Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 CrAccepted-AOC 17 1624A MUMDAMVELI KOCHI 682 507 | ERNAKULAM | KERALA | 682507 | ₹39.4 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹39.5 CrRejected-Finance MANATHA ENCLAVE 3RD FLOOR OLIMUGAL KAKKANAD P O KOCHI 682 030 KERALA | ERNAKULAM | KERALA | 682030 | ₹39.5 Cr | L2 | Rejected-Finance NOT BEING L1 |
| 3 | L3₹39.6 CrRejected-Finance 216 C SIVA COLONY MAYO LINK ROAD AJMER RAJASTHAN 305007 | AJMER | RAJASTHAN | 305007 | ₹39.6 Cr | L3 | Rejected-Finance NOT BEING L1 |
| 4 | L4₹40.5 CrRejected-Finance | ₹40.5 Cr | L4 | Rejected-Finance NOT BEING L1 |
| 5 | L5₹44.3 CrRejected-Finance | ₹44.3 Cr | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
Refer Docs
EMD Value
₹15 L
Closing Date
6 May 2021, 6:00 pmClosed
CHIEF ENGINEER CG GOA
CHIEF ENGINEER CG GOA 403806
PROVISION OF MARRIED ACCOMMODATION AND ALLIED FACILITIES FOR COAST AIR ENCLAVE NEDUMBASSERY KOCHI PACKAGE I
2021_MES_427740_1
82026/E8
Open Tender
Civil Works
780 days
Kochi
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE (I) (CG) KOCHI
₹15 L
Yes
HQ CE CG GOA
5 Aug 2021
4 Mar 2021
10 May 2021
4 Mar 2021
6 May 2021
26 Apr 2021
15 Mar 2021
Amount
SCHEDULE "A" Part - I (BUILDING/ STRUCTURE WORKS) Details of prepriced schedule is given in tender documents.
SCHEDULE "A" PART-II ( EARTH WORK AND SITE CLEARENCE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD/PATH/CULVERT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (STP TREATED WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XI (LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XII (AVIATION LIGHT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIII (TV / TELEPHONE LINES & SOCKETS ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIV (FIRE FIGHTING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XV (MISCELLANIOUS B/R & E/M WORKS & SERVICES) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' E ' signifies this fact only.
PILE FOUNDATION Boring Cast in situ DMC pile of 600mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials outside MD land complete all as specified and directed. Note:- (i) The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment separately. (ii) This item will be executed as per location marked in drg.
Boring Cast in situ DMC pile of 450mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials outside MD land complete all as specified and directed. Note:- (i) The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment separately. (ii) This item will be executed as per location marked in drg.
Reinforced cement concrete of grade RMC M-30 design mix as per IS – 456 with using 20mm graded stone aggregate in cast in situ bored pile of any length/any sections complete all as specified and as shown on drg as in bored pile including destructive integrity test on all pile as per IS-14893,2001 part-IV. (Note: The unit rate quoted under this item is deemed to be inclusive of charges for non destructive integrity test)
RCC grade RMC M30 design mix as per IS–456 using 20mm graded stone aggregate in pile caps , grade beams etc complete all as specified and shown on drg. Notes for Sl item Nos 15.03 & 15.04 :- Reinforcement shall be measured and paid for separately under relevant items of this Schedule.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over for bored piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Ditto All as per item No 15.05 here-in-before but for pile caps/ grade beams complete all as specified and directed.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 5 mm dia end over up to and including 10mm dia conforming to IS-1786 as in Helical/stirrups for piles cut to length, bent to shape required, and binding with 0.9mm dia MS annealed wire or welding .
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 5 mm dia end over up to and including 10mm dia conforming to IS-1786 as in stirrups for piles caps/ grade beams cut to length, bent to shape required, and binding with 0.9mm dia MS annealed wire or welding .
PCC 1:4:8 type D2 using 40mm graded stone aggregate for concrete layer below pile caps and foundation complete all as specfified and as shown in drg
Formwork to sides of concrete foundation, pile caps etc rough finished surface of concrete flat. All as specified and as directed.
Excavating over areas, n exc1.5 m deep and getting out for In Soft/loose soil for pile cap
Excavating over areas, exc 1.5 m deep and getting out in soil for foundation in soft/loose soil for pile cap beam
Returning/filling in layers and ramming in layers around pile cap,plinth beam etc using excavated soil incl sprading,levelling,well ramming in layers not less than 25cm thick.
Removing excavated material exc 1.5Km n.exc 5Km and depositing where directed at a level n.exc 1.5m above starting point
Testing of piles for 600mm dia Cast in situ piles (Initial Load test for compression load, lateral load & uplift load) all as per IS 2911 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 600mm dia cast in situ pile. Note: Rate inclusive for casting of 04 piles for above test. However concrete, steel and boring shall be measured and paid under respective items
Testing of piles for 450mm dia Cast in situ piles (Initial Load test for compression load, lateral load & uplift load) all as per IS 2911 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed for 600mm dia cast in situ pile. Note: Rate inclusive for casting of 04 piles for above test. However concrete, steel and boring shall be measured and paid under respective items
Testing of piles (Routine Load test) all as per IS for 600mm dia Cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. Note: Only compression load test shall only be carried out for Routine load test.
Testing of piles (Routine Load test) all as per IS for450mm dia Cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. Note: Only compression load test shall only be carried out for Routine load test.
INTERNAL WATER SUPPLY Supply & fixing 15 mm dia Bib taps Areotor type (including connected fitting for joing with 20mm dia pipes) with restrictor 2.5 LPM at 3 bar pressurecomplete all as specified. Jaguar make (CQT-CHR-23037UPRG ) or equevlent in approved make of list attached
Supply & fixing wall mixer with provision for over head shower Areotor type with 115 mm long bend pipe on upper side, connecting legs, wall flenges & flow ristrictor of 2.5 LPM at 3 bar pressure complete all as specified Jaguar make ( CQT-CHR-23273G) or equevalent in approved make of list attached
Supply & fixing Over head shower Areotor type100 MM DIA single flow ( ABS body chrome plated with grey face plate) with rubit cleaning system and flow restrictor 6.0 LPM at 3 bar pressure and with Shower arm (SHA-CHR-477P) with wall flengecomplete all as specified. Jaguar make ( OHS-CHR-1989GA) or equevalent in approved make of list attached
Supply & fixing 15 mm dia regular body concealed stop cock (including connected fitting for joing with 20mm dia pipes) of concealed stop cock with fitting sleeve etc complete screwed both ends for pipe or for unions and fixed suitable for 20 mm bore of pipe , complete all as specified. Make: Jaguar make (ALD-CHR-089CQT) or equevalent in approved make of list attached
Supply & fixing 15 mm dia Angular stop cock (including connected fitting for joing with 20mm dia pipes) Jaguar make( CQT-CHR-23053) or equevalent in approved make of list attached
Supply & fixing 15 mm dia (including connected fitting for joing with 20mm dia pipes) Jaguar make 2 way bib cock with flow restrictor 3.8 LPM at 3 bar prssure complete all as specified.( CQT-CHR-23041GD) or equevalent in approved make of list attached
Supply & fixing complete all as specified.Jaguar make ACN-1153N Toilet Roll Holder with Flap) or equevalent in approved make of list attached
Supply & fixing Jaguar make health faucet (ABS Body) with 1 Meter Long PVC Tube & Wall Hook) & Flow resrictor 6.0 LPM at 3 bars pressure ( ALD-CHR-583GA) or equevalent in approved make of list attached
Supply & fixing 15 mm dia long body taps (including connected fitting for joing with 20mm dia pipes) with restrictor 2.5 LPM at 3 bar pressure (CQT-CHR-23037UPRG )or equevalent in approved make of list attached
Supply & fixing of pvc flexible pipe connections complete all as specified.
INTERNAL ELECTRIC SUPPLY S&F Modular Television Socket outlet with grip white 215v. complete all as directed. Make: Legrand Arteor Cat No.5734 25 or equivalent in list of approved Make attached
LED tube light fittings 1x35 W 230V, 4 feet long , energy efficient decorative ulta slim squre profile liner LED type fitting lighting fixture with extruded polycarbonate, energy efficient complete including housing all pre wire with high efficiency fixed to wall including connection by flexible 1.5 sqmm, PVC cable with stranded copper conductor from ceiling rose to connector of the fitting , complete all as specified. Make: PHILIPS Cat-Part No. BN308C LED40S-6500 L120 PSUWH with mounting accessories AC308CMBSA or equivalent in list of approved Make attached
LED tube light fittings 1x20W 230V, 4 feet long , energy efficient decorative ulta slim squre profile liner LED type fitting lighting fixture with extruded polycarbonate, energy efficient complete including housing all pre wire with high efficiency fixed to wall including connection by flexible 1.5 sqmm, PVC cable with stranded copper conductor from ceiling rose to connector of the fitting , complete all as specified. Make: BAJAJ Cat-Part No. 112785 BCLAB 20W or equivalent in list of approved Make attached
LED light fittings 1x10W 230V, 2 feet long, energy efficient decorative box type fitting with blue colour end caps for LED type fitting lighting fixture with extruded polycarbonate, energy efficient complete including housing all pre wire with high efficiency fixed to wall including connection by flexible 1.5 sqmm, PVC cable with stranded copper conductor from ceiling rose to connector of the fitting, complete all as specified. Make: BAJAJ Cat-Part-No. 112407 BCLSB 10 WH or equivalent in list of approved Make attached
Supply and fixing LED Lamp 10 watt, suitable for angular/ batten type lamp holder complete all as specified
Ceiling fan 1200 mm sweep, BLDC 5 star rating with down rod, canopy with out fan regulator and connecting up with and including provision of 3 core flexible PVC cable with standard copper condutor of size 1.5 sqmm form ceiling rose/connector to ceiling fan complete all as specified and as directed.
Exhaust fan,metal body havy duty AC single phase 300mm sweep, 1400 RPM complete with louvers protection when not in use, silent operation, rust proof body and blades and connecting up with and including provision of 3 single core PVC insulated copper conductor flexible cable of size 1.5 sqmm from ceiling rose/connector to fan out side lovering complete all as specified and directed.
Fresh air exhaust fan ,PVC body havy duty AC single phase 250mm sweep, 1200 RPM complete with louvers protection when not in use, silent operation, rust proof body and blades and connecting up with and including provision of 3 single core PVC insulated copper conductor flexible cable of size 1.5 sqmm from ceiling rose/connector to fan out side lovering complete all as specified and directed.
M&L powder coated sheet metal enclousres with Indstrial plug & socket with plug top and MCBs single pole with a 2 pin and earth plug and socket complete with MCB SPN 16 Amps for Geyser point.
M&L MCBs suitable for lighting load, 50 Hz, 10 kA of under mentioned types and rating (To be housed in DBs) here in before including making all electrical connection with suitable size of copper lugs complete all as directed of make Legrand / STANDARD/ Indo-Asian.- (i) MCB SP 20 Amps 240V.
(ii) MCB SP 16 Amps 240V.
(iii) MCB SP 6Amps 240V.
(v) MCB SP -10Amps 240V.
M&L for VTPN 4 Way DB, Double door powder coated Sheet Metal enclousre, fabricated out of 3.15mm CRCA Sheet of sutable size , with 4 Nos alum bus-bar of sutable size 200 Amps rating, mounted on procelain insulatours prewired complete with provision of fixing of 1 Nos of MCCB Four Ploe 100 / 125 Amps and 4 Nos MCB TPN 40 / 63 Amps all as spcified and directed.
M&L for VTPN 8 Way DB, Double door powder coated Sheet Metal enclousre, fabricated out of 3.15mm CRCA Sheet of sutable size , with 4 Nos alum bus-bar of sutable size 200 Amps rating, mounted on procelain insulatours prewired complete with provision of fixing of 1 Nos of MCCB Four Ploe 100 / 125 Amps and 8 Nos MCB TPN 40 / 63 Amps all as spcified and directed.
M&L MCBs suitable for lighting load, 50 Hz, 10 kA ISI Marked as per IS/IEC 60898-1 2002 Integrated label holder sliding bottom clamp Efficient air channels color coded On/Off indicaton IP 20 protected terminals of under mentioned types and rating (To be housed in DBs) here in before including making all electrical connection with suitable size of copper lugs complete all as directed (i) MCB FP 32A Amps 240V
M&L MCCBs suitable for lighting load, 63 Amps,50 Hz, 25 kA, ISI Marked as per IS/IEC 60898-1 2002 Integrated label holder Efficient air channels color coded On/Off indicaton IP 20 protected terminals here in before including making all electrical connection with suitable size of copper lugs complete all as directed of make Legeand/ STANDARD/ Indo-Asian.-
Supply and fix Tamper proof kWh meter Three phase, 4 wire solid state(static) fully Electronic energy meter, Accuracy class 1.0 & Current rating 10-60 Amp, with backlit LCD Display for 415 Volt system fitted with pilfer proof meter Box complete all as specified.
M & L for Bldg security light bracket made out of GI pipe light grade 40 mm dia 1.5 mtr length bent to shape , welding and well finishing including MS clamp of flat iron of size 40 x 6 mm suitable length 2 Nos complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats aluminium paint over a coat of red oxide primer.
S&F security light fittings 40W made out of pressure die cast housing with high power LED as light source & lens embedded PC cover with top opening seperate driver compartment with IP66 protection IK07 including control gear box complete all as specified and as directed.
S&F LED Batten 16 watt, Lumen effiency 120 Lm/W, 6500K with steel housing and poly corbonate difuser complete all as specified and as directed. Make: Philips Cat Part No BN308C LED 20S-6500L120 PSUWH or equivalent in list of make enclosed
ROAD/PATH/HARDSTANDING Providing and fixing reflective road studs (Raised pavement markers ) of category 'A' made out of poly carbonate /ABS moulded body and shanks and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromaticity values conforming to ASTM D4280 also confirming to MORTH circular No RW/NH.33023/10/97-DO III dt 11.06.97 and shall support a load of more than 13 t tested in accordance with ASTM D4280. Lenses shall be moulded of polycarbonate or methyl methecrylate conforming to ASTM D788 including installing by drilling the surface and fixing with adhessive.
Providing and erecting direction / place identification retro- reflectorised sign boards having area less than 0.9 sqm(3' x 3'), with 10 years warranty, manufactured as per IRC :67:2012 using Type XI ASTM D 4956-09 micro prismatic retro reflective sheeting fixed over aluminium sheeting , 2mm thick vide clause 801.3, supported on mild steel angle iron post 75mm x 75mm x 6mm, firmly fixed to the ground by means of properly designed foundation with M 20 grade cement concrete 45cm x 45cm x 60cm, 60cm below ground level including painting all non- reflective faces with epoxy paint 2 coats over epoxy primer
Providing and erecting direction / place identification retro- reflectorised sign boards having area exceedind 0.9 sqm (4' x 4'), with 10 years warranty, manufactured as per IRC :67:2012 using Type XI ASTM D 4956-09 micro prismatic retro reflective sheeting fixed over aluminium sheeting , 2mm thick vide clause 801.3, supported on mild steel angle iron post 75mm x 75mm x 6mm, firmly fixed to the ground by means of properly designed foundation with M 20 grade cement concrete 45cm x 45cm x 60cm, 60cm below ground level including painting all non- reflective faces with epoxy paint 2 coats over epoxy primer
S&F Convex Mirror having 130 degree of viewing angle made of one piece polycarbonate lens size of 0.80 mtr dia protect with any type of light ray, not produce toxic fumes If burnt complete with counting hardware all as specified and directed.
Preparing new plastered surfaces and applying Two coats of Acrylic Emulsion paint over a coat of primer on surfaces of walls as specified and directed
EXTERNAL ELECTRIFICATION Supply, install, test and commission LT panel board, indoor type,factory made, powder-coated, dust and vermin and weatherproof outdoor, cubicle type, outer shell made of 2 mm thick CRCA sheet and MS angle iron section of 50x50x6mm frame, front operated with locking arrangements. The bottom of outer shell contains a detachable plate having provision for entry of armored cable of adequate size with with glands and provision of louvers and air vent gasket for natural flow of air .The panel board shall have suitable busbar chamber having sufficient space to pass through UG cable and compartments for each control gear and metering devices. Providing busbar for phase and neutral and shall be insulated with color-coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non-combustible, track resistant, high-strength FRP/SMC/DMC material at an interval of not more than 300mm through out the length of TPN busbar all as specified and directed. (for Main Panel for Type V block) Aluminium bus bar for 3 phase, 440 volts, 50 Hz, 4 wire system of rating 200 Amps for phase and 100 Amps for neutral. Incoming MCCB 4 Pole, 415 Volts, 63 Amps, breaking capacity 36 KA - 01 No Metering unit R-Y-B indications (LED type) 1 sets Digital multi function meter 01 No, CT's- 125/5A, CL-1,15VA - 01 Set Outgoing (a) MCB C curve 4 Pole, 415 V, 40 Amps , 16 KA- 06 Nos (02 nos spare) (b) MCB C curve 2 Pole, 240 V, 32 Amps - 02 Nos (c) Astronomical digital timer - 01Nos (d) Contactor 32A (e) Panel mounted energy meter 3 phase 6-32A - 04 Nos (f) Panel mounted energy meter spare 6-32A - 02 Nos
Supply, install testing and commissioning Load Air break switch,compartmentalized, rated voltage 11 KV, rated current 630 Amps, frequency 50 Hz, 3 phase, fabricated with 2.00 mm CRCA sheet steel, finishing with electrostatic powder coated siemens grey colour. The panel is suitable for free standing indoor type, dust and vermin proof type complying to IS3427. The Load break switch shall be of compact Construction with epoxy insulators, double switch blades, forged contacts with arc quenching chamber, lagging pin and loop less current path. The Nylon/FRP insulation makes the switch light weight with greater electrical safety and mechanical strength. The LB Switch shall be comprised of:- (i) Mechanically inter locked Earth switch (ii) HT HRC fuses (iii) Shunt trip mechanism (iv)2 NO + 2 NC Auxiliary switch (v) Manual spring charging mechanism (vi) Mechanical on/off indication (vii) Mechanical Spring charge/Discharge indication . (viii) LBS On/Off indication. (ix) Main busbar:- 50mm x 10mm x 2 runs per phase- Aluminium flat (x) Surge arrestor (9KV 10 KA)Earth bus bar: 50mm x 10mm x 1 run Aluminium flat (xi) Space heater with thermostat (xii) Power terminals suitrable to receive XLPE without terminal (xiii) Control fuses,feerrules & wiring etc. (xiv) Overall size shall not be less than 850mm(W) X 1000mm (D) X 1850mm (H)
Supply,install,test and commision LT panel board,indoor type, factory made, powder coated , dust and vermin and weather proof, Cubicle type made out of 2 mm thick CRCA Sheet & MS angle iron section of 50X50X6 mm frame, front operated with locking arrangements. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands and provision for louvers and air vent gasket for natuaral flow of air . The panel board shall have suitable busbar chamber having sufficient space to pass through UG Cables and have compartments for each control gear and metering devices. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. (Main Panel) (PB-1) Copper busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 1000 Amps for phases and 500 Amps for Neutral.(Main LT Panel- LT-1) Incoming:-ACB 4 pole, 415 Volts, manual draw out type with micro processor release of capacity 800 Amps-01 No. Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No. ( c)CT's - 800/5A, CL-1,15 VA - 1 set Outgoing:- (a) MCCB 4 pole, 415 Volts, 315 Amps, breaking capacity 36 KA- 01 No. (b) MCCB 4 pole,415 Volts, 200 Amps, breaking capacity 36 KA- 02 Nos. (c) MCCB 4 pole,415 Volts, 160 Amps, breaking capacity 36 KA- 04 Nos.(I No. spare) (d) MCCB 4 pole,415 Volts, 125 Amps, breaking capacity 36 KA- 03 Nos.(I No. spare) (e) MCCB 4 pole,415 Volts, 100 Amps, breaking capacity 36 KA- 01 No.(I No. spare) ( f) MCCB 4 pole,415 Volts, 63 Amps, breaking capacity 36 KA- 02 No.
-Ditto- all as per item No15.57 above - but with the following accessories. . (DG PANEL- LT-2) Copper busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 300 Amps for Neutral. Incoming:- MCCB 4 pole, 415 Volts, 250 Amps, 50 KA -01 No. Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter with KWH & KVArh function - 01 No.( c)CT's - 250/5A, CL-1,15 VA - 1 set Outgoing:- (a) MCCB 4 pole, 415 Volts, 160 Amps, breaking capacity 36 KA- 01 No. (b) MCCB 4 pole,415 Volts, 125 Amps, breaking capacity 36 KA- 02 Nos. (c) MCCB 4 pole,415 Volts, 63 Amps, breaking capacity 36 KA- 09 Nos. (02Nos spare) ( d) MCCB 4 pole,415 Volts, 32 Amps, breaking capacity 16 KA- 02 No.
-Ditto- all as per item No.15.57- but with the following accessories. ( PUMP HOUSE NO.2- LT-3) Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 300 Amps for phases and 150 Amps for Neutral. Incoming:- MCCB 4 pole, 125 Amps, breaking capacity 36 KA- 01 No. Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter with KWH & KVArh function - 01 No. ( c)CT's - 125/5A, CL-1,15 VA - 1 set Outgoing:- (a) MCCB 4 pole, 415 Volts, 100 Amps, breaking capacity 25 KA- 04 Nos.(2 Spare) ( b) MCB SPN, 230 Volts, 32 Amps, 10 KA- 02 Nos. (c) DOL Starter suitable for 7.5 HP Pump set- 02 Nos. (d) Single phase preventer- 02 Nos.
-Ditto- all as per item No. 15.57 - but with the following accessories:- (PUMP HOUSE NO.1 PANEL- LT-5) Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 400 Amps for phases and 200 Amps for Neutral. Incoming:- MCCB 4 pole, 200 Amps, breaking capacity 36 KA- 01 No. Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No. with KWH and KVA function ( c)CT's - 200/5A, CL-1,15 VA - 1 set Outgoing:- (a) MCCB 4 pole, 415 Volts, 125 Amps, breaking capacity 36 KA- 04 Nos.(2 Spare) ( b) MCB SPN, 230 Volts, 32 Amps, 10 KA- 02 Nos. (c) Star Delta DOL Starter with suitable line contactors and relays suitable for 12.5 HP- 02 Nos. (d) Single phase preventer- 02 Nos.
-Ditto- all as per item No. 15.57 - but with the following accessories:- (a) LED Indicatory Lamp (b) Multi function Digital meter with KWH & KVA rh function Incoming: MCB 4Pole 32A -01Nos Outgoing:- (a) Astronomical Timer -01Nos (b) Contactor TP, 32Amps -01Nos
Supply and fixing LED street/Security light fittings, new generation energy saving and environmental friendly long life versatile die-cast aluminium housing IP 66 luminaire with high power LEDs 45W watts heat resistant toughened glass with frame including 3 core 1.5 sqmm FRLS, PVC insulated multistranded copper conductor cable for connection from junction box at the bottom of the pole to the light fitting including pvc protection pipe with necessary clamps, bolts, nuts and washers all as specified and directed by the Engineer in charge.
S & F KD thermoplastic jn boxes IP55 with metric knockouts for cable entry and four terminals suitable for LT cable upto size 4 core 50sqmm and the size of the box is 310mm x 210mm X 116mm
Supply and fix LED Flood light 150 W IP 66, energy saving, environmental friendly, exclusive innovation extruded aluminium housing with built in drive with power LEDs as light source suitable for High Mast Lights.
Supply and fix distribution board comprising of power contactor 32A 3 pole, digital time switch, 230V including connection complete.
EXTERNAL WATER SUPPLY Supply and fix Cast Iron air release valve with 50mm bore and two outlets as per IS:14845.
Material and labour valve chamber of internal size 0.9m x 0.9m x 0.9m (internal Dimensions), including excavation of earth work in any type of soil, 150mm thick PCC 1:4:8 type D2 Foundation, brickwork in CM 1:6, 15mm thick rendering in CM 1:4 to both internal and external surface up to 150mm depth below GL PCC 1:3:6 type C1 as in coping, cover with two No of hinges and one No handle made out of MS Round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drawing and specified. including all earthwork and connected items
Material and labour valve chamber of internal size 0.75m x 0.75m x 0.75m (internal Dimensions), including excavation of earth work in any type of soil, 150mm thick PCC 1:4:8 type D2 Foundation, brickwork in CM 1:6, 15mm thick rendering in CM 1:4 to both internal and external surface up to 150mm depth below GL PCC 1:3:6 type C1 as in coping, cover with two No of hinges and one No handle made out of MS Round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drawing and specified. including all earthwork and connected items
TREATED WATER SUPPLY Supply and fix Cast Iron air release valve with 50mm bore and two outlets as per IS:14845.
Material and labour valve chamber of internal size 1.2m x 1.2m x 1.2m (internal Dimensions), including excavation of earth work in any type of soil, 150mm thick PCC 1:4:8 type D2 Foundation, brickwork in CM 1:6, 15mm thick rendering in CM 1:4 to both internal and external surface up to 150mm depth below GL PCC 1:3:6 type C1 as in coping, cover with two No of hinges and one No handle made out of MS Round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drawing and specified. including all earthwork and connected items
Supply, install, test and commission LT panel board, indoor type, factory made, powder-coated, dust and vermin and weatherproof , cubicle type, outer shell made of 2 mm thick CRCA sheet and MS angle iron section of 50x50x6mm frame, front operated with locking arrangements. The bottom of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with with glands and provision of louvers and air vent gasket for natural flow of air .The panel board shall have suitable busbar chamber having sufficient space to pass through UG cable and compartments for each control gear and metering devices. Providing busbar for phase and neutral and shall be insulated with color-coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non-combustible, track resistant, high-strength FRP/SMC/DMC material at an interval of not more than 300mm through out the length of TPN busbar all as specified and directed. Aluminium bus bar for 3 phase, 440 volts, 50 Hz, 4 wire system of rating 300 Amps for phase and 150 Amps for neutral. Incoming: MCCB 4 Pole, 415 Volts, 160 Amps, breaking capacity 50 KA - 01 No Metering unit: R-Y-B indications (LED type) 1 sets Digital multi function meter 01 No, (c) CT's- 160/5A, CL-1,15VA - 01 Set Outgoing: (a) MCCB 4 Pole, 415 V, 125 Amps , Breaking capacity 36 KA- 02 nos spare (b) MCCB 4 Pole, 415 V, 63 Amps , Breaking capacity - 02 nos spare
AVIATION LIGHT Supply and fix Aviation obstruction light LED type including necessary cabling all as specified and directed. MAKE Bajaj Cat No BGAV 302 LED.
Supply & Fix 6 Amps SPN MCB
TV / TELEPHONE PIPES & SOCKETS Material & labour Standard metal flush box 1 module.
Material & labour Standard modular plate 1 module.
Material & labour Standard telephone socket RJ-11
GEYSER Supply & fix water heater storage type, electric, capacity 25 ltrs BEE 5 Star rated. MAKE : Havells Cat Part No: GHWAMGTWH025 or equivalent in list of approved Makes attached
Supply & fix geyser connection stainless steel flexible pipe of length 18" with checknut all as specified and directed.
FIRE FIGHTING Supply, connect, joint and lay MS flanged pipe heavy duty ISI marked with all fittings of size 100 mm dia with flanged ends and including flanges, leather gaskets, heavy duty bolts, nuts, washers etc, laid in trenches,floors, fixed on walls/floors/roof ete including fixing with clamps on wall for the wet riser including painting with approved synthetic enamel paint all as specified and directed by Engr-in-charge.
Supply and installation, testing and commissioning of Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display,having Controls For Reset, Mute, Accept , Silence alarms and Self Test, with programmable free keys and Duly Approved by EN54/LPCB/VDS/FM all as specified and directed by Engr-in-Charge.
S&F wall mounted LED emergency Exit signage luminaire Light up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours (Cat No LSSR5W Make CG or equivalent to Bajaj/havells.
Supply and fix PVC insulated armoured copper conductor of size 1.5 sqmm with working voltage 1100 volts (IS:1554 Part-I) Make-havells/V'guard/equivalent.
Supply and fixing fire extinguisher dry chemical powder (ABC) type 4 kg capcity IS 15683 all complete as specified and directed.
Supply and fixing fire extinguisher CO2 type 3 kg capacity squeeze gripoperative light weight IS 15683 all complete as specified and directed.
S & F fire extinguisher Mechnical foam extinguisher (stored pressure type) (IS:15683) of capacity 9 ltr.
S & F fire bucket (dry sand) as per IS:2546
Supply,install,test and commision LT feeder pillar box type panel,outdoor type, powder coated , dust and vermin and weather proof outdoor, Cubicle type, outer shell made out of 3.15 mm thick CRCA Sheet & MS angle iron section of 50X50X6 mm frame , factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides having chromium plated 19 mm dia fancy keys, louvers & air vent gasket for natuaral flow of air. Suitable gasket shall be used to make the outer shell completely vermin proof. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2.0 mm thick CRCA Sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing MCCB's/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 200 Amps for phases and 100 Amps for Neutral Incoming:-MCCB 4 pole, 415 Volts, 63 Amps, breaking capacity 25 KA- 01 No. Metering Unit:- (a) R-Y-B indications (LED type) 1 sets (b) Digital multi function meter 01 No, (c) CT's- 160/5A, CL-1,15VA - 01 Set Outgoing:- (a) MCB TPN 32 Amps "D" curve 10 KA - 2 Nos (b) Star delta starter - nil (c) DOL starter - 01 Nos (d) Contactor suitable for 7.5 HP motor - 01 Nos (e) Provn for pressure switch -01 No
SOLAR LIGHTS Supply and install solar Standalone Streetlight system consists of Solar LED Luminiare 30W with high efficiency mono crystalline solar PV module, Solar Panel, Lithium Ferro Phosphate battery with inbuilt BMS technology, high efficiency LED, MPPT Solar charge controller and aluminium extruded body and aesthetically designed decorative hot dipped galvanised mild steel pole, 6m with grey powder finish window - Plasma cut & duly chamfered opening window of 300 x 110 mm for terminal connections & GI fabricated mounting accessories including excavation and all earthworks, PCC foundation for pole and all connected works as directed at site all as specified and directed. For fitting Make Haveils Cat No SSSSLX0140 ALL IN ONE 30 W SSL or equivalent in Bajaj/ Philips For pole Make Havells Cat No 7308 6M POLE
Material and labour Earthing complete with galvanized steel Earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground vertically to a depth not less than 2.25 meters below the normal ground level with top edge of the plate not less than 1.5 meter below normal ground level and connected to galvanized iron strip 32 x 6mm size by means of bolts, nut. check nuts and Washers of galvanized iron steel all as shown in electric plate no 5 connected to earthing test Point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 ( using 20mm graded aggregate) common salt, charcoal, CI funnel or earth pit cover in RCC 1:2:4 type B1 ( using 20mm graded aggregate) with 8mm CTD bars @ 100mm c/c in both ways including necessary form work complete including necessary test on completion all are specified and directed. NOTE : The unit rate should also include for excavation, earthwork in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 40mm dia watering pipe, wire mesh, 40mm dia light grade GI protection pipe for Earth lead etc complete.
Material and labour Earthing complete with galvanized steel Earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground vertically to a depth not less than 2.25 meters below the normal ground level with top edge of the plate not less than 1.5 meter below normal ground level and connected to galvanized earth wire 4mm dia by means of bolts, nut. check nuts and Washers of galvanized iron steel all as shown in electric plate no 5 connected to earthing test Point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 ( using 20mm graded aggregate) common salt, charcoal, CI funnel or earth pit cover in RCC 1:2:4 type B1 ( using 20mm graded aggregate) with 8mm CTD bars @ 100mm c/c in both ways including necessary form work complete including necessary test on completion all are specified and directed. ( Earthing to Poles) NOTE : The unit rate should also include for excavation, earthwork in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 40mm dia watering pipe, wire mesh, 40mm dia light grade GI protection pipe for Earth lead etc complete.
SOLAR POWER PLANT Supply, installation, Testing & commissioning of Roof top Solar Power Plant of 30 KW including solar panel, solar Inverter, Module Mounting structure and comprising of following: (i) Solar PV module Pmax 380 Wp monoperc cells efficiency not less than 16.20, Voc 30 Isc 09, 03 AR coated antimony free glass material 25 years performance warranty with connecting junction box all as specified Make Havells, Lanco, adani, TATA, Topsun 1143 no (ii) Grid tied inverters 3 phase 20 KW 50 Hz having 02 separate MPP tracker with SPD glass surge protection devices having efficiency 98% graphical display.inbuilt LED interface with RS485 and compatible for online monitoring systore suitable for Ambient temperature of KOCHI, protection IP 65, overvoltage/ under voltage protection all as specified. Make-Havells, ABB, Siemens, schneider, TATA Qty -01 Each ( 10 Years warranty (iii) DC solar distribution Box to colect the DC output from Array junction Box and supply to inverter weatherproof for outdoor applications and including MCB/MCCB of proper rating depending upon the cap of the power plant complete all as specified. MAKE : HPL, Schneider, Havells (iv) AC solar distribution Box to collect the DC output from Array Junction Box and supply to inverter weatherproof for outdoor applications and including MCB MCCB of proper rating depending upon the cap of the power plant complete all spd MAKE : HPL, Schneider, Havells (v) Grid interfacing unit having MCCB cap 63 Amp 4 Pole 25 KA microprocessor based all as specified. Make- Havells/ABB/L&T/Schneider/Siemens 01 Each set. (vi) Cables as per site requirement from PV Module To LT Panel: 1 Core X 4sqmm, 1 C X 6 Sqmm solar cable, 4Core X 10 sqmm,Cu unarmored. (vii) Online monitoring system Make Havells/ Delta/ KACO or as approved.
(viii) Hot dip galvanised MS/ Aluminium mounting structure for mounting of modules /array panels et, such structure should have angle of inclination as per site conditions take max insolation, mounting structure shall be designed to withstand the speed of 150 KM per hour be designed, fasting arrangements grouting, clamping etc provided to secure the installation against Online monitoring system Make- Havells/ Delta /KACO or as approved complete all as specified Note: The mounting structure shall be as per latest IS, galvanised of the mounting structure shall be in compliance, structural material shall be corrosion resistent and electrolyticaly compatible with the materials used in the module frame, its nuts and bolts the fasteners used should be make up of mild steel. the structures shall be designed to allow easy replacement of any module PCC foundation if required deemed to be included. (ix) Meter reading instruments with suitable software of capacity 16.5 MB to record reading through optical communicatin port of any type of meter Make Secure/ HPL Havells (x) 3 phase DLMS type integrated meter with inbuilt CT & GSM Modern energy meter having LCD display, 50 Hz +/- 5%, provision of sealing on mains cover and terminal cover IP 51, tamper information, inbuilt battery back up to active its display in absence of power. optical port for local communication, Optional RS232 port on RJ-11 for remote communication, in built memory for load survey data. Class 0.5s, ( 3X 240V (P-N),-/5A) Make Secure/ HPL
Supply and install Static silent Diesel Engine with accoustic enclosure, capable of delivering 128 Kw (160 KVA), water cooled, 415 volts (AC three phase, 4 wire system of supply) , frequency 50 Hz, at power factor 0.80 minimum. The DG set shall consists of a diesel engine coupled to a matching the alternator through flexible coupling and mounted on a common based frame and complete with control panel standardized by the manufacturer, fuel tank with mounting arrangements and with standard fuel pipes for inlet, outlet and return inlet oil arrangements, exhaust pipe, silencer and asbestrose rope protection completye and shall be suitable for conditions prevailed at Kochi. (Designed capacity of Diesel engine and alternator shall be worked out by considering all derating factors prevailed at the area to be installed) The foundation of Gen Set shall be as specified by the manufacturer and shall be mounted on a suitable Channel frame structure with anti-vibration pads and including all technical features to comply with latest CPCB guidelines and comprising of followings:- (i) DIESEL ENGINE (Prime Mover): Diesel Engine 1500 RPM, direct injection, six cylinders, four stroke, confirming to ISO3046/BS5514, water cooled, natuarally turbo charged, capable of giving adequate BHP to drive alternator capable of delivering 128 Kw(160 KVA) at outdoor atmospheric conditions at Nedumbassery (Considering all derating factors prevailed in the area). Batteries 12/24 Volts and desired ampere hours (as per manufacturers recommendations), electric battery start, complete with fly wheel and all standard fittings and fixtures as per manufacturer and including suitable panel with techo meter, lub oil temperature, pressure gauge and frequenvy meters. The engine shall have self starter, dynamo, FIP, oil pump, fuel electric control panel with mechanical governor (ECPG) and Engine protection system (Shut down, High water temperature, low lub oil, oil pressure, over speed etc. , recommented capacity of fuel tank and first filling of fuel and lub oil and other consumables etc. (ii) ALTERNATOR: Brushless AC alternator, 3 phase, 415 Volts, 4 wire rated for output of 128 Kw (160 KVA) minimum power factort 0.80, 1500 RPM, IP 23 ptotection class enclosure, insulation class 'H', salient pole, revolving field, single bearing, automatic voltage regulator coupled through flexible coupling with and match the above engine.
(iii) BASE PLATE:- Made of structural steel as per manufacturers recommended design/specifications. (iv) ACOUSTIC ENCLOSURE:- Sheet metal fabricated canopy type, silent enclosure, manufactured on CNC machines as per CPCB norms and powder coated. The enclosure shall be designed for reducing the sound level to 75 DB at a distance of 1 mtr at 75% load under field condition and 70DB at 3 M from Gen Set when DG set is working at full load along with testing conformance, labeling certification etc. as laid down in GSR No. 371(E) dt 17 May 2002. (i) Foundation/Plinth/Base shall be provided as per manufacturers recommendations, however minimum 0.50 M space should be available all around the set and height of plinth shall not be less than 0.50 M. (ii) Standard Diesel Engine tank of adequate capacity for running the Gen Set continuously for 12 hours including standard pvc pipes from tank to FIP, overflow pipe from FIP to tank. (v) MISCELLANEOUS:- Tool kit, Operation and maintenance catalogue, spare parts list, overhauling manuals, guarantee cards, test certificate of Engine and alternator etc. shall be provided as per manufacturer standard practice. (vi) AMF CONTROL PANEL:- factory made cubicle type floor mounted LT Panel board, indoor type made out of MS angle not less than 40x40x50 mmand 2 mm thick MS CRCA Sheet, front opening type, protection class IP-54, duly powder coated, copper bus bar with coloured PVC sleeves and of suitable rating for four poles mounted on suitable porcelain insulators at recommended intervals, with all standard switch gear and protection, intyernal wiring with adequate size and rating PVC insulated multistranded copper conductor cables etc. and also consisting the following: Copper busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 300 Amps for Neutral. Incoming:- (a) MCCB 4 pole,415 Volts, 320 Amps, breaking capacity 36 KA- 02 Nos.
Metering Unit and other accessories :- (a) R Y B Indications (LED Type) - 1 set. (b) Indicator for on/off GEN/MAIN supply- 2 Nos. (c) Digital Multi function meter - 01 No. ( d) CT's - 320/5A, CL-1,15 VA - 1 set (e) 3 pole line Contactorwith AC coil, 225 Amps- 2 Nos. (f) All standard relays, circuits and protection required for automatic operation of DG set. (g) Charger for recharging the battery and armoured copper cable of suitable rating from battery charger to the engine- one job.
M & L for earth continuity conductor of size 32 x 6mm GI strip all as specified and directed
M & L GI Pipe of light grade 40mm dia under trench, floor or on walls for protection of GI strip all as specified and directed
S & F cable tray for telephone wire using PVC rigid cable tray from groung floor junction box to all individual quarter of size A 60 x 60 complete all as specified and directed. Make L&T cat part No WWA6060SG or equivalent in list of approved Makes attached
S & F cable tray forTV co-axial wire using PVC rigid cable tray from groung floor junction box to all individual quarter of size B 100 x 80 complete all as specified and directed. Make L&T cat part No WWB10080SG or equivalent in list of approved Makes attached
Supply, install & commissioning of Electrically operated, fully automatic Incinerator having 10kg/hour burning capacity with horizontal/ vertical type comprising of primary, secondary chamber, designed on “controlled air” incineration principle and provided with minimum of 115mm thick refrectory and insulation bricks confirming to IS 8-1994 and IS 2042-2006 to sustain minimum temperature of 500 degree centigrade, one fully automatic pressure jet type burner for each chamber, chamber made of mild steel plate of adequate thickness (minimum 5mm thk), 3000mm high chimney, exhaust system, high pressure ventury scrubber, PLC based control panel, droplet seperator eth including all other accessories and piping, equipements and civil works required for installation of Incinerator chimney complete all as specified, including following: (a) Body made of MS steel (b) 50mm insulation (c) Loading Hull at the bottom (d) Primary and secondary chamber along with independent temprature control
Supply and Install Organic Waste Converter fully automatic having capacity 150Kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:- Type of machine: Fulley automatic in-vessel composter Composting method: Micro-organism base organic composting Type of microganism used: Heat resistant thermophilic bacteria Final Output: Organic soil additive Cycle time: 24Hrs Volume reduction in 24Hrs: 85-90% Internal tank: Stainless steel type Main agitator Shaft: Stainless steel type Input voltage: 415V Special features: VFD as standard across all models, Touchscreen standards Daily waste processing: 150Kgs Rated capacity: 7KW Power consumption (KWH par cycle): 13-15 Length: 1650, Width: 850, Height: 1455
ELECTRICAL MECHANICAL COMPONENTS OF STP: Design, construction, Supply, installation, testing & commissioning of Sewage Treatment Plant based on principle of aerobic attached growth non clogging randomly Moving bed Bio reactor (MBBR) having capacity not less than 200 KLD, including required foundations all as specified shown in drawings and directed by Engineer -in- charge
Scope of Design: (a) Site survey of total area under Coast Guard Air Enclave Nedumbassary, Kochi for STP location and treated water sump for Package ! and Package 2. (b) Collection of present population data, arrive at futurisitic population and design the sewerage line network for complete area of 18 Acre and sewage treatment plant (From first manhole to last pertaining point of treated water) (c) Collection of existing water supply data and sewage network data. (d) Qualitative and quantitive assessment of waste water. (e) Design of STP of on the principle of aerobic attached growth non clogging randomly Moving bed Bio- Reactor (MBBR) including mechanical and civil works for STP of approximate capacity 200Cum/ day as per the OEM specification to achive desired treated sewage parameters as given in Appx 'B' or parameters as per NGT principle bench New Delhi is supirior (Refer E-in-C's branch letter No 86435/Mis/policy/54/E4 (U3) dtd 24/04/2020 (f) Design of STP shall comply guideleine issued by Kerala pollution Control Board including management of soild waste/ sludge generated out of treatment process and also guideline issued by NGT. (g) Design of STP shall include complete Arch design, Structural Design including treated water collection sump with pump house, Mechanical control & circuiting instrumenation (MEP design) etc. Schematic treatment process flow diagram with drawings will be enclosed as per Kerala State Pollution Control Board. (h) all equipment and civil works will be designed considering atmosphere conditions prevailing at Kochi. (j) Before finalizing the report, a presentation shall be made by the firm in the presence of officials from both Coast Guard and MES at Nedumbassary Kochi and CE office to finalize the details. (k) Sunbmission of interim report incl design calculations & Drawings (l) Submission of final report with all parameters, calculation of scheme, schematic layout of prop. system Arch, Structural, mechanical and Electrical drawings dully vetted by IIT/ NIT.
Desired quality effluent of non portable reuses is given as per E-in-C’s Branch letter No. 86435/Misc/E4(U3) dated 19 May 2017 or parameters as per NGT principle bench New Delhi judgement as delivered on 30 April 2020 on OA No. 1069/2018, which ever is superior (please refer E-in-C’s Branch letter No. 86435/Misc/policy/54/E4 (U3) dated 24 Apr 2020) Scope of Work (as per Design) (a) Two No. Fine bar screen of MSEP construction as per designed specifications, to be installed in fine bar screen chamber, to prevent floating objects passing through it and subsequently removing manually and dumped for further disposal. (b) Air grid for equalization tank for providing aeration in the tank, as specified in PS. (c) Two Nos Raw sewage centrifugal monobloc pumps complete with motor and all necessary accessories and fittings, to be installed for transferring sewage from equalization tank to process reactor. Level sencor should be provided in the tank and interlinked with pumps for ON-OFF operation as per water level in the tank. One pressure gauge for eacg pumps has to be provided to measure at the outlet. MOC : Cast iron Type : Sewage submersible Solid handling 20 mm Qty : 04 Nos (2w+2S) Make : Kiloskar/KSB/Grundfoss (d) Four Nos twin lobe type Air blower with motor, for providing Air in equalization tank, MBBR reactors 1 & 2, equalization tank, sludge holding tank for measurement of quantity of air, Air Grid Type : Header & Lateral Type. MOC : SS304 Casting : C I conforming to IS : 210 Gr FG 260 Rotor : Alloy Steel Shaft : Carbon Steel C40/EN 24/19 Timing Gear : Cast Alloy Steel Pulley and gear side plates and cover : C I conforming to IS 210 Gr FG 260 Make : Everest/ KPT/ Atlas Capco/ Kaesar/ Aerzen
(e) Two Nos, anoxic chamber in MSFRP construction with all internals comprising of media, media retaining sieves and mixer. MOC : MS FRP (06 mm thick MS sheet & 3 mm thick FRP) Make : Thermax / Optimus enviropro/ SIMA Lab/ ion Exchange (f) Four Nos : MBBR tanks in MSFRP construction with all internals comprising of media, SS air grid & SS rise pipe, media retaining sieves, etc. MOC : MS FRP (6 mm thick MS Sheet & 3mm thick FRP) Make : Thermax / Optimus Enviropro /SIMA Lab/ Ion Exchange. (g) Four Nos : sludge transfer self priming monobloc pumps complete with motor and all necessary accessories and fittings for transferring sludge form bottom of the tube settler to the sludge holding tank. One pressure gauge for each pump has to be provided to measure at the outlet. MOC : Cast Iron Type : Monobloc, sewage self priming pumps Qty : 04 Nos (2W + 2S) Make : Kirloskar / C& G/ KSB/ Mather & Platt (h) Two Nos. tube settler tank in MS FRP construction with media and collection through. MOC : MS FRP (6mm thick MS sheet & 3 mm thick FRP) Make : Thermax /Optimus Enviro/ SIMA Lab/ Ion Exchange (i) Four nos, sewage centrifugal monobloc self priming recirculation pumps complete with motor and all necessary accessories and fitting for recirculation of biomass with sewage to the anoxic chamber. One pressure guage for each pump has to be provided to measure pressure at the outlet. MOC : Cast Iron Type : Sewage Self priming Centrifugal Qty : 04 Nos (2W + 2S) Make : Kirloskar / KSB/ Grundfoss
(j) One No. Sludge Holding tank in MS FRP construction as per given specifications, to receive sludge from tube settler by gravity. MOC : MS FRP (6mm thick MS Steel & 3mm thick FRP) Volume of tank : 7.7 m3 Make : Thermax /Optimus Enviropro/ SIMA Lab/Ion Exchange. (k) One no. Chlorine Contact cum filter feed tank in MSP FRP construction as per given specifications. MOC : MS FRP (6mm) thick MS Sheet & 3 mm thick FRP) Make : Thermaxc / Optimus Enviropro / SIMA LAB / Ion Exchange (l) One set of Sodium Hypo Chlorite dosing system comprising of 2 nos. dosing pump and one no Solution tank, all as specified. Make : Minimax / eDose (m) Two Nos. filter feed centrifugal monbloc pumps complete with motor aand all necessary accessories and fittings for feeding tertiary unit. Level sensor should be provided in the chlorine contact cum filter feed tank and intelinked with pums for ON-OFF operation as per level in the sump. One pressure gauge for each pump h as to be provided to measure pressure at the outlet. Type : centrifugal Monobloc MOC : Cast Iron Qty : Nos (1W + 1S) Make : Kirloskar / KSB/ Grundfoss (n) One No. Dual media filter, complete with media, frontal piping, valve and pressure and gauges to measure pressure across the filter. MOC : Mild Steel bituminous paint inside. Thickness of Sheet : 05 mm shell / 6mm dish Make : MES approved vendors. (o) One No. Activated Carbon Filter of complete with media, frontal piping, valve and pressure and gauges to measure pressure across the filter. MOC : Mild Steel bituminous paint inside. Thickness of Sheet : 05 mm shell / 6mm dish Make : MES approved vendors.
(p) One No. Tertiary Treated Water Tank in MS FRP construction, to receive supernatant coming from tertiary treatment plant, as per given specification MOC : MS FRP (6mm thick MS Sheet & 3 mm thick FRP) Qty : 1 NO Make : Thermax / Optimus Enviropro / SIMA Lab/Ion Exchange (q) Two Nos. sludge transfer slef priming monobloc pumps complete with motor and all necessary accessories and fittings fro sludge screw press, Level sensor should b e provided in the sludge holding tank and interlinked with pumps for ON-OFF operation as per level in the sump. One pressure gauge for each pump has to be provided to measure pressure at the outlet. MOC : Cast Iron Type : Centrifugal monobloc self priming Qty : 2 Nos (1W +1), Make : Kirloskar/Johnson/Willo/KSB (r) One No. Continues feed sludge screw press with dosing system for sludge dewatering system as specified in PS. Qty : 01 Nos, Make : Huber/ FKC Screw/ Adys/ AMCON (s) Two Nos. Electromagnetic flow meter, Make : Crohne Marshall /IOTA/ Electronet (t) One set of multiple parameters analyser for BOD/ TSS/COD / pH as specified in PS, complete with software and PC & printer , Make : Forbes Marshall / TETHYS/ ThermoFisher (u) One set of Chlorine analyser for monitoring of residual chlorine as specified in PS. (v) One No. electrical control panel for operation of all electromechanical units of sewage treatment plant including PLC based SCADA system. (w) Suitable size Piping & valves of suitable material to interconnect various units of sewage treatment plant, as per approved drawings. (x) Power & Control cables to interconnect various drives and instrumentations with STP panel. (y) Stairs, platform, railing, etc as per approved design.
(ii) STP CIVIL COMPONENETS (a) Construction of civil units for 200 kid Sewage treatment plant as per approved design and drawings escalation leveling etc. (b) Two Nos. Fine bar Screen chamber in RCC construction with design mix concrete of grade M-30 for fine Bar screen, as per approved design and drawing. (c) One No. oil & Grease Trap chamber in RCC construction with design mix concrete of grade M-30, as per approved design and drawing. (d) One No. Equalization tank in RCC construction with design mix concrete of grade M-30, as per given specifications to cater for the peak discharge including provision of diffused air to ensure that septic conditions do not occur in tank at all. (e) One No. foundation platform for the plant as shown on drawing. (f) One No. operator cum control panel room not less than 20 Sqm with toilet facility as per approved. (g) Treated water tank RCC construction as per approved design and drawing.
Mecone Construction Contractors
JAIN BUILDER
Jatan Constructions Private Limited
Agarwal Jagdish Construction Company Pvt. Ltd.
PUSHKARRAJ CONSTRUCTION PRIVATE LIMITED
Kool Home Builders
Hariom Projects Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid