| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 CrAccepted-AOC | ₹38.6 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹39.3 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹39.3 Cr | L2 | Rejected-Finance Rejected not being L1 |
| 3 | L3₹41.4 CrRejected-Finance PLOT NO G 36 SECTOR 20 NAVI MUMBAI 400614 | THANE | MAHARASHTRA | 400614 | ₹41.4 Cr | L3 | Rejected-Finance Rejected not being L1 |
| 4 | L4₹54.4 CrRejected-Finance | ₹54.4 Cr | L4 | Rejected-Finance Rejected not being L1 |
Tender Value
₹35.8 Cr
EMD Value
₹15 L
Closing Date
15 Oct 2022, 6:00 pmClosed
Sr DDG and CE
DGNP Mumbai, SBS Road, Lion Gate, Mumbai-400023
PROVISION OF INTEGRATED BOILER SHOP AT NAVAL DOCKYARD MUMBAI
2021_MES_488782_1
DGNP_MES_8532_1
Open Tender
Civil Works
900 days
Naval Dockyard
As per tender documents
8 documents required · 8 mandatory
₹3,000
Yes
DGNP Mumbai
₹15 L
Yes
12 Oct 2023
26 Apr 2022
22 Oct 2022
26 Apr 2022
15 Oct 2022
27 Sept 2022
27 Apr 2022 - 6 May 2022
Amount
LIST OF WORKS (Schedule A Part I to Part XIV)
Total amount of Sch 'A' Part-I (Building Works) brought forwarded from sl page No 34(R).
Total amount of Sch 'A' Part-II (Pile Foundation) brought forwarded from sl page No 35(R).
Total amount of Sch 'A' Part-III (Earth Work and Site Clearance) brought forwarded from sl page No 38(R).
Total amount of Sch 'A' Part-IV (Internal Water Supply and Hot Water Supply) brought forwarded from sl page No 42(RR).
Total amount of Sch 'A' Part-V (Internal Electrification) brought forwarded from sl page No 53( R).
Total amount of Sch 'A' Part-VI (Lightening Protection, HP/LP Air Pumping System, Cooling Appliances) brought forwarded from sl page No 55(R ).
Total amount of Sch 'A' Part-VII (Fire Fighting, UPS System & Fire Detection System) brought forwarded from sl page No 68 (RR).
Total amount of Sch 'A' Part-VIII (External Water Supply) brought forwarded from sl page No 69(R).
Total amount of Sch 'A' part- IX (External Electric Supply) brought forwarded from sl page No 72(R).
Total amount of Sch 'A' part- X (Road / Path) brought forwarded from sl page No 75(RR).
Total amount of Sch 'A' part- XI (Sewage Disposal) brought forwarded from sl page No 78(R)
Total amount of Sch 'A' part- XII (Area Drinage ) brought forwarded from sl page No 80(R)
Total amount of Sch 'A' part- XIII (Demolition & Dismantling) brought forwarded from sl page No 81(R).
Sch 'A' Part- XIV (MISCELLANEOUS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
INTERNAL WATER SUPPLY & HOT WATER SUPPLY
C.P wall mount double Robe Hook fixed to wooden cleats with C.P brass screws, cutting wall/floor and making good the same wherever required, complete in all respect (Make and Sample as approved by GE).
Straight type Macfit single body push fit type WC pan connector with factory supplied spring loaded seal guard of McAlpine, UK with integral single mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I pipe as supplied with the pan connector (Make and Sample as approved by GE) Complete all as directed.
600mm dia
800mm dia
1000mm dia
FIRE FIGHTING :- MS class "C" diesel engine exhaust pipe including all fittings ,clamps,steel support of suitable dia for the engine including 12 mm thick supercera aeramic fibre rope all as directed.
(a) 80mm dia
(b) 100 mm dia
(c) 150 mm dia
Reinforced neoprene rubber vibration eliminilators/expansionjoints( to provide relief form stress at pipe flanges ) suitable for upto 20 kg/cm2 pressure ,complete all as per specification of following sizes:-
(a) 150mm dia
(b) 100mm dia
Gun metal air release valve 25mm dia with all fittings and forged ball valve on headder complete as directed.
FIRE DETECTION SYSTEM Net workable and micro processor based 640 chracters LCD / Touch Screen LCD display network repeater panel displaying all events /detectors, devices status of complete systems in the network. The repeator shall be equiped with mounting options etc. (UL approved) complete in all respect as specified and as directed.
Cabling for fire detection and alarm system with 2 core annealed tinned copper conductor PVC sheathed , flexible, 2x1.5 sq mm armoured cable complete in all respect as specified or indicated including testing on completion.
8 core 1.5 sq mm FRLSH wire from main fire alarm panel to repeater panel (1 pair for power supply , 2 pairs for 2 zones & 1 pair extra ) complete in all respect as specified and as directed.
UPS SYSTEM:- Micro processor / DSP controlled 20 KVA UPS , True Online Double Conversion VFI Technology UPS ( high frequency PWM using IGBT technology ) , working in high hot stand by mode , 3 phase input and 3 phase 415 V out put UPS system , power factor 0.8 and each comprising of the following :- 100% rated rectifier cum charger unit + 100% rated inverter , intergrated in UPS moduleswitch at the inverter out put + 100% rated inbuilt static switches at the static bypass line 100%rated inbuilt maintainanace bypass 100% rated battery circuit breaker. The UPS shall run in hopt stand by mode Inbuilt isolation transformer Battery bank , sealed maintaenance free (SMF) batteries for 20KVA UPS system to provide 30 minutes back up time at full load with suitable no.of batteries having total VAH required per 20 KVA UPS = 38400 with interconnectors, rack and accessories and UPS to battery DC cable upto 5 meters . (Make : Exide / Quanta) for battery and Pegasus , GE,APC,SCHNEIDER, EATON for UPS.
EXTERNAL WATER SUPPLY:- Masonry Chamber 90x90x100 cm internal size, in brick work class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominalsize ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement slurry complete as per standard design and all as directed.
Providing, fixing and testing of packaged fixed skid mounted hydropneumatic system comprising of :- (a) Vertical inline multistage centrifugal pumping set with stainless steel SS-304 stage casing and SS-304 impellers with stainless steel SS-316L shaft as per IEC standards and GJL250 cast iron suction & discharge casing, connected to TEFC ventilated induction motor of 2 pole, 2900rpm, suitable for 400/440 Volts, 3 phase, 50 Hz A.C. (b) Pressure vessel of non corrosive FRP composite construction lined with NSF and/or FDA listed material, like high density polyethylene with fully replaceable polyurethane. Air cell burst pressure of minimum of 5 times the vessel operating pressure and cycle tested for 2,50,000 cycles. No. and capacity of Pressure Vessel – 01 Nos. x 100 Ltrs. (c) Control Panel with programmable logic controller (PLC) for cyclic operation of pumps. Pump working sequence should change after every operation.Contactor overload relays and MCBs should confirm to IEC 898 – 1995/ specifications. Blinking indications for pumps start, trip, low level trip, health supply should be provided in the panel along with the ammeter & voltmeter. Control panel should also consist of cooling fan. (d) Pressure switches bellow type fitted with micro switch and having maximum pressure and differential scale should confirming BS-6134 standards and IP-55 protection class. (e) Stainless steel suction and delevery header, ball valve on each pump on section delivery side, non return valves, Y stainer complete in all respect.
(f) Ball valves to be used should be Hot Pressed brass OT-58 with stainless steel ball and P.T.F.E seal and O-Ring. NRVs to be used should be with Springs and O-Ring arrangement. (g) Complete set system to be mounted on a common base frame and shall follow following duty.For Domestic Water Supply(1working + 1 stand by)Capacity : 180 lpm Head : 50 m
Drainage Sump Pumps : Submersible pumps for basement drainage & Pump Room drainage Submersible single stage single entry pumps with C.I.body and C.I. two vane enclosed type impeller connected to TEFC submersible motor for 415 volts, 3 phase, 50 cycles including MCC panel with level controllers, auto control, sequential change over facility with one proper working at low level & two proper working at high level with an audible alarm including all interconnectivity cables, with both pumps connected to common outlet header including valves, non return valves, lifting chains etc. complete in all respect (one working + one standby/both working in high flow conditions. For Basement Drainage(Solid handiling capacity 12mm)Capacity- 250 lpm (Each)Head - 10 m
Notes : (i) All MCCBs shall be of 35 KA breaking capacity and suitable for motor duty application. (ii) Provision shall be made to ensure system protection from dry running of the pump. (iii) All incomers and Buscoupler breakers shall be electrical and mechanical interlocked with suitable accessories. (iv). 2 Nos. Type-2 SPD 65kA 4P with 1No. Red Indicator Light for SPD with 1Set. SPD Back up fuse 1P 50A 20kA including all necessary accessories.
COOLING APPLIANCES :- Water Purifier having capacity 8 Ltr complete all as specified and as directed.
LP/HP AIR SUPPLY :- Air ompressor multi cylinder reciprocating type air cooled automatic start-stop control splash lubrication, 925RPM, 50LPM 3HP/2.2KW , 10 Kg/Sqcm working pressure, V-belt drive, complete including standard accessories Electric primover suitable for operation on 3 Phase 415V 50Hz AC supply and 300 Ltrs capacity Air receiver, starter, Pressure control switch, safety valve, .ante vibration pads, , etc all confirming to relevant IS including connecting to existing power supply (not exceeding 5 Mtrs) with suitable capacity PVC insulated cable with multistrand copper conductors.Make :- ELGI equipmment model No.TS03 120 HN or equivalant in Kirloskar ,MTI etc. conforming to IS as approved by GE.
MS tubing 40mm dia confirming to ASTM 106 Grade "B" Sch 40 including specials along/across wall / roof /structural sections by electric arc butt welding including provision of openings in wall for passing pipe line all as specified and as directed.
MS tubing 25mm dia confirming to ASTM 106 Grade "B" Sch 40 including specials along/across wall / roof /structural sections by electric arc butt welding including provision of openings in wall for passing pipe line all as specified and as directed.
MS tubing 15mm dia confirming to ASTM 106 Grade "B" Sch 40 including specials along/across wall / roof /structural sections and electric arc butt welding all as specified and as directed.
Ball valve forged brass, micro finish of size 40mm dia flanged ends confirming to IS 3658/relevant IS similar to Zoloto model No.1008B all as specified and as directed.
Ball valve forged brass, micro finish of size 25mm dia flanged ends confirming to IS 3658/relevant IS all as specified and as directed.
Ball valve forged brass, micro finish of size 15mm dia flanged ends confirming to IS 3658/relevant IS all as specified and as directed.
Filter Regulator Lubricant , aluminum alloy body ends screwed confirming to relevant IS suitable for 15mm dia MS pipe all as specified & as directed.
15mm dia Stainless steel quick coupler (Male & female) all as directed.
INTERNAL ELECTRIFICATION
MCB 4 Pole 10 Amps 415V 3 phase 50Hz including sheet metal enclosure all as specified & as directed.
LED light fittng mirror type with high out put diffuser 2 feet, 18 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed. Make & Model : BZRSQL 18L WH OD5D of Bajaj or other equivalent makes mentioned in list of makes.
Surface industrial Batten Tube light - 40W LED, complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as directed. Make & Model : BIPC 40W LEDXE of Bajaj or other equivalent makes mentioned in the list of makes.
Surface mounted Round luminaire - 6W LED, complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as directed. Make & Model : BGSLOSLEEK 6W WH RD of Bajaj or other equivalent makes mentioned in the list of makes.
Highbay luminaire - 200W LED, complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as directed. Make & Model : BGHBM NXTB 260L WH NBSD of Bajaj or equivalent in other makes mentioned in the list of makes.
Highbay luminaire - 80W LED, complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as directed. Make & Model : BGHBM NXTB 104L WH WB SD of Bajaj or equivalent in other makes mentioned in the list of makes.
Surface mounted weather & corrotion proof tube light 40W LED, complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as directed. Make & Model : BIPC 40W LEDXE of Bajaj or equivalent in other makes mentioned in the list of makes.
Bulk head light 10W LED complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as directed. Make & Model : BIBWP 10W LED of Bajaj or equivalent in other makes mentioned in the list of makes.
Fire Exit Sign (Illuminated) with 1x11W CFL, with upto 3 Hrs Battery Backup equivlent to cat no Prolite PEL 111E/M Eit Sign or equivalent as approved by GE.
WALL FAN (450MM sweep) Complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified & as directed.
6 way, single pole and neutral, sheet steel, MCB distribution board, 240 volts with 200 Amps rated bus bar double door on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required, (but without MCB/RCCB/Isolator) and as directed.
FRP Perforated type cable tray width: 150mm, Height: 50mm and 3mm Thick all as directed.
FRP Perforated type Cable tray width: 300mm, Height: 75mm and 5mm Thick all as directed.
FRP Perforated through type tray width: 450mm, Height: 75mm and Thickness: 4mm Bottom sheet is 3m
FRP Ladder type Cable tray width: 600mm and Channel Size 100x35x3mm all as directed.
FRP Ladder type Cable tray width: 900mm and Channel Size 100x35x3mm all as directed.
Modular telephone socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc as required. (i) Telephone socket outlet.
RJ 45 cat 6 jack point all as directed.
EOT CRANE Design, supply, errection, testing and commissioning of 40 Ton EOT crane with approxiately 8.7m span, 9.3m height of lift, double girder indoor type, class 2 (M5), IS-3177 with operation from independently movable pendent push button station as per technical details given in particular specification all as specified & directed. Note: Cost of gantry girder shall be deemed to be included in lumpsum amount quoted for item No 1 of Sch 'A' Part-I.
Design, supply, errection, testing and commissioning of 5 Ton EOT crane with approxiately 8.7m span, 4.2m height of lift, double girder indoor type, class 2 (M5), IS-3177 with operation from independently movable pendent push button station as per technical details given in particular specification all as specified & as directed. Note: Cost of gantry girder shall be deemed to be included in lumpsum amount quoted for item No 1 of Sch 'A' Part-I.
Design, supply test and commissioning of scissor lift movable type with rubberized wheel, battery operated having base platform size 3mx 3m and lifting hight of 4 mtr and lifting load of 500 Kg all as specified & as directed.
Dismantling & removing old servicable 40Ton EOT Crane, 66 feet span including all accessaries complete and handing over to the user all as directed.
LIFT Design, supply, install, testing and commissioning Lift for 08 passengers speed 1.5 m/s, lift with gearless machine single speed motor 415 volts, 3 phase, AC 50 Hz supply confirming to IS-14665, suitable to serve various floors as per details shown on drg with AC variable voltage and variable frequency drive (VVVF drive) complete with all standard accessories, simplex automatic and manual dual controlled operation with/ without attendant, center opening doors with door drive (electric motor driven mechanishm), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without handset (04 nos, one each in car, machine room & near ground floor landing door) complete all as specified and as per OEM instructions.
Design, supply, install, testing and commissioning goods Lift 3000kg capacity, speed 0.5 m/s with gearless machine, single speed motor, Three phase 415V, AC 50HZ supply, confirming to IS-14665, suitable to serve various floors as per detail shown in drg with AC variable voltage & variable frequency drive (VVVF Drive) complete with all standard accessories simplex automatic & manual dual controled operation with / without attendent, centre opening doors with Door drive ( Electric motor Driven mechanism), sliding stainless steel doors, Automatic Rescue Device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without handset (03 Nos, one each in car, Machine room & near Ground Floor Landing door) complete all as specified and as per OEM instructions.
EXTERNAL ELECTRIFICATION : 6.6KV/11KV DUAL VOLTAGE HT SUBSTATION EQUIPMENT, 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker having rupturing capacity 350 MVA, overload and earth fault protection, ammeter, voltmeter and of rating upto 630 Amp, comprising of following:-
(a) One (1) Nos. 6.6KV/ 11KV 630 Amps. 350MVA, 26kA for 1sec. Electrically/ manually operated draw out type vacuum circuit breaker complete with trip free spring charged closing mechanism, necessary auxiliary relays, control switches, emergency hand trip devices and mechanical ON / OFF indicator etc. (b) One (1) Multifunction Meter showing all Electrical Paramater ie Volt, Ampere, KW, KVA, P.F., KWH etc. (c) One (1) digital type ammeter with 6.6KV/ 11KV Cast resin CTs for metering (50/25 /5-5A, CL- 1, 15VA) with ASS and 2 Amp SP MCB. (d) One (1) voltmeter (0-15KV) with VSS. (e) One (1) Set of phase indication lamps with 2Amp SP MCB for protection (Red, Yellow and Blue). (f) One (1) set of Red/ Green indicating lamp for close and open position.
(g) One (1) No. Amper indicating lamp for auto trip. (h) One (1) No. clear indicating lamp for trip circuit healthy. (i) One (1) blue indicating lamp for spring charged. (j) One (1) strip heater to prevent absorption of moisture. (k) One (1) set of 3 O/C + 1E/F (with High Set) Neumerical Relay with 3 Nos. 6.6KV/ 11kV Resin Cast CTs 50/25/5-5A, CL 10P10, 15VA. (l) Master Trip Relay. (m) Trip circuit supervision relay. (n) One (1) No Potential transformer 6.6KV/11KV/√3/110/√3 100 VA burden. (o) One (1) set of 3 Element 24V DC Aux. Relay with H/R flag for tripping of transformer fault i.e OTI, WTI & Buchholz Tripping. (p) One (1) set of 3 Element 24V DC Aux. Relay with H/R flag for Alarm of transformer fault i.e OTI, WTI & Buchholz Alarm (q) One (1) set of 8 stage 24V DC Annunciator with builtin test/Accept/Reset push button alongwith 24V DC Hooter. (r) Master Trip Relay. (s) 12 Window Annunciator, Auxiliary switch/relay, master trip, anti pumping relay Trip Circuit. Supervision relay and other control relays etc as per requirements. (t) Power pack: One (1) set 230V AC /24V DC, Battery Backup, Power pack to operate atleast 5 Nos operation without AC Supply.
1600 KVA 6.6KV-11KV/0.433KV Dual voltage 3phase 50Hz, indoor type copper wound, Dry type cast resin step down transformer complete with all modern fittings as given in the specifications including , lifting lugs, Roller type bi-directional wheels, suitable boxes on both the ends for cable entry & bus duct, winding temprature indication & alarm, earthing terminals, diagram and rating plat etc. as required all as per following details.
(a) 6.6KV-11KV/433V Dual voltage distribution transformer shall be a part of packaged substation which will be housed in the enclosure. The transformers shall be installed in hot, humid tropical atmosphere. All equipment accessories and wiring shall be provided with tropical finish to prevent fungus growth. (b) The transformers shall be dry Type & capable of continuous operation of rated output under the operating conditions of voltage and frequency variations as per statutory limits governed by relevant Indian Standard and Indian Electricity Rules, 1956 / IEC with latest amendments in force. (c) Requirement: 6.6KV-11KV/433V Dual voltage dry type cast resin with OFF LOAD Tap Changer (OCTC), Tapping range +5% to -7.5% in steps of 2.5% (HV side), neutral air cooled, double copper wound, core type suitable for packaged substation housed in a enclosure. (d) Voltage Ratio: No load voltage 11000/433volts within tolerance as stipulated in latest IS standard. (e) Insulating material shall be of proven design. The insulating material shall be class 'F'.
(f) Rating: The transformer shall have a continuous rating as specified at any of the specified tapping position and with the maximum temperature rise specified. (g) Temperature Rise: The maximum temperature rise at the specified maximum continuous output shall not exceed 40°C by thermometer of winding above ambient temperature of 50°C. (h) Type of Load: The transformer shall be suitable for carrying unbalanced load up to 90% load within temperature rise indicated in the Indian Standard specification ‘Guide for loading of dry Transformer. (j) Overloads: The transformers shall be suitable for carrying overload within temperature rise indicated in IS ‘Guide for Loading of dry transformer’. (k) Connections: H.V. Delta and L.V Star connected with neutral brought out on the secondary side for connection to earth; Vector group DYn11 of IS:2026. (l) Each 6.6KV-11KV/433V Dual voltage Step down transformers shall be provided with the following fittings and accessories: Rating diagram and terminal marking plate for transformer .
(m) Lifting lugs for transformer . (n) Bi-directional Rollers. (o) Rating diagram and terminal marking plate for transformer . (p) Earth terminals (2 Nos) for body earthing for transformers . (q) Inspection door for access to terminal connections for transformers (r) Suitable cable termination arrangement for M.V. side with extended Bus bars for cables or Bus duct connection and cable box terminations on H.V. Side, suitable for 3Cx 240/300sq. mm 11 K.V. XLPE Aluminum Conductor cable. (s) Necessary hardware, clamps, lugs etc. for terminations of H.V. Cables on HV side and cable termination on M.V. Side. (t) Winding temperature indicator with contacts for remote alarm and tripping.
SAFETY EQUIPMENTS: Danger notice plate of 1.6mm mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS damps, bolts and nuts of approved size, for HT, 25x20cm size.
Carbon dioxide (CO2) type fire extinguisher with suitable base pipe & horn (conforming to IS 2876 with cylinders fully charged of capacity 9.0 Kgm) all as directed.
Carbon dioxide (CO2) type fire extinguisher with suitable base pipe & horn (conforming to IS 2876 with cylinders fully charged of capacity 4.5 Kgm) all as directed.
G.I buckets of 9 litre capacity paint and written with white paint Fire and mounted on M.S. angle iron bracket of sizes 50 mm x 50 mm x 6 mm thick and 500 mm long including grouting in wall etc. as required including filling with dry sand all as directed.
First aid box as approved by St. John Ambulance Brigade/Indian Red Cross Conforming to IS:2217 - 1963 all as directed.
Shock treatment chart at least in three languages duly mounted on wooden frame with glass as directed.
Elastometic mat 2 mm thick to withstand 1.1KV dielectric strength as per IS 15652/2006 all as directed.
MV DISTRIBUTION PANELS & BOARDS : Main LT PANEL(415V AC3 phase, 4 wire,50 Hz) Supplying of 415V, 3 Phase, 50 Hz., 4 wire system, sheet steel clad, dust and vermin proof cubical and Indoor type floor mounted, free standing extendible type Main LT Panel compartmentalized design and fabricated out of 2 mm CRCA sheet steel complete with copper Bus bars, Electrical interlocks as per the various status of all the equipments indicated on the drawings. Providing & Fixing of base plate / channel, P/F the following Switchgears, complete with earth Bus bar throughout the length of the panel, terminal arrangement for Cables incomings / Outgoings from Top / Bottom as per drawings and as approved by consultant / Engineer- in-Charge, The incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement, detachable gland plates, adequate size cable alley, Sign writing, Painting, Earthing, Numbering, Danger plate etc. complete as required as per specification and drawing approved by GE.
(a) Incomer (1600 KVA) : 1 No. 2500 A, 415V, 50kA (Ics=Icu=Icw =50 KA for 1 second), 4 Pole, Electrical draw out type, Micro-processor based release (for over current, Earth fault and short circuit protections) A.C.B. with all indications, metering, protections, push buttons etc. complete in all respects as mentioned in specifications and as required. each feeder shall have following: (b) Digital flush type class-1.0 accuracy multifunction meter showing V, A, PF, KVAR , KWH, Frequency / Harmonics etc. with 3 Nos. current transformers of 2500/5 ratio, 15 VA Class 1.0 metering. (c) 6 nos NO/NC contacts for remote opening & closing. (d) Red/Green/Amber ON/OFF/TRIP indicating lamps with 2A SP MCB backup protection. (e) 1 set of three phase indicating lamps along with 2A SP MCB backup protection. (f) Spring charge& DC supply healthy indicating lamp with 2A SP MCB backup protection.
(g) Separate set of Class 5P10, 15VA CT of suitable capacity for protection/Capacitor Panel. (h) 24 V DC Shunt trip coil. (j) Motor wound spring closing mechanism. (k) Control MCB, control terminals& wiring as required. (l) Restricted Earth fault relay with 3 Nos. current transformers of 2500/5 ratio, 15 VA Class 5P 10. (m) Undervoltage, Overvoltage & phase reversal relay for persisted voltage of 105-180% & 20-95% of rated voltage. (n) All outgoing feeders shall be provided with one set of three phase R,Y,B indicating lamps along with 2A SP MCB backup portection and 1 Set of ON/OFF/Trip indicating lamps . (o) Bus Bars: A set of TPN Copper bus bar rated for 3000A (after considering all necessary deratings) 3 phase 4wire, 50Hz. A minimum derating factor of 0.75 must be taken for calculation of bus bar sizes. The bus bar size after derating shall be equal to the ampere given in the BOQ. The conductivity of bus bar shall not be less than 58% and earth bus size shall be 10% of phase bus bar. (50kA).
(p) Outgoings : All outgoing shall have Ics = 50 KA (As per SLD). (q) 2 Nos. TPN feeder having 800A TPN MCCB, ON /OFF indication, 1 no. digital MFM (showing all PF/V/A/F parameters) and matching cast resin CT's with control MCB. (r) 3 Nos. TPN feeder having 630A TPN MCCB, ON /OFF indication, 1 no. digital MFM (showing all V/A/F/KW parameters) and matching cast resin CT's with control MCB. (s) 1 Nos. TPN feeder having 400A TPN MCCB, ON /OFF indication, 1 no. digital MFM (showing all V/A/F/KW parameters) and matching cast resin CT's with control MCB. (t) 1 Nos. TPN feeder having 315A TPN MCCB, ON /OFF indication, 1 no. digital MFM (showing all V/A/F/KW parameters) and matching cast resin CT's with control MCB. (u) 5 Nos. TPN feeder having 250A TPN MCCB, ON /OFF indication, 1 no. digital MFM (showing all V/A/F/KW parameters) and matching cast resin CT's with control MCB.
(v) 1 Nos. TPN feeder having 200A TPN MCCB, ON /OFF indication, 1 no. digital MFM (showing all V/A/F/KW parameters) and matching cast resin CT's with control MCB. (w) 2 Nos. TPN feeder having 160A TPN MCCB, ON /OFF indication, 1 no. digital MFM (showing all V/A/F/KW parameters) and matching cast resin CT's with control MCB. (x) 3 Nos. TPN feeder having 100A TPN MCCB, ON /OFF indication, 1 no. digital MFM (showing all V/A/F/KW parameters) and matching cast resin CT's with control MCB. (y) 5 Nos. TPN feeder having 63A TPN MCCB, ON /OFF indication, 1 no. digital MFM (showing all V/A/F/KW parameters) and matching cast resin CT's with control MCB. (z) 1 Nos. TPN feeder having 40A TPN MCCB, ON /OFF indication, 1 no. digital MFM (showing all V/A/F/KW parameters) and matching cast resin CT's with control MCB. (aa) 2 Nos. SPACE suitable for TPN feeder having 250A TPN MCCB. (bb) Other items such as 1 Lot of control wiring 1 Set of designation plates MAIN LT PANEL Described as above complete.
Capacitor Panel-1 (300 KVAR) INDOOR DUTY : INCOMER : 300 KVAR at 415V capacitor panel having 1 no. 630Amps TP Isolator as incomer. Incomer shall have 3 nos indicating lights with control MCB for incoming power, 1 no. Multifunction meter showing V/A/PF parameters with matching cast resin CT's, 3 phase 12 steps automatic power factor correction relay all as per details below:- BUS BAR : A set of TPN Copper bus bar rated for 700A (after considering all necessary deratings) 3 phase 4wire, 50Hz. A minimum derating factor of 0.75 must be taken for calculation of bus bar sizes. The bus bar size after derating shall be equal to the ampere given in the BOQ. The conductivity of bus bar shall not be less than 58% and earth bus size shall be 10% of phase bus bar. (35kA).
OUTGOINGS :1 nos. x 100 KVAR capacitor banks each having 100 KVAR (should offer net capacitance of 100 KVAR at 415V) section will have 250A TP MCCB with 1 no of 200Amps TP capacitor duty contactor, 1 no. 100KVAR 7% harmonic block reactor with 200% linearity class H, Net 133 KVAR Heavy duty capacitor rated at 525V, 1 set lights ON/OFF, 1 set of ON/OFF push buttons, 1 no. CT operated ammeter 0-250amps. 2 nos. x 50 KVAR capacitor banks each having 50 KVAR (should offer net capacitance of 50 KVAR at 415V) section will have 160A TP MCCB with 1 no of 110amps TP capacitor duty contactor, 1 no. 100KVAR 7% harmonic block reactor with 200% linearity class H, Net 62.5 KVAR Heavy duty capacitor rated at 525V, 1 set lights ON/OFF, 1 set of ON/OFF push buttons, 1 no. CT operated ammeter 0-125amps. 3 no. x 25 KVAR capacitor banks each having 25 KVAR (should offer net capacitance of 25 KVAR at 415V) section will have 80A TP MCCB with 1 no of 60amps TP capacitor duty contactor, 1 no. 25KVAR 7% harmonic block reactor with 200% linearity class H, Net 33.5 KVAR Heavy duty capacitor rated at 525V, 1 set lights ON/OFF, 1 set of ON/OFF push buttons, 1 no. CT operated ammeter 0-60amps.
2 no. x 12.5 KVAR capacitor banks each having 12.5 KVAR (should offer net capacitance of 12.5 KVAR at 415V) section will have 40A TP MCCB with 1 no of 40amps TP capacitor duty contactor, 1 no. 12.5KVAR 7% harmonic block reactor with 200% linearity class H, Net 33.5 KVAR Heavy duty capacitor rated at 525V, 1 set lights ON/OFF, 1 set of ON/OFF push buttons, 1 no. CT operated ammeter 0-40amps. Each capacitor bank shall be able to operate in either manual or auto mode individually through APCR relay and separately in auto mode. Actual capacitance value will be high at 525V and each capacitors should be derated to offer value given above at 415V, 01 set of complete wiring.
INDOOR DUTY/ INCOMER: 225 KVAR at 415V capacitor panel having 1 no. 630Amps TP Isolator as incomer. Incomer shall have 3 nos indicating lights with control MCB for incoming power, 1 no. Multifunction meter showing V/A/PF parameters with matching cast resin CT's, 3 phase 12 steps automatic power factor correction relay all as per details below:- (a) BUS BAR: A set of TPN Copper bus bar rated for 700A (after considering all necessary deratings) 3 phase 4wire, 50Hz. A minimum derating factor of 0.75 must be taken for calculation of bus bar sizes. The bus bar size after derating shall be equal to the ampere given in the BOQ. The conductivity of bus bar shall not be less than 58% and earth bus size shall be 10% of phase bus bar. (35kA).
(b) OUTGOINGS: 2 nos. x 50 KVAR capacitor banks each having 50 KVAR (should offer net capacitance of 50 KVAR at 415V) section will have 160A TP MCCB with 1 no of 110amps TP capacitor duty contactor, 1 no. 100KVAR 7% harmonic block reactor with 200% linearity class H, Net 62.5 KVAR Heavy duty capacitor rated at 525V, 1 set lights ON/OFF, 1 set of ON/OFF push buttons, 1 no. CT operated ammeter 0-125amps. (c) 4 no. x 25 KVAR capacitor banks each having 25 KVAR (should offer net capacitance of 25 KVAR at 415V) section will have 80A TP MCCB with 1 no of 60amps TP capacitor duty contactor, 1 no. 25KVAR 7% harmonic block reactor with 200% linearity class H, Net 33.5 KVAR Heavy duty capacitor rated at 525V, 1 set lights ON/OFF, 1 set of ON/OFF push buttons, 1 no. CT operated ammeter 0-60amps.
(d) 2 no. x 12.5 KVAR capacitor banks each having 25 KVAR (should offer net capacitance of 12.5 KVAR at 415V) section will have 40A TP MCCB with 1 no of 40amps TP capacitor duty contactor, 1 no. 25KVAR 7% harmonic block reactor with 200% linearity class H, Net 33.5 KVAR Heavy duty capacitor rated at 525V, 1 set lights ON/OFF, 1 set of ON/OFF push buttons, 1 no. CT operated ammeter 0-40amps. (e) Each capacitor bank shall be able to operate in either manual or auto mode individually through APCR relay and separately in auto mode. Actual capacitance value will be high at 525V and each capacitors should be derated to offer value given above at 415V. (f) 1 set of complete wiring
ISOLATOR ASSEMBLY
LIFT PANEL : 1 No. TPN Incomer feeder having 63A 4P MCCB (16kA) with ON indications, 3 nos. phase indicating lamps to show the incoming power with control MCB all as per details below:- (a) Bus Bar: One set of TPN,CU bus bar rated 100 Amps (after considering necessary deratings of 75%) for phases and neutral for half capacity of phases. (b) Outgoings:- All outgoing shall have Ics = 16 KA (As per SLD). (c) 2 Nos. 40A TPN feeder having 40A TPN MCB with ON indication. (d) 1 Nos. 25A DP feeder having 25A DP MCB. (e) 1Nos. SPACE suitable for 63A TPN feeder having 63A 4P MCCB with isolable neutral, ON indication. (f) Other items such as 1 Lot of control wiring and 1 Set of designation plates.
LIFT PANEL : 1 No. TPN Incomer feeder having 100A 4P MCCB (16kA) with ON indications, 3 nos. phase indicating lamps to show the incoming power with control MCB all as per details below:- (a) Bus Bar: One set of TPN, CU bus bar rated 150 Amps (after considering necessary deratings of 75%) for phases and neutral for half capacity of phases. (b) Outgoings:- All outgoing shall have Ics = 16 KA (As per SLD). (c) 2 Nos. 63A TPN feeder having 63A TPN MCCB with ON indication. (d) 1 Nos. 25A DP feeder having 25A DP MCB. (e) 1Nos. SPACE suitable for 63A 4P feeder having 100A 4P MCCB with ON indication. (f) Other items such as 1 Lot of control wiring and 1 Set of designation plates.
Digging of Horizintal boring of size 200mm dia for laying of PVC insulated and PVC sheathed / XLPE power cable including provision of 150mm HDPE pipe complete in all respect and removal of debris outside MoD land all as directed.
SUPPLY & INSTALLATION OF BUS BAR TRUNKING (SANDWITCH TYPE)
Adaptor box housings fabricated out of 14G CRCA powder coated (as approved) sheet steel for the Rising Mains fitted with following rating MCCB. The adaptor box shall be totally factory assembled complete with solid aluminium busbar links of rated capacity for connection of outgoing vide MCCB to Risings Mains. The adaptor box should be complete with suitable size of glands plate for incoming cables.
Reducer suitable for Rising Mains, of capacity 800 Amps to 200 Amps TPN making proper connections, testing and commissioning as described in above items.
Rising Main consisting of total Aluminium/ GI. enclosure, TPN high electrolytic conductivity copper conductor, sandwich Busbars covered with 2 layers of Myler insulation, No coloured sleeves, integral earth bus suitable for operation on 415V/650V 3 phase, 4 wire 50 cycles AC supply system. The construction should be such that it will be dust and vermin proof IP 54 in epoxy powder coated copper construction rated for 45 degrees C ambient temperature . The Rising Mains should be built in convenient sections complete with fire proof barriers, thrust pads, expansion joints at intervals and straps for fixing from ceiling including mounting arrangement duly marked with the Current carrying capacity. The Rising Mains should be CPRI tested for 25 KA for 1 sec.
(d) Edgewise Hanger ( 800 A/50 KA.)
(e) End Cover ( 800 A/50 KA.)
(f) Edgewise Hanger ( 250 A/50 KA.)
(g) End Cover ( 250 A/50 KA.)
(h) Edgewise Hanger ( 200 A/50 KA.)
(j) End Cover ( 200 A/50 KA.)
630 A Tap off complete as required. The tap off shall be suitable for termination of required XLPE, Aluminium conductor armoured cable including required gland plate. Also provide 315 A TP MCCB of 25 KA service breaking capacity with heavy duty solid neutral link in the Tap off box.
315 A Tap off complete as required. The tap off shall be suitable for termination of required XLPE, Aluminium conductor armoured cable including required gland plate. Also provide 315 A TP MCCB of 25 KA service breaking capacity with heavy duty solid neutral link in the Tap off box.
250 A Tap off complete as required. The tap off shall be suitable for termination of required XLPE, Aluminium conductor armoured cable including required gland plate. Also provide 250 A TP MCCB of 25 KA service breaking capacity with heavy duty solid neutral link in the Tap off box.
63 A Tap off complete as required. The tap off shall be suitable for termination of required XLPE, Aluminium conductor armoured cable including required gland plate. Also provide 63 A TP MCCB of 25 KA service breaking capacity with heavy duty solid neutral link in the Tap off box.
40 A Tap off complete as required. The tap off shall be suitable for termination of required XLPE, Al conductor armoured cable including required gland plate. Also provide 40 A TP MCCB of 25 KA service breaking capacity with heavy duty solid neutral link in the Tap off box.
25 A Tap off complete as required. The tap off shall be suitable for termination of required XLPE, Al conductor armoured cable including required gland plate. Also provide 25 A TP MCCB of 25 KA service breaking capacity with heavy duty solid neutral link in the Tap off box.
EARTHING SYSTEM : Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 25x4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 (SSR Part-I) connected to earthing test point all as specified or indicated including testing on completion. Note: GI Earth strip upto 7.5M shall be deemed to be included in the unit rate quoted. The GI Earth strip beyond 7.5M shall be measured and paid separately under relevant item in this schedule (BOQ).
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 (SSR Part-I) connected to earthing test point all as specified or indicated including testing on completion. Note: GI Earth strip upto 7.5M shall be deemed to be included in the unit rate quoted. The GI Earth strip beyond 7.5M shall be measured and paid separately under relevant item in this schedule (BOQ).
Earthing complete with galvanised steel pipe electrode, 40mm bore,medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of galvanised iron 32×6mm strip as eartlung lead or steel wire including adequate quantity of charcol dust & common salt as shown in Plate No. 2 (SSR Part-I) to the earthing test point all as specified and indicated including testing on completion.
Advance encapsulated compound based CPRI tested Maintenance free, pipe-in-pipe technology upgraded (Zinc & Alloy Coated), ZINC COATED (80-100), Microns with pure Zinc (99.9%) & Alloy Coating (200-250) microns. Earthing system confirming to IS 3034. The outer and inner pipe should be 41.9mm dia ,26.4 mm, 2mtrs Length, Zinc coated with additional special alloy coating 300 mm on the topside for additional protection of the terminal. The annular space between the pipes being filled up with COMPACT FILL (CF) (Crystaline Conductive Compound). The COMPACT FILL (CF) mixture which is machine pressed in the pipes should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity. The job includes digging the pits and refilling the same by Electrodite/Conductolite back fill compound (Ground Enhancer), the BFC should be eco friendly it should not contain environmentally hazardous material/metal having ROHS Certification from NABL accredited lab. The earth pit should be provided with a FRP earth pit cover for protection and safeguard of terminals. In areas where soil condition is bad, good earth is to be arranged to fill the excavated pits by mixing the same BFC 2 bags (as per soil condition) extra per pit/unit. The material should have good electrical conductivity & anti corrosion property in wide range of soil conditions complete work, must be executed all as per manufacturer’s instruction (All the above given dimensions may vary ±1 MM) Note: The quantity of BFC * Electrodite shall be increased according to soil condition and to achieve the earth value less then 1Ω
CUTTING DOWN TREES
Felling of trees including grubbing up tree trunk and cutting of trunk portion protruding over ground, and cutting branches, digging out roots, filling holes and leveling off ground , stacking of serviceable material and removing of unserviceable material out side MoD land / Naval Dockyard area complete all as specified and directed of following girth of trees:
Girth of Tree Exc.30 cm and n exc. 100 cm
Girth of Tree Exc. 100 cm and n exc. 150 cm
Girth of Tree Exc.150 cm and n exc. 200 cm
Girth of Tree Exc. 250 cm and n exc. 300 cm
Girth of Tree Exc. 300 cm and n exc. 350 cm
Girth of Tree Exc. 1300 cm and n exc. 1400 cm
PILE FOUNDATION
RMC M-40 concrete as per IS-456-2000 in piles in any length /size including casting & knocking down waste concrete complete all as specified and shown on drawings. RCC shall be measured and paid from cut off level & rates shall be inclusive of cutting & knocking of RCC waste from cut off level.
Boring for bored cast in situ pile through soft /loose soil, stiff clay, soft disintegrated rock or any other strata (except hard rock strata) using DMC (Direct Mud Control) method or rotrary rig or any other method and getting out & disposal of spoil to a place outside of MoD land for following sizes:-
(a) 600mm dia piles
(b) 800mm dia piles
(c) 1000mm dia piles
Boring for bored cast in situ pile through hard rock strata using DMC (Direct Mud Control) method or rotrary rig or any other method and getting out & disposal of spoil to a place outside of MoD land for following sizes of pile:-
(a) 600mm dia piles
(b) 800mm dia piles
(c) 1000mm dia piles
Conducting non destruction pile integrity test using low strain method on cast in situ piles including mobilization of equipment & de-mobilization after completion of testing data analysis & submission of report as per IS-14893 of 2001 for pile of following sizes all as directed.
(a) 600mm dia piles
(b) 800mm dia piles
(c) 1000mm dia piles
Conducting Lateral Load tests (test load up to 40T) on bored cast in situ piles of dia between 450 & 900 mm diameter by prolliding Hydraulic Jack, Manual Pump, Dial Gauges including data anaylsis and submission of report all as directed.
Initial load testing dynamic testing (High Strain Dynamic) on piles 600mm dia all as per IS-2911, Part-IV including bringing on site all equipment required and removal from the site after testing is completed complete all as specified and as directed.
Initial load testing dynamic testing (High Strain Dynamic) on piles 800mm dia all as per IS-2911, Part-IV including bringing on site all equipment required and removal from the site after testing is completed, complete all as specified and as directed.
Initial load testing dynamic testing (High Strain Dynamic) on piles 1000mm dia all as per IS-2911, Part-IV including bringing on site all equipment required and removal from the site after testing is completed, complete all as specified and as directed.
Routine load testing dynamic testing (High Strain Dynamic) on piles 600mm dia all as per IS-2911, Part-IV including bringing on site all equipment required and removal from the site after testing is completed complete all as specified and as directed.
Routine load testing dynamic testing (High Strain Dynamic) on piles 800mm dia all as per IS-2911, Part-IV including bringing on site all equipment required and removal from the site after testing is completed complete all as specified and as directed.
FIRE FIGHTING: GM fire brigade suction hose coupling (draw-out connection) with nut for female coupling as per IS standards complete with 100mm dia GI suction pipe and 100mm dia foot valve to be connected to static tank complete all as specified and directed.
MS Angle iron (40mmx40mmx5mm) door frame and S.S. Sheet (2mm thick) cum glass shutter of size 2.1m x 0.9m (N.S) with 25mm x 25mm x 3mm angle frame all around and stiffened in between i/c hinges, handle, locking arrangement, painting with approved synthetic enamel paint i/c sign writing on glass at internal hydrant including providing & fixing S.S. Sheet 2mm thick on remaining portion above door to close opening i/c painting etc. as required. Glass shall be 6mm thick . The cabinet shall be suitable to accommodate 2 Nos 15mtr long Hose pipe & 2 Nos branch pipe nozzle. It shall be mounted on raised Brick platform complete as required complete all as directed. Note: Cost shall be inclusive of providing break glass box containing key for the cabinet along with hammer.
Fire Extinguisher, ISI Marked (IS:2878) Carbon-di-oxide type capacity 4.5Kg. Flat base including valve, discharge hose of not less than 10mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and GI wall suspension bracket of suitable size all as directed.
ABC (Powder Type) Fire Extinguisher 6KG. In HP Mild Steel Cylinders ISI marked TAC approved, fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen and confoming to IS:1349-1993 complete in all respects including GI wall suspension bracket of suitable size all as directed.
CO2 type fire extinguishers consisting of welded M.S cylindrical body automatic modular CO2 type extinguisher actuated through a sprinkler head mounted on the extinguisher body finished externally with red enamel paint with trolly mounted complete with initial charge (Capacity 22.5Kg) all as directed.
CO2 type fire extinguishers consisting of welded M.S cylindrical body automatic modular DCP type extinguisher actuated through a sprinkler head mounted on the extinguisher body finished externally with epoxy powder coated with trolly mounted complete with initial charge (Capacity 25Kg) all as directed.
15mm dia sprinkler head with standard response Quartzoid Bulb operate at 57 degree C complete with all accessories as required , Upright/ Pendent type in chrome finish (Standard Coverage) all as directed.
Brass quartzoid sprinklers of 15mm dia size, suitable for sustaining the seat & water hammer effect, sidewell extended coverage sprinkler quick response type (57 deg.C) as per specified and as directed.
SOOD ASSOCIATES PVT LTD
UBC Engineers Pvt Ltd
Hariom Projects Pvt Ltd