Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹10.0 LAccepted-AOC SHOP NO 25 SHOP NO 25 GLOBE MARKET NEAR MEERA GHATI CHOWK KARNAL KARNAL HARYANA 132001 | KARNAL | HARYANA | 132001 | 1 | Accepted-AOC . | |
| 2 | 2₹12.1 L+₹90,700 (8.07%)Rejected-AOC B 46 INDUSTRIAL AREA SECTOR 59 NOIDA UP 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | 2 | Rejected-AOC .. |
Tender Value
₹8.3 L
EMD Value
₹16,620
Closing Date
18 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE PHED Sohna
EE PHED Sohna
LabSohna831WQMS4rth
2022_HRY_203597_1
LabSohna831WQMS4rth
Open Tender
Civil Works
Works
Sohna
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
₹16,620
Yes
30 Mar 2022
12 Jan 2022
19 Jan 2022
12 Jan 2022
18 Jan 2022
12 Jan 2022
90 days
Amount
Spectrophotometer –Thermo Fisher/ WTW (Xylem), HACH with 5 Year (AMC) and with Standard Chemical/ Solution & CRMs (Nitrate,Iron,Sulphate,Flouride) for 200 Tests. Specifications: "The Spectrophotometer will be dual beam (viz. UV- Visible) operation and with the reference cell position for kinetics application. It will mandatorily have an 8- cell carousel. The spectrophotometer must have room-light resistance, allowing lid-open operation for improved speed and convenience. The Spectrophotometer will have option of automated cell changers and cell holders, sipper, and fiber optic probes for measurements outside of the sample compartment. It must accommodate high throughput measurements and temperature control. The Spectrophotometer will have following features: i. Spectrophotometer will be Double Beam(UV- Visible)/Reference Cell ii. It is will have High resolution touchscreen user interface. The spectrophotometer must be capable of operating through computeralso. iii. There will be 8-position cell changer with switchableturret iv. It will have onboard methods, reporting and data export v. It is capable of open-lidoperation. vi. There will be room lightresistance. vii. It will havesipper(optional) viii. It must have optional facility for 4-position cell changer (long path cells) and Peltier-thermostat single cell holder (20 °C - 60°C) Specifications: Detector Type Dual Silicon Photodiodes Display 7-inch colour touchscreen, high definition, 800 × 1280 pixels Photometric Accuracy Instrument ±0.002A at 0.5A ±0.004A at1.0A ±0.008A at2.0A Wavelength Accuracy ±0.5 nm Baseline Flatness ±0.002A Compartments 8-position cell changer (standard) Drift (At 500 nm after 1-hour warmup) <0.0005A/Hr Keypad Touchscreen Lamp Xenon Flash Lamp (>5 years typical, 3 years guaranteed) Noise (RMS at 500 nm 60 consecutive measurements) ≤0.00020Aat0Aat260and500nm ≤0.00030Aat1Aat260and500nm ≤0.00040Aat2Aat260and500nm Optical Design Double Beam Photometric Display -3A to +5A Photometric Range –2A to+3.5A Photometric Repeatability ±0.001A at 1A measured at 1.0A at 546 nm Spectral Bandwidth 2 nm Stray Light < 1.0%T 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO2) Wavelength Data Interval 0.1 nm, 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm Wavelength Range 190 nm – 1100 nm Wavelength Repeatability < ±0.2 nm Wavelength Scan Speed Slow, medium, and fast - up to 1600 nm/min Computer operation: The spectrophotometer can be operated from compatible computer and software. Computer and operational software to run Spectrophotometer will be a part of the spectrophotometer. Connections Single USB-A supports flash memory devices for method and data storage
Supply of Double Distillation Make- Borosil all quartz Vertical complete in all respect.with 5 Year (AMC) Specifications: All Quartz Double Distillation Unit Demountable Boiler Panel Series, Vertical Model with Distillation Apparatus Power Supply Capacity 2.5 Ltr/hr
Supply of Weighing Balance Make-MettlerToledo complete in all respect. With 5 Year (AMC) Specifications: Analytical Balance Capacity 220 gm Accuracy 00.1 mg with internal calibration Pan Size Ø 90 mm. Standard Values Repeatability (5% Max) 0.015 mg Repeatability (Max) 0.08 mg Minimumweight(USP) 30 mg Minimum weight (U=1%, k=2) 3 mg PermissibleValues Repeatability(5%Max) 0.02 mg Repeatability(Max) 0.1 mg Linearity ± 0.05 mg Stabilization time 2 seconds AdjustmentInternal Verification Yes OIML Class I Display LCD (with backlight) Keypad 14 keys Protection class IP 43 Databases 5 USB-A (interchangeable) 2 USB-B 1 RS 2322 Wi-Fi 802.11 b/g/n Power supply 12 ÷ 16 V DC Power consumption 3 W Weighing pan dimensions ø 90 mm open-work ø 85 mm standard (option)
Supply of TurbidityMeter Benchtop Make- Eutech, Hach, Lovibond, Thermo Fisher Scientific WITH Standared solution complete in all respect.CRMs(10,100,200,800)with 5 Year (AMC) Specifications: Range: 0-4000 NTU; Certification: CE, FCC, EC, EN, UL STD Communication: RS 232, USB via adapter Compliance: ISO Data Log: 1000 total logs, includes reading log, verification log and calibration log, Date Time, User Display: LCD graphic, backlit, menu controlled Interface: RS 232, USB via adapter, external printer, barcode scanner, PC Light source: Light-emitting diode (IR LED)/ Tungsten Filament Lamp Measurement method: Nephelometric Operating temperature range: 0 - 50 °C Power requirements (Voltage): 100 - 240 VAC with Lab station, Battery Operated 4 x 1.5 V, type AA for approx. 3,000 measurements Resolution: 0.001 NTU; Repeatability ±1% of reading or 0.01 NTU whichever is greater Accuracy: ± 2% of reading plus 0.01 NTU from 0 - 1000 NTU, ±5% of reading from 1000 - 4000 NTU or better Reading Modes: Single, Intelligent Reproducibility and Plausibility Check (IRPC) procedure Regulatory: Meets ISO 7027, DIN EN 27027 Response time: <15 seconds 28x60 mm (1.10x2.36 in.), 20 ml sample volume Calibration Point Automatic 3-point calibration Weight approx. 0.6 kg (without batteries) Dimension 236 x 86 x 117 mm Source Lamp: LED Stabilization time: Immediately Storage conditions: -20 to 65 °C Units: FNU and NTU Relative Humidity Yearly mean: < 75 %; 30 days/year: 95 %; Other days: 85 % Type of Protection: IP 67
Supply of Deep Freezer with Temperature Controller Make- Blue Star,Cellfrost, Voltas With all respect and with 5 Year (AMC) Specifications Double door deep fridge • Capacity-300 ltr • Heavy duty wheel • Enabled temperature controller to check & maintain inside temperature • Shelf Material/Coolpad: Toughened Glass • Aesthetic soft look design. • UV grade plastic material for long-lasting appearance • Door lock for restricted accessibility • Castor wheels for easy mobility • Environment friendly CFC free insulation.
Supply of Calibrated Weights Make - Radwag, Mettler Toledo, complete in all respect.with 5 Year (AMC) Standard Weight Box Class F1 capacity 1 mg to 200 gm with NABL Accredited Lab Calibration Certificate (Set of 23 wire weights)
Supply of Hygrometer Make - HTC instruments, Testo, Thermo Electric Technologies complete in all respect.with 5 Year (AMC) Temp Range -500C ~ +700C Temp. Measuring Accuracy: ± 10C Temp. Resolution: 0.10C Humidity Measuring Range: 10% RH ~ 99% Humidity Accuracy: ±5% RH Humidity Resolution: 1%
Supply of Thermometer simple and with probe Make - LT, HTC instruments, Hicks complete in all respect.with 5 Year (AMC) Digital LCD Thermometer with sensor probe
APHA BOOK (American Public Health Association) Standard Methods For the examination of water Latest edition
Aaxis Nano Technologies Pvt. Ltd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .