Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹48.5 L+₹1.8 L (3.85%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹49.0 L+₹2.3 L (4.86%)Rejected-Finance 40 6 UKHARA PO PRATAP PURA AGRA UP 282001 | AGRA | AGRA | UP | 282001 | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹49.5 L+₹2.8 L (5.89%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹49.9 L+₹3.2 L (6.87%)Rejected-Finance 00 BEHIND CHARCH NAYAGOWAN LAKHERA BEHIND RAMA MANI DAIRY KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
20 Jul 2024, 6:00 pmClosed
GE (East) Agra
Garrison Engineer (East) Agra, Military Engineer Services, Gwalior House, 62 Taj Road Agra Cantt-282001
REPAIR / MAINT TO DETORIATED CHAJJA, COLUMN, BALCONY, FACIA / CANOPY, WALL / CEILING PLASTER WITH CHEMICAL AND MODERN TECHNOLOGY AT OTM / MD ACCN UNDER AGE B/R-I AND II OF GE (EAST) AGRA
2024_MES_662849_1
9680/E8
Open Tender
Civil Works
Item Rate
240 days
AGRA (UP)
Please refer tender documents
10 documents required · 10 mandatory
₹500
GE (East) Agra
₹99,800
Yes
7 Oct 2024
29 Jun 2024
27 Jul 2024
29 Jun 2024
20 Jul 2024
13 Jul 2024
Amount
M&L for applying chemical compound with dispersing agents Removing (and not damaging the beneath brick or RCC surface) old existing unserviceable concrete, cement plaster, loose / unsound weaken cement of any description and in any position from existing external / internal surfaces of walls, or any surface average depth 5-25mm (Approx height upto 9 m from natural ground level) with concrete removing agent(except for zinc and galvanised metal) and clean the treated surface immediately after removal treatment, and removal up to the approval municipal dumping grounds specified by the local bodies outside MOD land including cutting of all edges, making square shoulders of the cavities, roughening the smooth surfaces, scrapping out / removing corrosion all loose / scale/ rust etc from the visible unplastered surface complete all as specified and directed. Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
Material & labour for cleaning the surface of the stone/concrete/brick with mechanical grinder and specialized water misting techniques applying water jet using a fine nozzle sprinkling system calibrated to spray a fine mist along the stone/concrete surface complete and removing all complete all as specified and directed by Engineer in charge. And applying one coat of sealer with capacity of Drastic reduction in water absorption - ASTM C642-97 With Improved resistance to chloride penetration in concrete surface (RCPT) as per ASTM C1202. And Improved abrasion resistance of surface when tested as per ASTM C779 and low alkaline silicate based, first reacting with other free oxides and hydroxides like calcium hydroxide (free lime) inside the concrete to form corresponding silicates, which are stronger molecules. Total Solids Content 29-30% approx. Specific Gravity at 25°C 1.25 +/- 0.02 Ph Alkaline VOC Content Nil This sealer gels in the empty pores which is insolble silica deposits. Finally forms a microscopic siliceous layers on the surface which results in strong ceramic coating, firmly bonded to the surface by strong silanol bonds. This is stable against UV and high temperature Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
M&L for Corrosion protection of unexposed old reinforcement on non-spalled concrete by Insertion of sustained release Corrosion inhibiting caplets, which protect both anodic & cathodic sites and reduces Corrosion potential Ecorr by minimum 80 mV in conductive medium, by drilling 20-22 mm dia holes into the concrete at a depth of 30-40 mm and inserts to be filled by epoxy sealant . Caplets shall inhibit corrosion inhibition efficiency of 98% (when added 0.03 % by weight) against control sample evaluated by Tafel polarization method. Depth of penetration for effective corrosion protection shall be 120 mm & film formation of 20 Microns as evaluated by CSIR-CECRI Karaikudi. Spacing of Caplets shall be 750 mm in horizontal or vertical direction in RCC structure etc all as specified and directed. Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
M&L for Cleaning all existing reinforcement bars with wire brush/rotary wire brush to make entire surface of bars free from loose torn metallic parts, loose material, dirt etc. and M&L for applying alkaline Antioxydizing agent on the existing rebars and allowing it to react with damaged metal and form a corrosion resistant, insoluble protective layer, as per manufacturer's instructions, including necessary scaffolding, props etc. complete all as specified and as directed. (Mode of measurement: per sqm of breaking area of concrete.) Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
M&L for Providing and applying Zinc rich epoxy anti-corrosive protective coating for reinforcement bars as corrosion protection system in 2 coats to the entire circumference surface of bars as specified and directed by Engr-in-charge. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/sqmm according to ASTM C 882-78 (Mode of measurement: per sqm of application area of concrete.) complete all as specified and as directed. The rate shall include cost of scaffolding necessary for the work etc. complete all as specified and as directed. Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
M&L for MS TMT bars 10 mm dia and over as in reinforcement cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends & bending with and including MS annealed wire not less than 0.9 mm dia etc. complete all as specified and directed. Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
M&L for Providing and applying Bi-polar migratory corrosion inhibitor on concrete surface by spraying at 4 sqm/ltr and wiping the surface with moist cloth after few minutes to remove any residual material which has not penetrated, including all necessary surface preparation, necessary scaffolding, props, etc as per requirement, complete all as specified and directed. Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
M&L providing and filling three components compound (A) graded filler (B) E-Resins (C) thixotropic agents with adjustable consistency by varying the filler component. Chemicals having the density of 1.64 -1.68gm/cc.for brick walls/floor/ columns cracks after opening up in “V” groove manner covering the area of 30mm from central line of crack with the depth of 10 mm complete all as specified and as directed. Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
M&L for Providing, mixing & applying two component epoxy resin concrete bonding coat on prepared RCC surfaces prior to application of any type of repair mortar or microconcrete as per manufacturer's specification including cleaning of surface to remove all dirt, dust or any other impurities, etc. including necessary scaffolding work, all complete as specified and directed. The product should comply with ASTM C 881 Type II Grade 2 Class B+C complete all as specified and as directed. Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
M&L for Drilling Holes of 12mm dia upto 100mm deep in structural members at the interval of 300mm in staggered manner or along the crack line in RCC structural member including cleaning of the holes by air blower and M&L for inserting 12mm dia NRV nozzles compatible with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix the nozzles inside the hole by applying thixotropic epoxy adhesive to ensure complete sealing and allow curing the system for minimum of 8 hrs before grouting: Cut and remove nozzle projections, excess putty, if any, over concrete element by grinding, levelling and finishing the external surface, after completion of the work, etc. complete all as specified and directed. The rate shall include scaffolding and other necessary works. Note -: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
M&L for Providing and injecting two part, low viscous, high strength epoxy resin based moisture insensitive liquid using pressure injector with accessories till nozzle refuses to accept the grout including mixing of grout material components in adequate proportions as per manufacturer's instructions by weight batching and grouting the mixed material into the structural member by grouting gun, maintaining desired pressure in the gun by air compressor and maintaining pressure at exit about 2 to 3 kg/cm2 by monitoring pressure guage at exit. The mixed grout should have following properties:- (i) Mixed Density 1.1 kg/I (at + 27°C); Viscosity ~ 250 mPas at + 30 °C and should comply according to ASTM C 881, Type II and IV, Grade-1, class E+F (i° Compressive strength >+ 70 N/ sqmm (7 days) according to ASTM C 579; Tensile Strength ~ 50 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); Tensile Modulus ~2000 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); (i) Bond Strength ~ 10.8 N/sqmm (failure in concrete) after 14 days at +30oC cure; Flexural strength ~ 50 N/sqmm according to ISO 178. (iv) Seal the nozzle with thixotropic epoxy adhesive after the refusal of grout material from the nozzle . Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
M&L for mixing mechanically PP fibre of 12 mm length with Anti-crack strength in red mix repair mortar with suitable care to ensure dispersion of fibres conforming to ASTM C 1116/C, 1116M-10a 4.1.3 type3 & BS EN14889-2.2006 and providing 20 mm thick one component chloride free thixotropic fibre reinforced polymer modified repair mortar at external brick wall with ASTM C 109 with flexural strength ASTM C 348 @ 7 days meeting 7N/mm2 and tensile strength @ 7 days (ASTM C 307) >3 N/mm2 in cement mortar in the ratio 1:4 mixed with styrene butadiene polymerized cement mortar modifier or AR for bonding with Cement mortar specially adhered to BS 6319 having specific gravity of 1.025 to 1.04, minimum 43% solid contents) not less than 2% by weight of cement and as per manufacturer’s Instructions. For external columns or any brick or stone wall surface etc. Note-: This item shall be executed by authorized agency, Contractor shall submit the MOU with authorized applicator of manufacturer.
M&L for mixing mechanically PP fibre of 24 mm length with Anti-crack strength with Rheoplastic non shrink, corrosion resistant, High strength MICROCONCRETE having compressive strength as Bs 4551-80 by adding 12mm graded aggregate or in combination with 1:4 mortar for 25 mm jacketing ensuring strength (ASTM C 109)-35 Mpa @ 28 days, Tensile strength 2.0N/mm2 @ 28 days (ASTM C 348)- 4 Mpa @ 28 days, Flextural strength 10N/mm2 (ASTM C 348)-11 Mpa @ 28 days, Young's modulus -27 KN/sqm (ASTM D469), Expansion charactristics (ASTM C 827-1987) Unrestrained expansion upto 4% pressure to restrain plastic Expansion -Approx. 0.004 N/sqm pouring of micro concrete into the formwork of columns using suitable arrangement or required using pumping device for uniform flow of micro concrete. The side shuttering can be removed after 3 days, and the bottom shuttering after 7 days, ensuring proper bond between the micro concrete and existing brick columns etc complete all as specified and directed. Note-: This item shall be executed by authorized agency, Contractor shall submit the MOU with authorized applicator of manufacturer.
M&L for mixing mechanically PP fibre of 12 mm length with Anti-crack strength in redymix repair mortar with suitable care to ensure dispersion of fibres conforming to ASTM C 1116/C, 1116M-10a 4.1.3 type3 & BS EN14889-2.2006 and providing 15 mm thick one component chloride free thixotropic fibre reinforced polymer modified repair mortar at external brick wall with ASTM C 109 with flexural strength ASTM C 348 @ 7 days meeting 7N/mm2 and tensile strength @ 7 days (ASTM C 307) >3 N/mm2 in cement mortar in the ratio 1:4 mixed with styrene butydiene polymerized cement mortar modifier or AR for bonding with cementious mortar specially adhered to BS 6319 having specific gravity of 1.025 to 1.04, minimum 43% solid contents) not less than 2% by weight of cement and as per manufacturer’s Instructions. For external columns or any brick or stone wall surface etc. Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
M&L for Fiber wrapping: Design, fabrication and supply of FRP system for strengthening of structural elements comprising of FRP sheet and compatible saturant, by dry/wet layup system including surface preparation: Grinding, moulding concrete substrate. Cleaning it with wire brush, removing oil, laitance if present. Rounding off sharp edges to minimum 25mm radius. Proofing: Applying epoxy primer on prepared substrate, filling holes and uneven surfaces with thixotropic putty, etc. complete. Wrapping: Wrapping the fibre sheet to structural element at desired orientation with application of compatible epoxy saturant using tamping roller to avoid any air voids. Sand pasting: Applying second coat of saturant, rectify air voids if any; paste the river sand on it to make surface rough to take further finishes. (Mode of measurement: Fiber area or application, not surface area of Rec member). Rate to include scaffolding as per site requirement. CFRP 200 GSM. Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
M &L for curing of the surface using wax based Concrete curing compound CC 75 curing efficiency; CC 75 complies with the internationally recognized ASTM C309-90 standards incuding all tools and tackles. Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
M&L for Providing and applying one coat of Solvent based compound having Electrochemical impedance of 107 Ω and achieving dry film thickness of minimum 80 microns per coat with UV condensation of Min 100 Hrs. Elastomeric, Anti carbonation, Anti corrosive, UV resistant , Pure Aliphatic Acrylate System- on the exterior faces of Buildings Protection against ION penetration, carbonation,UV radiations and wethering effect conforming to ASTM D 4541-02 a primer coat using brush or spray after complete cleaning & removal of oil, grease or loose particles from the surface etc. complete all as specified and directed. Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
M & L for new or old surfaces of exterior wall decorating and water proofing treatment to wall surface by wire brushing in order to remove dust, dirt, loose particles, laitance. Thereafter wash the surface with clan water & allow to dry. Fill visible cracks/ joints by chemistic crack seal caulking compound & allow to dry for 24 hours. Apply a primer coat of chemistic prime M Seal (water base primer) and allow to dry for 6 hours. Thereafter apply 02 coats of weathercoat glow (WB high build anti carbonation coating cum waterproofing) & shade by brush at the interval of 08 hours between the coat and allow to dry to match the existing shade including necessary scaffolding for any height, covering etc complete all as per specified and directed. Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
M&L Formwork to sides of rough finish surfaces of concrete pillars, posts, struts, piers, columns, and stanchions fair finished surfaces of concrete etc all as specified and directed. Note-: This item shall be executed by authorised agency, Contractor shall submit the MOU with authorised applicator of manufacturer.
Note for Item No. 1 to 19 :- (a) The work for item No. 1 to 19 shall be executed directly by company or their authorized applicator. Applicator shall be authorized in writing by company and guarantee / responsibility of work executed shall be owned by company and contractor in writing (b) Quoted rate sahll be inclusive of material and labour tools and plants, scaffolding and working upto 15 mtr height ( c) Adoption of necessary safety arrangement like safety belts, ropes, helmets, netting etc which are required for safety of working at height etc which are required for safety of worker at height'll be mandatary and deemed to be inclusive on quoted rates. (d) The quantity of chemical to be required as per BOQ to carried out work has to be submitted by the authorize agent by the manufacturer of chemical duly signed by the contractor /applicant /manufacturer to the department.
Balaji Associates (BID ID -3064580)
Attar Singh and Sons (BID ID -3066009)
M/S RADHEY GOVIND ENTERPRISES (BID ID -3067037)
3Krishna Enterprises (BID ID -3066992)
VARDMAN ENTERPRISES (BID ID -3066924)
M/s Laxmi Associate (BID ID -3067714)
VASUNDHARA AND COMPANY (BID ID -3067757)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .