Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical M S ASHAPURI INFRACON PVT LTD VILLAGE AND PO HURLA TEHSIL BHUNTER DISTT KULLU H P | Admitted-Fee/PreQual/Technical |
Tender Value
₹1.1 L
EMD Value
₹2,300
Closing Date
28 Dec 2025, 11:00 amClosed
XEN Electrical Division No. 1 Shimla
The Executive Engineer Electrical Division No-1 HPPWD Shimla-9
Providing Illumination of murals Installed on Ground and eighth floor of Armsdale Phase-III building HP Secretariat Shimla-2.
2025_PWD_124131_6
Electrical Division-I dated 22.12.2025
Open Tender
Electrical Works
Percentage
180 days
SHIMLA
As Per tender documents
11 documents required · 11 mandatory
₹350
₹2,300
24 Aug 2026
22 Dec 2025
29 Dec 2025
22 Dec 2025
28 Dec 2025
22 Dec 2025
S/E of LED Downlighter surface square with CRCA/PDC body and diffuser The fitting should be installed on existing surface The job includes carriage, erection, making connections testing and commissioning of the fittings.
Specification of LED fittings:
Wattage of LED fittings As per following parameter.
Total lumens of the fittings. as per wattage
Diffuser Polycarbonate diffuser/PMMA
Operating voltage 140 V to 270 V, AC supply or better.
Input frequency 50 Hz + 1 Hz
Power factor Minimum 0.90
Luminaire efficacy >100 lm/w
Color rendering index CRI shall be greater than 80
Working/ operating temperature 00 to + 450c or better
Color temperature 30000K + 10%
Electronic Driver
Drive current (LED) As per OEM.
Operating voltage 140 V to 270 V, AC supply or better.
Type of driver Constant current output driver
THD Less than 10%
Surge Protection 2.5 KV minimum
Efficiency Driver >85%
Protection Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver 2 years against manufacturing defect.
Fixture Should comply with LM 79 test from UL/NABL lab.
LED Type/ Make/ Model Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.
Life of LED 50000 burning hours at 70% lumen maintenance
LED Downlighter 1000 Lumens
S/E of LED Batten with polycarboante body and diffuser The fitting should be installed on existing surface/recess The job includes carriage, erection, making connections testing and commissioning of the fittings.
Specification of LED fittings:
Wattage of LED fittings As per following parameter.
Total lumens of the fittings. as per wattage
Diffuser Polycarbonate diffuser/PMMA
Operating voltage 140 V to 270 V, AC supply or better.
Input frequency 50 Hz + 1 Hz
Power factor Minimum 0.90
Luminaire efficacy >100 lm/w
Color rendering index CRI shall be greater than 80
Working/ operating temperature 00 to + 450c or better
Color temperature 30000K + 10%
Electronic Driver
Drive current (LED) As per OEM.
Operating voltage 140 V to 270 V, AC supply or better.
Type of driver Constant current output driver
THD Less than 10%
Surge Protection 2.5 KV minimum
Efficiency Driver >85%
Protection Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver 2 years against manufacturing defect.
Fixture Should comply with LM 79 test from UL/NABL lab.
LED Type/ Make/ Model Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.
Life of LED 50000 burning hours at 70% lumen maintenance
LED Downlighter 2000 Lumens
S/E of LED Batten with polycarboante body and diffuser The fitting should be installed on existing surface/recess The job includes carriage, erection, making connections testing and commissioning of the fittings.
Specification of LED fittings:
Wattage of LED fittings As per following parameter.
Total lumens of the fittings. as per wattage
Diffuser Polycarbonate diffuser/PMMA
Operating voltage 140 V to 270 V, AC supply or better.
Input frequency 50 Hz + 1 Hz
Power factor Minimum 0.90
Luminaire efficacy >100 lm/w
Color rendering index CRI shall be greater than 80
Working/ operating temperature 00 to + 450c or better
Color temperature 30000K + 10%
Electronic Driver
Drive current (LED) As per OEM.
Operating voltage 140 V to 270 V, AC supply or better.
Type of driver Constant current output driver
THD Less than 10%
Surge Protection 2.5 KV minimum
Efficiency Driver >85%
Protection Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver 2 years against manufacturing defect.
Fixture Should comply with LM 79 test from UL/NABL lab.
LED Type/ Make/ Model Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.
Life of LED 50000 burning hours at 70% lumen maintenance
LED Flood Light 240/250Watt
LED Flood Light 70W
S/E of LED Batten with polycarboante body and diffuser The fitting should be installed on existing surface/recess The job includes carriage, erection, making connections testing and commissioning of the fittings.
Specification of LED fittings:
Wattage of LED fittings As per following parameter.
Total lumens of the fittings. as per wattage
Diffuser Polycarbonate diffuser/PMMA
Operating voltage 140 V to 270 V, AC supply or better.
Input frequency 50 Hz + 1 Hz
Power factor Minimum 0.90
Luminaire efficacy >100 lm/w
Color rendering index CRI shall be greater than 80
Working/ operating temperature 00 to + 450c or better
Color temperature 30000K + 10%
Electronic Driver
Drive current (LED) As per OEM.
Operating voltage 140 V to 270 V, AC supply or better.
Type of driver Constant current output driver
THD Less than 10%
Surge Protection 2.5 KV minimum
Efficiency Driver >85%
Protection Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver 2 years against manufacturing defect.
Fixture Should comply with LM 79 test from UL/NABL lab.
LED Type/ Make/ Model Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.
Life of LED 50000 burning hours at 70% lumen maintenance
LED Track Light 30 Watt
S/E of LED Batten with polycarboante body and diffuser The fitting should be installed on existing surface/recess The job includes carriage, erection, making connections testing and commissioning of the fittings.
Specification of LED fittings:
Wattage of LED fittings As per following parameter.
Total lumens of the fittings. as per wattage
Diffuser Polycarbonate diffuser/PMMA
Operating voltage 140 V to 270 V, AC supply or better.
Input frequency 50 Hz + 1 Hz
Power factor Minimum 0.90
Luminaire efficacy >100 lm/w
Color rendering index CRI shall be greater than 80
Working/ operating temperature 00 to + 450c or better
Color temperature 30000K + 10%
Electronic Driver
Drive current (LED) As per OEM.
Operating voltage 140 V to 270 V, AC supply or better.
Type of driver Constant current output driver
THD Less than 10%
Surge Protection 2.5 KV minimum
Efficiency Driver >85%
Protection Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver 2 years against manufacturing defect.
Fixture Should comply with LM 79 test from UL/NABL lab.
LED Type/ Make/ Model Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.
Life of LED 50000 burning hours at 70% lumen maintenance
LED Panel 4320 Lumens
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required.
Armoured cable 6 sq. mm (twin core)
Providing and fixing G.I/MS Pipe/rod hanging arrangement for mounting LED Flood light on it and placing G.I barbed wire around it for protection against monkey menance, this shall includes fixing the pole arrangement with welding if required and fixing the flood light on it, painting the pole/rod in black for protection against corrosion complete in all respects as required with best satisfaction of Engineer incharge.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Conditions:-
Rates should be quoted for all heights including all leads and lifts for internal and external works for all floor levels.
Useful materials should be handed over to the Assistant Engineer Electrical Sub Division No.II, Sectt. Shimla, otherwise credit for useful materials will be charged.
Sample of all the material to be used on work shall be got approved from the Engineer-in-charge in advance before actual use on work and any or all of the material which are available as per Indian standard in the market should confirm to bureau of indian standards.
It is certify that the tender is being called on emergentnature in exigency of Public insterest.
stage.html
html • 0.02 MB
tech_bid_open.pdf
cancelled_1.pdf
pdf • 0.37 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.34 MB
DeclarationNEW.pdf
Additional Documents • 0.01 MB
SBD_11illumination.pdf
Tender Documents • 3.75 MB
BOQ_182438.xls
BOQ • 0.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .