Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.0 LAccepted-AOC DANGRA TOLI CHOWK PURULIA ROAD RANCHI | RANCHI | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹49.0 L+₹73,880 (1.53%)Rejected-Finance H B ROAD NEAR LAHPUR THANA RANCHI | RANCHI | RANCHI | JHARKHAND | 834002 | L2 | Rejected-Finance REJECTED | |
| 3 | L3₹49.3 L+₹1.1 L (2.23%)Rejected-Finance | L3 | Rejected-Finance REJECTED |
| Sl No | Description | Qty | Unit | Blaca Corporations L1 | CHANDRA BROTHERS L3 | RANCHI ELECTRICALS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supplying and installation of horizontal split casing centrifugal pump having discharge of 90000 G.P.H clear water against a total head of 45 meters (137.76 feet) Make- Kirloskar/Mather and Platt/ jyoti / WPIL with Bronze / S.S impeller coupled with suitable squirrel cage induction motor 3 ph, 415 V ± 10% , 1400 to 1500 r.p.m, Make- Kirloskar/ jyoti/ Crompton /ABB coupled by means of tyre coupling on a common base plate with N.R valve, sluice valve rating PN- 1, ISI marked , foot valve, pressure gauge etc. all complete. | 2 | SET | 17,25,000 ₹34,50,000 Lowest | 17,70,000 ₹35,40,000 | 17,50,000 ₹35,00,000 |
| 2.00 | Cost towards supply and fitting 125 H.P fully automatic air break star delta starter , Make- L&T /Havell’s/ Siemens / Schneider/ BCH | 2 | Each | 2,40,000 ₹4,80,000 Lowest | 2,45,000 ₹4,90,000 | 2,50,000 ₹5,00,000 |
| 3.00 | Cost towards replacement of damaged parts of panel by new supply and fitting 400 amp T.P.N DTH MCCB-1no incoming feeder and 320 amp T.P.N DTH MCCB-2 nos. outgoing ,0 to500v voltmeter -2. nos., 0to 200 amp ammeter-2 nos. with selector switch ,indicating lamp 3 Nos., making internal connection with copper wire etc. | 1 | JOB | 1,97,000 ₹1,97,000 | 1,95,000 ₹1,95,000 | 1,90,000 ₹1,90,000 Lowest |
| 4.00 | Cost towards dismantling 2 nos. 50 H.P C/F pump set with all accessories such as suction and delivery pipe line ,foot valve ,sluice & N.R valve, base plate etc ,including demolish old foundation -1 nos. for installation of new pump set, including keeping pump set in store or as per direction of E/I and throwing broken foundation outside the pump house including cost of labors , tools, tackles | 2 | JOB | 14,500 ₹29,000 | 14,000 ₹28,000 Lowest | 15,000 ₹30,000 |
| 5.00 | Cost towards making new R.C.C/ P.C.C foundation with supplying stone chips, sand, cement, in the ratio 3:2:1 respectively about 5’x4’x3’for above pump sets including foundation bolts with nut and washer and curing plastering of foundation ,all complete . | 2 | JOB | 21,500 ₹43,000 Lowest | 22,000 ₹44,000 | 22,000 ₹44,000 |
| 6.00 | Supplying and laying of 185 mm sq. 1.1 K.V grade,3.5 core P.V.C insulated and sheathed armored Al. cable in air /wall/ underground as where as required with lugs, make – polycab / havell’s /,KEI, ISI marked | 50 | METRE | 1,710 ₹85,500 Lowest | 1,750 ₹87,500 | 1,730 ₹86,500 |
| 7.00 | Cost of supply & laying, commissioning of 3 core 70 mm² copper conductor cable 1.1 KV grade PVC insulated and PVC sheathed unarmored from panel to starter and starter to motor with lugs socketing | 120 | METRE | 2,860 ₹3,43,200 Lowest | 2,900 ₹3,48,000 | 2,900 ₹3,48,000 |
| 8.00 | Cost towards making chemical earthing as per I:E Rules ,etc. all complete | 2 | JOB | 16,500 ₹33,000 Lowest | 17,000 ₹34,000 | 17,000 ₹34,000 |
| 9.00 | Cost towards making suction & delivery pipe line with supply of 250 m.m dia. heavy duty M.S pipe 60 feet , 250 m.m dia. M.S flange- 8 nos. , 250 m.m dia. heavy duty M.S bend -4 nos. 150 m.m dia. heavy duty M.S pipe -12 ft., 150 m.m. dia. heavy duty M.S flange -4 nos. 150 m.m dia. heavy duty M.S bend -4 nos. , making PCC supporting pillar for suction and delivery pipe line, including cutting welding , required nut bolts, washer, rubber insertion, etc., testing on load , all complete . | 1 | JOB | 99,000 ₹99,000 | 1,00,000 ₹1,00,000 | 95,000 ₹95,000 Lowest |
| 10.00 | Cost towards making earthing connection from earth pit to change over , stabilizer ,panel, starter, motor with 6 SWG G.I wire | 40 | METRE | 50 ₹2,000 Lowest | 50 ₹2,000 Lowest | 52 ₹2,080 |
Tender Value
₹48.3 L
EMD Value
₹97,000
Closing Date
2 Feb 2026, 2:00 pmClosed
EXECUTIVE ENGINEER
D W AND S MECHANICAL DIVISION HAZARIBAG
Supplying Installation Commissioning AND Testing of H.S.C Centrifugal pump set and associated works at W.T.P. water supply pumping plant Reorganization Urawan for urban water supply Jhumaritilaiya
2026_DWSD_109574_1
DWSD/HZB/MECH/TILAIYA/SUPPLY-5
Open Tender
Pumps/Motors
Supply
120 days
JHUMRI TELAIYA
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
₹97,000
Yes
7 Apr 2026
26 Jan 2026
3 Feb 2026
26 Jan 2026
2 Feb 2026
26 Jan 2026
Supplying and installation of horizontal split casing centrifugal pump having discharge of 90000 G.P.H clear water against a total head of 45 meters (137.76 feet) Make- Kirloskar/Mather and Platt/ jyoti / WPIL with Bronze / S.S impeller coupled with suitable squirrel cage induction motor 3 ph, 415 V ± 10% , 1400 to 1500 r.p.m, Make- Kirloskar/ jyoti/ Crompton /ABB coupled by means of tyre coupling on a common base plate with N.R valve, sluice valve rating PN- 1, ISI marked , foot valve, pressure gauge etc. all complete.
Cost towards supply and fitting 125 H.P fully automatic air break star delta starter , Make- L&T /Havell’s/ Siemens / Schneider/ BCH
Cost towards dismantling 2 nos. 50 H.P C/F pump set with all accessories such as suction and delivery pipe line ,foot valve ,sluice & N.R valve, base plate etc ,including demolish old foundation -1 nos. for installation of new pump set, including keeping pump set in store or as per direction of E/I and throwing broken foundation outside the pump house including cost of labors , tools, tackles
Cost towards making new R.C.C/ P.C.C foundation with supplying stone chips, sand, cement, in the ratio 3:2:1 respectively about 5’x4’x3’for above pump sets including foundation bolts with nut and washer and curing plastering of foundation ,all complete .
Supplying and laying of 185 mm sq. 1.1 K.V grade,3.5 core P.V.C insulated and sheathed armored Al. cable in air /wall/ underground as where as required with lugs, make – polycab / havell’s /,KEI, ISI marked
Cost of supply & laying, commissioning of 3 core 70 mm² copper conductor cable 1.1 KV grade PVC insulated and PVC sheathed unarmored from panel to starter and starter to motor with lugs socketing
Cost towards making chemical earthing as per I:E Rules ,etc. all complete
Cost towards making suction & delivery pipe line with supply of 250 m.m dia. heavy duty M.S pipe 60 feet , 250 m.m dia. M.S flange- 8 nos. , 250 m.m dia. heavy duty M.S bend -4 nos. 150 m.m dia. heavy duty M.S pipe -12 ft., 150 m.m. dia. heavy duty M.S flange -4 nos. 150 m.m dia. heavy duty M.S bend -4 nos. , making PCC supporting pillar for suction and delivery pipe line, including cutting welding , required nut bolts, washer, rubber insertion, etc., testing on load , all complete .
Cost towards making earthing connection from earth pit to change over , stabilizer ,panel, starter, motor with 6 SWG G.I wire
Supply and fitting 500 amp TPN switch fuse unit-1 no including required materials such as clamp, nut, bolts, etc, for the job , make – L&T, Havell’s, any Reputed make ISI Marked.
Supply, fitting & commissioning of lighting arrangement at pump hose and outside of pump house such as tube light 40 W complete set 4 no and 70 W LED lamp complete set 6 nos. and making wiring, light point, fan point etc. as required.
stage.html
html • 0.05 MB
technical_148013.pdf
techsummary_148013.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
BOQ_148013.xls
BOQ • 0.24 MB
T.pdf
Tender Documents • 0.77 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .