Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹8.7 L+₹86,745 (11.0%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN LOWEST | |
| 3 | L3₹9.2 L+₹1.4 L (17.4%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN LOWEST | |
| 4 | L4₹9.2 L+₹1.4 L (17.6%)Rejected-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-AOC OTHER THAN LOWEST | |
| 5 | L5₹10.1 L+₹2.3 L (28.9%)Rejected-AOC 137 MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-AOC OTHER THAN LOWEST |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
11 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(NORTH) MAMUN
MAMUN PATHANKOT
REPAIR/REPLACEMENT OF CONVENTIONAL INTERNAL LIGHT FITTINGS and FIXTURES AT OTM ACCN UNDER AGE E/M II OF GE (N) MAMUIN
2020_MES_344795_1
GE(N)/M- /2020-21
Open Tender
Civil Works
Lump-sum
180 days
MAMUN
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(NORTH) MAMUN
₹40,000
Yes
12 Sept 2020
14 May 2020
13 Jun 2020
14 May 2020
11 Jun 2020
28 May 2020
60 days
Amount
Taking down carefully unsv/damaged copper/aluminium surface (batten/conduit or casing caping) point wiring for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets, bracket/sketch filling etc) and removing material from site and making good to the disturbed surface to match with existing finish etc complete all as specified and directed.
Point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable 1.5 sqmm including 1.5Sqmm FRLS PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit for light and fan of not less than 25 mm dia and 1.8 mm thick including all fitting viz tees, bend, junction box and polycarbonate rectangular box for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of suitable size, connecting earth including cutting groves for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes tomatch existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc (Conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible), for light/fan / exhaust fan point etc complete all specified and directed
All As per Srl Item No 2 above but 5 pin 5 Amp socket outlet point on independent board controlled by one switch 5 Amp one way, etc complete all as specified and directed.
All As per Srl Item No 2 above but 5 pin 5 Amp socket outlet points controlled by one switch 5 Amps one way on same board etc complete all as specified and directed.
All as per item No 2 above but one light point controlled by two, two way switches, etc complete all as specified and directed.
All As per Srl Item No 2 above but using 2.5 sqmm (nominal area) multistranded copper conductor cable & 2.5 Sqmm size FRLS PVC insulated and unsheathed copper conductor cable as earth conductor (Green colour) for one 6 pin socket outlet 15 Amp multipurpose independent point controlled by 15 Amp switch SP, one way, 24 Volts, complete all as specified and directed.
Point wiring using FRLS PVC insulated unsheathed/ multi stranded copper conductor cable 1.5 Sqmm including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor earth wire drawn through existing conduit fixed on surface of wall / ceiling with Polycarbonate rectangular box mounting switches, sockets, fan regulators etc with 3mm thick plastic laminated sheet cover of suitable size, connecting earth including connection of cable with MCBs or bus bar shall be done trough proper size copper/brass thimble of pin/u type, for light / fan / bell point including taking out unserviceable point wiring including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets, bracket/sketch filling etc) and removing material from site etc complete all as specified and directed.
All As per Srl Item No 7 above but 5 pin 5 Amp socket outlet point on independent board controlled by one switch 5 Amp one way, etc complete all as specified and directed.
All As per Srl Item No 7 above but 5 pin 5 Amp socket outlet points controlled by one switch 5 Amps one way on same board etc complete all as specified and directed.
All as per item No 7 above but one light point controlled by two, two way switches, etc complete all as specified and directed.
All As per Srl Item No 7 above but using 2.5 sqmm (nominal area) multistranded copper conductor cable & 2.5 Sqmm size FRLS PVC insulated and unsheathed copper conductor cable as earth conductor (Green colour) for one 6 pin socket outlet 15 Amp multipurpose independent point controlled by 15 Amp switch SP, one way, 24 Volts, complete all as specified and directed.
S&F Switch piano flush type, single pole, 5 Amp, one way, AC 230 volts etc complete, all as specified and directed.
S&F Switch piano flush type, single pole, 5 Amp, two way, AC 230 volts etc complete, all as specified and directed.
S&F Switch piano flush type, single pole, 15 Amp, one way, AC 230 volts etc complete, all as specified and directed.
S&F Socket outlet, 2 in 1, 3 pin, 5 Amp, flush type, AC 230 volts etc complete all as specified and directed
S&F Socket outlet, 2 in 1, 3 pin, 5 Amp & 15 Amps, flush type, AC 230 volts etc complete all as specified and directed
S&F Ceiling rose polycarbonate isolated body surface Bakelite4, three terminals, AC 230 volts etc complete all as specified and as directed.
S& F stepped type electronic fan regulator hum free socket type upto 100 watt suitable control the speed of fan 0-100% 230 volt complete all as specified and directed
S&F in replacement Sub main wiring with PVC insulated unsheathed 2X6 sqmm multistranded copper conductor cable 1100 V drawn through & including PVC concealed conduit with 1X6 sqmm PVC insulated green copper cable for continuous earth, PVC conduit not less than 25 mm dia & 1.8mm wall thickness with all accessories including cutting grooves and making good disturbed surface to match existing including taking down existing surface sub main wiring etc complete all as specified and directed.
S&F in replacement of 28 watt electronic ballast heavy duty in sleek housing with lead in wires for easy connection suitable for T-5 FTL fittings of any make/pattern including taking out existing unserviceable ballast etc complete all as specified and directed. Make : Cat Part No H05140 of Wipro or equivalent of Bajaj/Philips.
S&F in replacement of 28 watt rod 4 feet long heavy duty suitable for T-5 FTL fittings of any make/pattern including taking out existing unserviceable rod etc complete all as specified and directed.Make : Wipro/Bajaj/Philips.
S&F in replacement SPN MCB DB 4 way sheet metal enclosures double door 230 V AC, 50 Hz AC complete all as specified and directed.Make- Legrand/HPL/Schneider
S&F in replacement Double door pre-wired MCB DB made out of CRCA sheets, powder coated with copper bus bar SPN 240 Volts, 8 ways double door openable complete, including taking out old unsv MCB DB of any ways/type, etc complete all as specified and directed. Make- Legrand/HPL/Schneider
S&F in replacement SPN MCB DB 12 way sheet metal enclosures double door 230 V AC, 50 Hz AC complete all as specified and directed.Make- Legrand/HPL/Schneider
S&F in replacement Double door MCB DB TPN ,415 Volts 4 way made out of CRCA sheets, powder coated IP 43 protection with copper bus bar taking out old unsv MCB DB of any ways/type, etc complete all as specified and directed. Make L&T/Schneider/HPL
S&Fin replacement Double door VTPN vertical DB, 415 Volts 4 Way(8+12 modules) made out of CRCA sheets, powder coated with copper bus bar double door openable complete as per IS8623-III, impact resistance IK09,X160 for MCCB incommer and SP/TP MCB as outgoing, with accessories 160 Amp rated copper bus bar, blanking plate cable management kit ec,conforming to IP 43 etc complete all as specified and directed. Make L&T/Schneider/HPL
S&F in replacement High efficiency LED linear tube 1X18 watt, 6500 K, 230 volts wall mounted with LED batten(Channel) complete with all accesssories internely pre wired and including connecting up with three core twisted flexible copper conductor cable of suitable size.Cat Part No- For LED lamp LL13-181-650 & Batten (Channel) WIO921208 Make of - Wipro or Make - Equivalent in Havells, Philips, Bajaj and Crompton. Notes : 1. Driver shall be potted antivibration type. 2. LM-79 and LM-80 test report with 1 lakh burning hours LED life from NABL lab shall be provided . 3. CRI (Colou Rendering Index) of fixture shall be > 70. 4. CCT (Colout Correlated Temprature of fixture shall be 5700+300K. 5. System Lumen Efficacy shall be > 100Lm/W. 6. 10 KV separate surge Protection shall be provided as a part of fitting. 7. 5 years gurantee shall be provided by contractor supported by OEM covering all parts of luminaire. 8. Lenses shall be Modular Type. 9. PCB used shall be MC PCB type. 10. The defect liability period of LED light shall be 05 years from the certified date of completion & the contractor shall replace/repair the defective fitting within 07 days after handing over to contractor for repacement /repair.
S&F in replacement of intenso LXS LED Batten 4 FEET 1X18 watt, 6500 K, 230 volts wall mounted extruded thermoplastic body with PC diffuser in square shape complete with all accesssories internely pre wired and including connecting up with three core twisted flexible copper conductor cable of suitable size.Cat Part No- LD00103058 of - Polycab or Equivalent in Havells, philips, Halonix, Bajaj and Crompton
S&F in replacement of Aelius 20 watt T8 with high Lumen LED Tube with PC cover/PC body CR 1780 , 6500K, PC/PC 4 FEET 230 volts complete all as specified and directed.Cat Part No- LTU0101005 of - Polycab or Equivalent in Havells, Philips, Halonix, Bajaj and Crompton
S & F in replacement LED mirror light, 1 x 7 watt prewired with all accessories including lamp complete with all accesssories internely pre wired and including connecting up with three core twisted flexible copper conductor cable of suitable size.Cat Part No LCL-07-CDL Make of - Crompton or equivalent in Havells, philips, Bajaj
S&F in replacement the Bulk head light fitting LED type 10 watt complete with 10 watt LED and having IP-63 protection and fixing on wall/ceiling complete with all accessories and including connecting up with ceiling rose with & including PVC insulated and overall sheathed flexible copper conductor cable and including 3 core 0.50 Sqmm complete all as specified and directed. Cat part No PLT0101316 of Polycab and cat part No HLBH-02-10-CW of Halonix or equivalent in Wipro.
S&F LED Building light 1x25 watt made out of pressure die-cast aluminium with polycarbonate LENS for cover IP65 protection including 32mm bore GI pipe bracted mounted using clamps, nuts bolts, washers, fastners etc. Complete all as specifed and directed .Make Cat part No LR02-291-XXX-57-XX of Wipro or equivalent Halonix/Havells
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F LED lamp 12 watts 230 volts retfrofit suitable for any type lamp holder as required.
S&F in replacement MCB single pole with neutral 240 volts 40 Amps, 10KA (B-series) etc complete all as specified and directed.
S&F in replacement MCB single pole with neutral 240 volts 63 Amps, 10KA (B-series) etc complete all as specified and directed.
S&F in replacement MCB single pole with neutral 240 volts 32 Amps, 10KA (B-series) etc complete all as specified and directed.
S&F in replacement MCB Single pole 240 volts, 6 to 32 Amps, 10KA (B-series) etc complete all as specified and directed.
S&F in replacement MCB single pole 240 volts 40 Amps, 10KA (B-series) etc complete all as specified and directed.
S&F in replacement MCB TPN 63 Amp 415 Volts 25 KA complete all as specified and directed.
S&F in replacement MCB TPN(Four Pole) 100 Amp 415 Volts complete all as specified and directed.
S&F in replacement MCCB TPN 100 Amp 415 Volts 25 KA complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 15mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre. 2. Earth filling shall be done by vegetable soil. 3. Soil should be free from stone, boulders, aggregate, gravels etc.
M/S J N TRADERS
M/S BHATIA CONSTRUCTION
kailu construction co
M/S DUGGAL CONSTRUCTION CO
M/S INDIAN ELECTRICAL
VIMAL TRADERS AND SUPPLIERS
KULBHUSHAN AGGARWAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .