Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹6.8 LAccepted-AOC AT ITI CHHAK IN FRONT OF SAI MANDIR TALCHER DIST ANGUL ODISHA P O 759100 | TALCHER | ANGUL | ODISHA | 759100 | L-1 | Accepted-AOC ACCEPTED AND AWARDED BY COMPETENT AUTHORITY | |
| 2 | L-2₹7.4 L+₹61,976.79 (9.09%)Rejected-Finance AT PO REMUAN TALCHER DIST ANGUL ODISHA 759100 | TALCHER | ANGUL | ODISHA | 759100 | L-2 | Rejected-Finance SINCE THE BIDDER IS NOT L-1 | |
| 3 | L-3₹7.7 L+₹86,995.08 (12.8%)Rejected-Finance AK PO GHANTAPADA TALCHER ANGUL ODISHA | TALCHER | ANGUL | ODISHA | L-3 | Rejected-Finance SINCE THE BIDDER IS NOT L-1 | |
| 4 | L-4₹7.8 L+₹96,606.48 (14.2%)Rejected-Finance AT REMUAN HATATOTA TALCHER DIST ANGUL 759100 | TALCHER | ANGUL | ODISHA | 759100 | L-4 | Rejected-Finance SINCE THE BIDDER IS NOT L-1 | |
| 5 | L-5₹9.2 L+₹2.3 L (34.2%)Rejected-Finance AT BRAHMAN SASAN PO TALCHER DIST ANGUL ODISHA 759102 | TALCHER | ANGUL | ODISHA | 759102 | L-5 | Rejected-Finance SINCE THE BIDDER IS NOT L-1 |
| Sl No | Description | Qty | Unit | M/S. S.K.ENGINEERING L4 | TRISHAKTI ENGINEERING L6 | SANJAY KUMAR SINGH L3 | SIVA SHEKHAR SAHOO L5 | MESSERS UTKAL ELECTRICALS L2 | M/s Santoshi Maa Industries L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. (Above 10.00 metre and upto 12.00 metre) | 29 | Nos. | 4,201 ₹1,21,829 | 4,800 ₹1,39,200 | 4,065 ₹1,17,885 | 4,946 ₹1,43,434 | 3,400 ₹98,600 Lowest | 3,523 ₹1,02,167 |
| 2.00 | Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. | 22 | Set | 3,246 ₹71,412 | 3,900 ₹85,800 | 3,142 ₹69,124 | 3,882 ₹85,404 | 3,050 ₹67,100 | 2,725 ₹59,950 Lowest |
| 3.00 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. | 7 | NOS. | 298 ₹2,086 | 460 ₹3,220 | 300 ₹2,100 | 351 ₹2,457 | 260 ₹1,820 Lowest | 265 ₹1,855 |
| 4.00 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) V shape cross arm for two 11 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as rea u i red. | 7 | NOS. | 1,048 ₹7,336 | 1,520 ₹10,640 | 1,500 ₹10,500 | 1,234 ₹8,638 | 850 ₹5,950 Lowest | 950 ₹6,650 |
| 5.00 | Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required. | 14 | SET | 240 ₹3,360 | 189 ₹2,646 Lowest | 200 ₹2,800 | 282 ₹3,948 | 210 ₹2,940 | 215 ₹3,010 |
| 6.00 | Supplying of 11KV,10KN Polymer pin insulator | 48 | Nos. | 75 ₹3,600 Lowest | 284 ₹13,632 | 120 ₹5,760 | 88 ₹4,224 | 121 ₹5,808 | 120 ₹5,760 |
| 7.00 | Supplying of 11KV,70KN polymer disc insulator for 11KV over head lines | 78 | Nos. | 497 ₹38,766 | 750 ₹58,500 | 500 ₹39,000 | 585 ₹45,630 | 680 ₹53,040 | 480 ₹37,440 Lowest |
| 8.00 | Erection of disc/ pin insulator for 11 KV over head lines as required. | 126 | SET | 72 ₹9,072 | 80 ₹10,080 | 50 ₹6,300 Lowest | 84 ₹10,584 | 75 ₹9,450 | 66 ₹8,316 |
| 9.00 | Supply of 6 SWG G.I wire. | 192.4 | Kgs. | 60 ₹11,544 Lowest | 92 ₹17,700.8 | 90 ₹17,316 | 70 ₹13,468 | 80 ₹15,392 | 82 ₹15,776.8 |
| 10.00 | Erection of G.I wire 8/6 SWG including binding etc as required. | 103.6 | Kg | 17 ₹1,761.2 | 12 ₹1,243.2 | 10 ₹1,036 Lowest | 19 ₹1,968.4 | 15 ₹1,554 | 16 ₹1,657.6 |
Tender Value
₹12.6 L
EMD Value
₹15,700
Closing Date
16 May 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO EnM LINGARAJ AREA
OFFICE OF THE GENERAL MANAGER LINGARAJ AREA, AT/PO- DEULBERA COLLIERY, DIST- ANGUL, ODISHA, 759102
Re-arrangement of F-06 (3.3KV, LTS) feeder of Dera DLB colony to facilitate space for new DAV school, Lingaraj Area that is to be constructed at CMPDI Camp at Dera Chhak Premises of Lingaraj Area
2025_MCL_334872_1
GM/LA/SO/EnM/e-Ten/25-26/09 Dt-02.05.25
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
LINGARAJ AREA
AS PER NIT
4 documents required · 4 mandatory
₹15,700
3 Sept 2025
5 May 2025
19 May 2025
6 May 2025
16 May 2025
6 May 2025
6 May 2025 - 9 May 2025
Amount
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. (Above 10.00 metre and upto 12.00 metre)
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) V shape cross arm for two 11 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as rea u i red.
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required.
Supplying of 11KV,10KN Polymer pin insulator
Supplying of 11KV,70KN polymer disc insulator for 11KV over head lines
Erection of disc/ pin insulator for 11 KV over head lines as required.
Supply of 6 SWG G.I wire.
Erection of G.I wire 8/6 SWG including binding etc as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Supplying and erection of a set of cross bracing FRLSame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height , complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Erection of cradle guard as required.
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required.
Dismantling of over head lines comprising of copper/ aluminium over head conductor, Gl. wire, cross arms, insulators etc. as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Providing and making steel pole collar with cement concrete (1 cement: 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted)
Supply of clamps with M.S. nut,bolts and washers as required.
Supply and Erection of 11KV ,800Amp,3 Phase double Break GOAB Horizontal Type With all accessories etc as requird.
Supply and Erection of 11KV ,800Amp,3 Phase Polymer Resettable Drop Out Fuse With all accessories etc as requird.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: One or more coats on old work (1mtr length for pole demarcation)
Lettering with black Japan paint of approved brand and manufacture (For pole & feeder numbering)
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
MESSERS UTKAL ELECTRICALS (BID ID -1153379)
SANJAY KUMAR SINGH (BID ID -1153183)
M/S. S.K.ENGINEERING (BID ID -1152744)
SIVA SHEKHAR SAHOO (BID ID -1153337)
TRISHAKTI ENGINEERING (BID ID -1152789)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_347281.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .