| 1 | L1₹33.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bid found in order | |
| 2 | L2₹39.2 L+₹3.6 L (10.2%)Rejected-AOC DHOBI MOHALLA BATMALOO SRINAGAR 190010 J K | SRINAGAR | SRINAGAR | J K | 190010 | L2 | Rejected-AOC Other than Lowest bid | |
| 3 | L3₹41.5 L+₹5.9 L (16.6%)Rejected-AOC | L3 | Rejected-AOC Other than Lowest bid | |
| 4 | L4₹42.9 L+₹7.3 L (20.4%)Rejected-AOC | L4 | Rejected-AOC Other than Lowest bid | |
| 5 | L5₹43.4 L+₹7.8 L (22.0%)Rejected-AOC | L5 | Rejected-AOC Other than Lowest bid |
Tender Value
Refer Docs
EMD Value
₹75,000
Closing Date
5 Jun 2023, 6:00 pmClosed
GE 874 EWS C/O 56 APO
GE 874 EWS C/O 56 APO
REPAIR MAINTENANCE OF EXTERNAL AND INTERNAL ELECTRIC SUPPLY AND EXTERNAL WATER SUPPLY NETWORK AT CHOWKIBAL AND NIYARI
2023_MES_593702_1
GE 874/EWS-18/2023-24
Open Tender
Civil Works
Item Rate
180 days
Kupwara
As per NIT and tender documents
7 documents required · 7 mandatory
₹500
GE 874 EWS
₹75,000
Yes
15 Aug 2023
8 May 2023
6 Jun 2023
8 May 2023
5 Jun 2023
22 May 2023
8 May 2023 - 15 May 2023
Amount
EM Portion
Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
M & L for point wiring One light /one fan/one bell point controlled by one switch, with PVC insulated unsheathed single core multistranded copper conductor 1.5 sqmm, 1100 volts grade cable, FRLS, drawn through PVC casing caping including accessories and provinsing of PVC boxes for mounting switches, switch socket, fan regulator, provn of modular terressa plate Irene stripes, No of modules as required on site or as directed by Engineer-in-Charge including one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) earth wire and connected to earth dolly. Make of wire :-Havells/ Finolex/L&T. Make of casing caping- Poly plast/ pressfit/ Presto plast
As per Item No 2 above but point wiring for One socket outlet 5 pins 5 amps controlled by one switch on same board .
As per Item No 2 above but point wiring One socket outlet 5 pins 5 amps controlled by one switch on independent board.
All as per item No 2 herein before but wiring with 2.5 sqmm copper wire ( FRLS) and 1.5 sqmm earth wire for socket outlet 6 pin 15 amps on independent board.
S&F switch piano flush button single pole, one way 5 amps complete all as specified and directed. Make - Anchor/SSK/Cona Havells .
S&F socket outlet multi 5 pins 6 amp, complete all as specified and directed. Make - Anchor/SSK/Cona Havells
S & F switch socket combination 2 in 1, 6A flush type.Make - Anchor/SSK/Cona Havells
S & F switch socket combination 3 pin 16A, flush type .Make - Anchor/SSK/Cona Havells
S&F Modular switch piano flush button single pole, one way 6 amps complete all as specified and directed. Make - Anchor/SSK/Cona Havells.
S&F Modular socket outlet multi 5 pins 6 amp, complete all as specified and directed. Make - Anchor/SSK/Cona Havells
S&F Modular socket outlet multi 5 pins 16 amp, complete all as specified and directed. Make - Anchor/SSK/Cona Havells
S&F Modular switch piano flush button single pole, one way 16 amps complete all as specified and directed. Make - Anchor/SSK/Cona Havells .
S&F ceiling rose, PVC/poly carbonate, isolated body three terminal complete all as specified and directed. Make - Anchor/SSK/Cona Havells
S&F lamp holder angle type PVC/Poly carbonate type insulated body with back plate suitable for batten/wall fitting complete all as specified and directed. Make - Anchor/SSK/Cona Havells
Supply and fix LED Bulb 9 Watt . Make Havells/Bajaj
S&F sheet metal enclosure for DBs (single door type) when MCBs to be used single pole and neutral 4 way including blanking plate as reqd with 200 amps rated busbar 240V fixed sunk/flush to the wall or niche complete all as specified and directed. Make : Legrand, Havells/HPL.
S&F sheet metal enclosure for DBs (single door type) when MCBs to be used single pole and neutral 8 way including blanking plate as reqd with 200 amps rated busbar 240V fixed sunk/flush to the wall or niche complete all as specified and directed. Make : Legrand, Havells/HPL.
S&F sheet metal enclosure for DBs (single door type) when MCBs to be used single pole and neutral 12 way including blanking plate as reqd with 200 amps rated busbar 240V fixed sunk/flush to the wall or niche complete all as specified and directed. Make : Legrand, Havells/HPL.
S&F single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 amp complete all as specified and directed. Make : Legrand, Havells/HPL.
S&F MCB single pole & neutral 40 to 63 Amps 230 Volts'C' series, 10 KA complete all as specified and directed.Make: Havels /Legrand L&T,
S&F MCB single pole & neutral 32 Amps 230 Volts'C' series, 10 KA complete all as specified and directed.Make: Havels /Legrand L&T,
S&F MCB's single pole 240 volts 6 to 32Amps 10 KA 'C' series, all as specified and as directed by Engr -in-Charge. Make : Leggrand/Havells/HPL.
M & L for sub main wiring with two single core 6 sqmm PVC insulated and unsheathed 1100 volts grade, stranded copper conductor FRLS ISI marked drawn into & including medium grade PVC conduit/ casing caping 25 mm dia with all fittings and accessories and one continuous run of 6 sqmm copper conductor PVC insulated (green colour) as earth wire fixed into PVC casing / conduit (not less than 25mm outer dia) with all fittings and accessories fixed conealed/ surface including taking down old unserviceable submain wiring and making good disturbe surface complete all as specified and directed.Make of cable- Havells ,Plaza, Policab.Make of Casing Caping - Poly plast/ pressfit/ Presto plast.
M & L for sub main wiring with two single core 4 sqmm PVC insulated and unsheathed 1100 volts grade, stranded copper conductor FRLS ISI marked drawn into & including medium grade PVC conduit/ casing caping 25 mm dia with all fittings and accessories and one continuous run of 4 sqmm copper conductor PVC insulated (green colour) as earth wire fixed into PVC casing / conduit (not less than 25mm outer dia) with all fittings and accessories fixed conealed/ surface including taking down old unserviceable submain wiring and making good disturbe surface complete all as specified and directed.Make of cable- Havells ,Plaza, Policab.Make of Casing Caping - Poly plast/ pressfit/ Presto plast.
M & L for sub main wiring with two single core 2.5 sqmm PVC insulated and unsheathed 1100 volts grade, stranded copper conductor FRLS ISI marked drawn into & including medium grade PVC conduit/ casing caping 25 mm dia with all fittings and accessories and one continuous run of 2.5 sqmm copper conductor PVC insulated (green colour) as earth wire fixed into PVC casing / conduit (not less than 25mm outer dia) with all fittings and accessories fixed conealed/ surface including taking down old unserviceable submain wiring and making good disturbe surface complete all as specified and directed.Make of cable- Havells ,Plaza, Policab.Make of Casing Caping - Poly plast/ pressfit/ Presto plast.
S & F in replacement LED light fitting 1x9W/10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.Make:-Havells/Syska/Wipro
Supply and fixing in replacement LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.Make:-Havells/Syska/Wipro
Supply and fixing in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. complete all as specified and directed.Make:-Havells/Syska/Wipro
Supply and fixing in replacement round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.all as specified and directed.Make:-Havells/Syska/Wipro
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.Make:-Havells/Syska/Wipro
S&F Bed side designer lamp, 5 watts, with LED lamp, including all wiring and switches required, with terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body.
supply and fix in replacement Decorative gate light made up of high grade unbreakable polycarbonate material suitable for retrofit LED 20W B22 basewitth 1x20 watt LED lamp complete all as specified and directed by Engr-in-charge . Make Havells, Philips ,C&S
supply and fix in replacement unique LED flood/ focus light 70 W LED 6500 K with IP 65 protection complete all as specified and directed by Engr-in-charge Make Havells, Philips ,C&S
M&L rewinding of exhaust fan with super copper enamelled wire with suitable gauge, varnishing, oiling and greasing of any make of size 450 mm sweep by dismantling its parts, capacitor 4 Mfd by replacing petty items such as nuts & bolts,bearing & washers, cleaning of exhaust fan body and its blade by cleaning agent, assembling, and connecting and testing Complete.
Supply and Replacement of unsv heating helemant with new one capacity of 1500 Watts (triangle type) for 25 Ltr geysers.
Supply and Replacement of unsv heating elemant with new one capacity of 2000 Watts for 25 Ltr geyser(triangle type).
Repair/Replacement of Thermostat 7''/9" suitable for 25/50 ltrs capacity water geyser with automatic thermal cutout fixed in repair and including testing, complete alla specified.
Repair/Replacement of copper Geyser Assembly with rubber paking for 25/50 ltrs capacity water geyser with automatic thermal cutout fixed in repair and including testing, complete alla specified.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathed of PVC tape overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable of size 16 Sqmm complete all as specified and directed
Supply and fixing 1100 volts grade heavy duty cable PVC insulated sdranded aluminium conductor, served with inner sheathed of PVC tape overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable of size 10 Sqmm complete all as specified and directed
Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0 mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, common salt, charcoal and testing on completion, all as specified and directed.
Excavation in trenches not exc.1.5 mtr wide and not exc.1.5 m in depth for foundation of poles, stay assembly and laying of LT/HT cable as in any type of soil and getting out, complete all as specified and directed.
All as per item above but depth exceeding 1.5 m and not exceeding 3 m.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil, complete all as specified and directed.
Removal of excavated material to a distance not exc.50 m and depositing where directed at a level not exceeding 1.5 mtr above starting point.
Sand cushioning to underground cables 8 cm below the cable before laying and 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, complete all as specified.
Material and labour for kiln burnt Sub class 'B' bricks laid dry , flat , width wise along the length of cable in trenches after sand cushioning for protection of under ground cable complete all as specified and directed.
Plain Cement concrete in Bed of poles streets and stays 1:4:8 type D-2 using 40 mm graded crushed stone aggregate all as specified directed.
Plain Cement concrete 1:2:4 type C-2 using 40 mm graded crushed stone aggregate as in pole coping and stay assembly all as specified directed.
Plain Cement concrete in foundation of poles streets and stays 1:3:6 type D-2 using 40 mm graded crushed stone aggregate all as specified directed.
Taking down from trench/duct/wall/in floors etc. old unserviceable LT 1100 volts XLPE/ PILCA cable and Supply & Laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles and taking out old u/s damaged cables of sizes 16 sq mm, 4 core.
All as per item above but size 35 sq mm, 3.5 core
All as per item above but size 70 sq mm, 3.5 core
All as per item above but size 120 sq mm, 3.5 core
S & F in replacement steel tubular swaged poles erected truly vertical or planted as strut complete with 300 x300x 6 mm thick mild steel base plate, welded to pole, B-118 final, taper cap, bolts, nuts & screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II. type 410 SP-31 (9.0 metres long) including drilling of holes of reqd size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminium paint over a coat of red oxide zinc chrome primer and with two coats of black bitumenous paint internally & portion embedded in concrete, making five black & yellow bands at lower portion of pole each 300mm wide alternately, and making pole No. with black paint at suitable height all as specified and directed.
S&F in replacement of Cross arms, bracing, supports clamps and back plates, fabricated from structural steel sections incl nuts, bolts, washer, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed incl one primer, one under coat and one finishing coat of aluminium paint over prepared steel surface.
M&L in replacement of ACSR conductor of any size and any type including stretching, fixing and binding to insulator on OH HT/LT line service feeders all as specified including aluminium binding wire or aluminium tapes complete all as specified. This item includes all consumables (such as binding wire and replacement insulators and cross arms, etc., for replacement of damaged ones found after/ during replacement process).
M&L in replacement of Shackle type, porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts grade, 90 mm dia 75 mm height including galvanized mild steel straps of 31 x 3 mm size, 12 mm dia insulator bolts, washers and nuts complete all as specified.
M&L in replacement of Pin type porcelain vitreous white brown or green insulator including one galvanized mild steel spindle, two galvanized iron, washers and one galvanized iron nut, 100 mm height, 65 mm dia for 1100 volt grade all as specified.
M&L in replacement of Stay assembly for electric pole complete with accessories as shown in electrical plate No 1 of SSR Pt-I and drg using loop type insulator, stay clamps, stay rod of 16 mm dia including stay wire of size 7/3.15 mm (excavation and concrete to be measured separately)
Supply only in replacement of off load changover switch 415 volt in sheet metal enclosure 3/4 pole of capacity from 200 Amp complete all as specified and directed by Engr-in-Charge. Make : C&S Cat Patr No -CSCSOF200CO4RE or equvalent.
Painting to LT poles, 09 mtr with cross arms, bracing and clamps with one coat of synthetic enameled paint over one coat of red oxide primer including scrapping the old paint carefully to make smoothen complete and painting strips of Yellow and black from foot of pole upto 5 feet each strip of 30 cm height all as specified and directed.
Restretching of LT /HT ACSR conductor and GI wire of any size and on any type of poles carrying upto six conductors in a span including disconnecting from insulator and rewinding to insulator after stretching with and including aluminium wire including re-fixing/re-adjusting line spans, line separators, cross arms on poles all as specified.
Cutting /Trimming/ Chopping of tree trenches along the overhead lines upto 3 m from elect lines clearance on both sides of HT/LT lines and disposing off the cut tree/ branches site to a distance not exc. 50 m and clearing the site as directed.
Supply and fix cable jointing kit for 1100 volts (Earthed) grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE /(ABC), armoured, Al conductor cable of size 25 sqmm to 50 sqmm
Supply and fix cable jointing kit for 1100 volts (Earthed) grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE /(ABC), armoured, Al conductor cable of size 70 sqmm to 120 sqmm
M&L for Earthing complete with galvanised steel earth plate electrode 60 × 60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion
Supply and fixing LED Flood light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connection cable as recuired complete all as specified and directed .
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including Connection cable as recuired complete all as specified and directed .
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connection cable as recuired complete all as specified and directed .
Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathed of PVC tape overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable of size 16 Sqmm complete all as specified and directed
Taking up or down cast iron water mains bore of pipe 100 mm (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead
Supply and laying Cast iron pipes with spigot and sockets ends centrifugally, Class LA in 100 mm size laid in treanches
Supply & fixing bends (any Type radius and angle tapers any type (striaght, bend, increasing decreasing or double sockets etc ) Tee pieces single branch 'Y' Junction, double branch, cross (all sockets or sockets and spigot) collars caps and plugs upto 150mm bore.
Run lead joint for CI pipe spigot and socket pipes and fittings of 100 mm bore complete all as specified and directed by Engr-in-Charge.
Taking up or down steel tubing of 20mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to credit complete with all fittings & valves etc complete all as specified and directed.
All as per item above but 25mm.
All as per item above but 40mm.
All as per item above but 50mm.
All as per item above but 80mm.
S&F GI water tubing 20mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed by Engr-in-Charge.
All as per item above but 25mm.
All as per item above but 40mm.
All as per item above but 50mm.
All as per item above but 80mm.
S&F gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of bore of 20mm complete all as specified and directed by Engr-in-Charge.
All as per item above but 25mm.
All as per item above but 40mm.
All as per item above but 50mm.
Taking down old unsv old sluice valve and supply and fixing ball valve having SS ball with both CI end flanged, ISI marked, with nuts, bolts and washer and rubber gasket with stainless steel handle over PVC coating complete all as specified and directed for 80 mm bore pipecomplete all as specified and directed. Make - Zoloto/ Bir / BVI
Taking down old unsv old sluice valve and supply and fixing sluice valve cast iron ISI marked with flanged ends drilled with iron wheels head shuts and open direction cast on it class PN 1.6 confirming to IS 14846-2000 including necessary fixing arrengemet such as rubber insulation, packing rings, jointing materials nuts, bolts washer, gasket and packings material etc all as specified and directed for 100 mm dia complete all as specified and directed. Make - Zoloto/ Bir / BVI
Supply and Fixing in rplacement CI Non return valve of size 100mm bore without bypass arrangement swing type confirming to IS 5312-1 flanged end, pressure rating PN 1.6 complete all as specified and directed.
Supply and Fixing in rplacement CI Non return valve of size 80mm bore without bypass arrangement swing type confirming toIS 5312 flanged end pressure rating PN 1.6 complete all as specified and directed.
Lagging to pipes used in internal water supply or plumbing all round with, 25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 for 20 mm dia pipeline complete all as specified and directed.
Lagging to pipes used in internal water supply or plumbing all round with, 25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 for 25 mm dia pipeline complete all as specified and directed.
Lagging to pipes used in internal water supply or plumbing all round with, 40min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 for 40 mm dia pipeline complete all as specified and directed.
Supply and replacement of 10 Sqmm 3 Core submersible copper conductor flat type for submersible pump .
Supply and replacement of 6 Sqmm 3 Core submersible copper conductor flat type for submersible pump .
Dewatering and taking out sludge from tank of size and capacity (10000 to 40000Gln), removing the same to a distance not exceeding 50m with & including, cleaning the sump by wire brushing including ,including brooming down complete incl white washing internally, complete all as directed by the Engr-in-charge.
Material and labour for repair of centrifugal motor pump set 50/60 HP (Rewinding job will be measured seperateley), including removing the motor pump from the foundation, disconnecting from the motor and transporting to the work shop for repair including replacement of worn out impellers-01 set with bronze impellers, replacing bearing No 6308-02 Nos, replacement of worn out bearing housing, replacement of gland bush, unserviceable nut bolts and washers and bringing back the pump to the pump house and coupling the pump with motor and fixing on foundation and testing, complete all as directed.
Material and labour for repair of centrifugal motor pump set 15/ 20 HP (Rewinding job will be measured seperateley), including removing the motor pump from the foundation, disconnecting from the motor and transporting to the work shop for repair including replacement of worn out impellers-01 set with bronze impellers, replacing bearing No 6307-02 Nos, replacement of worn out bearing housing, replacement of gland bush , unserviceable nut bolts and washers and bringing back the pump to the pump house and coupling the pump with motor and fixing on foundation and testing, complete all as directed.
Material and labour for rewinding of 50/60HP centrifugal motor by uncoupling the motor from the pump, removing the motor from the foundation and transportation of the motor to the workshop, opening the motor , taking out burnt out winding, preparing the slot for winding and rewinding of motor with super enamelled copper winding wire of appropriate size and gauge as existing to make the same cap of motor, varnishing and heat drying including scrapping of old paint & repainting with one coat of grey tinted synthetic enamel paint after motor is reassembled and testing complete all as specified and as directed by the Engr-in Charge.
Material and labour for rewinding of 15/20HP centrifugal motor by uncoupling the motor from the pump, removing the motor from the foundation and transportation of the motor to the workshop, opening the motor , taking out burnt out winding, preparing the slot for winding and rewinding of motor with super enamelled copper winding wire of appropriate size and gauge as existing to make the same cap of motor, varnishing and heat drying including scrapping of old paint & repainting with one coat of grey tinted synthetic enamel paint after motor is reassembled and testing complete all as specified and as directed by the Engr-in Charge.
Material and labour for rewinding of 7.5 HP to 10 HP centrifugal motor by uncoupling the motor from the pump, removing the motor from the foundation and transportation of the motor to the workshop, opening the motor , taking out burnt out winding, preparing the slot for winding and rewinding of motor with super enamelled copper winding wire of appropriate size and gauge as existing to make the same cap of motor, varnishing and heat drying including scrapping of old paint & repainting with one coat of grey tinted synthetic enamel paint after motor is reassembled and testing complete all as specified and as directed by the Engr-in Charge.
Material and labour for taking out the submersible pump set and motor assembly of capacity 5 HP to 10 HP from the borewell, by taking out the column pipes with chain pulley block and tripod stand, complete using skilled and experienced labour and transporting the same to workshop for repair and replacement of worn impellers -01 set , replacement of worn out bushings and bearings and transport back repaired pump set back to site after repair and Lowering the same in the bore well after testing complete all as specified and directed by the Engr - in Charge.
Material and labour for rewinding of submersible motor 5 to 7.5HP by taking out the burnt out winding from the strater with PVC insulated copper winding wire of same gauge and size as per existing, replacement of thrust bearing and bushes and testing complete all as specified and as directed by the Engr-in-Charge.
Supply and Fixing in replacement of 1 HP Centrifugal Motor Pump, of head and throughput output as mentioned at site, complete with all related accessoried for installation and operation. Make : Kirloskar/ KSB/ Crompton/ Usha/ CRI/ Greaves/ Havells or equivalent as approved by engineer in charge.
Supply and fixing in replacement of 0.5 HP Centrifugal Motor Pump, of head and throughput output as mentioned at site, complete with all related accessoried for installation and operation. Make : Kirloskar/ KSB/ Crompton/ Usha/ CRI/ Greaves/ Havells or equivalent as approved by engineer in charge.
S&F GI Union 50 mm dia complete all as specified and directed by the Engineer-in-charge.
S&F GI Union 20 mm dia complete all as specified and directed by the Engineer-in-charge.
S&F GI Union 25 mm dia complete all as specified and directed by the Engineer-in-charge.
S&F GI Union 40 mm dia complete all as specified and directed by the Engineer-in-charge.
S&F GI Union 80 mm dia complete all as specified and directed by the Engineer-in-charge.
S&F GI Union 100 mm dia complete all as specified and directed by the Engineer-in-charge.
Developing of borewell by means of compressor of min @ 250 PSI capacity and pumping by means of 25% extra pump capacity until the sand free water obtained and all as specified and directed. Note : All the test to be carried out in front of Engineer - in - Charge and ensure existing yield.
Taking out unserviceable filter media of any sizes from sand filters and pressure filter and depositing not exceeding 100 mtr and replace with following sizes of filter media all as specified and directed.
Supply only filter media of Size of ½ ''
Supply only filter media of Size ¾''
Supply only filter media of Size o 3/16'' to 1/16''
Supply only filter media of Size below 1/16'' (core sand)
Supply only of bleaching powder (Calcium Hypochlorite based only) having minimum chlorine content of 65% (if chlorine content is less, then proportionally more quantity will have to be given) in granular/ powder form for water disinfection, packed in hematically sealed containers. Make Rayalaseema, Altoch, Potterwatt or Aquafit or as approved approved by Engineer-in-Charge.
S&F in replacement 60 HP Star delta starter. Make Havells
S&F in replacement starter for submersible pump 5/7.5 HP. Make Havells
S&F in replacement starter for submersible pump 25 HP. Make Havells
S&F in replacement rubber Star coupling of size L-190 for 40HP Centrifugal pump set complete all as specified
S&F in replacement rubber Star coupling of size L-225 for 60HP Centrifugal pump set complete all as specified
S&F in replacement gland packing of suitable size for 40/60 HP pump all as directed by Engr-in -Charge
S&F in replacement Bearing of suitable size for 40/60 HP pump all as directed by Engr-in -Charge.
S&F in replacement leather gasket suitable for 80/100 mm dia pipe all as directed.
S&F in replacement CI flange for 80/100 mm dia pipe tape all as directed.
S&F in replacement Nut & Bolts 20x50 mm, 20x75mm , 20x100mm all as directed by Engr-in-charge
S&F in replacement Nut & Bolts 15x50 mm, 15x75mm , 15x100mm all as directed by Engr-in-charge
M/S ASHRAF CONSTRUCTIONS
patriotic builders
M/S ABDUL AZIZ MIR
M/S ALBURAQ INFRATECH PRIVATE LIMITED
Bidder Name
patriotic builders
M/S ASHRAF CONSTRUCTIONS
M/S ABDUL AZIZ MIR
M/S MANZOORAHMAD LONE
M/S ALBURAQ INFRATECH PRIVATE LIMITED
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .