SUPERINTENDING ENGINEER
OFFIVE OF THE SE OMCIV BTPS PTPP PARICHHA
Preventive Breakdown Maintenance of 6.6 KV Motors of 2x210 MW Unit 3 and 4 PTPP Parichha Jhansi
2020_RVUNL_490864_1
4/EMD-I/ET/BTPS/PTPP/2020-21
Open Tender
Electrical Works
Lump-sum
365 days
PTPP Parichha Jhansi
As per Tender
2 documents required · 2 mandatory
₹590
DY CAO PTPP PARICHHA
₹4,000
31 Aug 2020
9 Jul 2020
10 Aug 2020
9 Jul 2020
8 Aug 2020
9 Jul 2020
120 days
Amount
PART-A: SHIFTING /ROTATING BY 90DEG. & RESTORATION OF HT MOTORS AS PER SCOPE OF WORK.
Removal of canopy /Channels/Grills/ Mesh/Beam/Sheet of 6.6 KV, 340 KW Mill Motor.
Removal of canopy /Channels/Grills/ Mesh/Beam/Sheet of 6.6 KV, 350 KW TAC Motor
Removal of canopy /Channels/Grills/ Mesh/Beam/Sheet of 6.6 KV, 600 KW CEP Motor
Removal of canopy /Channels/Grills/ Mesh/Beam/Sheet of 6.6 KV, 660 KW FD Fan Motor
Removal of canopy /Channels/Grills/ Mesh/Beam/Sheet of 6.6 KV, 1300 KW PA Fan Motor
Removal of canopy /Channels/Grills/ Mesh/Beam/Sheet of 6.6 KV, 1550 KW ID Fan Motor
Shifting of motor from one foundation to the other foundation within same unit of 6.6 KV, 340 KW Mill Motor.
Shifting of motor from one foundation to the other foundation within same unit of 6.6 KV, 350 KW TAC Motor
Shifting of motor from one foundation to the other foundation within same unit of 6.6 KV, 375 KW ACW Motor
Shifting of motor from one foundation to the other foundation within same unit of 6.6 KV, 600 KW CEP Motor
Shifting of motor from one foundation to the other foundation within same unit of 6.6 KV, 660 KW FD Fan Motor
Shifting of motor from one foundation to the other foundation within same unit of 6.6 KV, 1300 KW PA Fan Motor
Shifting of motor from one foundation to the other foundation within same unit of 6.6 KV, 1550 KW ID Fan Motor
Shifting of motor from one foundation to the other foundation within same unit of 6.6 KV, 1600 KW C.W. Motor
Shifting of motor from one foundation to the other foundation within same unit of 6.6 KV, 3600 KW BFP Motor
Shifting of motors from one foundation Unit # 3 to the other foundation of Unit # 4 or vice versa of 6.6 KV, 340 KW Mill Motor.
Shifting of motors from one foundation Unit # 3 to the other foundation of Unit # 4 or vice versa of 6.6 KV, 350 KW TAC Motor
Shifting of motors from one foundation Unit # 3 to the other foundation of Unit # 4 or vice versa of 6.6 KV, 375 KW ACW Motor
Shifting of motors from one foundation Unit # 3 to the other foundation of Unit # 4 or vice versa of 6.6 KV, 600 KW CEP Motor
Shifting of motors from one foundation Unit # 3 to the other foundation of Unit # 4 or vice versa of 6.6 KV, 660 KW FD Fan Motor
Shifting of motors from one foundation Unit # 3 to the other foundation of Unit # 4 or vice versa of 6.6 KV, 1300 KW PA Fan Motor
Shifting of motors from one foundation Unit # 3 to the other foundation of Unit # 4 or vice versa of 6.6 KV, 1550 KW ID Fan Motor
Shifting of motors from one foundation Unit # 3 to the other foundation of Unit # 4 or vice versa of 6.6 KV, 1600 KW C.W. Motor
Shifting of motors from one foundation Unit # 3 to the other foundation of Unit # 4 or vice versa of 6.6 KV, 3600 KW BFP Motor
Shifting of motors from its foundation to ground or vice versa of 6.6 KV, 340 KW Mill Motor.
Shifting of motors from its foundation to ground or vice versa of 6.6 KV, 350 KW TAC Motor
Shifting of motors from its foundation to ground or vice versa of 6.6 KV, 375 KW ACW Motor
Shifting of motors from its foundation to ground or vice versa of 6.6 KV, 660 KW FD Fan Motor
Shifting of motors from its foundation to ground or vice versa of 6.6 KV, 1300 KW PA Fan Motor
Shifting of motors from its foundation to ground or vice versa of 6.6 KV, 1550 KW ID Fan Motor
Shifting of motors from its foundation to ground or vice versa of 6.6 KV, 1600 KW C.W. Motor
Shifting of motors from its foundation to TG Hall or vice versa of 6.6 KV, 340 KW Mill Motor.
Shifting of motors from its foundation to TG Hall or vice versa of 6.6 KV, 350 KW TAC Motor
Shifting of motors from its foundation to TG Hall or vice versa of 6.6 KV, 600 KW CEP Motor
Shifting of motors from its foundation to TG Hall or vice versa of 6.6 KV, 660 KW FD Fan Motor
Shifting of motors from its foundation to TG Hall or vice versa of 6.6 KV, 1300 KW PA Fan Motor
Shifting of motors from its foundation to TG Hall or vice versa of 6.6 KV, 1550 KW ID Fan Motor
Shifting of motors from its foundation to TG Hall or vice versa of 6.6 KV, 3600 KW BFP Motor
Shifting of motors from central store to TG Hall/Site or vice versa of 6.6 KV, 340 KW Mill Motor.
Shifting of motors from central store to TG Hall/Site or vice versa of 6.6 KV, 350 KW TAC Motor
Shifting of motors from central store to TG Hall/Site or vice versa of 6.6 KV, 375 KW ACW Motor
Shifting of motors from central store to TG Hall/Site or vice versa of 6.6 KV, 600 KW CEP Motor
Shifting of motors from central store to TG Hall/Site or vice versa of 6.6 KV, 660 KW FD Fan Motor
Shifting of motors from central store to TG Hall/Site or vice versa of 6.6 KV, 1300 KW PA Fan Motor
Shifting of motors from central store to TG Hall/Site or vice versa of 6.6 KV, 1550 KW ID Fan Motor
Shifting of motors from central store to TG Hall/Site or vice versa of 6.6 KV, 1600 KW C.W. Motor
Shifting of motors from central store to TG Hall/Site or vice versa of 6.6 KV, 3600 KW BFP Motor
Rotating of motor on its foundation by 90 Degree or restoring motor on its foundation of 6.6 KV, 340 KW Mill Motor.
Rotating of motor on its foundation by 90 Degree or restoring motor on its foundation of 6.6 KV, 350 KW TAC Motor
Rotating of motor on its foundation by 90 Degree or restoring motor on its foundation of 6.6 KV, 660 KW FD Fan Motor
Rotating of motor on its foundation by 90 Degree or restoring motor on its foundation of 6.6 KV, 1300 KW PA Fan Motor
Rotating of motor on its foundation by 90 Degree or restoring motor on its foundation of 6.6 KV, 1550 KW ID Fan Motor
Rotating of motor on its foundation by 90 Degree or restoring motor on its foundation of 6.6 KV, 3600 KW BFP Motor
Installation of canopy /Channels/Grills/ Mesh/Beam/Sheet of 6.6 KV, 340 KW Mill Motor.
Installation of canopy /Channels/Grills/ Mesh/Beam/Sheet of 6.6 KV, 350 KW TAC Motor
Installation of canopy /Channels/Grills/ Mesh/Beam/Sheet of 6.6 KV, 600 KW CEP Motor
Installation of canopy /Channels/Grills/ Mesh/Beam/Sheet of 6.6 KV, 660 KW FD Fan Motor
Installation of canopy /Channels/Grills/ Mesh/Beam/Sheet of 6.6 KV, 1300 KW PA Fan Motor
Installation of canopy /Channels/Grills/ Mesh/Beam/Sheet of 6.6 KV, 1550 KW ID Fan Motor
Providing suitable Hydra crane for loading and unloading of 6.6 KV motor at site within 08 hrs, if hydra crane is not provided by the department
PART-B: DISMANTLING & ASSEMBLY OF 6.6 KV MOTORS AS PER SCOPE OF WORK
Removal of coupling from rotor shaft of motor of 6.6 KV, 340 KW Mill Motor.
Removal of coupling from rotor shaft of motor of 6.6 KV, 350 KW TAC Motor
Removal of coupling from rotor shaft of motor of 6.6 KV, 375 KW ACW Motor
Removal of coupling from rotor shaft of motor of 6.6 KV, 600 KW CEP Motor
Removal of coupling from rotor shaft of motor of 6.6 KV, 660 KW FD Fan Motor
Removal of coupling from rotor shaft of motor of 6.6 KV, 1300 KW PA Fan Motor
Removal of coupling from rotor shaft of motor of 6.6 KV, 1550 KW ID Fan Motor
Removal of coupling from rotor shaft of motor of 6.6 KV, 1600 KW C.W. Motor
Removal of coupling from rotor shaft of motor of 6.6 KV, 3600 KW BFP Motor
Dismantling of motor as per scope of work of 6.6 KV, 340 KW Mill Motor.
Dismantling of motor as per scope of work of 6.6 KV, 350 KW TAC Motor
Dismantling of motor as per scope of work of motor of 6.6 KV, 375 KW ACW Motor
Dismantling of motor as per scope of work of 6.6 KV, 600 KW CEP Motor
Dismantling of motor as per scope of work of 6.6 KV, 660 KW FD Fan Motor
Dismantling of motor as per scope of work of 6.6 KV, 1300 KW PA Fan Motor
Dismantling of motor as per scope of work of 6.6 KV, 1550 KW ID Fan Motor
Dismantling of motor as per scope of work of 6.6 KV, 1600 KW C.W. Motor
Dismantling of motor as per scope of work of 6.6 KV, 3600 KW BFP Motor
Removal of DE/NDE side bearing of 6.6 KV, 340 KW Mill Motor.
Removal of DE/NDE side bearing of 6.6 KV, 350 KW TAC Motor
Removal of DE/NDE side bearing of 6.6 KV, 375 KW ACW Motor
Removal of DE/NDE side bearing of 6.6 KV, 600 KW CEP Motor
Removal of DE/NDE side bearing of 6.6 KV, 660 KW FD Fan Motor
Removal of DE/NDE side bearing of 6.6 KV, 1300 KW PA Fan Motor
Removal of DE/NDE side bearing of 6.6 KV, 1550 KW ID Fan Motor
Removal of DE/NDE side bearing of 6.6 KV, 1600 KW C.W. Motor
Removal of DE/NDE side bearing of 6.6 KV, 3600 KW BFP Motor
Installation of DE/NDE side bearing of 6.6 KV, 340 KW Mill Motor.
Installation of DE/NDE side bearing of 6.6 KV, 350 KW TAC Motor
Installation of DE/NDE side bearing of 6.6 KV, 375 KW ACW Motor
Installation of DE/NDE side bearing of 6.6 KV, 600 KW CEP Motor
Installation of DE/NDE side bearing of 6.6 KV, 660 KW FD Fan Motor
Installation of DE/NDE side bearing of 6.6 KV, 1300 KW PA Fan Motor
Installation of DE/NDE side bearing of 6.6 KV, 1550 KW ID Fan Motor
Installation of DE/NDE side bearing of 6.6 KV, 1600 KW C.W. Motor
Installation of DE/NDE side bearing of 6.6 KV, 3600 KW BFP Motor
Assembling of Motor as per scope of work of 6.6 KV, 340 KW Mill Motor.
Assembling of Motor as per scope of work of 6.6 KV, 350 KW TAC Motor
Assembling of Motor as per scope of work of 6.6 KV, 375 KW ACW Motor
Assembling of Motor as per scope of work of 6.6 KV, 600 KW CEP Motor
Assembling of Motor as per scope of work of 6.6 KV, 660 KW FD Fan Motor
Assembling of Motor as per scope of work of 6.6 KV, 1300 KW PA Fan Motor
Assembling of Motor as per scope of work of 6.6 KV, 1550 KW ID Fan Motor
Assembling of Motor as per scope of work of 6.6 KV, 1600 KW C.W. Motor
Assembling of Motor as per scope of work of 6.6 KV, 3600 KW BFP Motor
Installation of coupling on the shaft rotor of 6.6 KV, 340 KW Mill Motor.
Installation of coupling on the shaft rotor of 6.6 KV, 350 KW TAC Motor
Installation of coupling on the shaft rotor of 6.6 KV, 375 KW ACW Motor
Installation of coupling on the shaft rotor of 6.6 KV, 600 KW CEP Motor
Installation of coupling on the shaft rotor of 6.6 KV, 660 KW FD Fan Motor
Installation of coupling on the shaft rotor of 6.6 KV, 1300 KW PA Fan Motor
Installation of coupling on the shaft rotor of 6.6 KV, 1550 KW ID Fan Motor
Installation of coupling on the shaft rotor of 6.6 KV, 1600 KW C.W. Motor
Installation of coupling on the shaft rotor of 6.6 KV, 3600 KW BFP Motor
Fabrication and supply of grease plate, grease flinger, spring & Circlip etc as per sample of 6.6 KV, 340 KW Mill Motor.
Fabrication and supply of grease plate, grease flinger, spring & Circlip etc as per sample of 6.6 KV, 350 KW TAC Motor
Fabrication and supply of grease plate, grease flinger, spring & Circlip etc as per sample of 6.6 KV, 375 KW ACW Motor
Fabrication and supply of grease plate, grease flinger, spring & Circlip etc as per sample of 6.6 KV, 600 KW CEP Motor
Fabrication and supply of grease plate, grease flinger, spring & Circlip etc as per sample of 6.6 KV, 660 KW FD Fan Motor
Fabrication and supply of grease plate, grease flinger, spring & Circlip etc as per sample of 6.6 KV, 1300 KW PA Fan Motor
Fabrication and supply of grease plate, grease flinger, spring & Circlip etc as per sample of 6.6 KV, 1550 KW ID Fan Motor
Fabrication and supply of grease plate, grease flinger, spring & Circlip etc as per sample of 6.6 KV, 1600 KW C.W. Motor
Fabrication and installation of eye hook as per scope of work of 6.6 KV, 1600 KW C.W. Motor
Repairing of bearing housing of DE/NDE side bearings of of 6.6 KV, 340 KW Mill Motor.
Installation of coupling on the shaft rotor of 6.6 KV, 350 KW TAC Motor
Repairing of bearing housing of DE/NDE side bearings of 6.6 KV, 375 KW ACW Motor
Repairing of bearing housing of DE/NDE side bearings of 6.6 KV, 600 KW CEP Motor
Repairing of bearing housing of DE/NDE side bearings of 6.6 KV, 660 KW FD Fan Motor
Repairing of bearing housing of DE/NDE side bearings of 6.6 KV, 1300 KW PA Fan Motor
Repairing of bearing housing of DE/NDE side bearings of 6.6 KV, 1550 KW ID Fan Motor
Repairing of bearing housing of DE/NDE side bearings of 6.6 KV, 1600 KW C.W. Motor
Repairing of bearing housing of DE/NDE side bearings of 6.6 KV, 3600 KW BFP Motor
Replacement of oil gaskets of DE/NDE side bearings of 6.6 KV, 3600 KW BFP Motor
M/S NOSAD CONTRACTOR
M/S PRIYA CONSTRUCTION CO.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .