Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 CrAdmitted-Finance | ₹22.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹22.9 CrAdmitted-Finance | ₹22.9 Cr | L2 | Admitted-Finance |
| 3 | L3₹25.2 CrAdmitted-Finance | ₹25.2 Cr | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s Pushpinder Singh Sidhu Contractor L1 | M/S RAM NARAYAN CONTRACTOR L3 | NAV BHARAT BUILDCON PRIVATE LIMITED L2 |
|---|---|---|---|---|---|---|
| 1.00 | Demolishing of reinforced concrete including stacking of useable material and disposal of unuseable material within 50 m lead inclusive of de-watering wherever required. | 1,573.86 | Cum. | 519.4 ₹8.2 L | 450 ₹7.1 L | 447.67 ₹7.0 L |
| 2.00Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m in dry or moist including dressing of excavated area, dewatering wherever required complete in all respect | ||||||
| 2.10 | Hard soil mixed with Kankar / boulders, Morrum | 1,655.74 | Cum. | 87 ₹1.4 L | 80 ₹1.3 L | 74.99 ₹1.2 L |
| 3.00Excavation including loading unloading disposal and dressing of excavated rock within initial lead of 50m and lift upto 1.5m in dry or moist including dressing of excavated area, de-watering wherever required complete in all respect. | ||||||
| 3.10 | Soft / Disintegrated rock | 335.18 | Cum. | 118 ₹39,551.24 | 100 ₹33,518 | 101.7 ₹34,087.81 |
| 3.20 | Hard rock not requiring blasting | 90.8 | Cum. | 176 ₹15,980.80 | 150 ₹13,620 | 151.69 ₹13,773.45 |
| 4.00 | Providing and Laying in position of Cement concrete Nominal mix (1:2:4) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand)and making good thejointsexcluding thecost ofcentering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 20mm | 2,962.86 | Cum. | 4,425 ₹1.3 Cr | 4,600 ₹1.4 Cr | 3,813.91 ₹1.1 Cr |
| 5.00 | Side shuttering including propping etc. complete (to achieve finish F 2 for :
Block joints of foundation stilling basins buckets, aprons etc. ( non -suspended horizontally laid mass concrete) | 2,015.4 | Sqm. | 127 ₹2.6 L | 160 ₹3.2 L | 160 ₹3.2 L |
| 6.00 | Side shuttering including propping etc. complete (to achieve finish F 2 for Retaining wall, counterfort, abutment, wing walls up stream or down- stream slope facings of dams and open faces of construction joints etc. | 1,527.97 | Sqm. | 173 ₹2.6 L | 160 ₹2.4 L | 180 ₹2.8 L |
| 7.00 | Supplying of M.S. reionforcement including labour charges for bending binding and placing in position all reinforcement as per drawing including cost of binding wire and all leads and lifts using. Tor or ribbed bars (IS: 1786: 1985) | 89,390.24 | Kg. | 72 ₹64.4 L | 65 ₹58.1 L | 62.06 ₹55.5 L |
Tender Value
₹26.2 Cr
EMD Value
₹52.4 L
Closing Date
5 Nov 2020, 4:00 pmClosed
Additional Chief Engineer Water Resources Zone Uda
Additional Chief Engineer Water Resources Zone Udaipur
Rehabilitation and improvement works of Mahi Bajaj Sagar Dam District Banswara under Dam Rehabilitation and Improvement Project DRIP Phase II
2020_WRDAS_184797_1
02/2020-21 ACE Zone Udaipur
Open Tender
Civil Works
1095 days
Banswara
Please refer Tender documents.
4 documents required · 4 mandatory
₹7,500
VIA CHALLAN AS PER MENTIONED IN NIT
₹52.4 L
Udaipur
29 Apr 2021
1 Jun 2020
5 Nov 2020
1 Jun 2020
5 Nov 2020
1 Jun 2020
12 Jun 2020
Amount
Demolishing of reinforced concrete including stacking of useable material and disposal of unuseable material within 50 m lead inclusive of de-watering wherever required.
Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m in dry or moist including dressing of excavated area, dewatering wherever required complete in all respect
Hard soil mixed with Kankar / boulders, Morrum
Excavation including loading unloading disposal and dressing of excavated rock within initial lead of 50m and lift upto 1.5m in dry or moist including dressing of excavated area, de-watering wherever required complete in all respect.
Soft / Disintegrated rock
Hard rock not requiring blasting
Providing and Laying in position of Cement concrete Nominal mix (1:2:4) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand)and making good thejointsexcluding thecost ofcentering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 20mm
Side shuttering including propping etc. complete (to achieve finish F 2 for : Block joints of foundation stilling basins buckets, aprons etc. ( non -suspended horizontally laid mass concrete)
Side shuttering including propping etc. complete (to achieve finish F 2 for Retaining wall, counterfort, abutment, wing walls up stream or down- stream slope facings of dams and open faces of construction joints etc.
Supplying of M.S. reionforcement including labour charges for bending binding and placing in position all reinforcement as per drawing including cost of binding wire and all leads and lifts using. Tor or ribbed bars (IS: 1786: 1985)
Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required for works are performed through drainagr gallery
Up to 5 m. depth
Up to 5 m. to 10 m depth
Up to 10 to 15 m. depth
Up to 15 to 20 m. depth
Up to 20 to 25 m. depth
Beyond 25 m. depth
Washing and open flushing of drilled holes by alternate jet of air and water under pressure prior to pressure washing and flushing or grount after stage grouting including cost of equipment compressed air and etc. complete
Providing and Laying in position of Cement concrete Nominal mix (1:1.5:3) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 20mm
For each subsequent height of 3.0 meter or part thereof above initial lift of 5.0 m from ground level. (upward and downward)
Extrafor for RCCwork for Bed Plate,Girder, Slab etc insuspended for
Extra labour charges for obstruction in laying and placing the reinforced cement concrete due to reinforcement for Columns, slabs, cantilevers projections staircases, lintels, beams, chajjas, Retaining walls, piers, abutments, galleries, arch covers, bed plates, sluice capstan bases etc.
Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates I coils, confirming to IS 3589-200 I or its latest revision/ amendmendment, for following thickness and inside diameter including all taxes, transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge;(excluding earthwork, internal lining and outer coating) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately Dia of Pipe : 150 mm (I.D.) thickness of pipe 5 mm
Dismantling G.I. pipes including excavation and reffilling trenchen after taking out the pipes breaking lead cauiked joints melting of lead and making into block including stacking of pipe lead at site within 50 mtr of dia. Above 150 mmDia upto 300 mm dia
Providing & fixing cast iron double flanged type sluice valve of the following size complete with bolts, nuts, washers and compressed asbestos gaskets as required;
Cutting & clearance of jungle, bushes, shrubs Ankra/Ipomoea, Julicflora typna etc. on canal and bunds in dry/moist/slushy conditions including disposal as per instructions of the Engineer-in-charge. Cost of wood has been deducted from rates and thus will be property of contractor after cutting For dowels and outer slopes.
Supplying and laying aggregate in layers and profile as specified including all leads & lifts.
River gravel 40 to 80 mm size
River gravel 20 to 40 mm size
River gravel up to 20 mm size
R. R. stone pitching, hammer dressed with packing of voids from small stones including all lead & lifts, in required profile of
45 cm thickness in two layers (± 5 % thickness tolerance)
23 cm thickness (± 5 % thickness tolerance)
P&F early steamer emmission type lightening arrester on GI mast with air terminal configured as spheroid which is comprised of separate electrically isolated 4 panels surrounding an earthed centralfinial, the terminal shall be tested by CPRI for impulse current of 45 KA (8/20 Sec)with 5 positive and 5 negetive impulse, the arrester having following protection radius at level 1 : 60-79 m
S& laying of down conductor of 70 Sqmm single core insulated flexible copper cable with accessories as required.
Scraping old paint with caustic soda solution and prepartion the surface including cost of material with all lead & lifts & scaffolding etc Complete
Painting (one or more coats) with black japan paint of aaproved brandand manufacture to give an even shades including cost of material with all leads & lifts scaffolding etc complete
Painting with aluminum paint of approved brand and manufacture to give an even shade one or more coats on old work with all lifts & leads scaffolding etc complete
Applying priming coat with ready mix Zink chromate yellow primer of approved brand & manufacture on steel gel vanised iron/steel wire lncluing with all leads & lifts & scaffolding etc. complete
Painting with enamel paint of approved brand and manufacture to give an even shade on old work (one or more coats)
Design, Drawing, fabrication, supply, erection, testing and commissioning of Automatic lifting beam with all accessories, like automatic detach /attach system, hooks/rollers, guides, pins complete for handling, lowering and lifting of Stop log/ emergency gates including cost of all materials, machinery, tools and tackles, labour, cutting, aligning, welding, finishing, cleaning, applying one coat of zinc rich epoxy primer and two coats of cold applied coal tar epoxy paint etc., complete as per specifications and approved drawings, including packing & forwarding, transportation charges for structural steel components and other materials. (per tonne weight)
Providing and Laying in position of Cement concrete Nominal mix (1:3:6) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand)and making good thejointsexcluding thecost ofcentering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 20mm
Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for foundation including curing all leads of all construction materials including curing etc. complete. (d) In cement sand and mortar (1:6)
Masonry work in Foundation
Plaster in cement sand mortar 1:3 including racking of joints, smooth finishing & curing etc. complete including all leads of all construction materials of thickness: 20 mm thick
Plaster in cement sand mortar 1:4 including racking of joints, smooth finishing & curing etc. complete including all leads of all construction materials of thickness. 20 mm thick
Providing and laying cement concrete coping in (1:2:4) with maximum size of crusher broken aggregate upto 20 mm including shuttering etc. with all leads of material complete in all respect in thickness of 75 mm
Brick masonry (using well burnt clay bricks of size 230 x 110 x 70 mm, class designation 75 as per specification) up to plinth including all leads of all construction materials including curing etc. complete. In CM 1:4
Filling in plinth with locally available river shingle under floors including watering , ramming , consolidating and dressing complete including cost of shingle, and loading and un-loading wherever required with cost of dewatering wherever required, complete in all respect
Precast terrazo tiles of approved make 20mm thick with marble chips of size upto 6mmlaid in floors and landing jointed with neat cement slurry mixed with pinment to match the shade of the tiles includind rubbing and polishing complete on 30mm thick bed of cement sand mortar 1:4 Dark shade using ordinary cement
Add extra over for using 24mm thick terrazo tiles with marble chips of size upto 10mm instead of 20mm thick terrazo tiles with marble chips of size upto 6mm.
Centering and shuttering for slabs, beams, lintels Columns, trough with or without caps and base including propping and remove
Centering and shuttering for piers, galleries, barrels, intake well, sluice well upto 5.0m height from base/floor level (To achieve F2 finish)
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect.
One or more coats on old work including prepartion
Structural Steel work in single section fixed without connecting plate including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr. Height In Flates , Tees, Angles & Channel
Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance.
Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Window side hung (openable)
In composite units of doors, windows and ventilators
Doors
Ventilators top hung
Demolishing stone rubble masonry including stacking of useable material and disposal of unuseable material within 50 meters lead inclusive of de-watering wherever required. In cement mortar
Preparation of foundation of structure including removal of all loose stones, silt and final washing. By manual labour
150 cm high fencing with angle iron post 50x50 x6 mm placed at every 3 m apart 30 cm in ground embedded in cement concrete1:3:6 (30 x30x45 cm) corner and every tenth post to be strutted with 50x50x6 mm angle iron provided with 6 horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with G.I.staples including earth work in excavation etc. complete inclusive of dewatering wherever required.
Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 901 to 2000 Sq.Cm : 25mm thick
Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles ISI marked [IS : 13753] of size 300mm x 200mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster on walls and pillar).).Category-A : Kajaria, Jhonson, , Somani make.
Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm comfirming to IS : 13753 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry including nicely finished joints using water proof joint filler powder (Untile or Roffe make) and finishing with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster) for using 400x400 size tiles
Providing and fixing standard steel door fabricated out of standard rolled section conforming to IS 1038 (revised) with glazzing bars tennoned & riveted to the frame the bottom of shutter shall be provided with 18 gauge M.S. sheet kicking panel, providing and fixing 4mm thick plain float glass, aluminium handles glazing chips etc. completed including two coat of anti corrosive red oxide primer paint With heavy-duty mortice lock
P & F Universal (anglo-Indian type) white glazed vitreous china W.C. pan 1st quality (IS 2556 Marked ) with P or Strap including cutting and making good the wall and floor
P & F WVC wash basin (1st quality, I.S. : 2556 Mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. Pillar cock (IS : 8934 Mark) & 32 mm C.P. brass waste coupling of approved make, 25 mm G.I. waste pipe complete including cutting & making good the wall.: (A) Size 550 mm x 400 mm
(B) Size 630 mm x 500 mm
Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C flooring & over stone slab covering ,80 mm thick slab ,jointing of slab in CM 1:3. Ralthal, Kharanja, 50 mm thick stone partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos C.I foot rests of approved design ,two No. 450 mm dia each Ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr: Size 400 x140x150 cm.(for 50 users)
P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 1000 litres capacity.
Providing &laying C.C. 1:5:10 (Stone aggregate 40mm nominal size) all around S.W. pipe including 15cm thick bed concrete (Width W = Diameter of pipe in Cm. 30cm) (Excluding cost of Pipe 150mm Dia S.W.Pipe
P&F rigid PVC pipe (IS: 4985 mark) class II (4 kg. /Cm2) approved qulity make including joining the pipe with solvent cement rubber ring and lubricant 160mm dia pipe
SITC of silent DG set (As per CPCB Norms) complete with 1500 RPM diesel engine of suitable BHP and AC brushless SPDP alternator mounted on a common base frame and coupled through a flexible coupling or close coupled.Altenator shall be self regulated with standard alternator protection (over voltage, over speed & under Voltage, under speed warning and shut down).Engine shall have resedential silencer, upto 3 m exhaust piping, electronic/mechanical governors, manual and electric start, batteries, engine instruments panel, AVM and with weatherproof,powder coated accoustic enclosure for DG set for sound attenuation fabricated fron 1.6 mm CRCA sheet steel (Structure) with side wall fabricated from 1.6 mm CRCA sheet and filled with 100 mm thick glass wool(96 Kg/Cum)/Foam, as per IS:8183 the doors of 100 mm thick and fabricated from 1.6 mm CRCA sheet packed with accoustic material, canopy fixed with axial flow fan, All doors/opening are sealed with neoprene/EPDN gasket.The enclosure have built-in fuel tank,residential silencer (isolated from Main DG chamber) with protection and tripping of DG set against temperature of more than 50 degree centigrade.All controls for operation of DG set are from outside the enclosure with DG control pannel having microprocessor based Genset monitoring & control system, MCCB, Ammeter, Voltmeter, PF meter, Frequency meter,KWH meter,ind.lamps etc mounted inside enclosure, visible and accessible from outside. The enclosure shall be suitable for following capacity DG set and alternator,noise level shal be less than 75dBA at a distence of 1m, duly certified by authorised agency etc complete in all respect of capacity :Radiator cooled & Turbo charged /AC 250 KVA at 0.80 pf 415 V 50 HZ 3 φ
S/F DG set exhaust piping insulation on 80 mm to 150 mm dia exhaust pipe Asbestos rope insulation
P & F IP-65 / IP-66 protected LED street light luminaire on existing bracket. Fixture made from powder coated single piece pressure die cast aluminium housing with Heat dissipation fins on housing with High Power LEDs of CREE / NICHIA / OSRM/PHILIPS make. Diffuser / Glass cover for ensuring IP-65 protection for Lamp & control gear compartment, System Lumen output of 1500 - 8500 High Power LED, Integrated Driver shall be high efficiency having efficiency > 85% and in compliance to IEC standards System life of 25,000 Burning Hours with 70% of initial Lumens maintained. Fixture shall be in CE Compliance. LED Street Light fixture 30-40 Watt
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 KV grade and approved make in existing surface or recessed conduit / casing capping including making connection etc. as required. 2 x 6.0 Sq. mm. Group-I
P & F of IP 65 / IP66 protected High Power LED Flood Light system with extruded aluminium housing, toughened glass diffuser with suitable lenses on LED to acheive various beam angles, 240V, 50Hz - High Power LED lamps supplied with pre-wired cable of 1 mtr. Integrated Driver shall be high efficiency having efficiency > 85% and in compliance to IEC standards.System life of 25,000 Burning Hours with 70% of initial Lumens maintained. Light output in Cool white or Warm White Colour as per engineers choice. Fixtures shall be CE and compliance. High Power LED Flood Light 160W Group-II
S & F of Street light bracket made out from following size of ' B ' class GI pipe with heavy duty pole clamp, Saddles suitable fastners etc. as required. 25 mm Dia.
Dismantling tile work in floor and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 mtr lead For thickness of tiles 25mm to 40 mm
Providing & laying chequered terrazo tiles of approved make22mm thick with marble chips of size upto 6mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and polishing complete in all respect as per specification, on 28mm thick bed of CM 1.4 (2) Medium shade using approximately 50% white cement and 50% Ordinary. for using 30mm thick chequered terrazo tiles instead of 22mm thick terrazo tiles
Provinding and fixing 50mm dia G.I. medium 'B' class railingwith two horizontal pipes and 1.5 Mtr. Long vertical pipe 1.5Mtr Centre to centre with all accessories likeelbows tees etc.including welding threading and embeddding in cement concrete 1:2:4 block of size 30x30x40 cm with 2 Nos, angle iron 25 x 25 x5 mm size holdfast complete as per design and drawings.
Chipping Concrete Surface, Cleaning the exposed surface of steel and concrete with wire brush, washing with water complete as per specifications excluding scaffolding etc. (Including desposited salt in foundation gallery should be disposed out) excluding scalfolding.etc
Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an evenshade including all scaffolding Old work (one or more Coat )
Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, ift up to 1.5 Mtr, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in lead of 50 mtr. All kinds of soil.
Providing and Laying cement concrete 1:4:8 in sub-base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per Table 600-1, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trail length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonne vibratory roller, finishing and curing as per MoRTH specification : Clause No. 601, 112.
Providing and Laying un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub-base with 43 grade cement, coarse and fine aggregate conforming to IS:383, maximum size of coarse aggregate not exceeding 25mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures and vacuum processing pump as approved, curing compound, finishing to lines and grades as per drawing as per MoRTH Specification : Clause No. 602, 112. Using Cement concrete M-30 pavement Grade
Providing and laying of interlocking concrete block pavement having thickness 80 mm as per drawings and Technical specification clause 1504.
P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. (a) 35.0 Sq.mm Armoured 1 Core
Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 25 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 6 SWG copper Wire
P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size . 50 mm 3.5 Core
Supplying and making end termination with heavy Copper lugs ( Pin / ring type ) duly crimped with crimping tool, PVC tape etc of following size. 50 sqmm
Earth filling with surplus soil excavated from foundation and taken only from outside of building plinth in 15cm compacted layers, including ramming watering and consolidation, lead upto 30 mtr. (MoRTH specification: Clause 301,304 Hard Soil (pick work)
Providing, laying and spreading of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401. By Mix in Place Method (Grading III)
Finishing walls with Acrylic Smooth exterior paint of required shade Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface).
Structural Steel work rivetted, bolted or welded in built up sections,trusses and framed work,including cutting,hoisting (Height upto 10 m) fixing in position and applying a priming coat of approved steel primer all complete. (In flats, Tees, angles & channels
Supply & installation of precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-incharge) 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-incharge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : Ridges plain (500 - 600mm).
37 mm thick shotcrete is to be applied after removal of defective concrete / masonry, cleaning of surface thoroughly, with compressor having base layer of 12mm, and second layer of 25 mm thickness in cement concrete (1:2:1) after proper fixing of 9 gauge welded mesh of good quality rust free of size 50 mm x 50 mm in two layers with anchors / clamps after cleaning the surface by wet sand blasting in stone masonry / concrete complete in all respect. Cement concrete comprising of cement, sand, coarse aggregate, water and quick setting compound in the proportion 1:2:1, sand and coarse aggregate conforming to IS 383 and table no. 1 of IS;9012 respectively.
Extra for each subsequent height 3.00 m or part there-of above initial lift of 5 m from ground level ( upward or downward)
1st Lift
2nd Lift
3rd Lift
4th Lift
5th Lift
Dressing of uneven embankment in required profile.
Threading / turfing of grass on slopes of bunds etc. in rows 15 cm centre to centre in each direction including Ploughing, levelling, breaking of clods, and removal of stones etc. if required including maintenance for 30 days or more till the grass develops fully with all leads and lifts complete.
Drilling holes of 35 mm diameter for anchor rods. i) Upto 1.50 m. Depth
Labour charges for Fixing of anchor bars in neat cement grout including cost of cement and curing etc. complete
Supplying and laying quarry spalls properly graded but not more than 10cm in size with spreading in required profile including all leads & lifts
Raised and cut pointing on stone masonry including racking of joints and curing etc. complete including all leads of all construction materials in mortar ratio. Cement sand mortar 1:3
Demolishing of R.C.C. Work including stacking of steel bars and disposal of unserviceable material within 50 mtr lead
Brick masonary in foundation and plinth with bricks of class designation 75 cm in Cement mortar 1:3
Half Brick masonary in foundation and plinth using bricks of designation 75 in low cost shree Binder and sand mortar 1:2 (for non load bearing wells )
Plaster on new surfece on Well in cement sand morter 1:3 including raking of joints etc. complete fine finish 12 mm thick sqm
Painting with ready mix paint of approved brand and manufacture in all shades to give an even shade : old Steel Work ( one or more coats
SITC of high mast lighting system (as per CP3-TR7/1996 of ILE, UK) consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm, mast head frame assembly with full cover, aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, suitable ropes (AISI 316, 7 / 19 costruction ), EPR insulated PCP sheathed trailing cable, outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning of high mast. ( See table E - 13 for specs.)
P&F TP&N 415 V sheet steel powder coated HBC cum rewire able switch fuse unit with porcelain kit-kat ( w/o HBC ) & neutral link and conforming to IS:13947 P-I&III and making connections with lugs testing etc. as required.100Rating (Group 1)
P & F of aviation obstruction light luminaire comprising of yellow painted die cast aluminium alloy housing, built in 75 VA step up transformer, heat resistant clear glass cover, neon spiral lamp / 2x100W GLS Lamp / LED Lamps complete in all respect (Group-I)
P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size.25 Sqm armoured 3.5 Core
Applying White cement based putty with approvrd brand cement plaster surface for making even surface.
P&F white vitreous china double syphonic european W.C. (IS: 2556 Mark ) With mounted W.V.C. Flushing cistern of ((IS: 25456 Mark ) Of 10litre Capacity complete with all necessery internal fitting including Cutting and making good the wall and Floor.
Distemparing with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding old work (one or more coats) including scrapping : Same colour.
Supplying & Fixing Door, Window, Chowkhats, and frames, including treatment M.S. flat hold fasts of size 250X40X3 mm Fixed with M.S. Bolt 5mm Dia 50mm long duly embedded in cement concrete Sheesham wood grede-1
Providing and Fixing fully panelled double leaf shutter for door as per approved desing and rawing with approvel ordinary C.P./oxidised steel fitting as par annexure 'A' and width of styels & top rails 100mm and lock rails width of 150mm and bottomrails of 200mm width including teak wood beanding of size 19mmx12mm on both faces complete.
30mm thick wood sqm. ISI 9mm thick teak (both faces panels)
35mm thick wood sqm. ISI 12mm thick teak (both faces panels)
P & F G.I. Pipes (Internal work) with G.I. fittings (IS:1239 Mark) & M.S. clamps including cutting and making good the walls and floors :
15 mm dai Nominal bore "B" Class
20 mm dai Nominal bore "B" Class
25 mm dai Nominal bore "B" Class
50 mm dai Nominal bore "B" Class
Renewing glass panes , with putty and nails wherever necessary 4.00 mm thick plain glass panes
SITC of Silent DG Set (As per CPCB norms) complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled. Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown). Engine shall have residential silencer, up to 3 M exhaust piping , electronic / Mechanical governor, Manual & electric Start ,Batteries, Engine instruments panel, AVM and with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mmCRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with 100mm thick glass wool(96Kg/m3)/Foam. as per IS 8183 the doors of 100 mm thick and fabricated from 1.6mm CRCA sheet packed with accoustic material, canopy fixed with axial flow fan , All doors/ opening are sealed with neoprene/EPDN gaskets. The enclosure has built in fuel tank, residential silencer (isolated from main DG chamber) with protection and tripping of DG set Group-II
30 KVA at 0.8 pf 415V 50Hz 3-ǿ
Dismantling old plaster or skirting, racking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 m lead, inclusive of de-watering wherever required.
Fixing glazed/Ceramic/Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS:15477, using 5 Kg. adhesive per sum of tile area, in average 3 mm thickness. Add extra for Fixing giazed/Cermic/Vitrified tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS:15477, using 5 Kg. adhesive per sqm of tile area, in average 3 mm thickness complete.
P & F IP-65 / IP-66 protected LED street light luminaire on existing bracket. Fixture made from powder coated single piece pressure die cast aluminium housing with Heat dissipation fins on housing with High Power LEDs of CREE / NICHIA / OSRM/PHILIPS make. Diffuser / Glass cover for ensuring IP-65 protection for Lamp & control gear compartment, System Lumen output of 1500 - 8500 High Power LED, Integrated Driver shall be high efficiency having efficiency > 85% and in compliance to IEC standards System life of 25,000 Burning Hours with 70% of initial Lumens maintained. Fixture shall be in CE Compliance. LED Street Light fixture 20-25 Watt for Group-III
P & F IP-65 / IP-66 protected LED street light luminaire on existing bracket. Fixture made from powder coated single piece pressure die cast aluminium housing with Heat dissipation fins on housing with High Power LEDs of CREE / NICHIA / OSRM/PHILIPS make. Diffuser / Glass cover for ensuring IP-65 protection for Lamp & control gear compartment, System Lumen output of 1500 - 8500 High Power LED, Integrated Driver shall be high efficiency having efficiency > 85% and in compliance to IEC standards System life of 25,000 Burning Hours with 70% of initial Lumens maintained. Fixture shall be in CE Compliance. LED Street Light fixture 30-40 Watt Group-I
supply and erection of hot dipped galvanised steel swaged tubular pole conforming to IS: 2713-1980 ( part I to II ) with galvanised base plate in position including excavation of the pit and filling the same with c.c. of M-20 grade (1:1.5:3) from base plate to 50 cm above ground level with the help of steel framme not less than 40 cm dia up to 114.3mm outer dia and 50 cm beyond 114.3mm outer dia around the pole . duly finished with cement plaster , earthing , terminals , cable entry , GI cable sleeve complete as required. tube pole shall be fabricated by using ISI mark tube for structural purpose of following height & designation .( See table E- 09 for specs .) 7.5 mtr (410 SP -5 ) Group-II
P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 10.0 Sq.mm 2 core Unarmoured
P / laying ISI marked p.v.c insulated submersible cable confirming to IS:694 with flexible copper conductor including making connection etc. as required. 4.0 sq.mm 3 core flat / round ( Group -I )
Design, Drawing, fabrication, supply, erection, testing and commissioning of Vertical lift fix wheel type sliding gate/inter changeable Stop log gates consisting of skin plate, stiffeners, horizontal girders, pulley, pulley supports, bracings, lifting lug, bracket, rubber seals, clamps plates etc., with all accessories as per relevant for Canal, sluice Vertical gates and spillway gates including cost of all materials, machinery, labour, cutting, bending, aligning, anchoring, welding, seal fixing, tools and tackles etc., finishing, cleaning, applying two coat of zinc rich epoxy primer to give dry film thickness of 70± 5 microns and finish coat(two coats)of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150 ± 5 microns per coat thus total dry film thickness of all coats, including primer coating, should not be less than 350 microns., complete as per specifications and approved drawings complete, including packing &forwarding, transportation charges for structural steel components and other materials.
Painting of spillway gates , canal gates ( both vertical or radial ) , stop log gates , exposed parts and all un machined ferrous surface ( hoist cylinder heads , hydraulic piping , pipe fitting , bonnet covers ) ,exposed to water as per IS 14177 , for which surface preparation by blast cleaning of class "B" primer coat ( one coat ) of inorganic zinc silicate ( preferbly airless spray ) or alternatively , two coats of zinc rich primer ( containing not less than 85% zinc on dry film ) to give dry film thickness of 70 +-5 micron and finish coat ( two coats ) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150 +- 5 micron per coat . thus, total dry film thickness of all the coats , including primer coating , should not be less than 350 microns , this will be include expenses on mobilisation and demobilisation of equipments . for maintenance painting the surface preparation shall be done by appropriate hand and power tool cleaning , prior to hand power tool cleaning .any heavy layer of rust should be removed by cleaned using solvents like clean mineral spirits , xylol or white gasoline . after hand and poor tool cleaning the surface should be cleaned of loose dust and debris and /or blast cleaned as laid down in para 7.0 of IS code 14177 . after the surface preparation the primer and finishing coats shall be carried out as provided above for painting etc. complete.
up to 1.5m height
Beyond 1.5m height
supply and fixing of oil / Air break starter panel made out of sheet steel coated enclosure comprising of over load protection relay short circuit & single phasing protection , ON / OFF push buttons ammeter , volmeter , including lamps etc. complete in all respect suitable for following rating . 3 Hp to 10 Hp ( star / delta ) ( group-I)
SITC of ISI mark( IS:8472) self priming monoblock pump set of approved make, TEFC, permanent split capacitor type (PSC), fitted with thermal overload protection, mechanical seal, 1440/1500 RPM, single phase(180 to 240 V). Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively.( Group-II) 5 HP, 3-Ø, (6-28)Mtr, (45-7.5)LPM
Painting of structural components of Hoist including supporting structures and surfaces of hydraulic hoist sun exposed to water as per IS 14177, for which surface preparation by blast cleaning of class 'B' primer coat (two coats) of Zinc phosphate primer to give dry film thickness of 40 ± 5microns per coat and finish coat(one coat) of alkyd based micaceous iron oxide paint give dry film thickness of 65 ± 5 microns followed by two coats of synthetic enamel paint, using airless spray, to give dry film thickness of 25 ± 5 microns per coat, at an interval of 24 hours. Thus total dry film thickness of all the coats, including primer coating, should not be less than 175 microns. This will include expenses on mobilisation and demobilisation of equipments. For maintenance painting, the surface preparation shall be done by appropriate hand and power tool cleaning. Prior to hand and power tool cleaning, any heavy layer of rust should be removed by chipping. Visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning, the surface should be cleaned of loose dust and debri sand / or blast cleaned as laid down in para 7.0 of IS Code 14177. After the surface preparation, the primer and finishing coats shall be carried out as provided above for painting etc. complete.
up to 1.5m height
Beyond 1.5m height
Painting of machinery, including gearing, housing, shafting, bearing, pedestals, oil tanks, control cabinets, hoist beams, pipe support, clamps,adders etc., of hoists and supporting structures,as per IS 14177, for which surface preparation by blast cleaning of class 'B', primer coat (one coat) of Zinc phosphate paint to give a minimum dry film thickness of 50 ± 5 microns and finish coat (three coats) of aluminium paint or synthetic enamel paint, using airless spray, to provide a dry film thickness of 25 ± 5 microns per coat. Thus, total dry film thickness of all the coats, including primer coat, should not be less than 125 microns. This will include expenses on mobilisation and demobilisation of equipments. For maintenance painting, the surface preparation shall be done by appropriate hand and power tool cleaning. Prior to hand and power tool cleaning, any heavy layer of rust should be removed by chipping. Visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning, the surface should be cleaned of loose dust and debris and / or blast cleaned as laid down in para 7.0 of IS Code14177. After the surface preparation, the primer and finishing coats shall be carried out as provided above for painting etc. complete.
up to 1.5m height
Providing and fixing pressed steel mitred door frames manufactured from commercial mild steel sheet of 1.25mm (16 gauge) thickness including hinges jamb, lock jamb, head and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface including filling with C.C 1:2:4( M-15 Grade)complete in all respect as directed by Engineer-in-charge: e.Profile 'C"
Providing and fixing in position collapsible steel shutters with vertical M.S. M.S., Channels 20x10x2mm and bracket with flat iron diagonals 20x5mm, size with top and bottom rail of T-iron 40x40x6mm. with 40mm dia steel pulley/ ball bearing complete with bolts, nuts locking arrangement inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer (To be measured and paid as per outer dimension). With 100 mm opening when closed
Providing corrugated G.I. sheet roofing fixed with G.I. J or L hooks bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.1. limpet washers filled with white lead and including a coat of approved steel primer and two coat of approved paint on overlapping of sheet complete (upto a pitch of 60 degree) & excluding the cost of purlins rafters and trusses, for class of sheets. add extra over no.10.25 for providing and fixing CGI sheets Vertically or to a pitch exceeding 60 Degree (583+11.50) & extra 0.8mm thick for providing and fixing CGI sheets Vertically or to a pitch exceeding 60 Degree
Providing and Laying in postion cement concrete including curing compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level using crusher broken aggregate. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required.(Complete Rate) & 8 SWG copper wire
Dismantling brick tiles covering in terracing including stacking of serviceable material and disposal of serviceable materialm within 50 mtr lead.
Providing & Laying broken glazed tiles on roof ( broken glezed tiles not less then 9 Kg/Sqm.) on top of hot bitumen@ 0.30 Kg/Sqm. Of VG-10 (80/100) grade and joints filled with cement mortar 1:2 (1 White Cement : 2 Sand) mixed with water proofing compund all complete as per direction of Enggineer in charge.
SITC of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 10 Mtr (IDU to ODU), copper power cable upto 10 Mtr (IDU to ODU), R-22 Refrigerant, wireless Remote, drain pump,suitable for 400/230V +10% of 50 Hz ,1 /3 phase AC supply capable of performing cooling, dehumidification, Air circulation, filteration & ventilation of following capacity with Scroll / reciprocating / rotary compressor as specified. 2 Ton Group-I
Contactor Block ML-2, 32 Ampere, AC-3, 415 Volts, 50 HZ, ISI-3947, EC60947-4-1 for gallery.
Providing and installing ON/OFF switch of control panel of radial gates.
Providing and installing BCH thermal relay MC 305, ANN-3N series A-22-0, 30 Ampere for gallery
Providing and installing Chavi switch of control panel of radial gates.
Providing and installing limit switch housing rollor level 3SE100E of siemens or equivalent make for radial gate.
Providing and installing magnet coil 415 V - 440V, 50 ampere, 4 wires
Providing and installing magnet coil 415 V - 440V, 50 ampere, 2 wires
Providing and installing HT fuse wire
Providing and installing HRC fuse 63 ampere
Providing and installing timer coil 2 wire
Providing and installing timer coil 4 wire
Providing and installing Magnet Brake coil for radial gates 440 Volts 40 Amp
Providing and installing rotary switch AMP meter type 14 S 39 A for gallery
Providing and installing Amperemeter range 60/5A size 4"
P&F two pin energy efficient compact flourescent lamp in existing holders /fixtures as required : 36 watts 4 pin
Providing and installing BCH thermal relay MC 305, ANN-3N series A-22-0, 30 Ampere for gallery
Providing and fixing leather washer of diameter 6"
Providing and installing timer coil 2 wire
Providing and installing timer coil 4 wire
Providing and installing Diesel Filter for generator
Providing and installing air Filter for generator
Providing and installing rotary switch 440V for generator
Providing and installing rotary switch AMP meter type 14 S 39 A for gallery
Providing and installing Timer set complete for gallery
Providing and installing Shut down Valve for generator
Providing and installing BCH Thermal relay 0-30 Ampere for generator
Providing and installing BCH 32 ampere contactor coil 440 V for generator
Providing and installing temperature switch
Providing and installing limit switch 220 Volts Siemens' or equivalent make
Providing and installing main switch 100 Ampere 440 Volts
P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size.(RALLISON/DELTON/HAVELLS/KEI/TEREXAL/PLAZA/POLYCAB/RAJSAFE) ( Armoured)
10 Sqmm 4 Core
P&F energy efficient direct fit (retrofit) LED tube system (with integeral driver) on existing fixtures. Power consumption of 18 W/36W1500/3000 lumen, system lumen efficiency 80 lm/Watt output, life time of 50000 burning hours with 70 % initial lumen maintained.CCT 3000 K, 4000 K and 6000K
4' LED tube shape fixture 18 W (Group-I)
P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with Copper conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 2.5 Sq. mm 4 Core (Armoured)
P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with Copper conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 2.5 Sq. mm 5 Core (Armoured)
P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with Copper conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 10.00 Sq. mm 4 Core (Armoured)
P&F 240 V Sheet steel powder coated rewire able porcelain switch fuse unit conforming to IS:13947 P-I&III including making connections with lugs, testing etc. as required.32A/415V (Group-I)
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, round tiles,Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch,Modular plate with grid plate, screws, making connections, testing etc. as required. Short point ( Up to 3 mtr. ) Group-I
Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, Hot Dipped Galvanized M.S Modular box of 20 SWG with earth terminal, 6 A modular switch, 6 A modular socket, Modular plate with grid plate, screws, making connections, testing etc. as required. Group-I
On Board
Short point (up to 3 mtr.)
S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall, covering conduit and making good the same as required. 32 mm Group-I
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required.
1 x 1.5 Sq.mm
1 x 2.5 Sq.mm
1 x 4.0 Sq.mm
P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required.Single pole & neutral MCB 6 A to 32 A rating Group-I
P & F ISI marked (IS :3854) 6 amp. flush type switch including cutting hole in tile and making connection testing etc. as required. Group-I
P & F of 3 pin 6 amp. flush type socket including cutting hole in tile and making connection testing etc. as required.
P & F following modular accessories made out of unbreakable and fire retardant poly carbonate with silver contacts including making connections testing etc. as required
6 A one way switch
6 A 3 pin Shuttered socket
5 Step fan regulator 2 module
P & F Star rated double ball bearing capacitor start, aluminium body & blade ceiling fan with down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. 1200 mm Sweep 5 Star rated Group-I
Rewinding of three phase squirrel cage induction motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required.
P & F Pilllar Cocks (IS :8934 Mark) of superior quality and approved make: C.P. Pillar cock fancy type 15 mm dia nominal bore
P & F Stop Cock (IS :8931 Mark), superior quality & of approved make: Brass 400 gm. 15mm nominal bore.
P & F box type fluorescent tube fitting fabricated from CRCA sheet and finished with powder coating / stove enamelled paint complete with accessories (Low Loss Copper Choke, starter, starter seat) / Electronic Choke with terminal block duly prewired with copper conductor including making connection, testing etc. as required( without tube). 1 X 36 Watts with EB
Providing of dia 40 mm wire ripe 6 x 36 construction fiber main core right hand lay ungalvanized with UTS of 180 Kg/Sq.mm breaking strength of 95028 Kgs confirming to IS:2266/1989
Labour Charges for Disumbling of old Rope and Reasumbling of New Wire Rope
Providing and applying cardium compound of approved quality to wire ropes of hoists/ gantry cranes as part of annual maintenance including cost of all materials, machinery, labour etc. complete.
Operation of vertical gates, hoist operation, stoplog gates, Gantry Crane, mono rail etc. at Dams for all seasons round the clock whenever required, as per direction of Engineer-in-Charge, by providing skilled & semi skilled staff well conversant with the work of operation of gates as well as meet out all types maintenance & repair work of gates whenever required in any emergency during operation of the gates including deployment of Chowkidar at gate section of the Dam
Providing of Rubber Seals as per IS11855 for dams, sliuce, canals, barrage, stop log gates etc of required size and type and specifications with testing, including all lead and lifts, packing and forwording charges for all components etc. complete in all respect
Rubber Side Seal Z type of Size 125 × 75 x 19 x 33/20 mm
Rubber Bottom Seal KNOTE type with Size 110 × 33/27 x 25 mm
Providing High tensile MS Nut Bolts of required size and type, as per specifications with testing, including all lead and lifts, packing & forwarding charges for all components etc. complete.
Labour charges for removal of existing wornout/damaged bottom rubber seal of crest Radial Gates, Vertical Gates and Intake Service Well Gates of Dam by cutting bolts with gas cutter, providing holes in new rubber seal in sertion of sleevs and fixing over gates with nut blots,washer ect including cost of gas (LPG and Oxygen) cylinder etc complete.
Labour Charges for changing of side rubber seals other removing old seal by cutting boits with gas welding, providing holes in new rubber seal, insertion of sleeves & fixing over gate with nut bolts, washers etc complete including cost of gas cylinder.
Lead screw 20 x 70 mm with lock pin, cotter pin, lock viser, cotter lock, polishing, turning, threading etc.
Worm gear box 6" 30:1 (worm wheel, worm shaft, shaft handle, cap, worm gear box housing, output shaft, housing oil seal etc.
Gear box housing
Screw pipe cover set
Disassemble old system
New system fitting charges
Gear box joint shaft
Coupling set for jointing different shaft in system
Hand drive system
Side Rubber seal J-type for stop log gate & D/S main gate
Upper Rubber Seal J-type for stop log gate & D/S Main gate
Bottom Rubber seal flat type for stop log gate & Main gate
Anabond for stop log gate & D/S main gate
Bolt size 1/2" x 3 " for stop log gate & D/S main gate.
Rubber seal fixing charges for stop log gate & D/S main gate
Steel wire rope 18 mm (Usha Martine)
Construction Of Tube well from ground level & upto 100mtr depth to accomodate housing and assembly pipe of following size in all type of alluvium strata unconsolidated formation such as pebbles, boulder etc. by percussion/rotary drilling method as per IS;2800 Part I: 1991 and IS:2800 (Part I & II) 1979 (both amended upto date) and technical specifications, with gravel as per IS:4097-1967 and its packing as per IS:2800 (Part I & II) 1979 as amended upto date (the work includes the cost of gravel & its primary packing and packing during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development wrk, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water. Nominal bore 200mm dia.
Providing and Lowering of ISI mark Unplastisized ployvinyl chlorideb (PVC-U) casing pipe as per IS: 12818:2010 or amended upto date and technical specification for tube well or DCB with threading winding with superior quality of plastic mesh & rope in three layers with end cap complete. 200mm nominal dia (internal Dia)
Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on top end of casing pipe with GI nipple 45 cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25mm socket with end plug shall also be welded over top plate. A GI Nipple having outside thread of size 1/2" (for installation pressure gauge shall be provided & welded with 80mmGI nipple near top plate nipple shall be provided with end plug. 200mm Dia
Supply & Fixing MS Clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set
Driver for Heavy Machine like chain type Dozers/Shovels, Excavator (Long Boom) JCB Operator Chain type /Tyre Mounted etc. (License Holder) Boring/Wagonet machine operator For Rainy season (Skilled)
Mason/ Painter/ Carpenter/ Electrician /Black smith / Plumber (Grade-II) for operation of 16 Nos Radial gates of mahi main dam For Rainy season (Semi Skilled)
Helper for Steel fabricator / Driller / Truck / Tractor /Compressor/ Jack Hammer /Dumper for operation of 16 Nos Radial gates and gantry crane of mahi main dam For Rainy season (Unskilled)
Beldar/ Coolie / Chowkidar / Water man / Earth- dresser to assist the operator of gantry crane and general maintance of 16 Nos Radial Gates and Gentry Crane and Wartch and ward (Unskilled)
Oiling and greasing of Crest radial gates, verticle gates and intake sercice well gates of Dam including all Charges of man and material complete which include applying Cardium compound to wire ropes, oiling & greasing etc complete As per direction of Engineer-in-charge.
Munshi/Survey Amin/ Density Observer/ Record Keeper/Time Keeper/ Gate Keeper/ Core Observer/ Laboratory Assistant / Gauge Reader / Telephone Assistantt for up- keeping of Flood Gauging Station (Semi skilled)
Beldar/ Coolie / Chowkidar / Water man / Earth- dresser '0 ' Chain Gate / Rest house (Unskilled)
SITC of RO water system with Filtration stage = Particilate filter-Membrane life enhancer filter - sediment filter - Pre carbon filter -RO Membrane filter - Post carbon filter, Input power Rating - 230 v AC , 50 HZ, Percentage of Rejection TDS - 9oo/o or better having following features [a)Double purification by RO with ESS or latest technology with TDS indicator.[b)Spin welded RO Membrane Housing to prevent tempering.[cJ Push fit components for leak proof performance [dJ Fully automatic operation with auto start and auto off.(e)SS/ABS construction for corrosion free lifespan. (f Equally suitable for water from all bore wells, overhead storage tanks, water tankers and even municipal taps.[g)R0 Membrane Flushing - Auto Flush @ Every Start , Every Stop and every One Hour of working for one minute. complete in all respect with followins capacity Purification capaciW- 25 LPH, Duty Cycle 170-250liters/dav
Supervisor for Civil work / HEM Works of Mahi Dam Radial Gate
White washing with lime to give an even shade including all scaffolding for old work ( Two or more coats ) including scrapping old surface and repairing with putty wherever necessary
Colour washing of all shade to give an even shade including all scaffolding for old work ( Two or more coats ) with whiting with a base coat of white washing including scrapping surface
Repair to stone masonry in cement sand mortar 1:6 with old and New stone
Repair to cement plaster in cement mortar 1:6 ( 1 cement :6 fine sand ) including removel of pld plaster in regular shade and white or colour washing stone
Patch repair to cement concrete floor including digging out old floor in regular shade and removal of rebbish curing etc. complete in all respect
painting with ready mix paint of approved brand and manufacture in all shades to give an even shade :
Old wood work (one or more coats)
Old Steel work (one or more coats)
providing corrugated asbesios cement 6 mm thick sheet roofing and fixing with GI J or L -hooks bolts and nuts 8 mm dia GI plain and bitumen washers complete Excluding the cost of purlines , refters and trusses above 60 degree pitch
Design, Drawing, fabrication, supply, erection, testing and commissioning of adequate capacity Moving Gantry Crane according to relevant IS code consisting of rail mounted gantry frame, top platform with handling long/cross travel arrangements ,rope drums, gear systems, rails, electric motors, electromagnetic brake system, operator and panel cabin, control panel, wire rope , ladder, motorized cable reeling drum, suitable counter weight etc. with all accessories for Operating stop log gates elements including cost of all materials, machinery, tools and tackles, labour, aligning, anchoring, welding, cleaning, greasing, applying two coats of zinc chromate red oxide primer three coats of approved synthetic enamel paint etc., complete as per specifications and approved drawings with all lead and lifts, including packing & forwarding, transportation, charges for all materials.
design,drawing, fabricaton , supply , erection ,testing and commissioning of automatic lifting beam with all accessories , like automatic detch/attach system , hooks /rollers , guides , pins complete for handling , lowering and lifting of stop log/ emergency gates including cost of all materials machinery ,tools and tackles , labour, cutting , aligning , welding , finishing , cleaning , applying one coat of zinc rich epoxy primer and two coats of cold applied coal tar epoxy paint etc. complete as per specification and approved drawing , including packing & forwarding, transportation charges for structural steel components and other material . ( per tonne weight )
NAV BHARAT BUILDCON PRIVATE LIMITED
M/S RAM NARAYAN CONTRACTOR
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.69 MB
BOQ_326492.xls
BOQ • 0.46 MB
phaseprogram01062020.xls
Other Document • 0.07 MB
document.pdf
Tender Documents • 3.77 MB
roadmap.pdf
Other Document • 0.02 MB
Download all tender documents and submit your bid