Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | ₹34.4 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹37.1 L+₹2.6 L (7.64%)Rejected-Finance | ₹37.1 L+₹2.6 L (7.64%) | L2 | Rejected-Finance Other than Lowest |
| 3 | L3₹37.8 L+₹3.3 L (9.68%)Rejected-Finance C O SHRI AMRENDER KUMAR YADAV IACHHIPUR SANTOSH NAGAR GORAKHNATH GORAKHPUR UTTAR PRADESH PIN 273015 | GORAKHPUR | UTTAR PRADESH | 273015 | ₹37.8 L+₹3.3 L (9.68%) | L3 | Rejected-Finance Other than Lowest |
| 4 | L4₹39.3 L+₹4.9 L (14.2%)Rejected-Finance 11 1 7 P D KYDGANJ PRAYAGRAJ U P PIN 211003 | PRAYAGRAJ | UTTAR PRADESH | 211003 | ₹39.3 L+₹4.9 L (14.2%) | L4 | Rejected-Finance Other than Lowest |
| 5 | L5₹39.4 L+₹4.9 L (14.3%)Rejected-Finance | ₹39.4 L+₹4.9 L (14.3%) | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹47.8 L
EMD Value
₹95,660
Closing Date
14 Dec 2023, 6:00 pmClosed
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR
SPECIAL REPAIR TO ROOF TREATMENT, BER COOLING APPLIANCES AND PROVN OF GAZEBO SY AT 4AFSB VARANASI UNDER GE AF STN GORAKHPUR
2023_MES_615118_3
9086/E8
Open Tender
Civil Works
Item Rate
180 days
GE(AF) GORAKHPUR
Class d cat a i
8 documents required · 8 mandatory
₹500
Yes
GE(AF) GORAKHPUR
₹95,660
Yes
29 Jan 2024
20 Nov 2023
16 Dec 2023
20 Nov 2023
14 Dec 2023
30 Nov 2023
20 Nov 2023 - 23 Nov 2023
Amount
Roughning cleaning to existing RCC roof surface/Roof treatment and removing rubbish off the premises, cleaning surfaces and preparing to receive new roof treatment, complete all as specifed and directed at site.
M&L Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces with liquid WPC @ 150 ml per 50 kg of cement or as per manufacturer instructions ( WPC will be measured and paid separately), finished even and smooth without using extra cement for laying APP mebrane, complete all as specifed and directed at site.
Supply only integral liquid water proofing compound, Make:- Dr Fixit Pidiproof LW+ or equivalent.Complete all as specified and directed.
M&L Rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement including taking down cement or cement lime plaster any description on brick or stone walls, etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed.
Applying evenly a tack coat of industrial bitumen 85/25 @ 1.20 Kg/Sqm incluiding cleaning the surfaces. Complete all as specified and directed.
Cutting out cracks to V-section in existing roofs or ferracing, cleaning out, wetting, grouting with cement and sand slurry 1:3.Complete all as speciied and directed.
Cutting out cracks to V-section in existing roofs or ferracing, cleaning out, and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight).Complete all as speciied and directed.
S&F APP based Polymeric membrane minimum weighing 3Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (weight not less than 150 Grams/Sqm) and on primed surface by forced application. Complete all as specified and directed.
M&L applying of Bituminous aluminium paint over over water proofing membrane @0.15 Litre/Sqm as per manufacturer instructions.Complete all as speciied and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil, complete all as specifed and directed at site.
M&L for Cement concrete Type B1, 1:2:4, 40 mm graded in foundations, filling and mass concrete. Complete all as specified and directed.
S&F steel work in tubular Post/ trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I.S. 1161-1998 grade St-240 including all necessary work as directed by Engr in Charge. Complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated, steel sheet 0.50mm thick of Green colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specifed and directed at site.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any Green having tensile strength of 550 Mpa as in roof covering/cladding/drain to wall, fixed with self tapping screws, complete all as specifed and directed at site.
M&L for preparation of surfaces of any description of new steel over 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer.complete all as specified and directed.
M&L for Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick. Complete all as specified and directed.
M&L for RCC Nominal mix Type A1 1:11/2:3 (20mm graded aggregate) as in Slabs supported on walls, beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like. Complete all as specified and directed.
M&L Formwork to rough flat finish surface of soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping).Compete all as specified and directed.
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoopingfor columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, Compete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 mabove the starting point, complete all as specifed and directed at site.
Supply & Fixing in repairs split type air conditioner of capacity 2.0 TR 3 star rating and EER 3.2. with cordless remote control unit and in built air ioniser ,plasma filter for better indoor air quality, suitable for wall mounted,single phase, 230/250 volt AC including breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing after commissioning as required at site, making necessary connections and M & L for unplasticised PVC pipes medium duty 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer,testing of AC complete all as specified and directed.Make LG/Carrier/Hitachi/OGeneral.( Old retrieved AC shall be deposited to EM store Yard by the contractor)
Supply & Fixing in repairs split type air conditioner of capacity 1.5 TR 5 star rating and EER 3.2. with cordless remote control unit and in built air ioniser ,plasma filter for better indoor air quality, suitable for wall mounted,single phase, 230/250 volt AC including breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing after commissioning as required at site, making necessary connections and M & L for unplasticised PVC pipes medium duty 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer,testing of AC complete all as specified and directed.Make LG/Carrier/Hitachi/OGeneral..( Old retrieved AC shall be deposited to EM store Yard)
Supply & fix in repairs , installation, testing and commissioning refrigerator electric driven single phase 230 Volt AC, 50 Hz freestanding, single door, inverter, direct cool 5 star rating of capacity 215 Ltrs. Make LG model LG 215 L or equivallent model in Samsung / Godrej with latest specifications, complete all as specifed and directed at site. Make LG/Carrier/Hitachi/OGeneral..( Old retrieved refrigerator shall be deposited to EM store Yard)
Supply & fix in repairs , installation, testing and commissioning refrigerator electric driven single phase 230 Volt AC, 50 Hz free standing, double door, inverter, convertible 2 star rating of capacity 325/335 Ltrs. Make LG model LG 335 L or equivallent model in Samsung / Godrej with latest specifications, complete all as specifed and directed at site.Make LG/Carrier/Hitachi/OGeneral..( Old retrieved refrigerator shall be deposited to EM store Yard)
Supply & fix , installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity 40/80 Ltrs complete all as specified and directed.Make LG/Carrier/ Usha/Crompton greaves.( Old retrieved cooler shall be deposited to EM store Yard)
Supply & fix in repairs , installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity 60/120 Ltrs complete all as specified and directed.Make LG/Carrier/ Usha /Crompton greaves.( Old retrieved cooler shall be deposited to EM store Yard)
Supply & fix in repairs Supply and fixing ceiling fans complete with blades, down rods, electronic regulator ( modular type) and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. .( Old retrieved fan shall be deposited to EM store Yard)
Supply & fix in repairs ceiling fans complete with blades, down rods, electronic regulator ( modular type) and accessories, 230 V, 1400 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. .( Old retrieved fan shall be deposited to EM store Yard)
Supply and fix in repairs electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed. .( Old retrieved heater shall be deposited to EM store Yard)
Supply and fixing in repairs voltage stabilizer for automatic operation single phase naturally air cooled indooor type and designed for input voltage between 130 volt to 280 volts with output voltage stabilized at 230 V +/- 2.5% with time delay relay and suitable for fixing / mounting on wall of capacity 1 KVA suitable for refrigerator copper wound complete for refrigerator all as specified and directed. Make Bluebird , Model No. BR113C or equivalent in V Guard / AE or any other sample approved by GE. ( Old retrieved stabilizer shall be deposited to EM store Yard)
Supply and fixing in repairs wall mounting voltage stabilizer for automatic operation single phase naturally air cooled indooor type and designed for input voltage between 130 volt to 280 volts with output voltage stabilized at 230 V +/- 2.5% with time delay relay and suitable for fixing / mounting on wall of capacity 4 KVA copper wound complete all as specified and directed. Make Bluebird , Model No. BA413C or equivalent in V Guard / AE or any other sample approved by GE ..( Old retrieved stabilizer shall be deposited to EM store Yard)
Supply and fixing wall mounting voltage stabilizer for automatic operation single phase naturally air cooled indooor type and designed for input voltage between 130 volt to 280 volts with output voltage stabilized at 230 V +/- 2.5% with time delay relay and suitable for fixing / mounting on wall of capacity 5 KVA coppper wound complete all as specified and directed. Make Bluebird , Model No. BA513C or equivalent in V Guard / AE or any other sample approved by GE..( Old retrieved stabilizer shall be deposited to EM store Yard)
Supply & fixing factory made,universal bracket / wall mounting stand ,made with galvanized structural steel,high strenth,weather proof,powdeer coated,modular construction and not less than 5 Kg and suitable upto 2 TR capacity split type AC.
M & L in repairs for power/sub main wiring with two runs of single core 6 sqmm size and one run of single core 2.5 sqmm (green colour as earth continuty conductor ) PVC insulated unsheathed multi stranded copper conductor cables drawn through and including rigid PVC concealed conduit complete all as specified and directed.( Note - two runs of 6 sq mm single core copper conductor and one runs of 2.5 Sq mm copper conductor shall be measured as one unit length.)
Supply & fixing in repairs earth plug enclosure (plug and socket ) with MCB, SP 20 Amps, complete all as specifed and directed at site.
Supply & Fixing in repairs MCB SPN 32 Amps 240 volts, 10 KA, "C" curve, complete all as specifed and directed at site.
PARIWAR INFRATECH
Shiva Builders
M/S Akhilesh Enterprises
GAYDIN CONSTRUCTIONS
R.S Enterprises
PANDEY TRADERS
M/s SKP CONSTRUCTION
M/S SWATI CONSTRUCTION
ANKIT SHIP REPAIRERS AND SUPPLIERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .