| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | L1 | Accepted-AOC Due to being L1 | |
| 2 | L2₹6.0 L+₹81,670 (15.8%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹6.3 L+₹1.1 L (21.3%)Rejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹6.5 L+₹1.4 L (26.6%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹8.6 L+₹3.5 L (66.8%)Rejected-Finance 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
1 Dec 2020, 6:00 pmClosed
GE UTILITIES
GE UTILITIES UDHAMPUR PO GARHI PIN 182121
Repair/Maintenance of Perimeter lights, street lights and connected works at CPH area under GE Utilities Udhampur
2020_MES_392240_1
GE/U-64/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITIES UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹20,000
Yes
4 Jan 2021
3 Nov 2020
3 Dec 2020
3 Nov 2020
1 Dec 2020
17 Nov 2020
Amount
Taking down carefully existing unserviceable street light fittings of any capacity & size from pole/buildings and refixing the same on pole/ building after making the fitting serviceable complete all as specified and directed. Note:- (i) Spare parts required for replacement shall be measured and paid separately under relevent items of DCS. (ii) The cost of Replacement of minor Parts i.e. nuts/bolts,connectors etc are deemed to be included in this item.
S&F in replacement of open construction, electromagnetic type, vacuum imprignated , copper wound ballast (choke) 240 V supply voltage,50 HZ for HPSV /MH fitting of following capacity: - Make: Havells, CG,Philips, Bajaj
S&F in replacement of HPSV Clear Lamp , 240 V supply voltage,50 HZ of following capacity:- Make: Havells, CG,Philips, Bajaj
S&F in replacement of Metal halide single ended clear tubular lamp (MH SET) , 240 V supply voltage,50 HZ of following capacity:- Make: Havells, CG,Philips, Bajaj
M&L for replacment of old unserviceable/ defective ignitor with new ignitor of HPSV fitting of capacity 70/150/250/400 Watt all as specified. Make: Havells, CG,Philips, Bajaj
M&L for ceramic lamp holder E-27/40 with electrical grade silver plated contacts as required ,suitable for 70/150/250/400 watt HPSV lamp all as specified.
M&L for replacement of old unserviceable rusted GI tubing brackets, 40mm bore, light grade with new GI tubing bracket, 40mm bore, light grade, 1.20 metre length ,made to shape including MS clamp with nuts, bolts and washers etc complete all as specified and directed.
S&F moduler box made of FRP / impact resistance plastic & heat resistant materials of suitable size to accomodate the fixtures with IP 65, including MCB SPN 20 Amps ,connector terminal block 4 pole suitable for fixing cable connection and fixing to pole with suitable size of clamps,nuts,bolts and painting steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed. Make: Hansu/Sintex
M&L for replacement of old unserviceable cable with PVC insulated 2.5 sqmm, three core, multi stranded, copper conductor cable from junction box/OH line to street light fitting complete all as specified and directed.
Taking out UNSV UG cable of any sizes/ capacity complete all as specified and directed.
M&L for XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 16 sq mm ,4 core, laid in trenches/ducts/through pipe complete all as specified and directed. Make: Havells/Polycab,Golstor
All as per Srl item No 11 here-in-before but cross sectional area 16 sqmm, 2 core.
All as per Srl item No 11 here-in-before but cross sectional area 10 sqmm. 2 core.
M&L for painting to steel tubular pole 9 metre long with two coats of aluminium paint including brackets, clamps, nuts bolts, washer etc. including making yellow and black strips alternatively (30 cm width each) on pole upto 1.5 metre from the ground level and marking of pole Nos with black paint having back ground yellow as per existing complete all as specified and directed.
S &F in replacement of LED energy saving environmental friendly long life exclusive innovative die cast aluminium IP66 flood light of 120 watt suitable for highlighting architectural facade and general purpose lighting complete all as specified and and directed. Make of fitting -CG.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cables, foundation of poles, stays and getting out in any type of soil complete all as specified and directed.
Returning , filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick all as specified and directed.
Removing of excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and directed.
Sand cushioning to under ground cable providing with a layer 8 cm before laying of cable and 15 cm after laying, jointing and testing of the cable all as specified and directed. Note: Punned thickness of sand shall be measured.
Brick covering with width equal to the length of the brick as mechanical protection to cable using sub class ‘B’ bricks, laid flat of size 230mmx115mmx75mm complete all as specified and directed.
S&F in replacement MCCB 4 pole ,Ics=100%Icu- 16/18 KA, 415 Volts, 63 Amps ,with thermal adjustable and fixed magnetic setting with extended terminals suitable for isolation complete all as specified and directed. Make: Havells/L&T/CG/Siemens
S&F in replacement MCCB 4 pole ,Ics=100%Icu- 16/18 KA, 415 Volts, 100 Amps ,with thermal adjustable and fixed magnetic setting with extended terminals suitable for isolation complete all as specified and directed. Make: Havells/L&T/CG/Siemens
M&L for GI tubing, light grade, 50mm bore including necessary clamps for the protection of the cable ,laid in trenches/under road/path complete all as specified and directed.
M&L in replacement vaccum pressure impregnated copper blast for CFL 11W/13W Make: Bajaj/CG/Philips/Havells
M&L in replacement CFL 11W/13W pin type. Make: Bajaj/CG/Philips/ Havells.
M&L in replacement of non rectrofit CFL 13/18 Watt double 'U' cross pin type Make: Bajaj/CG/Philips/Havells
S&F in replacement lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F in replacement lamp holder PVC/polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and directed.
S&F in replacement LED lamp 5 Watt complete all as specified and directed.
S&F in replacement LED lamp 9 Watt complete all as specified and directed.
S &F in replacement of LED street light of 90 watt made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built in surge proction device incl 1.5m long bracket and 3 core 1.5 sqmm flexible wire from loop box to fitting alongwith PVC pipe 32mm dia from ground to loop box complete all as spd and directed. Make of fitting -CG.
S&F in replacement of halogen Lamp 1000W 230V for light fitting 1000 W. Make: Havells LHSH10010099 or equivalent.
S&F in replacement of halogen Lamp 500W 230V for light fitting 500 W. Make: Havells LHS10050099 or equivalent.
M & L for inreplacement of polycarbonate globe with gallery 250mm dia round suitable for upto 40/60W GLS lamp/ CFL and fixing to the post as per sample.
M & L for inreplacement for polycarbonate globe with gallery 300mm dia round suitable for upto 40/60W GLS lamp/ CFL and fixing to the post as per sample.
Supplying fabricating and fixing in replacement of MS clamps for fixing street light fitting, main switches including MS nuts, bolts and washers all as directed.
Material and labour in replacement of PVC insulated multi stranded aluminum conductor PVC cable sheathed 10 Sqmm twin core and making connections of street light fittings with overhead lines/UG Cable complete all as specified and directed. Make: Plaza/ Paragon/ Kalinga.
S &F in replacement of LED street light of 60 watt made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built in surge proction device incl 1.5m long bracket and 3 core 1.5 sqmm flexible wire from loop box to fitting alongwith PVC pipe 32mm dia from ground to loop box complete all as spd and directed. Make of fitting -CG.
S&F in replacement LED lamp 18/20 watt all as specified and directed by Engr-in-Charge.
S&F in replacement MCB TPN 63 Amps with PVC modular box including accessories complete all as specified & directed by Engr-in-Charge.
proach associates
vijay kumar gupta and co
MOHAN LAL AND SONS
R K BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .