| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.3 Cr+₹8.7 L (7.10%)Admitted-Finance III 246 MANIYATTU BUILDING KURUPPAMPADY P O RAYAMANGALAM ERNAKULAM KERALA 683545 INDIA | ERNAKULAM | KERALA | 683545 | ₹1.3 Cr+₹8.7 L (7.10%) | L2 | Admitted-Finance |
| 3 | L3₹1.4 Cr+₹15.9 L (13.1%)Admitted-Finance 13TH FLOOR DN18 SALTEE TECH PARK SECTOR V SALT LAKE BIDHAN NAGAR KOLKATA 700091 | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹1.4 Cr+₹15.9 L (13.1%) | L3 | Admitted-Finance |
| 4 | L4₹1.5 Cr+₹27.3 L (22.4%)Admitted-Finance | ₹1.5 Cr+₹27.3 L (22.4%) | L4 | Admitted-Finance |
| 5 | L5₹1.6 Cr+₹34.8 L (28.6%)Admitted-Finance 2277 RAJA PARK RANI BAGH RANI BAGH NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | ₹1.6 Cr+₹34.8 L (28.6%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | candela engineering corporation L2 | Bajaj Electricals Limited L3 | ARITRON SERVICES PRIVATE LIMITED L4 | SABHARI ELECTRICALS L1 | ADVANCED SPORT TECHNOLOGIES LLP L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00SITC of following Size of Stadium Mast Pole with PU painting with motorized control for man rider unit. The Mast shouild be supplied with a control panel( SMLDB), Aviation Lights & required Foundation Bolt nuts . The quoted tate should inclusive of transportation and civil foundations as recommended by the manufacturer. The Stadium Mast should be erected with suitable machineries like Crane etc. The contractor has to do necessary cabling between control panel and light fittings using suitable 3 core flexible copper wires according to the no of circuits. The drawings to be submitted to the Engineer In Charge for approval before any fabrication works as per the specification enclosed. | ||||||||
| 1.01 | 25 Mtrs stadium mast - (Polygonal Stadium mast towers with fixed head frame along with man-rider unit for accessing the head frame platform) | 4 | Set | 13,07,990 ₹52,31,960 | 13,33,718.75 ₹53,34,875 | 19,23,884.63 ₹76,95,538.52 | 11,25,720 ₹45,02,880 Lowest | 13,46,415 ₹53,85,660 |
| 2.00Design Supply Installation Testing & Commissioning of high-quality modular 1000W (+/- 10%) LED Sports Flood Light Fixture with a nominal efficiency > 120 LPW. CCT of 5700K with SDCM of < 5 and CRI : 70. The housing should be of Epoxy powder coated pressure die-cast aluminium housing (ADC12) in grey finish with Heat Resistant toughened clear glass to withstand extreme environments, Pre wired with external Potted, IP 67 isolated electronic LED drivers with APFC (SMPS based constant current supply) with lower THD, Output Short / Open Circuit protection, Over Voltage protection, Surge Voltage protection upto 10kV with SPD & other reliability test as per IS 15885 Part-2/Sec 13. | ||||||||
| 2.01The floodlight shall be designed for operation in ambient temp -10°C to + 50°C with PF > 0.95. Lifetime of 50K @L70. Product should be suitable for Operating voltage range - 100 - 300 V ac, continuous operation (6-8 Hrs. per day). The ingress protection should be minimum IP66 with an IK rating of 08.Optical compartments/external IP67 driver shall be maintenable/replaceable without impacting the LED Units. | ||||||||
| 2.02 | While accessing the gear compartment / external driver, the optical compartment should not be opened. The luminaire driver should have a 6KV onboard surge protection and an external 10KV/5KA SPD duly bolted in the luminaire for extra safety. The luminaire should be of Class B Serviceability. The wattage of each LED should be greater than 1 watt and less than 5 watt. Only high power single white LED chip with ceramic based suitable for outdoor use is allowed. Multi chip, array multi die, mid power, integrated arrays and COB's are not permitted. High power LED used in the luminaire should be SMD type only of make Lumileds, Bridgelux, Osram, Nichia and CREE & no other make. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @325V and have an auto recovery feature. The drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire as per the enclosed specification. | 72 | Nos | 47,875 ₹34,47,000 | 52,872 ₹38,06,784 | 45,347.4 ₹32,65,012.8 Lowest | 48,380 ₹34,83,360 | 65,679 ₹47,28,888 |
| 3.00Supplying& Laying of following sizes PVC XLPE insulated alu/cu Conductor armored LTUG cable in a 50 mm to 100 mm dia HDPE DWC pipe in a trench of 50cm wide and 75cm depth including earth work excavation in all soils and sub soils and back filling, consolidated in a regular interval of 25cm thick rammed and complying with standard specification including cable route markers in every 50m span. | ||||||||
| 3.01 | 3.5c X 300 sq.mm ( Alu) | 400 | Metre | 1,870 ₹7,48,000 | 2,302 ₹9,20,800 | 1,821.92 ₹7,28,768 Lowest | 2,065 ₹8,26,000 | 2,824 ₹11,29,600 |
| 3.02 | 3.5c X 120 sqmm ( Alu) | 1,000 | Metre | 890 ₹8,90,000 Lowest | 1,241 ₹12,41,000 | 991.2 ₹9,91,200 | 1,032.5 ₹10,32,500 | 1,675 ₹16,75,000 |
| 4.00Supplying and making end termination for following sizes alu/cu Conductor LT UG cable using suitable compression gland with required copper ferulles / socket and other jointing materials | ||||||||
| 4.01 | 3.5c X 300 sq.mm ( Alu) | 20 | Nos | 1,678 ₹33,560 | 2,491 ₹49,820 | 1,858.5 ₹37,170 | 1,239 ₹24,780 Lowest | 5,008 ₹1,00,160 |
Tender Value
₹1.5 Cr
EMD Value
₹2.9 L
Closing Date
11 Dec 2024, 3:00 pmClosed
Executive Engineer (Electrical)
Engineering Unit, Admin Block 3rd Floor, IIT Madras CHENNAI-600036
Providing Flood lighting for outdoor / Indoor games in Stadium inside IIT Madras Premises
2024_IITM_214991_1
22/2024-25/ELDB
Open Tender
Electrical Works
Item Rate
120 days
IIT MADRAS CHENNAI
All required documents as specified in the tender
2 documents required · 2 mandatory
₹0
₹2.9 L
GOOGLE MEET
13 Jan 2025
18 Nov 2024
12 Dec 2024
18 Nov 2024
11 Dec 2024
27 Nov 2024
18 Nov 2024 - 26 Nov 2024
26 Nov 2024
Amount
SITC of following Size of Stadium Mast Pole with PU painting with motorized control for man rider unit. The Mast shouild be supplied with a control panel( SMLDB), Aviation Lights & required Foundation Bolt nuts . The quoted tate should inclusive of transportation and civil foundations as recommended by the manufacturer. The Stadium Mast should be erected with suitable machineries like Crane etc. The contractor has to do necessary cabling between control panel and light fittings using suitable 3 core flexible copper wires according to the no of circuits. The drawings to be submitted to the Engineer In Charge for approval before any fabrication works as per the specification enclosed.
25 Mtrs stadium mast - (Polygonal Stadium mast towers with fixed head frame along with man-rider unit for accessing the head frame platform)
Design Supply Installation Testing & Commissioning of high-quality modular 1000W (+/- 10%) LED Sports Flood Light Fixture with a nominal efficiency > 120 LPW. CCT of 5700K with SDCM of < 5 and CRI : 70. The housing should be of Epoxy powder coated pressure die-cast aluminium housing (ADC12) in grey finish with Heat Resistant toughened clear glass to withstand extreme environments, Pre wired with external Potted, IP 67 isolated electronic LED drivers with APFC (SMPS based constant current supply) with lower THD, Output Short / Open Circuit protection, Over Voltage protection, Surge Voltage protection upto 10kV with SPD & other reliability test as per IS 15885 Part-2/Sec 13.
The floodlight shall be designed for operation in ambient temp -10°C to + 50°C with PF > 0.95. Lifetime of 50K @L70. Product should be suitable for Operating voltage range - 100 - 300 V ac, continuous operation (6-8 Hrs. per day). The ingress protection should be minimum IP66 with an IK rating of 08.Optical compartments/external IP67 driver shall be maintenable/replaceable without impacting the LED Units.
While accessing the gear compartment / external driver, the optical compartment should not be opened. The luminaire driver should have a 6KV onboard surge protection and an external 10KV/5KA SPD duly bolted in the luminaire for extra safety. The luminaire should be of Class B Serviceability. The wattage of each LED should be greater than 1 watt and less than 5 watt. Only high power single white LED chip with ceramic based suitable for outdoor use is allowed. Multi chip, array multi die, mid power, integrated arrays and COB's are not permitted. High power LED used in the luminaire should be SMD type only of make Lumileds, Bridgelux, Osram, Nichia and CREE & no other make. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @325V and have an auto recovery feature. The drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire as per the enclosed specification.
Supplying& Laying of following sizes PVC XLPE insulated alu/cu Conductor armored LTUG cable in a 50 mm to 100 mm dia HDPE DWC pipe in a trench of 50cm wide and 75cm depth including earth work excavation in all soils and sub soils and back filling, consolidated in a regular interval of 25cm thick rammed and complying with standard specification including cable route markers in every 50m span.
3.5c X 300 sq.mm ( Alu)
3.5c X 120 sqmm ( Alu)
Supplying and making end termination for following sizes alu/cu Conductor LT UG cable using suitable compression gland with required copper ferulles / socket and other jointing materials
3.5c X 300 sq.mm ( Alu)
3.5c X 120 sqmm ( Alu)
Kiosk MV Panel
Supply , Erection,Testing and commissioning of suitable size extendable floor mounting cubical type following Kiosk LT Main Panel board suitable for 415V 3ph 4 wire 50Hz AC supply system fabricated in a compartmentalized design from CRCA sheet steel of 2mm thick for frame works and cover with 3mm thick removable gland plate ,cleaning and finishing with 7 tank process for powder coating with siemens grey having extensible type copper busbar of suitable capacity as per the incomer ACB /MCCB/SDF ratings with DMC/SMC busbar suppotrs with short circuit withstand capacity of 31MVA / 1Second , bottom base channel of 100mmX 50mm X 5mm. .The In/Out going Cable entry should be from the rear side of the panel.
2 separate run of 25 x 5 mm copper earth bus painted in green colour should be provided all along the panel and connected to the main grid. Interconnectios should be taken to metering chamber, MCCB's, ACB's, FSU's etc sothat all current carrying components are effectively earthed.
PANEL-1 ( In Stadium)
Incomer
400A TPN MCCB 36kA with micro processor based trip units ,front operated rotary handle and with ON/OFF/TRIP indications- 2 Nos
Outgoings
250A TPN MCCB 36kA with micro processor based trip units ,front operated rotary handle and with ON/OFF/TRIP indications- 8 Nos
630A Copper Busbars
Three phase indication lamps with toggle switch-1set, microprocessor based digital multi function meter with communication port and the facility for active and reactive power measurements -1set with required CTs and control fuses etc should be provided for each incomers. Necessary Spreaders / extended copper bus bars of suitable rating with required holes should be provided for the cable and bus bar terminations.The handle should be pad lockable type in both ON/OFF positions.The work should be inclusive of providing mechanical interlocking arrangement between incomers ..Necessary drawing approval ( With QAP and GTP) should be obtaied from the Engineer incharge before fabrication.
Panel- 2 ( At Sarayu SS)
630A TP ACB 50 kA- 1 No (MDO independent manual spring closing mechanism-1no, microprocessor release for o/c , e/f and short circuit protection-1no, breaker ON/OFF/Trip indication Lamps) with CTs and multifunction meter. The size of the ACB is match with the existing panel and to be coupled with the existing MV Panel with supplying fixing of suitable rating of copper busbars
Supply, Erection, Testing and Commissioning of copper plate earth by excavation of soil and sub soil , back filling with equal layers of salt and charcoal and the excavated soil , ramming, consolidating, Masonry construction, heavy duty cover slab etc. The GI pipe should be 25mm dia and 3mt long bolted with 600 x 600 x 3 mm thick copper plate at the bottom. 2R of 25 x 3 mm copper flats should be taken from the copper plate to the top of theGI pipe and clamping with suitable clamps
Earthing the installation with the following sizes of earth wires. The rate shall be inclusive of spacer clamp for main earth flat suitable clamping with the MS flats for earth wires including crimping of socket etc.or laying below 0.5m from ground level including earth work excavation and refilling the excavated soil.
25 x 6mm GI flat
Annual Maintenance Contract for 5 consecutive year after warrantee
Cost of comprehensive maintenance of installation other than LED fittings that includes routine, preventive & breakdown maintenance for period of five years including repair/replacement of worn out items with minimum downtime and warranttee & guarantee of repaired/replaced items after completion. (The amount quoted for this item will not be taken into account for deciding the lowest tender, but will be executed as a separate supplementary contract after the completion of the warantee period.
1st year (Rate Only)
2nd year (Rate Only)
3rd year (Rate Only)
4th year (Rate Only)
5th year (Rate Only)
candela engineering corporation (BID ID -784343)
Bajaj Electricals Limited (BID ID -784973)
ARITRON SERVICES PRIVATE LIMITED (BID ID -778174)
ADVANCED SPORT TECHNOLOGIES LLP (BID ID -784663)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.27 MB
TenderNoT22.pdf
Tender Documents • 1.78 MB
PriceBidForViewT22.pdf
Other Document • 0.65 MB
BOQ_237450.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .