Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC 110 5 BONOMALI NASKAR ROAD BEHALA PARNASHREE PARNASHREE KOLKATA WEST BENGAL 700060 | KOLKATA | WEST BENGAL | 700060 | L1 | Accepted-AOC Being L1 bid | |
| 2 | L2₹28.9 L+₹1.7 L (6.13%)Rejected-Finance 22A ASWINI DUTTA ROAD KOLKATA 700029 | KOLKATA | WEST BENGAL | 700029 | L2 | Rejected-Finance Being L2 bid | |
| 3 | L3₹29.0 L+₹1.7 L (6.30%)Rejected-Finance | L3 | Rejected-Finance Being L3 bid | |
| 4 | L4₹29.5 L+₹2.3 L (8.34%)Rejected-Finance 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L4 | Rejected-Finance Being L4 bid | |
| 5 | L5₹41.2 L+₹14.0 L (51.3%)Rejected-Finance 51 1 FULBAGAN ROAD BAGHAJATIN KOLKATA 700086 WEST BENGAL | KOLKATA | WEST BENGAL | 700086 | L5 | Rejected-Finance Being L5 bid |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
27 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) (CGN) KOLKATA
GE (I) (Coast Guard Navy) Military Engineer Services Damodar Complex Naval Transit Accommodation Hastings, Kolkata700 023
MODIFICATION TO FIRST FLOOR OF SHAH NAWAS BLDG AND PROVN OF STANDBY WATER SUPPLY PUMPS WITH CONNECTED ACCESSORIES INCLUDING KMC DOMESTIC WATER SUPPLY CONNECTION AT KOLKATA UNDER GE (I) (CGN) KOLKATA
2023_MES_620868_3
NIT No 8701/36/2023-2024/10/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) (CGN) KOLKATA
CLASS D AND CATEGORY a(i) or a(ii)
8 documents required · 8 mandatory
₹500
GE (I) (CGN) Kolkata
₹52,000
Yes
10 Jan 2024
30 Nov 2023
28 Dec 2023
30 Nov 2023
27 Dec 2023
8 Dec 2023
Amount
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed by Engineer in charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and fair complete all as specified and as directed.
Material and labour for glazed, colour ceramic wall tiles (group B III), 450 mm X 300 mm X 8 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed.
Material and labour for non skid, rectified, colour ceramic floor tiles (group B II), area of each tile exceeding 0.04 sqm but not exceeding 0.12 sqm, minimum 7 mm thick in floors including 15 mm thick screed bed or bedding in cement mortar(1:6) set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and as directed.
Material and labour for machine cut Kota stone slab flooring 20 to 25 mm thick over cement screed bed of 15 mm thick in cement mortar 1:3, laid and jointed with grey cement slurry, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Material and labour for brick work with fly ash bricks of class designation 7.5 as per IS 12894: 2002, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
Supply and fixed exposed type hydraulically regulated door closers, universal closer, bottle type (type A), Designation No. 2, suitable for 36 kg to 60 kg mass of doors & 701 mm to 850 mm width of door, aluminium alloy non porous body and black plate, aluminium alloy piston or pack piston/ pillion, anodized finish not be less than Grade AC 15 of IS 1868 : 1996 with transparent anodic film as per IS 3564: 1995 complete all as specified and as directed.
Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water complete all as specified and as directed.
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and fair complete all as specified and as directed.
Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces on ceilings in cement mortar 1:4 finished even and fair complete all as specified and as directed.
Material and labour for 2 mm thick wall care cement base putty on wall surface to prpare the surface even and smooth complete all as specified and as directed.
Material and labour for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer over putty to match the existing surfaces complete all as specified and as directed
Material and labour for preparation of new or previously untreated plastered/gypsum ceiling surfaces and applying two coat of oil bound distemper over a coat of suitable dry wall complete all as specified and as directed.
Material and labour for powder coated aluminium frame for doors, windows, ventilators (thickness of powder coating not less than 50 micron) with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
Material and labour for powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section (thickness of powder coating not less than 50 micron) weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws etc. complete all as specified and as directed.
Supply & fix sheet glass, ordinary quality, 5.5 mm thick and glazed with oil putty or fixed with beads in square exceeding 0.5 Sqm in each pane complete all as specified and directed.
Supply and fixed 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed.
Supply and fixed in repairs health faucet with jet spray, 1.5 metre long, cast copper alloy, nickel chromium plated finish, 15 mm bore, 100 mm long with 1.5 metre long stainless steel shower hose and mounting device attached to wall complete all as specified and as directed by Engineer-in-Charge.
Supply and fixed in repairs 15 mm nominal size, nonrising spindle type fancy pillar taps as per IS 8931: 1993, cast copper alloy body with knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
Supply and fixed in repairs 15 mm nominal size, nonrising spindle type fancy bib taps as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
Supply and fixed in repairs 15 mm nominal size, nonrising spindle type fancy stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
Supply and fix Aluminium deco grill Cat No DG-104, 6 mm thick ,cut to required size/shape and fixed in position with aluminium beading complete all as specified and directed by Engineer-in-Charge.
Supply and fixed in repairs stainless steel bracket and holders for 25 mm dia curtain rod, made out of stainless steel sheet of grade X02Cr19NilO (304 S2), surface finish No. 4 as per IS 6911: 1992 complete all as specified and as directed.
Supply and fixed wash basins, vitreous china, white, flat back, size 550 mm X 400 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed.
Supply and fixed in repairs 20 mm dia harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed.
Supply and fixed medium density particle board, 12 mm thick, flat pressed-three layer or multilayer and graded (grade I or grade II), bonded with BWR adhesive, fixed with screws to timber frame work/ steel frame work complete all as specified and as directed.
Supply and fixed vitreous china squatting pan of pattern “long pan”, size 630 mm, white with ‘P’ or ‘S' trap, front or back inlet and foot rests, any pattern and including fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch soil pipe branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
Material and labour for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: wiring color code i.e. Red for phase, Black for neutral and green for earth shall be maintained.)
Material and labour for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: wiring color code i.e. Red for phase, Black for neutral and green for earth shall be maintained.)
Supply and fixed (3 pin and 2 pin) combined modular socket outlets, 6A, 2 modules, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
Supply and fixed ceiling fan, AC, 50 Hz, single phase, 230 V, 1200 mm sweep, 1350 rpm, 3 Nos metal blades protected with corrosion resistance paints, class I type with double insulation, including capacitor to ensure power factor more than 0.9, complete all as specified and directed by Engineer-in-charge.
Supply and fixed batten including tube light 20W, Polycarbonate housing, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 140 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2110, lumen efficacy of minimum 110 lumens per watt, integral electronic driver (SMPS based constant current output) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, CRI greater than 80%, THD less than 20%, CW available CCT of 4000K, power factor of minimum 0.95, life span of minimum 50000 working hours complete all as specified and as directed.
Supply and fixed wall mounted fan, AC, 50 Hz, single phase, 230 V, 400 mm sweep, 1350 rpm, 4 Nos plastic blades, Insulation Class A including capacitor to ensure power factor more than 0.9 complete all as specified and directed by Engineer-in-charge.
Supply and fixed call bell, multi music type suitable for single phase, AC, 240 volts complete all as specified and as directed.
Supply and fixed modular bell push, 6A, 1 module, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
Supply and fixed suitable size fan hook made of mild steel including suitable size of clamp for mounting ceiling fan to be attached with RCC roof, truss roof etc. complete all as specified and directed.
Supply and fixed modular switch, 1 way, 6 A, 1 module complete all as specified and as directed.
Supply and fixed Modular fan regulator, 120 W, 2 modules complete all as specified and as directed.
Supply and fixed single pole blanking plate in DBs of MCB complete all as specified and as directed.
Supply and fixed ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
Supply and fix metal flush box 1 or 2 module complete all as specified and as directed.
Supply and fixed modular white cover plate with frame, 2 modules complete all as specified and as directed.
Supply and fix metal flush box 3 module complete all as specified and as directed.
Supply and fixed modular white cover plate with frame, 3 modules complete all as specified and as directed.
Supply and fix metal flush box 4 module complete all as specified and as directed.
Supply and fixed modular white cover plate with frame, 4 modules complete all as specified and as directed.
Supply and fix metal flush box 6 module complete all as specified and as directed.
Supply and fixed modular white cover plate with frame, 6 modules complete all as specified and as directed.
Supplying and laying CPVC pipes for potable hot and cold water distribution, nominal size 25 mm, pressure class 1, SDR 11 including plain CPVC fittings of pressure class 1, SDR 11 in trenches complete all as specified and as directed.
Supplying and laying CPVC pipes for potable hot and cold water distribution, nominal size 20 mm, pressure class 1, SDR 11 including plain CPVC fittings of pressure class 1, SDR 11 in trenches complete all as specified and as directed.
Cutting hole of area not exceeding 150 sqcm into or through brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete and making good in cement mortar 1:3 or cement concrete M15 (Nominal mix) using 12.5 mm nominal size coarse aggregate complete all as specified and as directed.
Supply and fixed stop valves of PTMT, any colour, high pressure, minimum weight 92 grams, screwed for steel tube for nominal size 20 mm complete all as specified and as directed.
Supply and fixed 25 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete
Supply and fixed 15 mm nominal size, screw down bib taps, cast copper alloy body and body components with crutch handle, nickel-chromium plated finished complete all as specified and as directed.
Supply and fixed rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 2000 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed.
Supply and fixed 50 mm nominal size brass float valve, high pressure, with polythene float and flynut, screwed for iron pipe and fixed complete all as specified and as directed.
Material and labour for plastering 20 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately.
Material and labour for preparing new plaster surfaces walls including chajjas, facias etc. and applying two coat of weather proof acrylic exterior paint (100% Acrylic) over a coat of primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
Supply only liquid water proofing compound.
Material and labour for new water supply connection from KMC main drinking water pipe line by drilling, making hole & thread in pipe for provn of ferrule of size 25 mm dia, stop cock 32 mm dia, GI pipe line 32 mm dia from ferrule to inside the premises of 7 chapel road bldg including labour supervision, drawings agreement, plumbing fees, amounia print etc complete all as specified and directed
Supply, Installation, testing & Commissioning of Energy efficient horizontal or vertical Monoblock submersible pump set suitable for installation in UG Sumps,3 Phase, 415 V, heavy duty body, stainless steel impellers capable of delivering 12 Liters per second at 40 Meters head. Complete all as specified and as directed.
Material and labour fully automatic star delta starter of capacity suitable for monoblock submersible pump capacity upto 15 HP 415V with enclosed with pvc shed for safety of the starter. Complete all as specified and directed.
Material and labour three core flat cable with multistrand copper conductor PVC insulated and sheathed with PVC for submersible/monoblock pump sets of size 6 sqmm 1100 Volts including PVC conduit as specified and directed.
Material and labour for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.6) as per IS 14846: 2000 of preferred materials, nominal size 80 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.
Material and labour for flanged reflux valves of single door, swing check type (non return valves) of nominal pressure (PN 1.6) as per IS 5312 (Part 1): 2004, nominal size 80 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.
Supply and fixed CI foot valve 80 mm with GM working parts as per IS-4038 including all connecting fittings with gasket completa all as specified and as directed.
Material and labour Cutting existing steel tubing of dia 80 mm for alterations or additions (Each cut measured) and Screwing/Provide flanges to existing steel tubing for alterations for additions or lengthening screw/Flange on pipe to form connector complete all as specified and directed. Note : Quoted rate is incl of thread cutting/Flanges,nut,bolts and gaskets etc.
Supplying & fixing to walls and ceilings or laid in floors 80 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Material and labour MS ERW pipe of 100 mm dia with all fittings connection with existing pipelines with one zinc coat of primer and two coats of synthectic enamel paint complete as specified and directed.
Material and labour for PCC road cutting width not exc 400 mm and depth of 300 mm and make good the surface with PCC after laying of water pipelines. Complete all as specified and directed.
Material and labour for cement concrete in foundation, filling and mass concrete in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Material and labour for GI sheet of 2.5 mm thick for cover of UG tank main hole with necessary handles including all necessary welding fabrication as per directed by Enginee-in-Charge Complete all as specified and directed.
Material and labour for earthing complete with galvanised steel pipe electrode 40 mm nominal bore, medium grade, 2.5 metre length buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.25 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from pipe electrode to test point upto 7.5 metre including all as shown in electrical plate No. 2 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
Supply, Installation, testing & Commissioning of Energy efficient Monoblock pump set ,3 Phase, 415 V, heavy duty body, stainless steel shaft, Bronze impellers,capable of delivering 3.2 Liters per second at 32 Meters head with necessary connection from existing tank with PCC foundation. Complete all as specified and as directed. Note : PCC foundation and connectionn pipe is deemed to be incl of quoted rate.
Material and labour fully automatic star delta starter of capacity suitable for monoblock pump capacity upto 7 HP 415V with enclosed with pvc shed for safety of the starter. Complete all as specified and directed.
Supply and fixed 40 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete all as specified and as dircted.
Material and labour for flanged reflux valves of single door, swing check type (non return valves) of nominal pressure (PN 1.6) as per IS 5312 (Part 1): 2004, nominal size 40 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.
Supplying & fixing to walls and ceilings or laid in floors 40 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Design, supply, installation,testing and commissioning of MS Softner Chamber of Capacity 35 m3/Hrs, 9000 GPH, thickness 10 mm for top and bottom cover and 8 mm for vertical portion with anti corrosive bituminus coating of inner portion to achieve NRF 35 m3/hrs, max RF 38.5 m3/hrs, min working pressure 3.5 Kg/cm2, maximum working pressure 7.0 Kg/cm2 of suitable size including PVC brine tank of dimension 1200 mm x1350 mm , control valve, interconnected MS pipeline 100 mm bore heavy grade of suitable grade, outer surafce painting with 2 coats of FRP paint of standard colour after duly preparation and base primer on the surafce, cast steel globe valve 100 mm type PN 1.6 of reputed make like kirloskar/Adco/KSB/Leader, presure gauges & sampling cocks, filling of filter media i,e gravels/pebbles various size as per requirement, sand, PVC strainers, salt for regeneration for testing and cation resin of qty suitable for reducing the hardness to as per IS 10500, limit etc along with provision of manhole for replacement of media and inspection door, suitable size air vent pipe with control valve complete all as specified and as directed. Note: (i) Design calculation to be submitted to the department for size of vessel and qty of media MnO2 and coke catalyst along with filter media chart. (ii) Cast steel globe valve, Pressure gauge, Gravels/pebbles, resin media, brine tank, connected pipeline etc deemed to be inclusive of the quoted rate. (iii) Drawing to be submitted to the department for approval. (iv) Raw water testing to be carried out in an independent NABL accridited/Govt lab before designing the plant and to be submitted to the department. (v) Filter water shall be meet water quality as per defined parameter mentioned at IS: 10500, 2012 (2nd Rev.) and submit test report after duly completion by NABL accreditated/Govt lab(sample should be collected and sealed in front of MES Rep.) (vi) Contractor shall arrange factory visit as and when directed during manufacturing/ fabrication of shell. (vii) The quoted rate also deemded inclusive of imparting training to personnel employed by department for 02 weeks. (viii) PCC foundation and earth work and valve shall be measured and paid separately.
Design, supply,installation,testing and commissioning of MS Oxidation Chamber of Capacity 35 m3/Hrs, 9000 GPH, thickness 10 mm for top and bottom cover and 8 mm for vertical portion with anti corrosive bituminus coating of inner portion to achieve NRF 35 m3/hrs, max RF 38.50 m3/hrs, min working pressure 3.5 Kg/cm2, maximum working pressure 7.0 Kg/cm2 of size suitable including interconnected MS pipeline with 100 mm bore heavy grade of suitable length with outer surafce painting with 2 coats of FRP paint of standard colour after duly preparation and base primer on the surafce, presure gauges & sampling cocks, filling of filter media i,e gravels/pebbles various size as per requirement,sand, PVC strainers and MnO2 agent (minimum 65% purity) of qty suitable for removal of iron to satisfactory limit etc along with provision of manhole for replacement of media and inspection door complete all as specified and as directed. Note: (i) Design calculation to be submitted to the department for size of vessel and qty of media MnO2 and coke catalyst along with filter media chart. (ii) Pressure gauge, MnO2 filter media and hard coke catalyst, connected pipeline deemed to be inclusive of the quoted rate. (iii) Drawing to be submitted to the department for approval. (iv) Raw water testing to be carried out from an independent NABL accridited/Govt lab before designing the plant and to be submitted to the department. (v) filter water shall be meet the water quality as per defined parameter mentioned at IS: 10500, 2012 (2nd Rev.) and submit test report after duly completion by NABL accreditated/Govt lab(sample should be collected and sealed in front of MES Rep.) (vi) Contractor shall arrange factory visit as and when directed during manufacturing/fabrication of shell. (vii) The quoted rate also deemded inclusive of imparting training to personnel employed by department for 02 weeks. (viii) PCC foundation and earth work and valve shall be measured and paid separately.
Material and labour for Cast steel Globe Valves 100 mm flanged ends, drilled to ANSI B16.5 RF , Class 150#, Hand wheel operated, Bolted bonnet, rising spndle, CS to ADTM A216 Gr.WCB body and bonnet, 13% Cr. Steel trims, incl taking down old one Complete all as specifie and directed.
Supply,installation,testing and commissioning of air compressor for oxidation chamber of tank capacity 250 litrs, single cylinder ,, piston displacement 23.2 CFM, with suitable capacity of motor (Make - Crompton/ Kirloskar/ABB) including DOL starter Make-L&T/C&S/BCH including copper cable of approx length 20 RM from nearest panel, earthing, air filter for dust particle prevention of 3 micron, pressure realease valve, connected with suitable size of medium grade SS pipe from air compressor to oxidation chamber all as specified and as directed. Note: (i) Cost of motor, S.S. pipeline, DOL starter, connecting cable, earthing and any other required accessories deemed to be inclusive of quoted rate. (ii) PCC foundation and earth work shall be measured and paid separately. (iii) Necessary Test report to be submitted to the department.
EAST COAST STANDARD PRODUCTS
Rounaq Enterprise
EASTERN REFRIGERATION AND ELECTRICAL CO
NUPUR CONSTRUCTION
SPECIAL CONCRETE AND CONSTRUCTION CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .