Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹35.0 L+₹1.1 L (3.22%)Rejected-Finance | L2 | Rejected-Finance HIGHEST |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
1 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI TC SHISHODIYA, DCWE (C)
MULATN LINE ARMY AREA JODHPUR
Repair and Maintinanace of HT Over Head Line, UG Cables Transformers, VCB and connected items at Army Area Banar
2021_MES_419324_2
CWE (A) JODH/BNR-137 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE Banar
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
Yes
GE Banar
₹70,000
11 Aug 2021
10 Apr 2021
3 May 2021
10 Apr 2021
1 May 2021
17 Apr 2021
60 days
Amount
Taking down and servicing for HT switch gear VCB of capacity 400-630 Amp capacity ,11KV by tripping off the breaker and draw out the trolley and servicing and overhauling the mechanical parts with applying the grease and checking the control wiring and tripping mechanism, replacement of damaged minor parts such as control wiring, ferrules, HRC fuse, caliberation of IDMT/Microprocessor numerical/digital relay existing on panels with secondery injection kit and setting the relay of earth fault, short circuit, time delay settings as per existing load of feeder and all as specified and direted by engr-in-charge at 33 KV MRSand depot area.
Taking down and servicing for HT switch gear VCB of capacity 400-630 Amp capacity ,33KV out door type including control remote panel by tripping off the breaker servicing and overhauling the mechanical parts with applying the grease and checking the control wiring and tripping mechanism, replacement of damaged minor parts such as control wiring, ferrules, HRC fuse, caliberation of Microprocessor numerical/digital relay existing on panels with secondery injection kit and setting the relay of earth fault, short circuit, time delay settings as per existing load of feeder and all as specified and direted by engr-in-charge at 33 KV MRS.
Taking down and servicing for HT switch gear RMU of 2/3/4 way ,11KV out door type tripping off the breaker servicing and overhauling the mechanical parts with applying the grease and checking the control wiring and tripping mechanism, replacement of damaged minor parts such as control wiring, ferrules, HRC fuses etc, caliberation of Microprocessor numerical/digital relay existing on panels with secondery injection kit and setting the relay of earth fault, short circuit, time delay settings as per existing load of feeder and all as specified and direted by engr-in-charge.
Material and labour for the vacumeinterruptor of existing VCB's of any make and connecting arrangement including taking down and all as required and directed at site by Engr-in-Charge.
Supply and fixing in replacement of tripping coil suitable for VCB 400 to 630 Amps to trip the VCB with the operating voltage of 24 vols DC supply and all as specified and directed.
Supply and fixing, testing , commissioning in replacement of microprocessor relay of 24 volts DC supply operated with earth fault ,over current and with TDS to protect the HT VCB of 400 to 630 Amps alongwith control wiring of CT primary/secondary winding and all as specified and directed.
Taking out the HT UG cable by disconnecting the existing electric connection and shifting the cable one lacation to another location safely for relaying the same in side the depot area and all as specified and directed at site. Note : i). Earth work and protection pipe etc shall be measured and paid separately. ii). Outdoor/indoor cable end terminatioin/straight through joints shall be measured and paid separately.
Supply, laying, jointing and testing XLPE insulated PVC outer seathed and (earthed) PVC inner sheath, galvanised steel strips armoured, heaving duty power cable with aluminium conductor suitable for rated voltage of 11000 Volts grade Earthed system and conforming to IS : 7098 (Part-II) of 1985 and size 120 sqmm 3 core and laid in treches/ducts/pipe or on read/pole all as required and directed at site. Note : i). Earth work and protection pipe etc shall be measured and paid separately. ii). Outdoor/indoor cable end terminatioin/straight through joints shall be measured and paid separately.
Material and labour plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of the pole or in any situation including necessary formwork all as specified and directed.
Supply installation, commissioning and testing 11 KV outdoor type, gang operated Air break switch 200 Amp rated triple pole mechanically operated with drop out fuses, mounted on insulator and steel frame with operating mechanism worked from ground level with 25mm GI pipe (Med grade) operating rod of suitable length with expulsion fuses of rating upto 200 Amp comprising of 12 insulators all as specified and directed.
Material and labour for earthing complete with galvanised iron earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.5 meter deep below ground level) with top edge of the plate not less than 1.75 meters below normal ground level connection to galvanised iron strip 32 x 6 mm as earthing lead by means of steel bolts, nuts, check-nuts and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work (transformer neutral, transformer body and LT/HT panel body) including supply and laying charcoal dust and common salt mixture all around the plate 300 mm thick chamber PCC : 1:2:4 type B-1 MS angle iron frame 40x40x3 mm and RCC cover 40mm thick (1:2:4) type B-1 using 20 mm stone graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh refilling with vegetable soil without bolders and stones, gravels and aggregate etc and CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to eathing test point all as specified or indicated including testing on completion , 20 mm dia GI pipe light grade for watering all as shown in drawing and connected to LT panel including testing complete all as specified and directed. Note: The earth pit shall be refilled by bolders free vegetable soil all as specified and directed.
Supply, jointing and testing outdoor type heat shrinkable end termination cabale joint kit including all material and accessories suitable for 3 core 120 -185 sqmm cable of 11000 Volt grade all as per manufactuer recommendation complete all as specified and directed.
Supply, jointing and testing indoor type heat shrinkable end termination cabale joint kit including all material and accessories suitable for 3 core 120 -185 sqmm cable of 11000 Volt grade all as per manufactuer recommendation complete all as specified and directed.
Supply, jointing and testing straight through heat shrinkable cabale joint kit including all material and accessories suitable for 3 core50 to 95 sqmm cable of 11000 Volt grade all as per manufactuer recommendation complete all as specified and directed.
Supply, jointing and testing straight through heat shrinkable cabale joint kit including all material and accessories suitable for 3 core120- 185 sqmm cable of 11000 Volt grade all as per manufactuer recommendation complete all as specified and directed.
All T&P expenditure for tracing out the HT UG cable fault by pin point with cable fault locating machine mounted on vehicle including all T&P expenditure to rectify the fault within 24 hrs to restore the supply of HT 11 KV feeder at Banar Mil station and all as sppecified. Note : The fault will be measured one unit by charging of one HT cable , multiple faults at same cable will be measured single fault and HT Cable joints will be measured and paid seperately and earth work will be paid under relevent item of Schedule.
Labour only for relaying the jodhpur stone quarry stone slab including loading from one location to shift other location and unloading within 5KM distance of the cover 25 to 30cm in width, 60cm long and 40 to 50mm thick laid in trenches and abutting each other with gap between adjacent slab not exceeding 10mm over sand covered under ground cables complete all as specified and directed by Engr-in-charge.
S&F in replacement tubes 'light grade' galvanized with all fitting laid in trenches/on wall/pole/under road crossing/under existing bridge with suitable clamps made bt FI 25x3mm if required to fix on wall/pole of size 80 mm dia including all fitting all as specified and directed.
S&F in replacement tubes 'light grade' galvanized with all fitting laid in trenches/on wall/pole/under road crossing/under existing bridge with suitable clamps made bt FI 25x3mm if required to fix on wall/pole of size 100 mm dia including all fitting all as specified and directed.
Supply and fixing cross arms, bracings, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holesfor bolt. In any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint and all as specified and directed.
Cutting the road / hard standings and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by means of PCC 1:2:4, type B1 using 20mm graded stone aggregate complete and matching with the surroundings all as directed.
S&F Pin type, pocelain, vitreous, white brow or green insulator including one galvanised mild steel spindle, two galvaanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade with fixing on existing 2 pole/4pole/single pole including taking down of old unsv insulator and all as specified and directed.
S & F Aluminium conductor steel reinforced (ACSR) confirming to IS : 398 Part II 1976 for HT/LT over head line and for jumpering including PVC insulation material for jumpering on HT PCC/Steel pole 2/4 pole structure with suitable size of lugs and nut bolts to connect to GOD back plate or Do assembly and including alumunium binding wire and suitable size of GI clamp complete all as specified
Supply and fix danger notice plate 1.6 mm thick mild steel sheet vitrous enamelled white with latters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of appropriate size for 11 KV system size 25 x 20 cm all as specified and confirming to to IS : 2551-1982.
Supply fixing and connecting and testing single pole zinc oxide (gapless surge type) heavy duty transmission class, self supporting outdoor type lighting arrester having rated voltage 09 KV (rms) discharge corrent 65 KA insulation level 28/75 KV/KVP (Peak) suitable for rated system voltage of 12 KV supply system with maximum continuous operating v oltage (MCOV) not less than 7.65 KV (rms) with highly non linear ceramic resister made of zinc oxide in thermatically sealed container complete with metal base, base inculator and suitable terminals for ground connections and pressure relieving arragement complete all as specified Note : The rate quoted against above item shall include necessary fixing arrangement of lightening arresster on two pole/four pole structure as per recommendations of manufactures.
Supply fixing and connecting and testing single pole zinc oxide (gapless surge type) heavy duty station class, self supporting outdoor type lighting arrester having rated voltage 09 KV (rms) discharge corrent 65 KA insulation level 28/75 KV/KVP (Peak) suitable for rated system voltage of 12 KV supply system with maximum continuous operating v oltage (MCOV) not less than 7.65 KV (rms) with highly non linear ceramic resister made of zinc oxide in thermatically sealed container complete with metal base, base inculator and suitable terminals for ground connections and pressure relieving arragement complete all as specified Note : The rate quoted against above item shall include necessary fixing arrangement of lightening arresster on two pole/four pole structure as per recommendations of manufactures.
Excavation in trenches in any type of soil not exc 1.5 mtr in depth and 1.5 mtr wide and getting out for laying of cables.
Returning and filling in soil including spreading, leveling , watering and well ramming in layers not exceeding 25 cm thick of excavated earth complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing at a leval not exceeding 1.5 mtrs above the starting point complete all as specified and directed.
M&L for tibba sand filling in trenches dry and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified and directed.
M&L for laying jodhpur stone quarry stone slab cover 25 to 30cm in width, 60cm long and 40 to 50mm thick laid in trenches and abutting each other with gap between adjacent slab not exceeding 10mm over sand covered under ground cables complete all as specified and directed by Engr-in-charge.
Disconnecting of HT/LT side connection of indoor/out door type of trnsformer after disconnecting electric supply opening/ disconnecting the foundation earth and neutral connection out side of the transformer and taking down the transformer any capacity up to 400 KVA from2/4 pole sturcture or on PCC plat form including loading transportation and unloading to workshop/ factory drainning out of transformer oil and keeping aside to avoid dust and moisture complete all as specified and directed.NOTE:- (i) The rate quoted for this item deemed For lifting and shifting the transformer will be done by crane where ever posible to lift with crane
All as per Item No 32 above but 500 to 1200 KVA indoor/out door type transformer.
M&L for Opening of transformer cover and all other connected accessories taking out the transformer oil from tank taking out core assembly disconnecting the core and taking out unserviceable HT/LT coil after opening/ dismentaling all connection inside the transformer capacity up to 400 KVA complete all as specified and directed NoteI i) Centrifuging of transformer oil shall be measured and paid seperately ii) Repair work of transformer shall be measured and paid seperaetely (iii).The transformwer rewinding work shall be carried out at certified renowned workshop/ company (iv) The all type of transformer tests are willbe carried out before installing the rewounded transformer in the presence of Engr-in-Charge.
All as per above item No 34 but capacity 500 to 1200 KVA
Supply and fixing /winding fabricated DPC copper strip of suitable guage/size and required shape for windng of LT coil of transformer up to 1000 KVA incliding necessary ovening and insulation material compelete all as required an directed.
All as per Item No 36 above but using DPC copper wire of double insulated suitable size/ guage and shape for rewinding of HT coil including necessary insulaion material complete all as required and directed .
S&Fin replacement of unserviceabile porceline vitreous bushing of required size / shape (suitable for exisiting transformer ) for spindle of transformer of any capacity upto 400 KVA out door type on 11000 Volts grade of outdoor type siutable for HT side all as specified and directed.
All as per Item No-38 above but 11000 Volts grade suitable for HT side indoor type
All as per Item No-38 above but 1100 Volts grade suitable for LT side indoor type
All as per Item No-38 above but 1100 Volts grade suitable for LT side outdoor type
S&F in replacement of unserviceable brass spindle duly threded at the end complete with nut bolts and washer suitable for HT side of transformer out door type all as specified and directed at site for the following capacity suitable for existing transformer of required size/ shape for spindle of transformer of any capacity up to 400KVA 11000 volts grade indoor/out door type suitble for HT side all as specified and directed :-63-100 KVA
All as per Srl Item No 42 above but 160-250 KVA
All as per Srl Item No 42 above but 300-400 KVA
All as per item No 42 above but suitable for LT side of transformer of capacity 63-100 KVA
All as per Srl Item No 45 above but160-250 KVA
All as per Srl Item No 45 above but 300-400 KVA
S&F gasket for packing set of any size suitable for transformer of capacity up to 400 KVA made out of 6 mm thick cock sheet single piece including removing old unserviceable packing kit/ set cleaning the surface of the top cover etc complete all as specified and directed.Note :- The cost of opening of transformer cover/ top if required deemed to be included in the item rate of respective item .
M&L for Assembelling the core of transformer making all necessary connection refixing the core in the transformer tank to its original position Baking ,testing the transformer and refixing the top cover and reinstalled transformer at site on PCC plateform/ 2POLE/4pole stucture making all LT/HT connection body earth connection etc including refilling the transformer oil all as specified and directed at site.
M&L for Transporting, installation and making all necessry connection of any capacity up to 400 KVA on PCC plate form or 2 pole/4 pole sturucture from work shop or any location to another location at Banar Army area including loading / unloading or depositing the transformer to E/M yard or other location in the area GE Banar area complete all as specified and directed at site.
M&L for Centrifuging of transformer oil to bring the dielectric strength of transformer oil not less than 50 KV for transformer or HT OCB of any capacity at any site in the Banar Station complete all as directed.
Supply and filling the transformer oil in factorey sealed barrel with IS-336 of di-electric strength not less than 50 KV at 2.5 mm gap and toping up the oil where ever required in A A Banar and all as specified and directed.
Supply and Fixing the transformer silica gel breather complete with all accessories for transformer of any capacity up to 400 KVA all as directed at site.
M&L transformer silica gel complete with all accessories for transformer of any capacity all as directed at site.
Material and labour for replacing the rubber bush packing seal on HT/LT side studs of capacity of upto 500 KVA transformer and ensuring the no laekage of transformer oil including taking out the HT/LT cable connection and refixing the cable after rectifying the leakage of oil and all as specified and directed.
Supply, design, Installation, testing and commissioning of totally enclosed busbar chamber of outdoor type IP-55 protection fabricated out of 3mm thick CRCA sheet dustand vermin proof powder coated double door type including locking arrangement, aluminum bus bar 400Amp rating with air tight insulated mounted on insulators, incoming and outgoing cable chamer suitable for 2 I/C, 2 O/Q, size upto 185 Sqmm complete suitable for operation of 11000 volts grade , 50 hz, AC supply having Angle iron frame with legs of 50Cm height made out of 65x65x6mm angle iron grouted on PCC (1:3:6) and platform should be 50cm above the normal ground level and all as specified and directed.
Supply only the aluminum lugs of long neck type(heavy duty) of aize 10 Sq mm to 300 sqmm and all as specified and directed by Engr-in-Charge.
Supply only the mild steel fully threaded bolts with nut and with one No of washer of various sizes in llength and dia and all as specified and directed by Engr-in-Charge.
Material and labour for scraping the rusted surface/rubbish paint on the surface of transforme and painting the same with grey paint double coat and making smooth finish of trnsformer capacity upto 400 KVA indoor/out doortype and all as specified and directed at site by Engr-in-Charge.
Material and labour for scraping the rusted surface/rubbish paint on the surface of transforme and painting the same with grey paint double coat and making smooth finish of trnsformer capacity 500 to 1200KVA indoor/out doortype and all as specified and directed at site by Engr-in-Charge.
Supply and fixing in replacement of 1100 volts grade HRC fuse barrel type of rating upto 400 Amps suitable for existing VCB/breaker of any make and all as specified and directed by Engr-in-Charge.
All T&P expenditure for testing of power transformer 3.15 MVA of 33/11KV at MRS ABOD Banar, following test shall be carried out at site by calibrated instrument (calibration certificate shall be submitted) complete all as specified and directed by Engineer-in-Charge the test will be carried out at site by arranging the necessary T&P /Eqpt at site. (a). Magnetic balance test (b). IR Test (c). Open circuit test (d). Short circuit test (e). Transformer oil test (Test shall be carried out at govt approved lab) (i). Water content test (ii). Neutralisation value (totla acidity) test.
All T&P expenditure for testing of power transformer 2.0 MVA of 33/11KV at MRS ABOD Banar, following test shall be carried out at site by calibrated instrument (calibration certificate shall be submitted) complete all as specified and directed by Engineer-in-Charge the test will be carried out at site by arranging the necessary T&P /Eqpt at site. (a). Magnetic balance test (b). IR Test (c). Open circuit test (d). Short circuit test (e). Transformer oil test (Test shall be carried out at govt approved lab) (i). Water content test (ii). Neutralisation value (totla acidity) test.
Supply and fixing the HT cable route indicate made by Jodhpur stone well finished and making of letter "DANGER HT 11 KV", size 100mmX100mmX100mm 75 cm long, 15cm grouted with 1:3:6 PCC foundation below the ground level and 60cm of marked will be elevated on ground the embossed letters on DANGER HT 11 KV will be painted with post office red colour and with background and all as specified and directed .
M/S SHREE AAINATH ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .