Loading…
Loading…
Tender Value
₹5.4 Cr
EMD Value
₹10.9 L
Closing Date
21 Sept 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
S AND T
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or " V" whichever is less; where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any of the following during last 07(seven) years, ending last day of month previous to the one in which tender is invited: Three similar works costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. Similar Nature of Work for this tender is " Any work of supply and installation of train indication board / coach guidance system/PA system / Clock/IPIS/Touch Screen enquiry system/Display board."
2 conditions
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Two years warranty or latest guideline as per RDSO / Railway Board whichever is more. The system will be compatible with the existing system installed in that station.
Schedule A-Provision of PF Sheds at Non Sub-urban stations at TIT, KAN, JTL, BPS, NRX, GKH, PCQ, BDH, BHP, PNE, KPLE, AMP, BSLE, SNT, GHLE, MLV in HWH division, Schedule-B -Provision of PF Sheds at Non Sub-urban stations at 26 stations in Howrah division,Schedule C-Provision of PF-sheds on Sub-urban stations at BZL, DKAE, GBRA, JOX, BPAE, BRPA, BLAE, MBE, KQU, MDSE,CDAE,PBZ, BMAE, SHBC, HIH in HWH division. Schedule D-Provision of PF-sheds at ADST, MUG, TLO, KHN, PDA, SLG,BOI, BCGM, DBP, NMF, BGF, RSLR, HYG & GFAE stations in the jurisdiction of Sr. DEN/1/HWH.Schedule E-Provision of PF Sheds at GRAE, JPQ, JRAE, MSAE, NBAE, CHC, PRAE, SKG & GRP stations in the section of Sr. DEN/2/HWH.
SDSTE-ETN-PF-SHED-26STN~ER
SDSTE-ETN-PF-SHED-26STN
Open
Works - General
9 Months
Howrah, West Bengal
₹0
₹10.9 L
21 Sept 2026
28 Aug 2026
7 Sept 2026
258 items across 5 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,47,15,778.46 | ||
| — | — | — | Above/ 47593.20 Below/P | ||
| "Installation, testing and commissioning of Coach Indication Display board ( Double Face ) (including supply, fabrication and erection of pole, angles, fastening and rain hood after shifting from existing location if required ) as per site requirement Note : This also includes intergration with the existing system as per site supervisor" | — | 8.00 | — | — | |
| — | — | — | Above/ 1631864.48 Below/P | ||
| Supply and installation of Singile line Double face train Arrival/Departure Platform Display Board"(a) Supply of Singile line Double face train Arrival/Departure Platform Display Board as per RDSO SPEC. No. RDSO/SPN/TC/108/2019, Ver 1.0 or LatestInspection: By RDSO.""(b) Installation of Singile line Double face train Arrival/Departure Platform Display Board as per RDSO SPEC. No. RDSO/SPN/TC/108/2019, Ver 1.0 or Latest (including shifting from existing location if required) Note : This also includes intergration with the existing system as per site supervisor" | — | 8.00 | — | — | |
| — | — | — | Above/ 370720.00 Below/P | ||
| "Supply, Installation, testing and Commissioning of Platform dual face, 4 digits, GPS synchronised digital clock as per RDSO spec. RDSO/SPN/TC/ 62 /2008 Rev. 3, Amdt- 1 and Amdt. -2 orlatest, with LED of Blue/Red/White colour and size approximately 762 x 381 x 228 mm It also includes all fitting arrangements. (Colour to be decided by Railways).Inspection: (i) RDSO/RITES if value of item in work morethan 5 lakhs (ii) Consignee if value of whole item in work less than 5 lakhs" | — | 8.00 | — | — | |
| — | — | — | Above/ 477760.00 Below/P | ||
| "Supply and laying of single mode 12 fibre armoured OFC cable, as per AnnexureInspection: (i) RDSO/RITES if value of item in work morethan 5 lakhs (ii) Consignee if value of whole item in work less than 5 lakhs" | — | 8000.00 | — | — | |
| — | — | — | Above/ 2021360.00 Below/P | ||
| Supply and laying of Power Cable 3 X 4 SQ. MM through HDPE pipe"(a) Supply of Power Cable 3 X 4 SQ. MM as per IS-694 . PVC insulated flexible 3 core x 4 sq. mm multistrand power cable provided for display boards shall conform to specification no IS694: 1990 reaffirmed 1995 or latest of reputed brand. as per AnnexureInspection: (i) RDSO/RITES if value of item in work morethan 5 lakhs (ii) Consignee if value of whole item in work less than 5 lakhs"(b) Laying of all types of cable through HDPE pipe | — | 8000.00 | — | — | |
| — | — | — | Above/ 808939.30 Below/P | ||
| Supply and laying of STP CAT-6 Cable"(a) Supply of STP CAT-6 Cable (305 meter Box). as per AnnexureInspection: (i) RDSO/RITES if value of item in work morethan 5 lakhs (ii) Consignee if value of whole item in work less than 5 lakhs""(b) Supply of 25 mm PVC conduit pipe as per ISI grade. as per AnnexureInspection: (i) RDSO/RITES if value of item in work morethan 5 lakhs (ii) Consignee if value of whole item in work less than 5 lakhs"(c ) Laying of CAT 6 Cable through PVC Conduit/ polythene pipe/ or as per site requirement. All fixing accessories shall be supplied by the contracrot and this also includes transportation of cable conduit to the site. | — | 7930.00 | — | — | |
| — | — | — | Above/ 442080.00 Below/P | ||
| Supply and Laying of LS cable through HDPE pipe "(a) Supply of LS cable. 2 Core 1.5 Sq.mm Steel Wire Armoured screened Anneled Tinned Copper (ATC) cable . Speaker External Cable, ISO Standard. as per AnnexureInspection: (i) RDSO/RITES if value of item in work morethan 5 lakhs (ii) Consignee if value of whole item in work less than 5 lakhs"(b ) Laying of all types of cable through HDPE pipe | — | 9600.00 | — | — | |
| — | — | — | Above/ 240960.00 Below/P | ||
| Supply and laying/fixing of Medium class GI pipes"(a) Supply of Medium class GI pipes 50 mm dia(3.6 mm thickness) as per IS 1239 ( Part 1 ) : 2004 for use in ASM room and at any other location as decided by Site Engineer. It includes supply of all material required for fixing arrangement. At the ends of GI pipe, flexible/corrugated HDPE pipe will be provided by contractor to protect cables from sharp edges and sudden bends.Inspection: Consignee""(b) Laying & Fixing of Medium class GI pipes 50/100 mm dia(4.5 mm thickness) as per IS 1239 ( Part 1 ) : 2004 with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. During Fixing of GI Pipe perforation needs to be done by Contractor as advised by Site Engineer. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work(if required) to protect the cables from sharp edges and sudden bends.Inspection: Consignee" | — | 480.00 | — | — | |
| — | — | — | Above/ 700808.00 Below/P | ||
| Supply and Laying of HDPE pipe duct, 40/33 mm in trenches and protective works"(a) Supply of 40 mm dia permanently lubricated HDPE telecom: ducts (with chord) as per RDSO SPEC.NO. RDSO/SPN/TC/45/2013 REVISION 2.0 with latest amendments or Latest in length of 1000 mtrs/roll For each km. Of HDPE duct following items are to be supplied (a) end plugs-2 nos. (b) cable sealing plugs - 2 nos. (c) plastic couplers slip fit/push fit type-2 nos. (d) end plugs to be provided along with drum 2 nos. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs or as per extant policy"(b) Laying of HDPE pipe duct, 40/33 mm in trenches and protective works including pulling of armoured OFC cable | — | 8.00 | — | — | |
| — | — | — | Above/ 40032.00 Below/P | ||
| "Digging of trench 1.2 Mtrs. deep from rail flange/ road leveland 0.3 Mtrs to 0.6 Mtrs wide and back filling after placing ofDWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe coveredseparately). The ballast disturbed be screened and dressed as required by Engineer-in- charge or his representatives androad tarred immediately. For track crossing, RDSO sketch No.SDO/CABLE LAYING/009 or latest and for Road Crossing,RDSO sketch No. SDO/CABLE LAYING/010 or latest are tobe followed." | — | 144.00 | — | — | |
| — | — | — | Above/ 1595200.00 Below/P | ||
| Cuting of the Platform surface (Tile/Slab/Mastic Pad/Concrete) as per requirement of the site and refilling/ reconditioning/ concreating/ repairing the platform after laying of GI Pipe/ HDPE Pipe/ Cable depth of cutting should not be less than 6" where possible. | — | 6400.00 | — | — | |
| — | — | — | Above/ 233382.24 Below/P | ||
| "Supply and installation of 1KVA Online UPS with thirty minute backup. as per AnnexureInspection: (i) RDSO/RITES if value of item in work morethan 5 lakhs (ii) Consignee if value of whole item in work less than 5 lakhs" | — | 18.00 | — | — | |
| — | — | — | Above/ 183856.32 Below/P | ||
| "Supply and Installation of Media converter as per AnnexureInspection: (i) RDSO/RITES if value of item in work morethan 5 lakhs (ii) Consignee if value of whole item in work less than 5 lakhs" | — | 16.00 | — | — | |
| — | — | — | Above/ 259863.36 Below/P | ||
| "Supply and Installation of 19"" rack mouted 24 port Fiber management Distribution system and termination of OFC and Splicing of all the Fibers inside the Terminal Box with provision of taking out OFC as required. This includes supply of all Installation accessories including the pigtails with connector as per order of practice for installation and commissioning of Optical Fiber System. as per AnnexureInspection: (i) RDSO/RITES if value of item in work morethan 5 lakhs (ii) Consignee if value of whole item in work less than 5 lakhs" | — | 32.00 | — | — | |
| — | — | — | Above/ 124165.12 Below/P | ||
| Supply and Installation of Horn type Loud speaker."(a) Supply of 30 watts Horn speaker with 30 watt tapping, matching transformer and driver unit,as per AnnexureInspection: (i) RDSO/RITES if value of item in work morethan 5 lakhs (ii) Consignee if value of whole item in work less than 5 lakhs"(b ) Installation of Horn type Loud speaker. | — | 32.00 | — | — | |
| — | — | — | Above/ 24448.00 Below/P | ||
| "Supply and Installation of column Speaker 15 W with LMT all metal weather resistant, including fixtures and other material required as per AnnexureInspection: (i) RDSO/RITES if value of item in work morethan 5 lakhs (ii) Consignee if value of whole item in work less than 5 lakhs" | — | 16.00 | — | — | |
| — | — | — | Above/ 262089.28 Below/P | ||
| Supply, Installation of 350 Watt Amplifier with microphone unit "(a) Supply of Microphone with stand, as per AnnexureInspection: (i) RDSO/RITES if value of item in work morethan 5 lakhs (ii) Consignee if value of whole item in work less than 5 lakhs""(b) Supply, Installation Commissioning of 350 Watt Amplifier,as per AnnexureInspection: (i) RDSO/RITES if value of item in work morethan 5 lakhs (ii) Consignee if value of whole item in work less than 5 lakhs" | — | 8.00 | — | — | |
| — | — | — | Above/ 53844.60 Below/P | ||
| "Supply and installation of independent Iron Structure post including water proof protection arrangement with canopy for Horn unit at platform are including painting and erection. as per AnnexureInspection: (i) RDSO/RITES if value of item in work morethan 5 lakhs (ii) Consignee if value of whole item in work less than 5 lakhs" | — | 20.00 | — | — | |
| — | — | — | Above/ 138663.68 Below/P | ||
| "Supply and installation of Wall mounted 19"",6U closed Steel Rack in 600X500mm Section with fan and 6 no sockets and accessories.as per AnnexureInspection: (i) RDSO/RITES if value of item in work morethan 5 lakhs (ii) Consignee if value of whole item in work less than 5 lakhs" | — | 32.00 | — | — | |
| — | 16.00 | — | — | ||
| — | 16.00 | — | — | ||
| — | 12.00 | — | — | ||
| — | 16.00 | — | — | ||
| — | 160.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Updatedtenderdocument_15ABC.pdf
ATTACHMENT
AnnexurePFShed.pdf
ATTACHMENT
CheckListAnnexItoVIIIUPDATED_1.pdf
ATTACHMENT
AnnexureIX.pdf
ATTACHMENT
Annexure-X.pdf
ATTACHMENT
Annexure-XI_1.pdf
ATTACHMENT
AnnexureV.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
Annexure-VIA.pdf
ATTACHMENT
Annexure-VIB.pdf
ATTACHMENT
GCC-2022-Updated-25.09.24.pdf
ATTACHMENT
LabourCessAddendumCorrigendumslipno.4_c.pdf Labour Cess
ATTACHMENT
GCCwithCorrectionSlips1to10.pdf
ATTACHMENT
TermsofPayment.pdf
ATTACHMENT
VICINITYOFUNDERGROUNDCABLE-
ATTACHMENT
OnlineBG.pdf
ATTACHMENT
ACS-11_compressed.pdf
ATTACHMENT
LabourCessAddendumCorrigendumslipno.4_c.pdf
ATTACHMENT
JPO-CABLEDIGGINGWORK-VICINITYOFUNDERGROUNDCABLE-SRDSTESRDEN-C-240124.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .