| 1 | L1₹3.8 LAccepted-AOC VILL NAYA GUGNAN PO SUJANPUR TEH DISTT PATHANKOT 145023 | PATHANKOT | PATHANKOT | PUNJAB | 145023 | ₹3.8 L Quoted ₹4.2 L | L1 | Accepted-AOC lowest |
| 2 | L2₹4.9 L+₹66,501.50 (15.7%)Rejected-AOC GOVT CONTRACTOR VILL NAYA SUJAN FEROZPUR KALAN TEH DIST PATHANKOT PIN 145023 | PATHANKOT | PATHANKOT | PUNJAB | 145023 | ₹4.9 L+₹66,501.50 (15.7%) | L2 | Rejected-AOC not found lowest |
| 3 | L3₹5.3 L+₹1.1 L (25.2%)Rejected-AOC | ₹5.3 L+₹1.1 L (25.2%) | L3 | Rejected-AOC not found lowest |
| 4 | L4₹5.3 L+₹1.1 L (26.4%)Rejected-AOC | ₹5.3 L+₹1.1 L (26.4%) | L4 | Rejected-AOC not found lowest |
| 5 | L5₹5.8 L+₹1.6 L (38.0%)Rejected-AOC | ₹5.8 L+₹1.6 L (38.0%) | L5 | Rejected-AOC not found lowest |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
9 Oct 2021, 6:00 pmClosed
GE BASOLI
GE BASOLI
REPAIR AND MAINTENANCE OF LT OH LINE, LT UG CABLE /AB CABLE, FEEDER PILLAR AND ACB AT MADHOPUR STATION UNDER GE BASOLI
2021_MES_474365_1
GE/BAS-32/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE BASOLI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE BASOLI
₹16,000
Yes
5 Jan 2023
10 Sept 2021
11 Oct 2021
10 Sept 2021
9 Oct 2021
25 Sept 2021
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5mtr in depth for foundation of pole and laying of UG cable and getting out in any type of soil complete all as specified and directed.
Excavation in trenches n. exc 1.5 mtr wide and but exc 1.5mtr in depth for foundation of pole and getting out in any type of soil complete all as specified and directed.
Returning filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25cm completed all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5M above the starting point complete all as specified and directed.
M/L Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified and directed.
Supply & filling sand cushioning to under ground cable 8 cm before laying the electric cable and 15 cm after laying the cable complete all as specified and directed. considering as per SSR 1991 of part -I
M&L for PCC ( 1:2:4) type B1 using 20mm graded stone aggregate for coping pedestal of poles. Including necessary form work fair finished to exposed surface complete all as specified and directed..
M&L for PCC ( 1 : 3 : 6 ) type C2 using 40mm graded stone aggreghate for foundation of poles and stay assembly
M&L for supply and fixing in replacement of old unsv Steel tubular swaged poles complete with cast iron plate, bolt, nuts & screws as specified type 410 SP-31 (09 mtr long) with 250mmx250mmx6mm mild steel plate continuously welded to Pole, bolts, nuts and screws and making holes as per requirement all as specified including factory painted with two coats black bituminous paint internally throughout and externally for embedded portion and applying one coat of red oxide primer, making 05 Nos strips each 30cm high with super enamel paint (Black and Yellow/white) from ground level/coping, upto 1.5M painting with two coats of aluminium paint for the remaining height complete all as specified and directed. Note:- Excavation, earth work and PCC in coping/foundation shall be measured and paid for separately.
Supply and fixing in replacement aluminium conductor steel re-inforced (ACSR) Ferret/of size 6/1x3.00 mm /of size 6/1x2.59 mm (weasal) and 6/1x2.11 mm of . for LT lines on concrete poles, stretching without kinks and bends, binding with (rates inclusive) binding wire complete all as specified and directed. Make : Alind/Industrial cable(India) ltd/NICCO/Bharat conductor
Restretching of existing loose OH,LT ACSR conductor wire including GI wire along the span of poles for sagging within the permissible limit,(five/four/two wireline), including binding/rebinding/joining with Aluminium winding wire in case of breakge of condouctor, size of winding wire shall not be less than 2 sqmm complete all as specified and directed . Note : (i) Nothing extra is admissible on account of jointing material and labour in case the conductor breaks during the stretching.
Trimming /cutting tree branches with clearing space upto 2 meter from the over head conductor system all around for LT distribution system , and as directed.Note : contractor shall take electric shutdown befor start work from main station and start line after triming of tree and informed to the JE/Engineer-In-Charge
S&F in structural steel work conforming to grade Fe-410S as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including , nuts, bolts, washers, welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat , one finishing coat of aluminium paint and epoxy coating, including taking down old corroded structural steel all as directed.
S & F in shackle type,vitreous Insulator incl one galvanised mild steel spindle, two galvanised iron washerrs,and one galvanised iron nut, 100 mm height, 115 mm dia ,suitable for 1100 Volt,complete all as specified and directed..Make-Jaipuria/RASHTRIYA/ PACTAL
S/F stay assembly complete comprising of 20mm dia 40cm long stay bow rod 20mm dia x 1.8 Mtr long galvanised stay rod threaded with nuts, including 300mmx300mmx6mm thick plate necessary clamps etc as shown on plate No. 1 on page 495 of SSR Part-I, 2009 complete including taking down U/S stay assembly . ( Note : Loop type insulator, stay clamp, stay wire, excavation and concrete work measured separately).
S/F galvanised steel stranded stay wire size 7/4mm for stay assembly complete all as specified and directed.
S/F loop type insulator iwith complete fiting porcelain, vitreous white or brown large size with over all dismensions 90x140mm , clearance of hole 25.5mm
M&L earthing complete with galvanised steel earth plate eletrode 600mmx600mm and 6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edges, of the plate not less than 1.5m below normal ground level, connected to the Galvanise Iron earth lead 32mmx6mm (GI Strip) size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6 mm earth lead protected by provision of GI medium grade pipe 40 mm bore including provision of aggregates with 40 mm thick cover of RCC (1:2:4) , reinforced with XPM (weight not less than 4 kg per sqmm) and frame of angle iron 40mmx40mmx3mm and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe of suitable length for watering perforated at bottom placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exceeding 50 mtr and removal of surplas soil to plate No 3 of SSR 2009 Part-I and connecting to feeder pillers and Transformer all as specified including testing on completion complete all as specified and directed.
Earthing complete with G.l earth plate electrode 60 cm x 60 cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connecting to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth lead protected by provision of GI medium grade pipe 15mm bore including 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, with fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and directed..
M&L for painting of MS cross arms as existing site made out of angle iron /MS channe and clamp in position fixied to PCC/steel pole 9 meter long with 2 coat of aluminium paint over a coat of red oxide as primer after scraping existing painted surface complete all as specified and directed..
M & L for Painting with two coats of synthetic enemal paint upto 1.5 meter above the ground level with black and yellow colour alternatively 30 cm intervel from bottom of pole of 9 meter RCC/tubular Poles
M & L for Painting of steel pole 9 meter long in position with 2 coat of aluminium paint over a coat of redoxide primer after scraping the existing painted surface complete all as specified and directed.
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE 150 sqmm 3.5 core, PVC insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade,cross section area are as under of Make- polycab/KEI/RPG including disconnecting and taking out old unsv LT cable.Note : (I) Earth work/ sand cushioning shall be measured and paid separately .
All as per item above but120 Sq mm X 3.5 core complete all as specified and directed.
All as per item above but70 Sq mm X 3.5 core complete all as specified and directed.
All as per item above but16 Sq mm X 4 core complete all as specified and directed.
All as per item above but25 Sq mm X 3.5 core complete all as specified and directed.
All as per item above but16 Sq mm X 2 core complete all as specified and directed.
Taking out the old unsv cable for repair in trenches or passing through pipe/fixed to pole/ wall XLPE insualted300/240/ 185 Sqmm X 3.5 core armourned heavy duty electric cable and depositing in the MES store yard complete all as specified and directed.
All as per item above but120/150 Sqmm X 3.5 core complete all as specified and directed.
All as per item above but 70/50/35 Sqmm X 3.5 core complete all as specified and directed.
All as per item above but 25/16/10 Sqmm X 3.5/4/2 core core complete all as specified and directed.
S & F in repairs cable end joint kit for 1100 volt, out door type joint complete with all jointing material and accessories suitable for 3.5 core cable of size 50 sqmm to 185 sq mm complete all as specified and directed.
S&F DWC high density polyethelene pipes in replacement having 63/50outer dia mm, inner as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fittings as required at site including aking down the old unserviceable complete all as specified and directed. Make -Trupati /Equivalent
S&F DWC high density polyethelene pipes in replacement having outer dia 90/76 mm, inner as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fittings as required at site including aking down the old unserviceable complete all as specified and directed.
S&F DWC high density polyethelene pipes in replacement having outer dia 120/103 mm, inner as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fittings as required at site including aking down the old unserviceable complete all as specified and directed.
Repair/ replacement to the unsv rusted feeder pillar box (KIOSK) with and including fabrication of indoor type incorporated with busbar chamber having aluminium busbar capacity 250 Amps insulated with RYB& black PVC insulation tape suitable for 415 volts 3 phase 4 wire system 50 c/s fixed on SMC/DMC in step way complete with dust and vermin proof provisions made of CRCA MS sheet not less than 3.00 mm thick also having provision for incoming and outgoing MCCB,s/ cables, 02 Nos earth terminal point complete with 10mm bolt, 02 nos nut and 02 Nos Washers 3mm thick complete. The panel body must be painted with powder coated paint after the complete 7 tanks dip process of to remove all impurties from the panel sheet, all the door must be fixed with detachable pin type hinges,steel door locking system, all the electrical connection inside the panel from bus bar to MCCB's shall be through aluminium strip properly insulated fixed on SMC/DMC insulators. Panel body shall be fixed on iron angle frame of size 50x50x5mm 40 cm grouted in 1:2:4 type 1 PCC 20 mm graded and 45 cm above the ground level duly painted with two coat of synthetic enammelled black paint over a coat of red oxide primer all as specified and directede . Note :- MCCB,s shall be fixed in independent cabin in horizontal position,Main bus bar in step way, the depth of the panel shall not be less than 350mm ,All the rates deemed to be included in the cost of the job. No extra cost shall be paid .Before placing the order Drg,s shall be approved by the GE and shall be kept in record.
(a) MCCB 150 Amps, 4 Pole, 415 Volts 36 KA Ics=100% Icu including all arrarngments.(Incoming)
(b) MCCB 63 Amps TP 25 KA 415 Volts 25 KA Ics=100% Icu -04 Nos (Outgoing)
(c) MCB SPN 40 Amps -01 No
(d) RYB LED Indicator lamp- 03 Nos
Make of MCCB,s - C&S/ABB/L&T/Legrand) Panel fabricators Make -DV Electromatic Pvt ltd/ Unitech//Power System and Controls/Standard Switch Gear/ Hertek Note :- MCCB,s shall be fixed in independent cabin in horizontal position,Main bus bar in step way, the depth of the panel shall not be less than 350mm ,All the rates deemed to be included in the cost of the job. No extra cost shall be paid. Before placing the order Drg's shall be approved by the GE and shall be kept in record.
Repair/ replacement to the unsv rusted bus bar panel including fabrication of front opening and outdoor type incorporated with busbar chamber ground mounted having aluminium busbar capacity 100 amps insulated with RYB& black PVC insulattion suitable for 415 volts 3 phase 4 wire system 50 c/s fixed on SMC/DMC in step way complete with dust and vermin proof provisions made of CRCA MS sheet not less than 3.00 mm thick also having provision for incoming/outgoing MCCB,s/ cables, 02 Nos earth terminal point complete with 10mm bolt, 02 nos nut and 02 Nos Washers3mm thick complete earth . The panel body must be painted with powder coated paint after the complete 7 tanks dip process of to remove all impurties from the panel sheet, all the door must be fixed with detach able pin type hinges,steel door locking system, all the electrical connection inside the panel from bus bar to MCCB,s shall be through aluminium strip properly insulated fixed on SMC/DMC insulators. having arrangement for fixing the same on ground with MCCB 63 Amp 25 KA rating 4 Pole 415 volts - 01 No (Incoming) all as specified and directede by Engr - in- charge. Panel body shall be fixed on iron angle frame of size 50x50x5mm 30 cm grouted in 1:2:4 type 1 PCC 20 mm graded and 30 cm above the ground level duly painted with two coat of synthetic enammelled black paint over a coat of red oxide primer complete all as specified and directed.
Dismantling and Taking down old U/S PCC LT pole of any size including earth work , removing the PCC etc complete all as specified & directed
Dismantling and taking down old existing ACSR conductor any type from existing HT/LT pole complete all as specified and directed.
Dismantling of steel work (brackets, clamps, channels including disc and pin insulators,nut & bolts) from existing HT pole complete all as specified and directed.
Dismantling insulators any type, any size and depositng to the same to the MES store yard complete all as specified and directed.
Dismantling of earth wire/ stay wire complete all as specified and directed.
M&L for galvanised steel wire 4 mm dia complete all as specified and directed.
M&L for supply and fixing in replacement of old unsv power factor inproving capacitor of capacity 15 KVAR suitable for fixing inside the existing LT feeder Pillar box complete including all fixing arrangements complete all as specified and directed.
BALKRISHAN GUPTA AND SONS
KALSI CONSTRUCTION CO
SHUSHANT ASSOCIATES
Ashoka Engineers
AGGARWAL ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .