Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-Finance | ₹25.4 L | L1 | Accepted-Finance Being L1 |
| 2 | L2₹26.1 L+₹69,273.97 (2.73%)Rejected-Finance 1ST FLOOR GURJEET MARKET DHANGU ROAD | ₹26.1 L+₹69,273.97 (2.73%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹26.8 L+₹1.4 L (5.58%)Rejected-Finance H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹26.8 L+₹1.4 L (5.58%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹27.7 L+₹2.4 L (9.37%)Rejected-Finance OLD SABZI MANDI PATHANKOT M S NORTHERN INDIA CONSTRUCTION CO DHANGU ROAD VILLAGE TOWN PATHANKOT CITY PATHANKOT PATHANKOT PUNJAB 145001 INDIA | PATHANKOT | PUNJAB | 145001 | ₹27.7 L+₹2.4 L (9.37%) | L4 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | Vijay Kumar Contractor and Engineers L2 | M/s Shakti Electric Works L3 | KLM Enterprises L1 | M/s Northern India Construction co L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down old/unserviceable security light fitting, Avaition light fitting, flame proof light fittings and bulk head light fitting, of any type and make, from electric pole, roof /wall of the bldgs or any location any capacity from any height any situation, repairs to the extent by removing connections from the system checking of unserviceable spare parts and serviceable parts , replacement of unserviceable parts with new spares and testing complete, tightening the loose connection and made it functional, reassembling the fitting including re-fixing/ re-hanging the same after repair in existing location or other location (as directed) including replacement of three core copper cable of size 1 Sqmm and tesing complete all as specified and directed by Engineer-in-Charge. Note : i)Spares required for repair (except connection cable) shall be measured and paid separately as supply only items here-in-after and the cost of connection cable shall be deemed to be included in the quoted rates. (ii) If complaint not completed within the days then Rs 100/- of penelty will recovered for per compalint/per day | 440 | Each | 50 ₹22,000 Lowest | 300 ₹1,32,000 | 70 ₹30,800 | 100 ₹44,000 |
| 2.00 | Supply & fix in replacement electronic driver suitable for LED light fitting 60 to 150 wattt, 240 volts as recommended by OEM complete all as required at site and all as specified and directed by Engr-in-charge | 260 | Each | 100 ₹26,000 Lowest | 200 ₹52,000 | 250 ₹65,000 | 120 ₹31,200 |
| 3.00 | Supply & fix in replacement surge protection 10KV suitable for LED light fitting 60 to 150 watt complete all as required at site and as s directed by Engr-in-charge Make : Wipro/Bajaj/Philips/CG | 40 | Each | 150 ₹6,000 | 200 ₹8,000 | 130 ₹5,200 Lowest | 150 ₹6,000 |
| 4.00 | Supply & fix in replacement cable junction box with 3 No SP terminals, with IP 66 protection made of DK thermoplastic, weather proof, shock proof, halogen free for hazardous areas with internally embedded gasket and metric knock outs for cable entry suit | 55 | Each | 500 ₹27,500 | 250 ₹13,750 Lowest | 800 ₹44,000 | 300 ₹16,500 |
| 5.00 | M&L complete for repair to operating panel of high mast light including replacement of contractor, coil and timer or any defective spares/items as required at site for making complete serviceable including testing for satisfaction to the Engr-in-charge | 3 | JOB | 3,500 ₹10,500 Lowest | 4,000 ₹12,000 | 3,500 ₹10,500 Lowest | 4,500 ₹13,500 |
| 6.00 | Supply & fix in replacement street light fitting, powder coated, pressure die cast aluminium IP 66, 120 watt with 100Lm/watt compact LED light with heat resistant toughened glass with lens, complete and making connection from junction box to fitting in PVC conduit by using PVC cable with copper conductor of size 2.5 Sqmm 3 core,fixing in existing brackets with required addition/alteration if any complete all as directed and specified | 28 | Each | 4,000 ₹1,12,000 Lowest | 4,200 ₹1,17,600 | 4,150 ₹1,16,200 | 4,000 ₹1,12,000 Lowest |
| 7.00 | All as per srl item No 6 here-in-before but 90 watt. | 23 | Each | 3,500 ₹80,500 | 3,000 ₹69,000 | 1,800 ₹41,400 Lowest | 3,500 ₹80,500 |
| 8.00 | All as per srl item No 6 here-in-before but 60 watt. | 23 | Each | 2,500 ₹57,500 | 2,800 ₹64,400 | 1,500 ₹34,500 Lowest | 2,300 ₹52,900 |
| 9.00 | Taking down old unsv cable /submain off size from electric pole/ bldgs & stacking at site all as directed by engr -in-charge | 2,130 | RM | 10 ₹21,300 | 30 ₹63,900 | 5 ₹10,650 Lowest | 5 ₹10,650 Lowest |
| 10.00 | Supply & fix in replacement of cord flexible PVC insulated and over all sheathed, three core, flexible copper conductor of size 2.50 sqmm all as required at site. Make : Standard/ Havelles./Grandlay/Havells/Polycab/plaza | 358 | RM | 35 ₹12,530 | 40 ₹14,320 | 65 ₹23,270 | 25 ₹8,950 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
3 Jul 2026, 6:00 pmClosed
Sh Vishal Kumar
GE (AF) Pathankot
REPAIR AND MAINT OF MISC E M INCLUDING REPAIR REPLACMENT OF UNSERVICEABLE SECURITY LIGHT FTTINGS, MAINT OF DG SETS DIESEL ENGINE REPAIR MAINT OF ALL TYPE EARTHING AT AF STN DALHOUSIE
2026_MES_770115_1
GE/PAF-58/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Pathankot
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Pathankot
₹80,000
Yes
10 Sept 2026
5 Jun 2026
6 Jul 2026
5 Jun 2026
3 Jul 2026
19 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down old/unserviceable security light fitting, Avaition light fitting, flame proof light fittings and bulk head light fitting, of any type and make, from electric pole, roof /wall of the bldgs or any location any capacity from any height any situation, repairs to the extent by removing connections from the system checking of unserviceable spare parts and serviceable parts , replacement of unserviceable parts with new spares and testing complete, tightening the loose connection and made it functional, reassembling the fitting including re-fixing/ re-hanging the same after repair in existing location or other location (as directed) including replacement of three core copper cable of size 1 Sqmm and tesing complete all as specified and directed by Engineer-in-Charge. Note : i)Spares required for repair (except connection cable) shall be measured and paid separately as supply only items here-in-after and the cost of connection cable shall be deemed to be included in the quoted rates. (ii) If complaint not completed within the days then Rs 100/- of penelty will recovered for per compalint/per day | 440 | Each | - | - |
| 2 | Supply & fix in replacement electronic driver suitable for LED light fitting 60 to 150 wattt, 240 volts as recommended by OEM complete all as required at site and all as specified and directed by Engr-in-charge | 260 | Each | - | - |
| 3 | Supply & fix in replacement surge protection 10KV suitable for LED light fitting 60 to 150 watt complete all as required at site and as s directed by Engr-in-charge Make : Wipro/Bajaj/Philips/CG | 40 | Each | - | - |
| 4 | Supply & fix in replacement cable junction box with 3 No SP terminals, with IP 66 protection made of DK thermoplastic, weather proof, shock proof, halogen free for hazardous areas with internally embedded gasket and metric knock outs for cable entry suit | 55 | Each | - | - |
| 5 | M&L complete for repair to operating panel of high mast light including replacement of contractor, coil and timer or any defective spares/items as required at site for making complete serviceable including testing for satisfaction to the Engr-in-charge | 3 | JOB | - | - |
| 6 | Supply & fix in replacement street light fitting, powder coated, pressure die cast aluminium IP 66, 120 watt with 100Lm/watt compact LED light with heat resistant toughened glass with lens, complete and making connection from junction box to fitting in PVC conduit by using PVC cable with copper conductor of size 2.5 Sqmm 3 core,fixing in existing brackets with required addition/alteration if any complete all as directed and specified | 28 | Each | - | - |
| 7 | All as per srl item No 6 here-in-before but 90 watt. | 23 | Each | - | - |
| 8 | All as per srl item No 6 here-in-before but 60 watt. | 23 | Each | - | - |
| 9 | Taking down old unsv cable /submain off size from electric pole/ bldgs & stacking at site all as directed by engr -in-charge | 2,130 | RM | - | - |
| 10 | Supply & fix in replacement of cord flexible PVC insulated and over all sheathed, three core, flexible copper conductor of size 2.50 sqmm all as required at site. Make : Standard/ Havelles./Grandlay/Havells/Polycab/plaza | 358 | RM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
Tender.pdf
Tender Documents • 0.86 MB
BOQ_862423.xls
BOQ • 0.61 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .