| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.0 LAccepted-AOC 12 MALIKPUR GURDASPUR ROAD SARNA PATHANKOT PUNJAB 145025 | PATHANKOT | PUNJAB | 145025 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹39.2 L+₹20,214 (0.52%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹47.0 L+₹8.0 L (20.6%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not recomended NO remark in WLR of CEWC Qtr ending mar 2024 | |
| 5 | Rejected-Technical FRIENDS COLONY STREET A DHANGU ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | - | Rejected-Technical Not recomended bidder not uploaded the entire Docs in Fist cover 1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
8 Jul 2024, 6:00 pmClosed
GE (AF) Pathankot
GE (AF) Pathankot
Repair to Joint filling of Runway,PTT, All Taxi and All Dispersal and Crack filling of flexible portion of Runway at AFS Pathankot
2024_MES_659055_1
GE/PAF-06/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Pathankot
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Pathankot
₹80,000
Yes
27 Sept 2024
11 Jun 2024
15 Jul 2024
11 Jun 2024
8 Jul 2024
25 Jun 2024
Amount
Racking out existing filling in dummy/construction joints upto 25mm width and depth as required to provide backup rod and minimum 15mm thick sealant compound and making it perfectly U shaped with vertical sides by means of mechanical cutter and ensure that joints should be cleaned to remove sealing compound from sides of joint , after cleaning and fanning with air compressor to make the joints free from all loose material (i.e. dirt/dust etc ) and provide polyethylene foam rod backup material of suitable size (Backup rod to be fixed with wooden roller) and applying primer of approved make to side and bottom of joints and filling with polyurethane sealant of approved make (minimum 15mm thick over backup rod) , all as manufacturer instruction and old material should be removed from Technical area as directed by Engineer-in-Charge. Note: (1) Masking tape on edge of joint to be provided on top surface to give neat finish to sealant and removing the masking tape after sealant is applied. (2) An exclusive team of 06 labourers for each task such as removing of existing fiiling, cleaning of open opened joint, finishing of edges with grinder/cutter, applying of primer by one forward stroke and second backward stroke of brush, then applying joint sealant after appropriate time gap and as directed by the Manufacturer's instruction. (3) Quantity of joint filling material required shall be produced by contractor from approved manufacturer and store under supervision of Engr-in-Charge. Qty shall be procured in advance in cunsultation with Engr-in-Charge on quarterly basis.
Racking out existing filling in dummy/construction joints above 25mm wide upto 40mm wide (for more than 40mm width of joint, for every 25mm width additional length will be measured) and depth as required to provide backup rod and minimum 15mm thick sealant compound and making it perfectly U shaped with vertical sides by means of mechanical cutter and ensure that joints should be cleaned to remove sealing compound from sides of joint , after cleaning and fanning with air compressor to make the joints free from all loose material (i.e. dirt/dust etc ) and provide polyethylene foam rod backup material of suitable size (Backup rod to be fixed with wooden roller) and applying primer of approved make to side and bottom of joints and filling with polyurethane sealant of approved make(minimum 15mm thick over backup rod) , all as manufacturer instruction and old material should be removed from Technical area as directed by Engineer-in-Charge. Note: (1) Masking tape on edge of joint to be provided on top surface to give neat finish to sealant and removing the masking tape after sealant is applied. (2) An exclusive team of 06 labourers for each task such as removing of existing fiiling, cleaning of open opened joint, finishing of edges with grinder/cutter, applying of primer by one forward stroke and second backward stroke of brush, then applying joint sealant after appropriate time gap and as directed by the Manufacturer's instruction. (3) Quantity of joint filling material required shall be produced by contractor from approved manufacturer and store under supervision of Engr-in-Charge. Qty shall be procured in advance in cunsultation with Engr-in-Charge on quarterly basis.
PVC intimation sign boards of different size and 5mm thick with retro reflective coloured cover tape of approved make and pvc coated conduit square of size 40mmx40mm leg 1000 mm length of supports, including excavation in post holes, embedded in ground upto 0.5m in depth in cement concrete 1:2:4 using 20 mm graded crushed stone aggregate with two or more vertical post as required on site and support of board exc. 5 cm with sheet or strong fibre backbone to prevent disintegration during strom complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Retro reflective coloured tape (colour as approved by GE) of approved make and width 15 cm complete all as specified and directed by Engr-in-charge.
M/S P.S CONSTRUCTION CO (BID ID -3045823)
Surya & Gautam Builders (BID ID -3046140)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .