| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-AOC AT MAGURGANDAPATNA PO BHARATPUR P S KENDRAPADA DIST KENDRAPADA | CUTTACK | ODISHA | 754134 | L1 | Accepted-AOC successful L1 bidder for the NIT | |
| 2 | L2₹3.0 L+₹60,205 (25.3%)Rejected-Finance | L2 | Rejected-Finance Rejected due to L2 bidder | |
| 3 | L3₹3.0 L+₹64,690 (27.2%)Rejected-Finance | L3 | Rejected-Finance Rejected due to L3 bidder | |
| 4 | L4₹3.8 L+₹1.4 L (59.0%)Rejected-Finance B 35 INDUSTRIAL ESTATE ROURKELA INDUSTRIAL ESTATE SUNDERGARH ODISHA 769004 | SUNDARGARH | ODISHA | 769004 | L4 | Rejected-Finance Rejected due to L4 bidder |
Tender Value
₹3.7 L
EMD Value
₹4,600
Closing Date
11 Apr 2023, 5:00 pmClosed
Staff Officer (EnM) CWS(X) Talcher
Sri. P R Mohapatra, Ch. Mgr(X), CWS(X)Talcher MCL, PO-Balanda, Angul, Odisha, M no. 9438877985, email- soenmcwst(at)gmail.com.
Iinsulation and recoiling of the old and used coils of windings of the two power transformers 5000KVA - 33/3.3KV and 5000KVA - 33/3.3KV.
2023_MCL_276864_1
MCL/CWST/EnM/TRNF /eT/22-23/39 Date 30.03.23
Open Tender
Electrical and Maintenance Works
Item Rate
25 days
Transformer section CWS(X) Talcher
As per NIT
4 documents required · 4 mandatory
₹4,600
2 May 2023
31 Mar 2023
13 Apr 2023
1 Apr 2023
11 Apr 2023
1 Apr 2023
1 Apr 2023 - 5 Apr 2023
Amount
Item Description/ Heading
Re-insulation and recoiling of 3Nos old and used primary coils of 5MVA 33/3.3 KV Power Transformer with proper grade of insulation. i. Covering should be TPC ii. Dimensions and other insulation should be exactly as per old coils. Primary coil data: Type-Disc coils 1. 99.9% Electrolytic Bright annealed copper strip with TPC. 2. No of Conductor: (i) For DISC coil = 1 3. size of conductor: Bare: 8.5mm X 1.9mm TPC: 9.0mm X 2.4mm 4. No of Discs : 62 As per Sample / Old Coil 5. Coil Size: ID:475mm, OD:570mm and HT:770mm 6. Weight of each coil: 270 Kg (including insulation) 7. No. of coils: Three(03) 8. Tap Range : +7.5% to -15% ( Tap lead positions AS PER SAMPLE /OLD COIL) Detail scope of work: 1. Scraping of the old insulation, acid washing and pre annealing for all bend straightening of the disc coils. Straightening of the bend portions through roller die, final annealing and covering with four layers of Kraft papers of specific sizes as required, with in clock and anti clock direction with overlapping and bringing the insulated conductor as per specification provided. 2. Formation of disc coils with all lock joint cut spaces as required, pre-compressed press- boards for separators and winding the coils with sticks if required. Finally placement of the coils in heat chamber and pressing the same till the desired specifcations are achieved. (total cost including materials, manpower,packging and forwarding transport to and fro and other overheads)
Re-insulation and recoiling of 3Nos old and used primary coils of 5MVA 33/3.3 KV Power Transformer with proper grade of insulation. i. Covering should be QPC ii. Dimensions and other insulation should be exactly as per old coils. Primary coil data: Type-Disc coils 1. 99.9% Electrolytic Bright annealed copper strip with QPC. 2. No of Conductor: (i) For DISC coil = 1 3. size of conductor: Bare: 9.2mm X 2.0mm WPC: 9.8mm X 2.6mm 4. No of Discs : 40 As per Sample / Old Coil, TURN/DISC:-25 approx. 5. Coil Size: ID:515mm, OD:640mm and HT:610mm 6. Weight of each coil: 291 Kg (including insulation) 7. No. of coils: Three(03) 8. Tap Range : +10% to -10% ( Tap lead positions AS PER SAMPLE /OLD COIL) Detail scope of work: 1. Scraping of the old insulation, acid washing and pre annealing for all bend straightening of the disc coils. Straightening of the bend portions through roller die, final annealing and covering with four layers of Kraft papers of specific sizes as required, with in clock and anti clock direction with overlapping and bringing the insulated conductor as per specification provided. 2. Formation of disc coils with all lock joint cut spaces as required, pre-compressed press-boards for separators and winding the coils with sticks if required. Finally placement of the coils in heat chamber and pressing the same till the desired specifcations are achieved. (total cost including materials, manpower, transport to and fro and other overheads)specifcations are achieved. (total cost including materials, manpower,packging and forwarding transport to and fro and other overheads)
Total impact of GST for the purpose of CTC
J B ELECTRICALS
Orissa Engineering Udyog Pvt. Ltd.
REMAG ELECTROS PVT. LTD.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_286619.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .