Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.2 LAccepted-AOC CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | 1 | Accepted-AOC LOWEST BIDDER | |
| 2 | 2₹8.7 L+₹31,595 (3.77%)Rejected-Finance | 2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | 3₹8.8 L+₹45,599 (5.44%)Rejected-Finance | 3 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
7 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AJAY KUMAR SINGH
LAKE VIEW CAMP MILITARY STATION TALBEHAT, PIN-284125
COMPREHENSIVE MAINT OF ZONE -14 OF MIL STN TALBEHAT
2023_MES_621775_1
AGE(I)/TBT/TOK-56/2023-24
Open Tender
Civil Works
Item Rate
335 days
TALBEHAT MIL STN
7 documents required · 7 mandatory
₹500
Yes
AGE I TALBEHAT
₹20,000
Yes
20 Nov 2023
5 Oct 2023
9 Nov 2023
12 Oct 2023
7 Nov 2023
19 Oct 2023
Amount
Easing of door shutters for easy closing / opening tightening of hinges or changing the position of hinges adjustment of tower bolts, sliding bolts with new screws etc complete all as specified and directed by Engr-in-charge.
Easing of window shutters, kitchen cupboard shutters, show case shutter drawers incl fixing of screws adjusting handles, knobs tightening piano hinges incl misc small adjustments complete all as specified and directed by Engr-in-charge.
S&F in repair brass chromium plated tubular towel rail 20mm dia 'D' type 60cm long between flanges all as specified and directed by Engr-in-charge.
Refixing in same opening of shutter of area exc 1 Sqm and n exc 2 Sqm each complete all as specified.
S&F in repair mild steel helical door spring 150mm ordinary rat tail type incl roller and roller plate complete fixed with screws to wooden frames or with welding to steel frames complete all as specified and directed by Engr-in-charge.
S&F in repair aluminium alloy anodized sliding door bolt with hasp staples (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts or extruded sections or cast aluminium alloy length of bolt 250mm complete all as specified and directed by Engr-in-charge.
S&F in repair stainless steel wire cloth 0.36 mm niminal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanized wire staples beads or in steel window complete all as specified and directed by Engr-in-charge.
S&F in repair aluminium anodized barrel tower bolts of extruded section length of bolt 200mm complete all as specified and directed by Engr-in-charge.
S&F in repairs extruded aluminium alloy handles fabricated type 150mm size complete -do-
Hacking out old broken glass (any the size quality or description) from wooden or steel frames glazed all as specified and directed by Engr-in-charge.
S&F 4mm th figured glass pin head type and glazing with oil putty or wooden beads in squares n exc 0.50 Sqmtr each pane complete all as specified and directed by Engr-in-charge.
Petty repairs to leaking water in bib taps, pillar taps stop cock, angle valve, PVC connection waste pipes, float valves, flusing cistern, PVC connection, PVC / GI bend,concealed stop cock, GI pipe joints bottle traps etc of any description by changing the washers/plunger/spidle etc or any other minor accessories to make the system functional complete all as specified and directed by Engr-in-charge.
S&F in repair 15mm bore bib tap fancy type chromium plated long body (concealed) cast copper alloy screwed down for iron pipes or for brass ferrule complete all as specified and directed by Engr-in-charge.
S&F in repair chromium plated mixer for wash hand basin for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe bore pipe complete all as specified and directed by Engr-in-charge.
S&F in repair 15mm bore angle valve fancy type chromium plated cast concealed/surface copper alloy screwed down high pressure screwed both ends for iron pipe or for union all as specified and directed by Engr-in-charge.
S&F PVC connection 15mm size with PTMT nuts of length 450mm Make:- Prayag/Hindware all as specified and directed by Engr-in-charge.
-do- as per item No above but length 600mm all as specified and directed by Engr-in-charge.
S&F in repair chromium plated shower rose fancy type fixed to 15mm bore pipe all as specified and directed by Engr-in-charge.
S&F in repairs PVC waste pipe 32 mm dia complete all as specified Make: prayag
S&F in repairs chromium plated sink coupling 62 mm dia complete all as specified Make: prayag
S&F in repair PVC low level flushing cistern 10 ltrs complete with syphon handle lever float valve and PVC bend incl connecting to ITWC/ ETWC and fixing on wall bracket complete all as specified and directed by Engr-in-charge. Make:- Hindustan/ Parayyware/ Jindal/Prayag/Hindware
S&F repairs vitreous china wash basin white flat back size 550 x 400mm excluding taps, , chain & plug and porcelain stopper but incl brackets ,waste pipes all as specified and directed by Engr-in-charge.
S&F in repairs of 15mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors incliding clamping complete all as specified. complete all as specified and directed.
S&F in repairs of 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors incliding clamping complete all as specified. complete all as specified and directed.
S&F in repairs chromium plated faucet for padestal type WC with 1.00 mtr tube & hook approved by Engr-in Charge. Make-Prayag,Jaqur.
Taking down steel window and repair for opening and closing condition and refix . (glazing and gauzing will be measured saperatly)
S&F Half/quarter turn chromium plated 15 mm bore wall mixture 3 in 1 with provision for over head shower with 115 mm LB pipe & wall flange complete with bend pipe and wall flange, complete all as spfd & directed ,Make: Jaqur.Prayag
S&F Half/quarter turn chromium plated 15mm bore kitchen sink mixture 2 in 1 complete with bend pipe and wall flange, complete all as spfd & directed.
S&F 0.9m to 1.5m bottom door seal brown aluminium frame 38 to 45mm width all as specified and directed.
S&F in repair 150 mm oval shape stainless steel handle fancy type bright finish complete all as specified and directed.
Taking down cement or cement lime plaster on brick wall, ceiling incl. Raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L15mm thick plaster in CM 1:6 on fair surfaces of walls finished even and smooth w/o using extra cement complete all as specified and directed.
M&L for 15mm thick plaster in CM 1:4 on fair faces of brick work or concrete surface finished even and smooth w/o using extra cement complete all as specified and directed.
M&L for rendering in cement mortar (1:3) 10mm thick as in ceiling surfaces finished even and smooth complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall over a coat of primer on surface and applying two coats of oil bound distemper complete all as specified and directed.
M & L preparation new plastered surfaces of walls and providing two coat of cement base paint over a coat of primer complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces and applying three coats of white wash on ceilings complete all as specified and directed.
Dismantling floor, hearth or wall tilling including cement mortar bedding, and rubbish off premises etc complete all as specified and directed.
M & L for Non-skid coloured Ceramic tiles 7 to 8 mm thick ( square /Rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white cement to match with tile laid over and including screed bed or bedding layer of 15 mm thick in CM (1:6), complete all as specified and directed.
All as the item above but as in skirting but tile laid over 10mm thick CM (1:4) plaster complete all as specified.
M&L for coloured Glazed ceramic tiles 450 x 300 x 7mm thick tiles on walls, set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile over and including cement mortar 1:4, 10mm thick plaster complete all as spd & directed.
M&L for Super strong water proofing Tape for seal leakage for AC /GI sheet complete all as specified and directed.Make : Dr Fixit,Finolex or equavalent
M&L for preparing old plastered surfaces on Wall/ceiling applying one coat of white wash complete all as specified and directed.
M&L for preparing old plastered surfaces on Wall/ceiling applying one coat of of oil bound distemper in any colour complete all as specified and directed.
M&L for preparation of old painted surfaces of wood & wood based material of any description over 10cm width or girth and applying one coat of synthetic enamel paint (ist quality) complete all as specified and as directed.
M&L for preparation of old painted surfaces of steel and iron work of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
S&F of Solid FRP man hole cover of size 76cmx76cm with handle weight not less than 20kg fitted to manhole any type and icluding demolition of old RCC covers complete all as specified and as directed. Make : Fluton polymers/Sigma or as equivalent brand all as specified and directed. Note: All debris obtained from demolition shall be removed 1.5km to 2km complete all as specified and as directed.
M & L for attending of sewage complaints for blockage of WHB, WC, Urinals, Sinks, bottle trap, floor trap, Nahani traps, WC gully trap, vertical CI pipe/PVC pipes of any dia including junction holes of any description in the AOR of AGE(I) Talbehat. with and including petty repairs items/materials i.e. screws, washers, plugs, grease etc., cutting of grass, vegetation, shrubs etc., digging out roots completely by crow bars, chisel etc., cleaning of sewer/rain water pipelines with manholes laid in any situation for cleaning and removing blockage from entire system and making it fully functional and removal of sludge / mud , complete all as directed. Note : Any major item/material which are required to be replaced shall be paid under respective item of this schedule. The cost of minor items like nails / screws / hexa blades / washers / plugs / grease etc. shall be deemed to be inclusive in the quoted rates only.
Cleaning and removing of blockage of any type of sludge /efflucent etc in sewage line any dia including affected manholes and disposal of waste materials / spoils upto a distance of 50 mtrs by any means maually with the help of green bamboo or any other mechanical method including washing out manhole and sewage line and disposal of waste / sludge in pits complete all as specified and directed.
NOTE - All the (i) sewage complaints/External/Internal Electric complaints will be addressed and rectified within 6 Hrs (ii) External/Internal water supply complaints same day with in 12 hrs (iii) Other repair w/o cement work with in 48 hrs from the time of receipt of complaint. If, contractor or his tradesmen fails to attend and rectify the complained within 24 hrs from the time of receipt of complaint, the compensation/penalty of Rs. 100.00 (Rupees Fifty only) per complaint per hr. for first 02 hrs. and after that Rs. 500.00 (Rupees One Hundred only) per complaint per hr. shall be recovered from the contractor’s dues. Note:- Each time cleaning of blockage shall be paid and measured separately.
Taking down cement plaster on brick or stone walls, etc incl racking out joints , hacking for key , scrubbibg down with water etc.complete all as specified and directed. Note: All debris obtained from taking shall be removed 1.5km to 2km complete all as specified and as directed.
Rendering 15mm on fair faces of brick work finished even and smooth without using extra cement in CM (1:4) mixed with liquid water proofing compound as per manufacturer instructions complete all as specified and as directed. Note:- Liquid water proofing compound shall be measured and paid seperately.
S&F in repairs Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. Note: All debris obtained from demolition shall be removed 1.5km to 2km complete all as specified and as directed.
M&L PCC (1:4:8) type C-2 (using 20mm graded stone aggregate) 100mm thick as in sub bases/ floors all as specified and directed.
Machine pressed precast concrete interlocking paver block with grey cement pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade of approved quality,laid over and include 50mm thick sand cushion vibtrated with mecanical vibrator complete all as specified and as directed.
M&L PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in band,beam,benching of drain,man hole,coping,slightly rounded or chamfered angles and throating,and similar work including necessary form work all as specified and directed.
Demolition of brick work or stone / boulder masonary,built in cement mortar incl all quoins , pillars etc complete all as specified and directed.
M&L for brick work with old size sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed.
M&L for repair of pot holes with ready mix bitumen patchment with 6mm graded stone aggregate and binder asv bitumen not less than 6% by weight. Cleaning the surface by brushing and removing all the loose material and laying loose bobitumen patchment, levelling compacting and well ramming to match with existing surfaces complete all as specified and as directed by Engr-in-charge.
Providing precast ce- ment concrete type C11:3:6 (20mm graded stone aggregate) Kerb srone with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to match complete all as specified and as directed
Supply and fixing cat eye solar reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instructions complete all as specified and directed.
Supply and fix solar cat eye aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) ofhigh efficiency Mono rystafie solar panel 2.4V/0.3 watt one NI-ed rechargeable battery (1.2V/1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc. all as specified and directed.
M&L for Surface dressing n exc 15 cm deep soft/loose soil complete all as specified and as directed
M&L for 50mm Spread thickness Moorum/Red bajri, spread, rolled and consolidated to gradient and camber required complete all as specified and as directed by Engr-in-charge.
Taking down carefully copper/Aluminum point wiring (light/fan/socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc., removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors etc. complete all as directed.
M/L for point wiring concealed type with 1.5sq mm FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl FRLS PVC rigid conduit not less than 20 mm dia with its accessories pressed steel terminal box incl 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators etc for the following: Wire: Make -Mescab/Polycab/KEI/Havells/Finolex PVC conduit: Make -Polycab/Precision/Plaza/Kalinga Note:- (i) On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit/PVC Casing capping and its accessories. (ii) Cutting of wall, floor, PCC work and white wash for making of good to disturbed surfaces shall be included in the rate quoted.
One light/fan/bell point controlled by one No piano type switch 5 Amps single pole one way
One socket outlet 5/3 pin 6 AMPS controlled by one switch on the same board.
One socket outlet 5/3 pin 6 AMPS controlled by one switch on independent board.
All as per item NO 2 above but 3 pin socket out let 15/16 Amps on the independent Board all as spfd with single core unsheathed PVC insulated cable multistranded copper conductor of size 4 sq mm for phase & neutral & 4 sq mm for earth continuity conductor.
S&F Switch Piano Flush button single pole one way 5/6 Amp. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F Switch Piano Flush button single pole one way 15/16 Amp. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F socket outlet 2 in 1, 5 pin & 2 pin, 5/6 Amp, 240 volt. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F socket outlet 2 in 1 , 5 pin & 2 pin, 5/6 Amp and 15/16 Amp, 240 volt. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F switch socket combination, 5 pin & 2 pin, 5/6 Amp, 240 volt. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
Supply only switch socket combination 3 pin, 16 Amp, flush type.
S&F ceiling rose surface bakelite 65mmx50mm 100watt three terminal. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F step type electronic fan regulator flush type one way on the existing phenolic laminated sheet. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
M&L for sub main concealed wiring with two single core PVC insulated of size 1.5 sqmm FRLS unsheathed copper conductor 1100 volt grade multistandard and incl drawn through exisiting non metallic rigid PVC conduit and conduit accessories of 20 mm external dia and conduit FRLS accessories of ISI marks medium grade including 1.5 sqmm FRLS copper wire for earth continuity wire and connected of common earth dolly. Wire: Make Mescab/Polycab/KEI/Havells/Finolex (i) Two run of 1.5 sq mm copper conductor & one run of 1.5 sq mm copper conductor is measured as one unit.
M&L for MS nut bolts and washers any kind any description as per site requirement complete all as specified and directed.
M&L for replacement of ACSR conductor Rabbit for OH line complete all as specified and directed.
Re-stretching of LT/HT OH line ACSR conductor of any size upto suitable sag point including GI wire of any size complete all as specified and directed.
M&L for replacement of Pin insulator for LT OH line complete all as specified and directed.
M&L for replacement of shackle insulator for LT OH line complete all as specified and directed.
M&L for UG cable XLPE insulated heavy duty electric cables with Stranded alluminium conductor, 1100 volts grade, passing through trenches/ducts/pipes and climbing on poles/walls including fixing with proper size of alluminium lugs complete all as specified and directed of the followings. NOTE:- 1. Excavation and earth work to be measured and paid separately.
10 Sq mm 2 Core
10 Sq mm 4 Core
16 Sq mm 4 Core
Excavation in trenches in soft/disintegrated rock/hard dense soil etc n. exc 1.5 m wide and n.exc 1.5m in depth for foundation etc or for shafts, manholes, pier holes etc n.exc 10 Sqm on plan and n.exc 1.5 meter in depth and getting out complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm each layers complete all as specified and directed.
Removal of excavated material & surplus spoil n. exc 50 m to a distance and depositing where directed at a level n.exc 1.5 meter above the starting point complete all as specified and directed.
M&L for spreading M-sand cushioning to underground cable in layers of 23 cm (8 cm deep before laying of cable and 15cm deep over the cable) after laying the cable in trenches including punning thickness up to 18 cm complete all as specified and directed. Note: - Only punned thickness will be considered for payment.
Supply and laying Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm for cable protection laid length wise perpendicular to the axis of cable complete all as specified and directed.
M&L for Scraping the existing old surface of panel boards and painting with one coat of primer and two coats of yellow paint and marking of accessories fixed in panel boards standard size of letters complete all as specified and directed.
Supply and fixing pipe galvanized, light grade with all fittings fixed to walls and ceiling or laid in floors complete all as specified and directed of size 50 mm dia complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate as in couping of poles etc including fair finishing the exposed surface even and smooth with out using extra cement and necessary form work all as specified and directed
Supply, fixing and testing high performance LED Street Light fittings luminaries of 70 Watts, Built-in-Surge Protection Device including bracket hook type and 3.0 m long 40 mm dia med grade GI pipe with MS clamp and nut bolts complete all as specified and directed, MAKE : Havells /Philips/CG/Halonex
Excavation in soft/loose soil trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep and getting out for repairing/ replacement of DI/CI/GI pipe line complete all as specified and directed.
Returning, filling in & including spreading, levelling & well ramming in layers not exceeding 25 cm thick as in soft/loose soil complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtr depositing where directed at a level not exceeding 1.5 mtr above ground level complete all as specified and directed.
Demolition of hard standing/road for crossing of pipe line as per the authorized width for taking out/laying/cleaning/repairing of CI/GI pipe lines all as directed including making good the disturbed surfaces and cut to match with the existing surface either with bituminous macadam or with PCC 1:2:4, type B-2(using 40mm graded crushed stone aggregate) complete all as specified and directed.
Supply and lay steel water tubing GI medium grade ISI marked with all necessary fittings and fixtures (Socket, elbow, bend, nipple, union etc) laid in trenches or fixed to wall etc including taking up or down old unserviceable pipe line complete for the following sizes:- Make: Jindal/Prakash/Swastik/TATA Note :Excavation and earth work will be measured and paid separately.
(a) 25 mm dia bore
(b) 20 mm dia bore
S&F Gun metal gate valve ISI marked with iron wheel head screwed both ends for iron pipes and fixed for the following sizes including taking down of unserviceable gate valves:-
(c) 25mm bore
(d) 20mm bore
M&L for Ball valve high pressure of PTMT of size 20mm dia with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
M&L for Ball valve high pressure of PTMT of size 25mm dia with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
M&L for PCC 1:4:8, type D-2 using 40mm graded stone aggregate, brick work in cement mortar 1:6, plastering in cement mortar 1:4 (internally) including demolition complete all as specified and directed.
M&L for 15mm thick external plastering in CM 1:4 on fair faces of brick work or concrete surface finished even and smooth without using extra cement including demolition complete all as specified and directed.
S&F MS plate or angle, channel, square cut or notched with riverted bolted or welded attachment including taking out complete all as specified and directed.
Taking down old unserviceable light fittings of any type and wattage.
Repair only LED Solar street light fitting all in one type 09 ro 12 watt, 12 volt DC IP 65, cleaning of panels, and wiring as required complete all as specified and directed
Replacement of 12 V inbuilt battery, lithium ferro phosphate for solar street light
Supply and fixing in replacement of LED Solar street light fitting 11/12 Watt 12 volt DC IP 65, including inbuilt 12 V battery and auto lighting time sensor complete all as specified and directed.
Supply and fixing in repair Solar light Panel 12 volt 50 watt complete all as specified and directed.
Supply and fixing in repair and testing ALL-IN-ONE Solar street light with high efficiency mono crysalline solar PV module, Lithium Ferro phosphate battery with inbuilt BMS technology, high efficiency LED of 12 watts, MPPT solar charger controller & aluminium extruded body, with Progressive intelligent dimming, backup for 02 days including mounting pole 6.0 m long, 50 mm dia med grade GI pipe with MS clamp and nut and bolt and PCC complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair LED driver 70 to 100 watt for street lights/ Flood light complete all as specified and directed.
Note :- Debris obtained from all items should be removed in low lying areas as directed by Engr-in-charge out of MOD Land. (Rates quoted for items are deemed to be included for this, where removal of debris in the items is not considered.)
M/S R.S.BUNDELA & SONS
M/s Indu Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .