3:6 or richer mix manually / by mechanical means including disposal of material within 50 Mtrs lead.
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 Mtrs lead (in cement mortar).
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead of area of 3 sq. metres and below
Dismantling wood work in frames, trusses, purlins and rafters upto 10 metres span and 5 metres height including stacking the material within 50 metres lead of sectional area 40 square centimetres and above.
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) excluding cost of centering and shuttering. All work upto plinth level.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded crushed stone aggregate 20mm nominal size).
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigment etc. complete (size of tile 60x60cm).
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Providing and applying white cement based putty of average thickness 2mm, of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content with water thinnable cement primer on wall surface having VOC content less than 50gms/litre.
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats.
Painting with synthetic enamel paint of approved brand and manufacture to give and even shade two or more coats on new work.
Brick work with common burnt clay F.P.S (non modular) bricks of class designation 75 in foundation & plinth in cement mortar 1:6 (1 cement : 6 coarse sand).
Extra for brick work in super structure above plinth level upto floor V-level.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under including cutting in the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead with cement mortar 1:4 (1 cement: 4 coarse sand).
Finishing wall with acrylic smooth exterior paint of required shade on new work (two or more coats applied @ 1.67 ltr. /10sqm over and including base coat of water proofing cement paint applied @ 2.20kg/10sqm)
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of pproved texture spintone/cosmos I Hexa or equivalent of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main T runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross 'T" of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main'T' at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on Perimeter wall angle pre-coated steelsize (24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws@ 230 mm intervaland laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture (Spin~one I Cosmos/hexa) in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings,fiXtU(eS, smoke detectors etc., wherever required. Main T runners to be suspended from ceiling using G. I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.l. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main 'T , bottom exposed with 24 mm of all T-sections shall be prepainted with polyster baked paint, for all heights, as per specifications, drawings and as directed by engineer-incharge.Note :-Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non -combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/m 0 KC.
Providing and fixing flat pressed 31ayer medium density particle board or graded particle board (Grade I) IS: 3087 marked, in ceiling with necessary nails etc. complete (frame work to be paid separately) 12 mm thick.
Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50mt. lead.
Demolishing mud phaska in terracing and disposal of material within 50 mtr. lead.
Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc. consisting of (a) applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks / brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining was upto 300mm height including rounding of junction of walls and slaps. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg / sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. (iv) Finishing the surface with 20mm thick joint less cement mortar of mix 1: 4 admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fiber cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm / sq 3mm deep. (e) The whole terrace so finished shall be flooded with water far a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer-in-charge. With average thickness of 120mm and minimum thickness at khurras as 65mm.
Making khurras 45 x 45cm with average minimum thickness of 5cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1m x 1m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete.
Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 1 0 mm dia double threaded 6.8 grade (yield strength 480 N/mm2) counter sunk head, comprising of 10m dia ployamide PA 6 grade sieve sleeve including drilling of hole in frame , concrete masonary etc. as per direction of Engineer-in-charge. 10x140mm.
Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion. Single socketed pipes of 110mm diameter.
Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion. Single socketed pipes of 160mm diameter.
Providing and fixing on wall face unplastised – PVC moulded fittings / accessories for unplasticised – Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion. Bend 87.5 Degree.110mm bend.
15mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement : 4 fine sand).
12mm cement plaster of mix 1:4 (1 cement : 4 fine sand).
Steel work in built up tubular round, square or rectangular including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer including welding and bolting with special shaped washers etc. complete. Hot finished welded type tube.
Providing and fixing partition upto ceiling height consisting of G. I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G. I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of framework by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete. 75mm overall thickness partitions with 12.5 thick double skin fire rated board confirming to IS: 2095 (Part I).
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z. sections and other sections of approved make conforming to IS : 733 and IS : 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber Ineoprene .. gasket felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing I panelling, C.P. brass I stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) Polyester powder coated aluminium (minimum thickness of polyester powder coated 50 microns).
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z. sections and other sections of approved make conforming to IS : 733 and IS : 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber Ineoprene .. gasket felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing I panelling, C.P. brass I stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) Polyester powder coated aluminium (minimum thickness of polyester powder coated 50 microns).
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. 200x10 mm.
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete. 125x70x4 mm (ordinary type).
Providinq and fixing bright finished brass 100 mm mortice latch and lock lSI marked with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles with necessary screws etc. complete, best make of approved quality.
Providing and fixing aluminium hanging floor door stopper lSI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete Twin rubber stopper.
Providing and fixing 50 cm long aluminium kicking plate of size 1 00x3.15 mm, anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade with necessary screws etc. complete.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, having brand logo em,possed on the body/plate with double spring mechanism and door weight upto 125 kg for doors including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot" and single piece M.S. sheet outer box with slide plate etc. complet as per the direction of Engineer-in-charge. With brass cover plate minimum 1.25 mm thickness.
Providing and fixing 12mm thick prelaminated particle boardflat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-l type-11) in panelling fixed in aluminium doors, windows shutters and partition frames with C. P. brass I stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides.
Providing and fixing aluminium handles ISI marked (anodized anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 125mm.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level in 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate) 40mm nominal size crushed.
Providing and laying in position cement concrete of specified grade 1:3:6 grade (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20mm nominal size) excluding the cost of centering and shuttering. All work upto plinth level.
Reinforced cement concrete work in Vertical end horizontal fins individually or forming box louvers, facias and eaves boards upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand 3 graded stone aggregate 20mm nominal size).
Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete TMT bars.
Centering and shuttering including strutting, propping etc. and removal of form work for :-
Foundations, footings, bases of columns.
Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards.
Columns, pillars, piers, abutments, posts and struts.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Providing and fixing white writing boardite or equivalent in class room of size 8'-0' x 4'-0" with frame of portion aluminium (non magnetic type).
Providing and fixing of roller blinds (black out type) on the windows at heights, all materials and labour etc. complete in all respects as per directions Engineer-in-charge having specifications.(i) Fibre Glass (ii) Thickness 0.32mm (iii) Wt. 410 gram/sqm (iv) Degree of capacity 100%. (Material and colour shade will be as per sample approved by the department).
Earthwork in all kinds of soil excavation by manual means in trenches for foundations, drains, pipes, cable etc. (not exceeding 1.5 in width) and for shafts, wells, cesspits and the like not exceeding 10 Sqm on plan, depth upto 1.5 Mtr including disposal of excavated earth upto 1 Mtr from cutting edge, disposed earth is to be levelled and neatly dressed.
Supplying and filling in plinth with fine sand under floors including, watering, ramming consolidating and dressing complete.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal / vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.80mm thick with zinc coating not less than 275gm/sqm.
Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically & horizontally) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer-in-charge.
Engaging labour for cutting the walls floor etc. for laying of underground cables, dismantling / racking out plaster / bending of CGI sheets.
Mason
Labour
Welder
Helper
Welding set Higher charges (complete job).
Fitter
Providing and laying vaccum dewatered flooring (Tremix flooring) of RCC. M-20 including providing side shuttering with M.S channels, vibrating concrete by using screed vibrator and section dewatering using app. Make equipment and finishing the top surface to the required level and grade using power trowels of standard make. Providing and laying non metallic monothic surface hardening compound hard top over RCC/PCC floor with appliction @ 4 kg/sqm for tremix floor or as permanufacture specification (Abrarian resistance of 225% and compresive strength of 60 N/sqm) cutting the controlled be construction joint 5x25mm size in 3.0 m x 3.0 m panel with high precision floor saws and filling the controlled and construction joint with polyurphide sealent of sika make (FOSROC or equivalent make including the cost of making tale backup rod and other accessories required for filling the grooves (complete job).
Steel work welded in built up section/framed work including cutting, hoisting, flooring in position and applying a priming coat of approved steel primer using structural steel etc. as required (size of gate 14' x 10' with RCC piller 2' x 2' with 10' height)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z. sections and other sections of approved make conforming to IS : 733 and IS : 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber neoprene .. gasket felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing I panelling, C.P. brass I stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) For fixed portion Powder coated aluminium minimum thckness of powder coated 50 microns).
Providing and fixing fly proof wire gauze to windows, clerestory windows & doors with M.S Flat 15x3 mm and nuts &bolts complete. Galvanised M.S wire gauze with 0.63 mm dia wire and 1.4 mm aperature on both sides.
Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS: 8183 density 24kg/cum, 50mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3mm)@ 60cm c/c and wire mesh of 12.5mm x 24g wire for top most ceiling of building.
Making plinth protection 50mm thick cement concrete 1:3:6 (1 cement : 3 course sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth crushed.
Constructing brick masonry' road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:5 ( 1 cement: 5 fine sand) including 500x450 precast R.C.C. horizontal grating with frame: complete as per standard design with F.P.S bricks.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) alround S.W. pipes including bed concrete as per standard design 100 mm diameter S.W. pipe (Crushed).
Carriage of material by Mechanical Transport including loading / unloading and stacking at site complete.
Stone agg.below 40mm size for an avg. lead of 20 Kms.
Sand for an avg. lead of 20 Kms.
Disposal of excavated earth/mulba for an avg. lead of 7 Kms.
Bricks for an average lead of 20 Kms.
M/S MOHD ALYASS BHAT GOVT CONTRACTOR
M/s Kanhaiya Constructions
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
BOQ_184792.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .