Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC MANNI MOUNTA COMPLEX NEAR SGPGI RAEBARELI ROAD LUCKNOW 226014 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226014 | L1 | Accepted-AOC Acceptance Of Tender | |
| 2 | L2₹24.1 L+₹2.7 L (12.5%)Rejected-Finance D 2 36 VIBHUTI KHAND GOMATI NAGAR LUCKNOW UTTAR PRADESH 226010 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226010 | L2 | Rejected-Finance Not L1 |
| Sl No | Description | Qty | Unit | COOLING CENTRE L1 | Lucknow Refrigeration L2 |
|---|---|---|---|---|---|
| 1.00 | Dismantling and taking down old cold room including various components of refrigeration system such as compressors, condensers, insulations, doors etc and depositing in MES store yard with and including demolition of foundation for facilitating renewal of BER Cold Room complete. | 1 | Job | 50,000 ₹50,000 Lowest | 86,000 ₹86,000 |
| 2.00 | Supply, installation, testing and commissioning of Walk-in Cold Room of nominal size 24'x13'x9' for medical storage consisting of walls and ceiling panels made out of SS-304 (inner and outer skin) of 24 SWG sheet 80 mm thick ecofriendly cyclopentane PUF insulation and floor insulation using 80 mm thick PUF slab with SS inside and PGI outside. The system shall include 2 Nos air cooled condensing units each having capacity not less than 44400 Btu/Hr (1 Working & 1 Standby with auto change over and run-time equalisation between working and standby units) with scroll/ reciprocating compressors operating on R404A refrigerants designed to maintain a temperature of +2°C to +8°C. The cold room door shall be of size 34"x78" SS 304 swing type with 3 Nos heavy duty hinges, 80 mm insulation, door heaters, digital temperature indicators and a controller unit. The work includes the supply and installation of required copper piping with insulation, ball valves in suction and discharge lines, all safety features, manual lock inside, internal override, internal electric hooter, external key lock, indoor to outdoor communication cable, condensor stand with protective shed for condensing units, PCC foundation works, electrical wiring with MCB DBs/MCBs, LED lighting and stainless steel 304 racks - 11 Nos of size 7 ft x3.5 ft x 7.5 ft (H) with 3 shelves made of 3 mm thick SS sheet complete in all respect in confirmation to relevant standards and best engineering practices. Notes :- (i) All items / components / accessories which are useful and necessary for efficient working of the Walk-in Cold Room shall deemed to be included in it irrespective of the fact whether such items are specifically mentioned in it or not. (ii) The work shall be carried out through OEM or his authorized agency. Contractor with consultation of OEM shall submit detailed drawing of walk-in cold room alongwith position and dimension of rack, railing, indoor unit etc for approval by GE before installation. (iii) Refrigerant and drain pipes shall be laid on proper support and tray as recommended by OEM. (iv) Log data meter showing minimum past 24 hrs data. (v) False ceiling alongwith accessories required to be removed during the erection of the unit shall be made good as required. | 1 | Job | 19,35,000 ₹19,35,000 Lowest | 22,90,000 ₹22,90,000 |
| 3.00 | S&F ABC powder fire extinguisher Mono Ammonium Phosphate (MAP 90 based portable stored pressure) of capacity 6.0 kg. | 2 | Each | 15,000 ₹30,000 | 4,500 ₹9,000 Lowest |
| 4.00 | S&F Sign board of size 1.0 m x 0.6 m made of white acrylic sheet 2 mm thick and writing “COLD STORAGE FOR MEDICAL STORE DEPTT” with arial black font of size not less than 100 mm and not more than 150 mm and fixing accessories on wall with suitable supports as required. | 1 | Each | 5,000 ₹5,000 Lowest | 8,500 ₹8,500 |
| 5.00 | S&F GI earth strip of size 32x6 mm (to be measured beyond 7.5 m length). | 15 | RM | 1,500 ₹22,500 | 250 ₹3,750 Lowest |
| 6.00 | M&L for earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth strip 32 x 6 mm upto 7.5 m by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate No 3 of MES SSR Part-I (2009) and testing on completion with and including PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 6 mm dia M.S bars 3 Nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work as required. | 2 | Each | 50,000 ₹1,00,000 | 6,200 ₹12,400 Lowest |
Tender Value
₹24.2 L
EMD Value
₹48,420
Closing Date
30 Jan 2026, 6:00 pmClosed
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, LucknowCantt, Lucknow-226002
SPECIAL REPAIRS TO AC PLANT INSTALLED AT MEDICAL STORE DEPT OF CH (CC) AGAINST BER UNDER GE (E/M) LUCKNOW
2025_MES_743981_2
CWE/LKO/EM/T-115 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
LUCKNOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE E/M LUCKNOW
₹48,420
Yes
7 Apr 2026
9 Jan 2026
6 Feb 2026
9 Jan 2026
30 Jan 2026
23 Jan 2026
9 Jan 2026 - 23 Jan 2026
Dismantling and taking down old cold room including various components of refrigeration system such as compressors, condensers, insulations, doors etc and depositing in MES store yard with and including demolition of foundation for facilitating renewal of BER Cold Room complete.
Supply, installation, testing and commissioning of Walk-in Cold Room of nominal size 24'x13'x9' for medical storage consisting of walls and ceiling panels made out of SS-304 (inner and outer skin) of 24 SWG sheet 80 mm thick ecofriendly cyclopentane PUF insulation and floor insulation using 80 mm thick PUF slab with SS inside and PGI outside. The system shall include 2 Nos air cooled condensing units each having capacity not less than 44400 Btu/Hr (1 Working & 1 Standby with auto change over and run-time equalisation between working and standby units) with scroll/ reciprocating compressors operating on R404A refrigerants designed to maintain a temperature of +2°C to +8°C. The cold room door shall be of size 34"x78" SS 304 swing type with 3 Nos heavy duty hinges, 80 mm insulation, door heaters, digital temperature indicators and a controller unit. The work includes the supply and installation of required copper piping with insulation, ball valves in suction and discharge lines, all safety features, manual lock inside, internal override, internal electric hooter, external key lock, indoor to outdoor communication cable, condensor stand with protective shed for condensing units, PCC foundation works, electrical wiring with MCB DBs/MCBs, LED lighting and stainless steel 304 racks - 11 Nos of size 7 ft x3.5 ft x 7.5 ft (H) with 3 shelves made of 3 mm thick SS sheet complete in all respect in confirmation to relevant standards and best engineering practices. Notes :- (i) All items / components / accessories which are useful and necessary for efficient working of the Walk-in Cold Room shall deemed to be included in it irrespective of the fact whether such items are specifically mentioned in it or not. (ii) The work shall be carried out through OEM or his authorized agency. Contractor with consultation of OEM shall submit detailed drawing of walk-in cold room alongwith position and dimension of rack, railing, indoor unit etc for approval by GE before installation. (iii) Refrigerant and drain pipes shall be laid on proper support and tray as recommended by OEM. (iv) Log data meter showing minimum past 24 hrs data. (v) False ceiling alongwith accessories required to be removed during the erection of the unit shall be made good as required.
S&F ABC powder fire extinguisher Mono Ammonium Phosphate (MAP 90 based portable stored pressure) of capacity 6.0 kg.
S&F Sign board of size 1.0 m x 0.6 m made of white acrylic sheet 2 mm thick and writing “COLD STORAGE FOR MEDICAL STORE DEPTT” with arial black font of size not less than 100 mm and not more than 150 mm and fixing accessories on wall with suitable supports as required.
S&F GI earth strip of size 32x6 mm (to be measured beyond 7.5 m length).
M&L for earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth strip 32 x 6 mm upto 7.5 m by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate No 3 of MES SSR Part-I (2009) and testing on completion with and including PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 6 mm dia M.S bars 3 Nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work as required.
stage.html
html • 0.04 MB
technical_837374.pdf
techsummary_837374.pdf
finance_837374.pdf
BOQ Comparative Chart
xlsx
finsummary_837374.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.10 MB
BOQ_837374.xls
BOQ • 0.34 MB
TenderEMT115.pdf
Tender Documents • 0.58 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .