Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.0 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED DUE TO LOWEST | |
| 2 | L2₹44.7 L+₹69,538.45 (1.58%)Rejected-AOC | L2 | Rejected-AOC REJECTED DUE TO NOT LOWEST | |
| 3 | Rejected-Technical 10 MAKHAN LAL SADHUKHAN LANE PO PS BARRACKPORE KOLKATA 700120 W B | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | - | Rejected-Technical Not enlisted in b(i) category |
Tender Value
₹41.8 L
EMD Value
₹84,000
Closing Date
17 Nov 2022, 6:00 pmClosed
GE (AF) LOHEGAON
GE (AF) LOHEGAON, PUNE -411032
PROVISION OF STATION STORE, PROVISION OF FALSE CEILING IN BUILDING NO. P-136 B AT 9 BRD, PROVISION OF INTERCONNECTING PATH WITH RAIN SHED FROM LDP TO ACMI LAB AT 9 BRD, PROVISION OF VOLTAGE STABILIZER FOR WSA AND PROVISION OF WATER SUPPLY PIPELINE WI
2022_MES_541946_3
8600/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) LOHEGAON
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) LOHEGAON
₹84,000
Yes
20 Jan 2023
22 Oct 2022
24 Nov 2022
22 Oct 2022
17 Nov 2022
5 Nov 2022
Amount
Surface dressing not exceeding 15cm deep in soft/loose soil complete all as specified and directed.
Excavation in trenches in any type of soil not exc 1.5m wide and not exc 1.5m in depth and getting out in any type of soil complete all as specified and directed.
M&L Cement Concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete, complete all as specified and directed.
RCC (Design mix) M-25 as in foundations, including raft footings foundation beams, Plinth Beams, base of col, etc. Basement slabs, under reamed piles and mass concrete complete all as specified and directed.
RCC (Design mix) M-25 as in columns, Pillars, piers, Posts and struts complete all as specified and directed.
RCC (Design mix) M-25 as in chajjas complete all as specified and directed.
RCC (Design mix) M-25 as in Beams, cantilevers bressummers, lintel over 1.5 m span complete all as specified and directed.
RCC (Design mix) M-25 as in slabs supported on walls beams and columns in floors, roofs, landings, balcony, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work vertical of to batter, rough finished flat surfaces of concrete complete all as specified and directed.
Use and waste formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished surfaces of concrete, square, rectangular or polygonal complete all as specified and directed.
S & F Form work to sides and soffits of floor or roof beams beam , lintels, cantilevers, shelves etc with rough finished complete all as specified and directed.
S & F Form work to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar works not exc 20 cm wide and sides of PCC/RCC bands exc 10 cm but n.exc 20 cm wide with rough finished complete all as specified and directed.
Use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm widefair finished surfaces of concrete complete all as specified and directed.
Use and waste formwork to chajjas, through the similaars items including edges complete all as specified and directed.
S&F APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. Not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed.
M & L for TMT bars (Fe 500), 10mm dia and over in reinforcement cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (anealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Ditto all as per Ser Item No. 16.00 above but 8 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders complete all as specified and directed.
M & L for PCC Block masonary with solid blocks, exc 10 cm in width and setting in mortar in CM 1:6 type C1 1:3:6 (20 mm graded aggregate) complete all as specified and directed.
M&L for brick work with sub class B bricks straight or curved on plan to any radiuos in half brick thick wall built in cement mortor 1:6 complete all as specified and directed.
Earth filling under floors,spreading,levelling in layers n.exc 25cm thick each including watering & well ramming complete all as specified and directed.
M & L for Hard core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick watered and well rammed to a true surface.
M&L for 75 mm thick cement concrete type C-2, 1:3:6 (40mm graded agg) as in Sub-base to floor finishes complete all as specified and directed.
M&L for 25 mm thick cement concrete type B-1, 1:2:4 (20mm graded agg) as in Sub-base to floor finishes complete all as specified and directed.
M&L for 20 mm thick screed bed or bedding layer of mortar in CM 1:4 for laying floor finishes such as kota flooring complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with pigment to match the shade of the slab including rubbing and polishing complete over 10mm thick plaster in Cement Mortar 1:3 complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on brick or PCC block masonry surface finished even and fair without using, extra cement including mixing of water proofing compound as per manufacture's instructions (water proofing compound shall be measured and paid separately), complete all as specified and directed.
Material and labour for 10 mm thick rendering in cement mortar (1:6) as in internal surface on fair face of brick or concrete surface finished even and fair complete all as specified and directed.
Material and labour for 5 mm thick rendering in cement mortar (1:3) as in ceiling on fair face of brick or concrete surface finished even and fair complete all as specified and directed.
Material and labour for 10 mm thick rendering in cement mortar (1:3) as in roof slab on green concrete surface finished even and fair complete all as specified and directed.
Supply only liquid water proofing compound @ 0.200 Ltr per 50 kg of cement cement or as per manufacturer's instructions complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:3:6, type C-2 (using 40mm graded agg) as in plinth protection finished even and smooth using extra cement.(incl necessary joint filling with mixture of paving bitumen & sand in 1:3) complete all as specified and directed.
S & F 1.25mm thick of laths as Steel rolling shutters, without ball bearing, as specified including rod, hasp and staples and one shop coat of primer, erected in position as indicated, complete: gear operated type with chain wheel and hand chain complete all as specified and directed.
S & F Ball bearing for rolling shutters complete all as specified and directed.
M & L for Steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazing bars dovetailed or welded complete all as specified and directed
Preparing newly plastered or concrete surfaces of wall and applying two coats of cement based paint over a coat of white wash.
M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparing newly plastered surfaces of wall and applying two coats OBD over 3 mm thick wall care putty complete all as specified and directed.
M&L for preparation of new or previously untreated steel or iron surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed.
M&L 12mm Perforated particle board/ tiles for insulation and accoustic purposes, 60x60 cm in size suspended false ceiling incl GI powder coated grid work using 32.5mmx23.5mmx1.5mm main tee, 25mmx23.5mmx1.28mm crossed Tee & 25mmx23.5mmx1.2mm angle fixed to wall for false ceiling incl necessary supporting hanger with 6mm dia GI wire & wire J bolts washer nuts for securing frame work to ceiling, suspended @ 125 cm C/C bothways, size of grid shall be 605x605mm complete all as manufacture instruction complete all as specified and directed.
M&L for Non skid white ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 20mm thick screed bed in Cement Mortar 1:6 complete all as specified and directed.
M&L for Glazed coloured ceramic tiles in vertical surfaces 300x200x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 15mm thick plaster in Cement Mortar 1:4 complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavating in post holes for hard / dense soil (or similar holes) each not exc 0.5 Cum in any type of soil, getting out, returning fillimg in and ramming earth or broken rubble mixed with earth around in layers not exc. 25 cm thick watering and well ramming and removing surplus soil to a distance n, exc 50m and making good surface complete all as specified and directed.
M & L for cement concrete 1:2:4 Type B-2 using 40mm graded crushed stone aggregates in foundation filling and mass concrete complete all as specified and directed.
M&L with fabrication for mild steel tubular poles or trusses purlin etc including special shaped washer etc. complete using ERW or induction butt welded tubes, confirming to IS-1161-1979 grade St-240 complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc of Fe 410 -W (GdeE- 250) quality-A complete all as specified and directed.
M&L for 40 mm thick cement concrete (M-15), type B1 (using 20mm graded stone aggregate) as in flooring finished even and smooth using extra cement complete all as specified and directed.
M&L for laying/spreading of sand as in 25 mm thick cushion to precast concrete interlocking paver block including watering & consolidating complete all as specified and directed.
M&L for 60mm thick Machine pressed precast concrete interlocking coloured rubber mould paver block any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade, jointed with grey cement and pigment including side coping of cement concrete 1:2:4 using 40 mm graded stone aggregate complete all as specified and directed.
Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor Flame retardant PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board ) ISI Marked (IS:14772) for housing switches / sockets complete all as specified and directed.
One light point controlled by one switch .
One Fan point controlled by one regulator/switch.
One 3 pin socket 5 A on independent board.
One 3 pin socket 5 A on the same switch board.
Material and labour for providing point wiring with two runs of 2.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 2.5 Sqmm single core copper stranded Flame retardant PVC insulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings / fixture etc and open recessed type Plastic Enclosure (Plastic Switch Board) ISI marked (IS 14782) for housing one 15 A Switch / sockets complete all as specified and directed.
S&F ceiling rose surface bakelite 65mm, three terminals (ISI marked) complete all as specified and directed.
Supply and fix switch piano flush type 5 Amp one way complete all as specified and directed.
Supply only socket outlet 2-in-1, 3 pin ,5 amps, flush type complete all as specified and directed.
Supply only socket outlet 2-in-1, 3 pin ,5 and 15 amps, flush type complete all as specified and directed.
S & F Lamp Holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed
M & L for sub main wiring with two runs of single core 4.0 Sq mm FLRSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4.0 Sq mm single core Flame retardant PVC insulated unsheathed multi stranded copper conductor green colour cable for continuous earthing complete in & including PVC casing caping with all fttiing & fixtures complete all as specified and directed. (Note:- Two runs of 4.0 Sqmm copper cable and one run of 4.0 sqmm copper cable including PVC casing caping shall be measured and paid as one length)
Supply and fixing MCB TPN DB 4 way IP 43-IK-09 with metal double door suitable for housing of MCBs complete all as specified and directed.
Supply and fixing MCB SPN DB 4 way IP 43-IK-09 with metal double door suitable for housing of MCBs complete all as specified and directed.
S&F MCB TPN 63 Amp 10 kA 240 Volt, 'C' Curve and electric connections with copper thimbles complete all as specified and directed.
S&F MCB DP 63 Amp 10 kA 240 Volt, 'C' Curve and electric connections with copper thimbles complete all as specified and directed.
M&L for MCB SP 6-32 Amps, 'C' Curve and electric connections with copper thimbles complete all as specified and directed.
Supply & fix LED tube light along with fixture, 1x20 W( 4 feet long) surface and wall mounted LED batten, extruded aluminium housing & integrated electronic drive including connecting up with three core 0.5 Sqmm flexible copper conductor cable ceiling rose to fitting terminal complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply & fix exhaust fan, heavy duty, metal body , AC single phase 230/ 240 V of size 300 mm sweep with louver shutter having copper bound winding including 3 core copper electric cable connection from ceiling rose to fitting terminal complete all as specified and directed.
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed.
Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified for following size:- 16 sqmm 4.0 core
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole/ GI tubing etc. complete all as specified and directed.
Soft/loose soil
Hard/dense soil
Soft/disintegrated rock
Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for any type of soil complete all as specified and directed.
Removing the surplus spoil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level complete all as specified and directed.
Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable complete all as specified and directed. [Note : Measuremenet will be done after punning]
Supplying and laying un-reinforced precast concrete cable cover, class I, flat, size 250mm x 150mm x 40mm for cable protection complete all as specified and directed.
S&F GI Pipe Light grade with all connected accessories of sizes 40 mm complete all as specified & directed.
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers etc connected to DBs all as shown in electrical plate No.5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation / earth work in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade,including GI wire 4 mm dia with GI protection pipe of 15 mm medium grade up to 7.5 meter length etc complete all as specified and as directed.
Taking down existing tube light fittings and disconnecting connection cable ends complete all as specified and directed.
S&F Vertical double door Distribution board TPN 4 way 200 A rated busbar suitable for incomming MCCB and Out going MCBs including MCCB 100A 4 Pole 18 KA - 1 Nos complete all as specified and directed.
Supply and fix sheet metal enclosure MCB DB double door SPN 8 way 230 V with neutral link and with 200 A bus bar complete all as specified and directed.
Supply and fix MCB SPN 40 Amp, 230 volt 'C' series complete all as specified and directed.
S & F Socket outlet 2 in 1, 3 pin, 5A flush complete all as specified and directed.
Supply and fix switch piano flush type 15 A one way complete all as specified and directed.
S & F Socket outlet 2 in 1, 3 pin, 5 and 15 A flush type complete all as specified and directed.
Supply and fix Energy efficient recess mounted LED panel fitting 36 Watt suitable for 2x2 grid in white colour with high quality diffuser for uniform light & high Efficiency. Made from CRCA sheet, Pre-coated white color. Separate replaceable electronic driver, lumen constant of 5700/6500K colour temperature with current electronic connector and making proper connections complete all as specified and directed.
Supply & fix wall mounted fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting complete all as specified and directed.
Supply & fix fans ceiling complete with electronic type regulator and accessories 230 V , 1400 mm sweep complete all as specified and directed.
M & L for sub main wiring with two runs of single core 6.0 Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4 Sq mm single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor including PVC casing & caping complete all as specified and directed. ( Note :Two runs of 6.0 Sqmm copper cable,one run of earth wire of 4 Sqmm copper cable and one run of casing and capping shall be measured & paid as one length.)
Supply, installation, testing and commisioning of automatic servo Voltage stabilizer for automatic operation, three phase 50 Hz naturally oil cooled indoor type & unbalanced type, copper wound, digital display type and designed for input variation between 340 V to 480 V with output voltage stabilized at 415 with accuracy ± 1% (adjustable) of capacity 500 kVA including initial filling of oil & testing & commisioning complete all as specified and directed. (a) BIS: 9815: Part 1:1994 (b) Input Voltage: 340-480 V (c) Output stabilizedd voltage : 415 + 1% (adjustable) (d) Nominal frequency : 50 Hz (e) Distortion : No distortion in wave form (f) Sensitivity : ± 1% (g) Rate of correction : 8 V per second for single phase and 20 Volt/second for phase to phase (h) Efficiency : >95% (j) Type of Load : Three phase unbalanced type (k) Digital Display : Voltmeter/Ammeter (l) Losses : No load : <0.5%, Full load : <2.5% (m) Protection : Over load, short circuit protection, High low cutoff, bypass arrangement, single phase protection and phase sequence reversal protection. (n) Form factor : DIN rail type (o) Response time : less than 10 millisecond
Supply laying, joint testing & commissioning in replacement of LT under ground cable 1100 volts grade XLPE (cross linked polythene) armoured with galvanised round steel wire or steel strep,electric power cable heavy duty, with multi stranded aluminum conductor, laid in trenches, ducts fixed on wall/poles with proper size saddles and clamp laid under road/path/drain/culverts or enclosed in GI pipe/fix complete all as specified, for following size : 400 Sq mm x 3.5 core
M&L for earthing complete with GI earth plate electrode 60cmx 60cmx 6.3 mm thick buried directly in ground vertically at a depth not less than 2.25m below normal ground level with top level of earth plate at depth not less than 1.5m below normal ground level surrounded form all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using GI strip 25mmx4mm by means of bolts, nuts, check nuts and washers of galvanized iron and protected by GI pipe light grade 50mm bore connected to main switch board or main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, 80mm thick pre-cast RCC 1:2:4, type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4 Kg/sqm in lieu of CI cover, PCC 1:3:6 type C2 pit/chamber including all necessary excavation; and earth work, disposal of surplus soil to a distance not exceeding 50m all as specified and as shown in Electrical Plate No 3 of MES Schedule Part-I complete all as specified and directed.
S&F earth continuity conductor fied to walls or burried in ground or drawn in pipe of size 25x4 mm galvanised iron strip complete all as specified and directed.
Pumping sets monoblock electric driven,three phase, supply and Install complete Head 20m -30m discharge 12Lps -30Lps inclusive of starter,PCC foundation cable from panel to pumpset and canopy for rain protection and suction pipe of 100mm diameter upto length of 10m complete all as specified and directed. Notes:- (i) contractor has to make proper arrangment over pumpset and starter for safety against rain. (ii) Rate for Suction pipe of 100mm diameter upto length of 10m is deemed to be included in quoted rate.
Supply & lay and jointing tubing medium grade galvanised iron pipes, ISI marked with all fittings such as bends, tees, elbows, nipple, unions, short pieces, sockets etc and laid in trenches all as specified of following sizes :-
25mm dia bore
40mm dia bore
50mm dia bore
S & F gun metal gate valves with iron wheel head screwed both end for iron pipe and fixed complete all as specified and directed.
25mm dia bore
50mm dia bore
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm nominal cross section in service connections complete all as specified and directed.
Smruti Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .