Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAccepted-AOC AT FCI LAXMI BAZAR TALCHER PO VIKRAMPUR DIST ANGUL ODISHA 759117 | TALCHER | ANGUL | ODISHA | 759117 | L1 | Accepted-AOC Technocommercially eligible L1 bidder. | |
| 2 | Rejected-Technical | - | Rejected-Technical REJECTED FOR NOT BEING L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical REJECTED FOR NOT BEING L1 | |
| 4 | Rejected-Technical AT SAMET ELECTRO TOWER TAMRIT MARKET COMPLEX ROOM NO 15 HATATOTA TALCHER DIST ANGUL ODISHA PIN 759100 | TALCHER | ANGUL | ODISHA | 759100 | - | Rejected-Technical REJECTED FOR NOT BEING L1 |
Tender Value
₹9.3 L
EMD Value
₹11,700
Closing Date
17 May 2024, 5:00 pmClosed
Staff Officer(EnM), Jagannath Area, MCL
Jay Prakash, Staff Officer(EnM), Jagannath Area, MCL PH 06760-269717, 06670-269751(Extn)2023 Fax 06760-269527 E-mail so-enm-jaga.mcl(at)coalindia.in
Concealed wiring and lighting arrangement at newly constructed conference hall building , rooms of OCMS INTUC Central Union Office, ABKMS BMS Central Union Office and HMS Union Office at Balanda Colony of Jagannath Colliery,JA.
2024_MCL_307469_1
GM(JA)/EnM/e-Tender/24-25/ E-646/11 DTD. 03/05/24
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
JAGANNATH OCP, JA
AS PER NIT
4 documents required · 4 mandatory
₹11,700
25 Jun 2024
3 May 2024
20 May 2024
4 May 2024
17 May 2024
4 May 2024
4 May 2024 - 9 May 2024
Amount
Providing & fixing of 100 Amp TPN capacity disconnector fuse switch unit inside the existing panel board with ISI mark HRC fuses including drilling holes cubical panel, making , connections etc, as required
Supplying & fixing of Angle holder including connections etc. as required
Supplying & fixing of three pin 5Amp ceiling rose on the existing junction box wooden block including Connection etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing & fixing 6 pin 5/6 Amps & 15/16 Amps modular socket out let and 15/16 Amps modular switch connections etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing & fixing 3 pin 5/6 Amps modular socket out let and 5/6 Amps modular switch connections etc. as required .
Providing & fixing of 20Amps,240V,SPN Industrial type socket out let with 2 pole and earth metal enclosed plug top along with 20 Amp “C“ curve, SP MCB in sheet enclosure with on surface with chained metal cover for socket outlet and complete with connection , testing and commissioning etc. as required.
Wiring for light point, fan point/exhaust fan point/Call bell point with 1.5 Sq.m FRLS PVC insulated Copper conductor single core cable in surface/recessed Medium class PVC conduit with modular Switch, modular plate , suitable G.I.box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required . Group A
Wiring for light point, fan point/exhaust fan point/Call bell point with 1.5 Sq.m FRLS PVC insulated Copper conductor single core cable in surface/recessed Medium class PVC conduit with modular Switch, modular plate , suitable G.I.box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group B
Wiring for Circuit/ Sub-main wiring along with Earth wire with the following sizes of FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit as required. 2 x 2.5 Sq.mm + 1 x 2.5 Sq.mm earth wire
Wiring for Circuit/ Sub-main wiring along with Earth wire with the following sizes of FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit as required. 2 x 4 Sq.mm + 1 x 4 Sq.mm earth wire
Supplying & fixing of following way, horizontal type three pole and neutral sheet steel, MCB distribution board 415Volts, on surface /recess complete with tinned copper busbar, neutral bar ,earth bar , din bar interconnections, powder painted including earthing etc. as required ( but without MCB/RCCB /Isolator ) 8 way, ( 4+24 )Double door.
Supplying & fixing 5 Amp to 32 Amps rating 240/415Volts 10 KA ‘C’ curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing & commissioning etc. as required. (Single Pole)
Supplying & fixing 5 Amp to 32 Amps rating 240/415Volts 10 KA ‘C’ curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing & commissioning etc. as required. (Double Pole)
Supplying & fixing following rating , four pole , 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.( 100 amps )
Supplying and fixing following size/ modules G.I. box along modular base & cover plate for modular switches in recess etc. as required. 12 Module ( 200 mm x 150 mm )
Supplying and fixing following size/ modules G.I. box along modular base & cover plate for modular switches in recess etc. as required. 8 Module ( 125 mm x 125 mm )
Supplying and fixing following size/ modules G.I. box along modular base & cover plate for modular switches in recess etc. as required. 6 Module ( 200 mm x 75mm )
Earthing with G.I. earth plate 600mm x 600mm x 6mm thick including accessories & providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr long etc. With charcoal/ coke and salt as required.
Supplying and Laying 6 SWG G.I. wire at 0.5 meter below ground level for conductor earth electrode including connection / termination with G.I. thimble etc. as required.
Supplying & fixing modular switch /socket on the existing modular plate & switch box including connections but excluding modular plate etc as required . (5/6 Amp Switch)
Supplying & fixing modular switch /socket on the existing modular plate & switch box including connections but excluding modular plate etc as required .3 pin 5/6 amp socket out let
Supplying and fixing of 20mm sizes of medium class PVC conduit along with accessories in surface including cutting the wall and making good the same in case of recessed conduit as required
Providing & fixing of LED panel ceiling light fittings (18 watt )
Supplying & fixing of 250mm, metallic ventilating fan, 1200mm rating , energy saving complete set as required .
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
TARENI ELECTRICALS
DURGA ELECTRICALSAND ELECTRONICS
M/S SHREE GANESH POWERTECH
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .