Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹43.7 L+₹3.7 L (9.33%)Rejected-Finance FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L2 | Rejected-Finance Being other than Lowest Tenderer | |
| 3 | L3₹47.4 L+₹7.5 L (18.6%)Rejected-Finance | L3 | Rejected-Finance Being other than Lowest Tenderer | |
| 4 | L4₹53.7 L+₹13.7 L (34.2%)Rejected-Finance | L4 | Rejected-Finance Being other than Lowest Tenderer | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted in Appropriate Category |
Tender Value
₹48.6 L
EMD Value
₹97,500
Closing Date
15 Sept 2022, 6:00 pmClosed
GE (NW) KUNJALI
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8465 REPAIR MAINTENANCE REPLACEMENT OF AC DC SHORE SUPPLY NETWORK INCLUDING SWITCH GEAR AT ND MBI
2022_MES_547572_1
8465/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹97,500
Yes
25 Jan 2023
25 Aug 2022
17 Sept 2022
27 Aug 2022
15 Sept 2022
1 Sept 2022
25 Aug 2022 - 27 Aug 2022
Amount
Supply, fabrication, installation, testing & commissioning of Feeder piller box for looping of cables , in door type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet, front & back openable doors having vertical copper bus bar of capacity 2500 amps for phases and for neutral including powder coated painting, PCC foundation, making spacing for upto 1250Amps MCCCB 3/4pole ,supporting channels,cable termination,cable gland etc complete at jetty/casin including taking down old panel all as directed. MAKE of MCCB : Schinder/ Legrand/Seimens/L & T/ABB
Supply, fabrication, installation, testing & commissioning of Feeder piller box for looping of cables , in door type, dust and vermin proof, made out of 3.15mm thick CRCA sheet, front & back openable doors having vertical copper bus bar of capacity 800 amps for phases and for neutral including 800Amps 4 pole 36kA AC/DC MCCB powder coated painting, , PCC foundation, supporting channels,cable termination,cable gland etc complete at jetty/casin including taking down old panel all as directed. MAKE of MCCB : Schinder/ Legrand/Seimens/L & T/ABB
S&F in repair of double door type vertical type TPN DB 8 Way ,240V with 200A busbar , with metalic double door type IP 43 IK 09 protection suitable for housing MCCB's all as specified and directed by EIC.Make: Legrand cat No 507782/Seimens/C&S. Note : DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
S&F in repair of double door type SPN DB 08 Way ,240V with 100A copper busbar each phase , with metalic double door type IP-43 IK 09 protection suitable for housing MCB's all as specified and directed by EIC. Make: Legrand cat No 507611 /Seimens/C&S. Note : MCB DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
S & F MCCB FP 125 Amps,16KA, complete all as specified and directed. Make : Legrand/Siemens/ABB/ L &T
S & F MCCB FP 400 Amps,25KA, complete all as specified and directed. Make : Legrand/Siemens/ABB/ L &T
S & F MCCB FP 800 Amps,50 KA, complete all as specified and directed. Make : Legrand/Siemens/ABB/ L &T
S & F MCCB FP 1250 Amps,50 KA, complete all as specified and directed. Make : Legrand/Siemens/ABB/ L &T
S & F MCCB FP 1000 Amps,50 KA, complete all as specified and directed. Make : Legrand/Siemens/ABB/ L &T
S & F MCB SP 6-32 Amps,10KA, 'C' series 240V complete all as specified and directed. Make : Legrand/Seimens/C&S
S & F MCB SPN 63 Amps,10KA 'C' series 240V complete all as specified and directed. Make : Legrand/Seimens/C&S
S & F MCB SPN 40 Amps,10KA 'C' series 240V complete all as specified and directed. Make : Legrand/Seimens/C&S
S&F in repairs of 0.71mm thick powder coated aluminium sheet cover, alloy 31000 H4 in ridges, Hips vally gutter including suitable size of revits/nut bolts complete bending, shaping, drilling, cutting notching and all as specified and directed by EIC.
Supply and fixing in repair wall/surface mounted 10W LED batten fitting engineering plastic battern with white acrylic cover complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round/square block-02 Nos including connecting up with twin core copper conductor cable with suitable size and all as directed by Engr-in-Charge. Make : CG/wipro/C&S cat No LTTB2F10WLEDW BATTEN/Bajaj/Havells/Philips
Supply and fixing in repair wall/surface mounted 20W LED batten fitting engineering plastic battern with white acrylic cover complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round/square block-02 Nos including connecting up with twin core copper conductor cable with suitable size and all as directed by Engr-in-Charge. Make : CG/wipro/C&S cat No LTTB4F20WLEDEW BATTEN/Bajaj/Havells/Philips
Supply and fix heat shrinkable jointing STRAIGHT THROUGH JOINT KITcomplete with for 1100V grade cable for XLPE armoured alluminium conductor cable of size 120 to 185 sqmm 3.5 cre complete all as specified and directed. Make : Rychem/3M
Supply and fix heat shrinkable jointing STRAIGHT THROUGH JOINT KIT complete for 1100V for 1100V grade cable for XLPE armoured alluminium conductor cable of size 240 to 400 sqmm 3.5 cre complete all as specified and directed. Make :Rychem/3M
Supply and fix heat shrinkable jointing STRAIGHT THROUGH JOINT KIT complete for 1100V for 1100V grade cable for XLPE armoured alluminium conductor cable of size 95 to 120 sqmm 3.5 cre complete all as specified and directed. Make :Rychem/3M
S & F in repair of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A all as specified and directed by EIC. Make: Siemens/Legrand/C&S.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 240sq mm 3.5 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza Note : 1. The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Excavation in trenches n exc1.5m wide and n exc 1.5m in depth for laying of cables and getting out in loose/soft soil compete all as directed.
Returing filling in including spreading, levelling watering and well ramming in layers not exc 25cm compete all as directed.
Removing excavated material n exc 50cm and deposting where directed at a level n exc 1.5m above the starting point compete all as directed.
M&L for GI pipe light grade 100mm dia for protection of UG cable crossing of nalha/bgrdge/road etc complete all as directed.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 185sq mm 3.5 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza Note : The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 95 sq mm 3.5 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza Note : The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 25 sq mm 3.5 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza Note : The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 70 sq mm 3.5 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza Note : The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable P.V.C. insulated unsheathed bright annealed bare copper conductor single core industrial cables & PVC insulated, PVC round sheathed multicore industrial Cables 240SQMM for voltage grade upto 1100 V. as per IS 694:1990. including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza Note : The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and lay in repair cable P.V.C. insulated unsheathed bright annealed bare copper conductor Four core industrial cables & PVC insulated, PVC round sheathed multicore industrial Cables 70SQMM for voltage grade upto 1100 V. as per IS 694:1990. including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza Note : The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
S&F in repair of double door type vertical type TPN DB 12 Way ,240V with 100A copper busbar , double door type IK 09 protection suitable for housing MCCB's all as specified and directed by EIC.Make: Legrand cat No 507781/Seimens/C&S. Note : DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
Supply , fixing, testing in repairs of JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 25 mm dia with 250 micron ( averaSchneider ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF Powerfill Loresco compound shall be supplied in 50 Pound Bag. ( 1 Bag of 50 Pounds required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set alongwith earth pit weatherproof incl all as specified . Note - Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
S&F galvanised iron strip 25 x 4 mm or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as specified and directed by Engr-in-Charge.
S & F in repair 4 feet, 20W LED tube rod having high quality cross linking glass material T8 retrofit type all as specified directed. Make -C&S cat part No-LT4F20WLEDT8/WDI (TARA-i SERIES) or equivalent Cat part in Bajaj / Philips
R J ENTERPRISES
TETRI ENTERPRISES
DHARMESH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .