Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAdmitted-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L1 | Admitted-Finance | |
| 2 | L2₹35.2 L+₹2.5 L (7.60%)Admitted-Finance R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | L2 | Admitted-Finance | |
| 3 | L3₹35.9 L+₹3.2 L (9.67%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹38.2 L+₹5.5 L (16.7%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹40.5 L+₹7.8 L (23.7%)Admitted-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | K S BUILDERS L5 | EAST URBAN ENGINEERING L4 | slathia construction works L2 | MOHAN LAL AND SONS L8 | shivom builders L9 | TRINETAR RC ENTERPRISES L11 | Prakash Trading Corporation L6 | PREM NATH KHAJURIA AND SONS L3 | ANIKET TRADERS L1 | jaima electricals L7 | A K ENTERPRISES ENGINEER CONTRACTOR AND GEN ORDER SUPPLIERS L10 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of unserviceable concerete/steel tubular pole any size upto 9 mtr long including breaking up PCC and making good disturbed surface and removing materials from site of work complete all as specified and directed by Engineer-in-Charge. | 15 | Each | 206 ₹3,090 | 100 ₹1,500 | 200 ₹3,000 | 10 ₹150 Lowest | 2,450 ₹36,750 | 2,200 ₹33,000 | 1,000 ₹15,000 | 200 ₹3,000 | 500 ₹7,500 | 2,500 ₹37,500 | 3,200 ₹48,000 |
| 2.00 | Supply and fixing of steel tubular swaged poles with two coat of aluminium paint ovar a coat of red oxide zinc chrome prime in externally exposed to view portion and black bituminous painting to intenal surface and portion embeded in concrete incl making five alternative strips 30 cm wide in different colour above ground level or plinth level incl marking of MES pole No in black paint complete with cast iron base plate, final tapper plug, bolts, nuts and screws as specified type 410 SP-31 (9.00 mtr long) and complete all as specified and directed by Engineer-in-Charge. | 15 | Each | 15,696 ₹2,35,440 | 25,500 ₹3,82,500 | 15,000 ₹2,25,000 | 17,000 ₹2,55,000 | 20,000 ₹3,00,000 | 18,000 ₹2,70,000 | 18,000 ₹2,70,000 | 14,990 ₹2,24,850 | 17,500 ₹2,62,500 | 10,000 ₹1,50,000 Lowest | 11,000 ₹1,65,000 |
| 3.00 | M & L for PCC 1:4:8, type D-2, (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-Charge. | 0.85 | Cum | 2,606 ₹2,215.1 | 4,200 ₹3,570 | 2,500 ₹2,125 | 1,400 ₹1,190 Lowest | 7,215 ₹6,132.75 | 4,500 ₹3,825 | 2,300 ₹1,955 | 3,800 ₹3,230 | 3,000 ₹2,550 | 3,000 ₹2,550 | 5,200 ₹4,420 |
| 4.00 | M & L for PCC 1:3:6, type C-2, (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed by Engineer-in-Charge. | 8 | Cum | 2,906 ₹23,248 | 4,800 ₹38,400 | 2,500 ₹20,000 | 1,800 ₹14,400 Lowest | 7,700 ₹61,600 | 4,200 ₹33,600 | 2,200 ₹17,600 | 3,900 ₹31,200 | 3,500 ₹28,000 | 3,500 ₹28,000 | 5,500 ₹44,000 |
| 5.00 | M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed by Engineer-in-Charge. | 1.25 | Cum | 3,406 ₹4,257.5 | 5,600 ₹7,000 | 3,000 ₹3,750 | 2,000 ₹2,500 Lowest | 9,450 ₹11,812.5 | 5,800 ₹7,250 | 2,100 ₹2,625 | 4,000 ₹5,000 | 4,000 ₹5,000 | 4,500 ₹5,625 | 8,150 ₹10,187.5 |
| 6.00 | Supply and fixing LED street light fitting of capacity 72 watts ,230 volts AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optic and equipped with IP 66 protection, with impact and corrsion resistant complete with drivers and as per national lighting code by using each LED>1W and <3 W, LED Chip efficiency>=135 Lumens/Watt, CRI>70, CCT 5000K to 6500 K with LED Lifespan at 70% of light output>50000 hours. The driver should be 140 V to 270 V universal driver with built in surge protection >5 KV, 50 Hz, +/-3%, pf>0.95, THD<10% with system efficiency must be >85 lumens/Watt and power efficiency >=90% and overall, Driver and luminaire shall comply LM-79/IS: 16106 and all accessories and making all necessary connection including taking out of old unserviceable one, complete all as specified and directed by Engineer-in-Charge.. | 60 | Each | 2,886 ₹1,73,160 | 3,050.3 ₹1,83,018 | 3,200 ₹1,92,000 | 2,800 ₹1,68,000 | 5,100 ₹3,06,000 | 3,200 ₹1,92,000 | 4,700 ₹2,82,000 | 3,250 ₹1,95,000 | 2,290 ₹1,37,400 Lowest | 4,200 ₹2,52,000 | 4,500 ₹2,70,000 |
| 7.00 | Supply and fixing 150 watt energy , saving environmental friendly, long life exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural features or retail spaces, and as per national lighting code by using each LED>1W and <3 W, LED Chip efficiency>=135 Lumens/Watt, CRI>70, CCT 5000K to 6500 K with LED Lifespan at 70% of light output>50000 hours. The driver should be 140 V to 270 V universal driver with built in surge protection >5 KV, 50 Hz, +/-3%, pf>0.95, THD<10% with system efficiency must be >85 lumens/Watt and power efficiency >=90% and overall, Driver and luminaire shall comply LM-79/IS: 16106 including taking out of old unserviceable one, complete all as specified and directed by Engineer-in-Charge.. | 10 | Each | 5,266 ₹52,660 | 5,711.2 ₹57,112 | 5,000 ₹50,000 | 6,500 ₹65,000 | 8,000 ₹80,000 | 3,800 ₹38,000 | 6,500 ₹65,000 | 4,850 ₹48,500 | 3,800 ₹38,000 | 2,500 ₹25,000 | 2,250 ₹22,500 Lowest |
| 8.00 | S & F GI tubing medium grade 40 mm dia in protection of cable of difference dia laid in trench under road/foot path or fixed on pole with necessary clamps with bolts etc complete all as specified and directed by Engineer-in-Charge. | 50 | RM | 406 ₹20,300 | 344 ₹17,200 | 200 ₹10,000 | 180 ₹9,000 Lowest | 495 ₹24,750 | 270 ₹13,500 | 600 ₹30,000 | 275 ₹13,750 | 400 ₹20,000 | 230 ₹11,500 | 230 ₹11,500 |
| 9.00 | S & F GI tubing medium grade 50 mm dia in protection of cable of difference dia laid in trench under road/foot path or fixed on pole with necessary clamps with bolts etc complete all as specified and directed by Engineer-in-Charge. | 20 | RM | 456 ₹9,120 | 487 ₹9,740 | 250 ₹5,000 | 200 ₹4,000 Lowest | 650 ₹13,000 | 330 ₹6,600 | 700 ₹14,000 | 350 ₹7,000 | 500 ₹10,000 | 280 ₹5,600 | 290 ₹5,800 |
| 10.00 | Taking up old serviceable/unserviceable UG cable of size 16 Sqmm 4 core to 35 Sqmm 3.5 core from trench for replacement , repair and re-laying or re-routing. Earth work shall be measured and paid separately under appropriate items of Sch-'A'), complete all as specified and directed by Engineer-in-Charge. | 2,400 | RM | 16 ₹38,400 | 12 ₹28,800 | 1 ₹2,400 Lowest | 1 ₹2,400 Lowest | 30 ₹72,000 | 10 ₹24,000 | 50 ₹1,20,000 | 2 ₹4,800 | 2 ₹4,800 | 10 ₹24,000 | 6 ₹14,400 |
Tender Value
₹48.3 L
EMD Value
₹96,530
Closing Date
28 Jul 2026, 6:00 pmClosed
GE (Utilities) Udhampur
GE (Utilities) Udhampur PO-Garhi Piin-182121
Special repair/replacement to street light junction boxed, timer switches, pole and LED light at 1 FOD Adm area under GE (Utilities) Udhampur
2026_MES_777067_1
GE/U-77/2026-27
Open Tender
Miscellaneous Works
Item Rate
90 days
GE (Utilities) Udhampur
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampur
₹96,530
6 Aug 2026
7 Jul 2026
30 Jul 2026
7 Jul 2026
28 Jul 2026
21 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling of unserviceable concerete/steel tubular pole any size upto 9 mtr long including breaking up PCC and making good disturbed surface and removing materials from site of work complete all as specified and directed by Engineer-in-Charge. | 15 | Each | - | - |
| 2 | Supply and fixing of steel tubular swaged poles with two coat of aluminium paint ovar a coat of red oxide zinc chrome prime in externally exposed to view portion and black bituminous painting to intenal surface and portion embeded in concrete incl making five alternative strips 30 cm wide in different colour above ground level or plinth level incl marking of MES pole No in black paint complete with cast iron base plate, final tapper plug, bolts, nuts and screws as specified type 410 SP-31 (9.00 mtr long) and complete all as specified and directed by Engineer-in-Charge. | 15 | Each | - | - |
| 3 | M & L for PCC 1:4:8, type D-2, (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-Charge. | 0.85 | Cum | - | - |
| 4 | M & L for PCC 1:3:6, type C-2, (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed by Engineer-in-Charge. | 8 | Cum | - | - |
| 5 | M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed by Engineer-in-Charge. | 1.25 | Cum | - | - |
| 6 | Supply and fixing LED street light fitting of capacity 72 watts ,230 volts AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optic and equipped with IP 66 protection, with impact and corrsion resistant complete with drivers and as per national lighting code by using each LED>1W and <3 W, LED Chip efficiency>=135 Lumens/Watt, CRI>70, CCT 5000K to 6500 K with LED Lifespan at 70% of light output>50000 hours. The driver should be 140 V to 270 V universal driver with built in surge protection >5 KV, 50 Hz, +/-3%, pf>0.95, THD<10% with system efficiency must be >85 lumens/Watt and power efficiency >=90% and overall, Driver and luminaire shall comply LM-79/IS: 16106 and all accessories and making all necessary connection including taking out of old unserviceable one, complete all as specified and directed by Engineer-in-Charge.. | 60 | Each | - | - |
| 7 | Supply and fixing 150 watt energy , saving environmental friendly, long life exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural features or retail spaces, and as per national lighting code by using each LED>1W and <3 W, LED Chip efficiency>=135 Lumens/Watt, CRI>70, CCT 5000K to 6500 K with LED Lifespan at 70% of light output>50000 hours. The driver should be 140 V to 270 V universal driver with built in surge protection >5 KV, 50 Hz, +/-3%, pf>0.95, THD<10% with system efficiency must be >85 lumens/Watt and power efficiency >=90% and overall, Driver and luminaire shall comply LM-79/IS: 16106 including taking out of old unserviceable one, complete all as specified and directed by Engineer-in-Charge.. | 10 | Each | - | - |
| 8 | S & F GI tubing medium grade 40 mm dia in protection of cable of difference dia laid in trench under road/foot path or fixed on pole with necessary clamps with bolts etc complete all as specified and directed by Engineer-in-Charge. | 50 | RM | - | - |
| 9 | S & F GI tubing medium grade 50 mm dia in protection of cable of difference dia laid in trench under road/foot path or fixed on pole with necessary clamps with bolts etc complete all as specified and directed by Engineer-in-Charge. | 20 | RM | - | - |
| 10 | Taking up old serviceable/unserviceable UG cable of size 16 Sqmm 4 core to 35 Sqmm 3.5 core from trench for replacement , repair and re-laying or re-routing. Earth work shall be measured and paid separately under appropriate items of Sch-'A'), complete all as specified and directed by Engineer-in-Charge. | 2,400 | RM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
BOQ_870255.xls
BOQ • 11.73 MB
TENDER77.pdf
Tender Documents • 1.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .